Operating Instructions for Elevator Buffers type LP

Similar documents
INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Starting up hydraulic systems

HPD Hydraulic Post Driver

Safety Shock Absorbers SDH38 to SDH63

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

Safety Shock Absorbers SCS33 to SCS64

Instruction manual and installation guide Traction sheave brake TSB TSB

ABSOLUTE EQUIPMENT PTY LTD

ABSOLUTE EQUIPMENT PTY LTD

OTTO HYDRAULICS GmbH & Co KG SYSTEME UND KOMPONENTEN FÜR ÖLHYDRAULISCHE ANTRIEBE UND STEUERUNGEN SIEMENSSTRASSE 12/ FRIEDRICHSHAFEN

original operating manual Operating manual Translation of the Item-No.: ,

Instruction Manual. Maximum Operating Pressure 510 bar

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

Assembly instructions

Operating Instruction

Operation and Maintenance Instructions. Bollard K12

ENGINE TYPE 912 AND 914 (SERIES) SI R3

Hydraulic Breakers HH35. Prior to Operation. From Serial No Revised We thank you for choosing a HYCON breaker.

X.. Series Helical and Bevel-Helical Gear Units

SERVICE INSTRUCTION PURGING OF LUBRICATION SYSTEM FOR ROTAX ENGINE TYPE 912 AND 914 (SERIES) SI SI Repeating symbols:

Instructions for use. Hawker Premier

Angle seat valve with piston actuator VZXA-...-K

CENTAX-SEC Series B Assembly and operating instructions CX BFS1-LE/SE-**-B M EN Rev. 1

Secoroc G10/G10L Pneumatic Pick Hammer

SECTION 6 2 SERVICE PROCEDURES AND SPECIFICATIONS. Engine. Specifications

Active Controlled Cooling System

* * * * 8 Maintenance Plan 10.1,10.2, ,4 7.1/7.2/7.3

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

ERGO KIT TEK01 SERIES

Operating instructions for Netter pneumatic impactors of the series PKL PKL 2100 PKL 5000 PKL 10000

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PISTON ACCUMULATOR. Installation and operation manual Revision

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Translation of the Original operating instructions Lifting device Z 70 /...

HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: , , , ,

Angle seat valve with diaphragm actuator VZXA-...-M

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Operating instructions for worm gear boxes

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Threaded-body cylinders double acting, max. operating pressure 500 bar

SECTION 6 2 SERVICE PROCEDURES AND SPECIFICATIONS. Engine. Specifications

Heavy-Duty Shock Absorbers HLS-110. Deceleration Technology. ONLINE Calculation and 2D / 3D CAD Download. F m

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

FU01 Tank Assembly. Copyright 1998 Inter-Industry Conference On Auto Collision Repair v.4.0

Pneumatic actuator Assembly & maintenance procedures

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

INSTRUCTIONS AND PARTS LIST FOR MODEL 125H & 150H HAND-OPERATED HYDRAULIC PRESS

Angle seat valve with piston actuator VZXA-...-K

Operating Instructions. TM Girder Clamps

Releasable check valve type RH

Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar

Medium and high pressure pumps

A408 GB. Pneumatic oil and diesel pumps 1:1

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

655001G G

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

GRSM17 Pneumatic Center Punch Tool Owner s Manual and Operating Instructions

INTRODUCTION Please read this manual before you use your jack and ensure you understand its operation and the safety procedures to be observed.

INSTRUCTION MANUAL: Industrial Series Piston Air Compressor. Model Number: V Part Number: L001128KNA

Installation and Operation Instructions RINGFEDER Type 2050 AM RINGFEDER Type 2050 AP

Swing Piston Compressors and Vacuum Pumps

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Heavy Duty Engine Cranes

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

EVAP system, servicing

Vent and bleed filter, water-absorbing. Type BFSK 25 to 125. Contents. Features. RE Edition: Replaces: 05.13

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

Hydraulic Hand Pallet Trucks

PNEUMATIC PUMP Series

Hydronic Corporation

IMPORTANT INSTRUCTIONS FOR OPERATION & MAINTENANCE OF

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

WESCO INDUSTRIAL PRODUCTS, INC. Scale Pallet Truck. Part Number: &

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709


Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Hand pump PUMP1000-4L-CONTROL. User manual

Owners Manual Öhlins shock absorbers, Car Rally & Track

INSTRUCTIONS AND PARTS LIST FOR MODEL 25H HAND-OPERATED HYDRAULIC PRESS

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

VLW18TE, VLW18TI HYDRAULIC VERTICAL LIFTING WEDGES. Operator Instruction Manual INNOVATION IN ITS MOST FUNCTIONAL FORM

HE Stewart Vacuum Gasoline System employs a small tank, installed under the hood. This tank is connected by brass tubing to the intake manifold, also

Operating instructions Accu Jet

HH10/HH10RV Hydraulic Breaker

INDECO LUBEMAXX. Operating and Assembly Manual INDECO LUBEMAXX

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Breathing and air bleed filter, water-absorbing. Type BFSK. Contents. Features. RE Edition: Replaces: 51412

Operating instructions Rerailing Equipment. Hydraulic units GB Edition (Translation of the original operating instructions)

Pneumatic Rotary Actuator DSO-P. Hydro-Pneumatic Actuator DSO-H

Transcription:

Operating Instructions for Elevator Buffers type LP 1 Scope of application The Elevator Buffer type LP is an energy dissipation type buffer according to EN 81-1/2, EN 81-20, EN 81-50 5.5 and therefore can be universally used for all applications in the construction of elevators. The EC type examination permits the use in passenger and freight elevators both under the elevator car and under the counter weight. 2 Functional description Fig. 1a: Buffer with Protection Tube Fig. 1b: Buffer with Linear Slide Operating Instructions Elevator Buffers LP Page 1 Edition 3.3.1 EN of 03.04.2017

In the case of a buffer stroke the piston rod 2 is forced into the cylinder tube 1 and the hydraulic fluid 3 in the tube is displaced and forced to the outside through small throttling ports 4 in the tube wall. The fluid accumulates within the jacket tube 5. At the same time the gas volume 6 above the hydraulic medium is further compressed. The sealing system 7 maintains a reliable seal between the hard chromium-plated piston rod and the atmosphere. After the buffer stroke and return to hydraulic balance the compressed gas volume forces the displaced fluid back into the cylinder and extends the piston rod. The level of the hydraulic fluid at the gas interface can be read at any time through the sight glass 9 without opening the unit. An elastic impact plate 16 damps the impact and reduces the noise. The limit switch 13 monitors the extended ready position of the buffer. The limit switch is actuated by pressure on the piston rod by the linear slide 17 or the protection tube 10 respectively. In the case of buffers equipped with a protection tube 10, for maintenance work the screws 12 on the buffer head 11 are removed. Subsequently, the protection tube can be lowered, which simultaneously actuates the switch 13. The oil filler screw 14 and the gas-filling valve 15 will then be accessible. In the normal operating state the protection tube avoids damage and contamination of the piston rod. 3 General Instructions If people are working in the elevator shaft a suitable refuge must be ensured. For this purpose the general safety instructions of the elevator manufacturer have to be observed. Warning! Buffers are safety devices. Mounting, inspection and maintenance work may only be carried out by expert personnel! Observe the applicable safety instructions! 4 Preparations 4.1 Design Data Among the data on the buffer type plate there is included: Piston diameter and stroke Minimum impact mass, Maximum impact mass and Rated speed The first check should be to ensure that the operating conditions do not exceed this design data. 4.2 Ambient Temperature Limit The ambient temperature should be between -10 C and 50 C. The buffer can be supplied in a special design filled with a special hydraulic oil for low ambient temperatures. This buffer can be used between -20 C and +40 C and is labelled with a special designation for this temperature range. An enhanced EC type examination is also provided. Operating Instructions Elevator Buffers LP Page 2 Edition 3.3.1 EN of 03.04.2017

4.3 Place of Installation The place of installation should be in a clean and dry condition. Verify the place of installation of the buffer and the bearing capacity of the mounting surface. Verify the size of the remaining lower refuge. For an entirely pressed-in elevator car buffer a sufficiently dimensioned refuge must be provided below the elevator car in compliance with the respective code. The piston rod should not be contaminated by external impact. During operation of the elevator it has to be ensured that the surface of the piston rod is free of adherences of snow and/ or ice and not frosted. In case of dissenting operation conditions, please contact Henning GmbH & Co KG. 5 Mounting! Safety Instruction: Prior to all mounting and maintenance work, an appropriate measure to prevent automatic switching on or automatic start-up of the drive must be in place! 1. The buffer is supplied ready for installation complete with oil filling. 2. If the buffer is supplied with pressed-in piston rod, the securing devices should be removed. Cut the securing straps at the side when the buffer is standing upright. Warning! The extending piston rod can cause injury! 3. Fastening material should be ordered separately. Suitable means are heavy-duty dowels or rag bolts M 16x160 DIN 529 with nuts and washers 18 DIN 126. 4. Fastening should be made in the upright condition directly on the ground or on a suitable console. The buffer piston rod should be accurately mounted in the vertical position. Therefore, mounting must be made on a horizontal surface or suitable shims should be used. 5. The buffer should be fixed exactly under the centre of gravity of the elevator car or counterweight respectively. If several buffers are used, these must be distributed symmetrically to the centre. Check the alignment of the buffer e. g. using a water level. The piston rod has to point vertical up. 6. Press-in the piston rod several times by hand. This permits transport-caused air bubbles to escape from the hydraulic fluid. Subsequently, the piston rod must be completely extended and the oil level correct. If buffers may be displaced for service work at the elevator e. g. by swinging to a service position or removing please note: 1. The elevator may only be set into operation again if the buffer is replaced to its working position and fastened correctly. We recommend installing a suitable electrical controlling device. 2. Then press-in the piston rod of the buffer at least two times. This allows air bubbles escaping from the hydraulic cylinder. 3. Finally check, that the piston rod is fully extended and the oil level is correct. 4. Fix suitable instructions for acting near the point of installation. Operating Instructions Elevator Buffers LP Page 3 Edition 3.3.1 EN of 03.04.2017

5.1 Electric Connection Dangerous Voltage! During connection work the installation must be de-energised! Carry out the electric connection to the limit switch 13 (Figures 1a or 1b). During wiring the working range of the linear slide 17 and the protection tube 10 during buffer stroke must be observed. 6 Commissioning! Safety Instruction: During buffer testing no persons are allowed to stay in the elevator shaft! 1. Verify the extended position of the piston rod and the oil level. 2. Carry out a first buffer test with reduced speed and without additional load. 3. Verify the electrical signal of limit switch 13. 4. Wait for approx. 1-2 minutes and then relieve the buffer. 5. Verify the extended position of the piston rod and the oil level. Check the buffer and the impact point for possible damage and oil leaks. 6. If no defects are found, carry out a second buffer test. This test should be carried out, if possible, with rated speed and maximum load. 7. Repeat points 4. and 5.. If no defects are found, the buffer is ready for operation. 7 Regular inspections During regular inspections of the elevator installation or for trouble shooting the following inspections are possible for which all the a/m safety instructions must be observed: 7.1 Inspection of the extended piston rod Buffer with protection tube to Fig. 1a: The sight glass 9 is not masked by the protection tube 10. The limit switch 13 is not actuated. Buffer with linear slide to Fig. 1b: The limit switch 13 is not actuated. The visible part of the piston rod is as long as the respective stroke (see indication on the type plate). Operating Instructions Elevator Buffers LP Page 4 Edition 3.3.1 EN of 03.04.2017

7.2 Oil level check The elevator buffers series LP are equipped with a sight glass as an oil indicator. Therefore, the buffer does not need to be opened for the oil level check! This inspection should only be carried out with fully extended piston rod (see a/m point 7.1). a) Buffer with one sight glass The oil level should be visible in the sight glass 9, see Fig. 2a Oil level minimum Oil level maximum Fig. 2a: Oil level indication with one sight glass b) Buffer with two sight glasses - minimum: the oil level is visible in the lower sight glass - maximum: the oil level is below the top edge of the upper sight glass see Fig. 2b Factory oil filling for buffers with one sight glass is up to the centre of the sight glass (at ambient temperatures of 16 C to 22 C). Factory oil filling for buffers with two sight glasses is below the top edge of the upper sight glass. The oil level is depending on temperature. At ambient temperatures around freezing point, the oil level can drop near the minimum. High ambient temperatures let the oil level rise. If during the oil level check the oil level is found to be too high, air bubbles might be in the oil. In this case first press the piston rod of the (upright Oil level minimum Oil level maximum Fig. 2b: Oil level indication with two sight glasses standing) buffer several times as far as possible. If the oil level is not falling although the piston rod is fully extended, oil must be removed. If the oil level is too low, oil must be added (see point 8.3 "Correction of the oil level"). In this case check the buffer for leakage. 7.3 Gas pressure check For resetting the piston rod after a buffer stroke the buffer is filled with nitrogen. The gas pressure at extended piston rod is 5 bar. The gas pressure may be checked without using a measuring instrument. For this purpose press the piston rod by hand for some centimetres. If the piston rod then returns automatically to its initial position, the gas pressure is sufficient. Otherwise proceed as described under point 8.4 "Gas refilling". 7.4 General visual inspection Pay attention to oil spots on the floor or on the buffer. An oil film on the piston rod 2 is normal. Check the piston rod surface for damage and tightly adherent contaminations. Check the state and function of the limit switch 13. If leaks or damage is found, the buffer must be exchanged or repaired. Operating Instructions Elevator Buffers LP Page 5 Edition 3.3.1 EN of 03.04.2017

7.5 Check the piston rod for icing If the buffer is operated at ambient temperatures below the freezing point, the piston rod must be protected from the accumulation of frost, snow or ice. It is necessary to check whether the measures taken to prevent icing are functioning properly. 8 Maintenance Under normal operating conditions the elevator buffer LP does not require maintenance. However, if during the a/m checks defects are detected, these can be removed as described in the following. Every time, safety measures must be taken against unintentional setting in motion of the elevator! 8.1 Removing the protection tube For buffers with a protection tube (Fig. 1a) this should be removed for maintenance work. For this purpose remove the three hexagonal screws 12. Push the protection tube 10 downward into the service position "X". The oil filling screw 14 and the gas filling valve 15 are now accessible. At the same time the limit switch 13 is actuated. After termination of the maintenance work the protection tube is mounted in reverse order.! Warning! The buffer is pressurised. Prior to opening the buffer and for oil refilling the pressure must be released! 8.2 Relieving gas pressure Remove the valve cap from the gas filling valve 15 in order to uncover the valve opening. Place a tire filling device on the filling valve and let the gas escape. As an alternative you can press in the valve cone with a suitable pointed object and let the gas escape.. Operating Instructions Elevator Buffers LP Page 6 Edition 3.3.1 EN of 03.04.2017

8. 3 Correction of the oil level Remove the oil filling screw 14 after having relieved the gas pressure. For refilling use the following oil types only: a) buffer standard model (-10 C up to +50 C): Hydraulic oil DIN 51524-2 HLP respectively ISO 6743/4 HM viscosity ISO VG 46 b) buffer with low temperature design (-20 C up to +40 C, see label): Hydraulic oil DIN 51524-3 HVLP respectively ISO 6743/4 HV viscosity ISO VG 22 Refill the hydraulic oil: - buffers with one sight glass: until the oil level is in the centre of the sight glass - buffers with two sight glasses: until the oil level is below the top edge of the upper sight glass If the oil level is too high (see 7.2), oil must be removed. The limit values of the oil levels (see Fig. 2a/2b) should absolutely be observed. The correct oil level is only indicated if the piston rod is fully extended. In the case of too high an oil level there is a danger that the buffer becomes overloaded during buffer stroke. If the oil level is too low, the damping effect of the buffer may be reduced. Then replace the oil filling screw 14. Make sure a new copper sealing ring A 14x18 DIN 7603 is used. Subsequently refill gas. If an inspection book is kept for the elevator buffer, the oil level corrections should be recorded here. 8.4 Gas refilling Remove the cap from the gas filling valve 15. Place a tire filling device on the filling valve. All commercially available filling systems can be used for car tire valves VG8. Fill the buffer with nitrogen gas, filling pressure 5 bar. The filling pressure must not be exceeded. The piston rod should now be fully extended. The use of pressurized air instead of nitrogen is allowed. Never fill with oxygen or other inflammable gases such as propane and acetylene! Finally check the gas filling valve 15 and the oil filling screw 14 with a leakdetecting spray or soap water for gas tightness. Replace the valve cap. Operating Instructions Elevator Buffers LP Page 7 Edition 3.3.1 EN of 03.04.2017

9 Measures during operation 9.1 What is to be done after a buffer stroke? During normal elevator operation the buffers do not come into operation. Therefore, a buffer stroke is regularly the result of an operation failure. After release of the buffer and the signalling of the piston rod reset (limit switch 13), as a rule, the elevator is again ready for operation. Nevertheless, we recommend a full visual inspection of the buffer and the elevator. 9.2 What is to be done if oil leakage is detected? Search for the location of oil leak. If leaking oil is visible and the leak cannot be stopped, the buffer should be changed immediately. In the case of small leaks the buffer may remain in use. At first check the oil level of the buffer. If the oil level is below the minimum (Fig. 2a/2b), refill oil (see chapter 8). Subsequently, the buffer should be checked at shorter intervals. In the case of any doubt regarding the state of the buffer, it should be changed. For this purpose Henning offers a repair/exchange service for buffers. Leaked oil should be absorbed using oil binder or cleaning rags. 9.3 What is to be done in the case of too low an oil level? Check the buffer for leakages. If no leaks are found, oil should be refilled (see chapter 8). If oil is leaking, proceed as described in chapter 9.2. 9.4 What is to be done in the case of too high an oil level? Too high an oil level can only occur if too large a quantity of oil has been refilled. Follow the instructions under point 7.2 "Oil level check". Make sure that the piston rod is entirely extended. If oil must be removed, follow chapter 8. 9.5 What to do if the piston rod will no longer fully extend? Refill nitrogen as described under point 8.4. Check the entire buffer with leak detecting spray or soap water for possible gas leakage. If the problem still exists, the buffer should be exchanged or repaired by skilled personnel. 9.6 What is to be done if the piston rod is damaged? Damaged or bent piston rods impair the functional safety of the buffer. Such buffers should be exchanged or repaired by skilled personnel. Operating Instructions Elevator Buffers LP Page 8 Edition 3.3.1 EN of 03.04.2017

10 Service For ordering replacement parts, please, contact our Service Department. Henning GmbH & Co KG offers elevator buffers as repair/ exchange. These buffers can be supplied in a short time, have been overhauled in our works and are supplied with full manufacturer's guaranty. The following buffer-specific data is always required: Buffer type Serial number Maximum and minimum impact mass Rated travel speed. 11 Recycling At the end of its working life, the buffer can be recycled as follows: Relieve the gas pressure as described in 8.2 Fully remove the hydraulic oil and supply it to company for used oil recycling Dispose of the buffer as iron scrap Operating Instructions Elevator Buffers LP Page 9 Edition 3.3.1 EN of 03.04.2017

Appendix Technical Data: Size x Stroke s [mm] Rated speed max. v [m/s] Impact mass min. - max. m [kg] Impact energy max. E [knm] Buffer force max. F [kn] Weight with oil filling G [kg] LP 40 x 80 1,0 450-3200 4,96 90 14 LP 40 x 120 1,3 450-3200 7,44 90 16 LP 40 x 175 1,6 450-3200 10,9 90 19 LP 40 x 275 2,0 450-3200 17,1 90 24 LP 40 x 430 2,5 450-3200 26,7 90 32 LP 50 x 425 2,5 500-4500 37,4 130 47 LP 50 x 695 3,2 500-4500 61,1 130 68 LP 50 x 950 3,7 500-4500 83,5 130 86 Dimensions Type LP 40 with protection tube: S L N A B C D E F G P 80 305 225 120 385 265 175 495 320 275 715 440 160 120 20 18 112 115 140 80 All dimensions in mm. All data subject to modifications! Operating Instructions Elevator Buffers LP Page 10 Edition 3.3.1 EN of 03.04.2017

Dimensions Type LP 40 / 50 with linear slide: S L N A B C D E F G P LP 40 x 80 80 305 225 LP 40 x 120 120 385 265 LP 40 x 175 175 495 320 LP 40 x 275 275 715 440 LP 40 x 430 430 1065 635 LP 50 x 425 425 1065 640 LP 50 x 695 695 1665 970 LP 50 x 950 950 2235 1285 160 120 20 18 116 115 130 80 200 160 20 18 135 155 150 100 All dimensions in mm. All data subject to modifications! Hydraulic oils and allowed ambient temperatures during elevator operation: a) buffer standard model: Hydraulic oil DIN 51524-2 HLP respective ISO 6743/4 HM viscosity ISO VG 46 for ambient temperatures from -10 C up to +50 C b) buffer with low temperature design (upon request): Hydraulic oil DIN 51524-3 HVLP respective ISO 6743/4 HV viscosity ISO VG 22 for ambient temperatures from -20 C up to +40 C c) Special designs with biodegradable or flame-retardant hydraulic fluids (on request): Various special fluids are tested for the hydraulic buffer LP and released for use. Please note the special marking of the buffer and the additional inserts for order documentation in the individual case! Operating Instructions Elevator Buffers LP Page 11 Edition 3.3.1 EN of 03.04.2017