Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units. 70 ka at 45 Vac and 65 ka at 480 Vac RG Circuit /Frame Frame RG Performance at 480 Vac H = 65 kaic C = 00 kaic Poles 3 = Three 4 = Four s 60 = 600 00 = 000 50 = 500 RG Circuit /Frame for OPTIM 60 and 90 RGH 65K RGC 00K Poles 3 = Three 4 = Four RG H 3 50 39 ZG E C Trip Unit 33 = 30+ Electronic LS 3 = 30+ Electronic LSI 35 = 30+ Electronic LSG 35B = 30+ Electronic LS(A), GFA, no trip 36 = 30+ Electronic LSIG 36B = 30+ Electronic LSI(A), GFA, no trip 38 = 30+ Electronic ALSI w/ Maintenance Mode 39 = 30+ Electronic ALSIG w/ Maintenance Mode 39B = 30+ Electronic ALSI(A) w/ Maintenance Mode and GFA, no trip RGH 3 6 T33 W s 6 = 600 0 = 000 5 = 500 Trip Function Digitrip 60 T6 = LI T6 = LSI T63 = LS T64 = LIG T65 = LSG T66 = LSIG Digitrip 90 T9 = LI T9 = LSI T93 = LS T94 = LIG T95 = LSG T96 = LSIG Blank = 80% rated C = 00% rated (except 500A) Terminations M = Metric tapped line/load conductors E = Imperial tapped line/load conductors W = No terminals Feature Blank = No feature B0 = High load alarm B = Ground fault ZG = Zone selective interlocking Modification Suffix R = Ground fault remote RES trip E = 00% protection (new design 30) RES trip unit P = 00% prot. neut. 4P RES trip unit V3 = Electronic trip without ambient temperature marked on trip unit W = w/o terms K = Molded case switch. Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com V4-T-7
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com. Product Selection 70 ka at 45 Vac and 65 ka at 480 Vac RGH with Digitrip 30+ High Interrupting CapacityU e 690 Vac, 70 ka I cu at 45 Vac at 40 C 00 ka at Both 45 Vac and 480 Vac RGH with Digitrip 30+ High Interrupting CapacityU e 690 Vac, 70 ka I cu at 45 Vac Circuit Frame Including Digitrip RMS 30 Electronic Trip Unit with Adjustable Plugs L Adjustable Long Delay Pickup (By Adjustable Plug) S Adjustable Short Delay Pickup with Fixed Short Delay Time (I t Response) or Adjustable Short Delay Time (Flat Response) I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous G Adjustable with Adjustable (Flat Response) LS LSI LSG 3 LSIG 3 8 x I n 8 x I n 8 x I n 00 00A For SCR application, use 000 ampere frame. Order terminals separately. Mounting hardware not included. 3 Ground fault equipped trip units available with remote indicating panel. Add R to catalog number, for example, RGH36035RW. 4 Unprotected left pole neutral. Add P to catalog number for 00% protected left pole neutral, add E for 60% protected, for example, RGH46033PW, RGH46033EW. RG MCCBs have English threading on line and load conductors. Use suffix M for metric threading. V4-T-7 Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com 8 x I n 00 00A Neutral CT for LSG and LSIG 600 3 RGH36033E RGH3603E RGH36035E RGH36036E RGFCT60A 000 3 RGH30033E RGH3003E RGH30035E RGH30036E RGFCT00A 500 3 RGH35033E RGH3503E RGH35035E RGH35036E RGFCT50A at 40 C Circuit Frame Including Digitrip RMS 30 Electronic Trip Unit with Adjustable Plugs L Adjustable Long Delay Pickup (By Adjustable Plug) S Adjustable Short Delay Pickup with Fixed Short Delay Time (I t Response) or Adjustable Short Delay Time (Flat Response) I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous G Adjustable with Adjustable (Flat Response) LS LSI LSG 3 LSIG 3 8 x I n 8 x I n 8 x I n 00 00A 600 4 4 RGH46033E RGH4603E 000 4 4 RGH40033E RGH4003E 500 4 4 RGH45033E RGH4503E 8 x I n 00 00A
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com 00 ka at Both 45 Vac and 480 Vac RGC with Digitrip 30+ Very High Interrupting CapacityU e 690 Vac, 00 ka I cu at 45 Vac at 40 C RGC with Digitrip 30+ Very High Interrupting CapacityU e 690 Vac, 00 ka I cu at 45 Vac, continued Molded Case Switches 5 Circuit Frame Including Digitrip RMS 30 Electronic Trip Unit with Adjustable Plugs L Adjustable Long Delay Pickup (By Adjustable Plug) S Adjustable Short Delay Pickup with Fixed Short Delay Time (I t Response) or Adjustable Short Delay Time (Flat Response) I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous G Adjustable with Adjustable (Flat Response) LS LSI LSG 3 LSIG 3 8 x I n 8 x I n 8 x I n 00 00A 8 x I n 00 00A Neutral CT for LSG and LSIG 600 3 RGC36033E RGC3603E RGC36035E RGC36036E RGFCT60A 000 3 RGC30033E RGC3003E RGC30035E RGC30036E RGFCT00A 500 3 RGC35033E RGC3503E RGC35035E RGC35036E RGFCT50A at 40 C Circuit Frame Including Digitrip RMS 30 Electronic Trip Unit with Adjustable Plugs L Adjustable Long Delay Pickup (By Adjustable Plug) S Adjustable Short Delay Pickup with Fixed Short Delay Time (I t Response) or Adjustable Short Delay Time (Flat Response) I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous G Adjustable with Adjustable (Flat Response) LS LSI LSG 3 LSIG 3 8 x I n 8 x I n 8 x I n 00 00A 600 4 4 RGC46033E RGC4603E 000 4 4 RGC40033E RGC4003E 500 4 4 RGC45033E RGC4503E 600 3 RGK360KSE 000 3 RGK300KSE 600 4 RGK460KSE 000 4 RGK400KSE 8 x I n 00 00A For SCR application, use 000 ampere frame. Order terminals separately. Mounting hardware not included. 3 Ground fault equipped trip units available with remote indicating panel. Add R to catalog number, for example, RGH36035RW. 4 Unprotected left pole neutral. Add P to catalog number for 00% protected left pole neutral, add E for 60% protected, for example, RGH46033PW, RGH46033EW. 5 Molded case switch will trip above 7,500 amperes. RG MCCBs have English threading on line and load conductors. Use suffix M for metric threading.. Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com V4-T-73
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com. RG with Digitrip 60 and 90 at 40 C Long Delay Pickup Long Delay Time Instantaneous Circuit Frame Including Digitrip RMS 60 and 90 Electronic Trip Unit with Plugs Order as Individual Component L Adjustable Long Delay Pickup (I r ) with Adjustable Long Delay Time S Adjustable Short Delay Pickup with Adjustable Short Delay Time (I t or Flat Response) I Adjustable Instantaneous Pickup G Adjustable with Adjustable Ground Fault Time Delay (I t or Flat Response) Order terminals separately. Mounting hardware not included. Not to exceed 00 ampere ground fault pickup. RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required. V4-T-74 Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com Digitrip RMS Interchangeable Plug (Order as Individual Component) LI LS LSI LIG LSG LSIG Fixed Plug 4 Seconds 6 x I r 6 x M and M 0.5 I.0 n 4 Seconds 6 x I r 4 Seconds 6 x I r 6 x M and M 4 Seconds 6 x I r 6 x M and M 4 Seconds 6 x I r 4 Seconds 6 x I r 6 x M and M RGH with Digitrip 60 High Interrupting CapacityU e Max. 690 Vac, 70 ka I cu at 45 Vac 600 3 RGH36T6WP44 RGH36T63WP44 RGH36T6WP44 RGH36T64WP44 RGH36T65WP44 RGH36T66WP44 800 RP6R6A080 000 RP6R6A00 00 RP6R6A0 50 RP6R6A5 Includes 600A rating plug 600 RP6R6A60 000 3 RGH30T6WP49 RGH30T63WP49 RGH30T6WP49 RGH30T64WP49 RGH30T65WP49 RGH30T66WP49 000 RP6R0A00 00 RP6R0A0 50 RP6R0A5 600 RP6R0A60 Includes 000A rating plug 000 RP6R0A00 500 3 RGH35T6WP53 RGH35T63WP53 RGH35T6WP53 RGH35T64WP53 RGH35T65WP53 RGH35T66WP53 600 RP6R5A60 000 RP6R5A00 500 RP6R5A50 RGC with Digitrip 60 Very High Interrupting CapacityU e Max. 690 Vac, 00 ka I cu at 45 Vac 600 3 RGC36T6WP44 RGC36T63WP44 RGC36T6WP44 RGC36T64WP44 RGC36T65WP44 RGC36T66WP44 800 RP6R6A080 000 RP6R6A00 00 RP6R6A0 50 RP6R6A5 Includes 600A rating plug 600 RP6R6A60 000 3 RGC30T6WP49 RGC30T63WP49 RGC30T6WP49 RGC30T64WP49 RGC30T65WP49 RGC30T66WP49 000 RP6R0A00 00 RP6R0A0 50 RP6R0A5 600 RP6R0A60 Includes 000A rating plug 000 RP6R0A00 500 3 RGC35T6WP53 RGC35T63WP53 RGC35T6WP53 RGC35T64WP53 RGC35T65WP53 RGC35T66WP53 600 RP6R5A60 000 RP6R5A00 Includes 500A rating plug 500 RP6R5A50
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com RG with Digitrip 60 and 90, continued at 40 C Long Delay Pickup Long Delay Time Instantaneous Order terminals separately. Mounting hardware not included. Not to exceed 00 ampere ground fault pickup. RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required. Circuit Frame Including Digitrip RMS 60 and 90 Electronic Trip Unit with Plugs Order as Individual Component L Adjustable Long Delay Pickup (I r ) with Adjustable Long Delay Time S Adjustable Short Delay Pickup with Adjustable Short Delay Time (I t or Flat Response) I Adjustable Instantaneous Pickup G Adjustable with Adjustable Ground Fault Time Delay (I t or Flat Response). Digitrip RMS Interchangeable Plug (Order as Individual Component) LI LS LSI LIG LSG LSIG Fixed Plug 4 Seconds 6 x I r 6 x M and M 0.5 I.0 n 4 Seconds 6 x I r 4 Seconds 6 x I r 6 x M and M 4 Seconds 6 x I r 6 x M and M 0.5.0 x In 4 Seconds 6 x I r 0.5.0 x In 4 Seconds 6 x I r 6 x M and M 0.5.0 x In RGH with Digitrip 90 High Interrupting CapacityU e Max. 690 Vac, 70 ka I cu at 45 Vac 600 3 RGH36T9WP44 RGH36T93WP44 RGH36T9WP44 RGH36T94WP44 RGH36T95WP44 RGH36T96WP44 800 RP6R6A080 000 RP6R6A00 00 RP6R6A0 50 RP6R6A5 Includes 600A rating plug 600 RP6R6A60 000 3 RGH30T9WP49 RGH30T93WP49 RGH30T9WP49 RGH30T94WP49 RGH30T95WP49 RGH30T96WP49 000 RP6R0A00 00 RP6R0A0 50 RP6R0A5 600 RP6R0A60 Includes 000A rating plug 000 RP6R0A00 500 3 RGH35T9WP53 RGH35T93WP53 RGH35T9WP53 RGH35T94WP53 RGH35T95WP53 RGH35T96WP53 600 RP6R5A60 000 RP6R5A00 Includes 500A rating plug 500 RP6R5A50 RGC with Digitrip 90 Very High Interrupting CapacityU e Max. 690 Vac, 00 ka I cu at 45 Vac 600 3 RGC36T9WP44 RGC36T93WP44 RGC36T9WP44 RGC36T94WP44 RGC36T95WP44 RGC36T96WP44 800 RP6R6A080 000 RP6R6A00 00 RP6R6A0 50 RP6R6A5 Includes 600A rating plug 600 RP6R6A60 000 3 RGC30T9WP49 RGC30T93WP49 RGC30T9WP49 RGC30T94WP49 RGC30T95WP49 RGC30T96WP49 000 RP6R0A00 00 RP6R0A0 50 RP6R0A5 600 RP6R0A60 Includes 000A rating plug 000 RP6R0A00 500 3 RGC35T9WP53 RGC35T93WP53 RGC35T9WP53 RGC35T94WP53 RGC35T95WP53 RGC5T96WP53 600 RP6R5A60 000 RP6R5A00 Includes 500 A rating plug 500 RP6R5A50 Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com V4-T-75
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com. Accessories Selection Guide and Ordering Information Line and Load Terminals R-Frame circuit breakers use Cu/Al terminals as standard and copper only terminals as an option. Specify if factory installation is required. Must have terminals for 00% rated and or freeze testing requirements. Line and Load Terminals s Terminal Body Material Wire RG Rear Connector Exploded View AWG/kcmil Wire Range/ of Conductors TA000RD Wire Terminal Note: Order one TA000RDM kit per three poles. number includes bus connection, terminals and hardware for either line side or load side of three-pole breaker. Metric Wire Range mm V4-T-76 Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com Hardware Wire Terminals 600 Aluminum Cu/Al Metric 500 000 (4) 300 500 TA600RDM 600 Copper Cu Metric 600 (4) 50 300 T600RDM 000 Aluminum Cu/Al Metric 600 (6) 35 300 TA000RDM Rear Connectors 000 Copper Metric B06RDM 000 Copper Metric B06RDLM 500 Copper Metric B500RDM Conductor (Viewed from Rear of Circuit and Cut Away for Clarity) Rear Connector (Cu) B06RDM B06RDLM (For 00% Application) (For 600A and 000A Frames) B500RDM for 500A Line/Load Conductors Conductor (Viewed from Front of Circuit ) Securing Hardware Securing Hardware Cu Only Terminal T600RDM 3 (For 600A Frame Only) OR Al/Cu Terminal TA600RDM 3 (For 600A Frame Only) Base Mounting Hardware Supplied by customer. Handle Extension Included with breaker. Additional handle extensions are available. Handle Extension Description Single handle extension HEX6 Order one per polesingle terminals individually packed. Order one TA000RD kit per three poles. number includes bus connection, terminals and hardware for either line side or load side of three-pole breaker. 3 For use with 500A Frame. Do not order separately unless for replacement purposes. Included in breaker carton when 500A frame is ordered. RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required.
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Accessories Allowable Accessory Combinations Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles in the circuit breaker. RG-Frame Accessories Legend Applicable in indicated pole position May be mounted on left or right polenot both Accessory available/modification available Note Contact Eaton.. Reference Three-Pole Four-Pole Description Page Left Center Right Left Center Right Neutral Internal Accessories (Only One Internal Accessory Per Pole) Alarm lockout (Make/Break) V4-T-04 Auxiliary switch (A, B) V4-T-04 Auxiliary switch (A, B) V4-T-04 Auxiliary switch and alarm switch combination V4-T-04 Shunt tripstandard V4-T-04 Undervoltage release mechanism V4-T-05 External Accessories Base mounting hardware V4-T-76 Padlockable handle lock hasp V4-T-0 Key interlock kit V4-T-0 Electrical operator V4-T-0 Handle mechanisms V4-T-407 Handle extension V4-T-76 Digitrip 30 test kit V4-T-0 Modifications (Refer to Eaton) Moisture fungus treatment V4-T-00 Freeze-tested circuit breakers Marine/naval application, UL 489 Supplement SA and SB Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com V4-T-77
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com. Technical Data and Specifications UL 489/CSA Interrupting Capacity s Interrupting Capacity (ka Symmetrical s) Circuit Volts AC (50/60 Hz) 40 77 480 600 RGH 3, 4 5 65 50 RGC 3, 4 00 00 65 IEC 947- Interrupting Capacity s Interrupting Capacity (ka Symmetrical s) Circuit Volts AC (50/60 Hz) 40 45 690 RGH 3, 4 I cu 35 70 5 I cs 00 50 3 RGC 3, 4 I cu 00 00 35 I cs 00 50 8 Utilization Category A circuit breakers. See Page V4-T-70 for trip unit specifications. V4-T-78 Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Dimensions and Weights Approximate Dimensions in Inches (mm) RG-Frame Width Height Depth 3 5.50 (393.7) 6.00 (406.4) 9.75 (47.7) 4 0.00 (508.0) 6.00 (406.4) 9.75 (47.7) 4.50 (368.3) 0.6 R (4.) 9.70 (46.4) 5.0 (9.5) 4 Holes 0.44 Dia. (.) Front Cover Cutout C L 7.5 (84.) 6.57 (66.9) 3.3 (333.5) C L Handle 7.75 (96.9) Approximate Shipping Weight in Lbs (kg) RG-Frame Complete 5.00 (38.0) 6.00 (406.4) Three-Pole Four-Pole 600 s RGH, RGC 0 (46.3) 35 (6.) 000 s RGH, RGC 0 (46.3) 35 (6.) 500 s RGH, RGC 35 (6.) 8 (8.6) Front View 3-Pole 5.50 (393.7) 8.5 (09.6) Side View 9.00 (8.6).5 (57.).44 R (.) Tee Connectors May Be Rotated 90 6.75 (7.5). 3.00 (330.) Volume 4Circuit Protection CA0800005EApril 04 www.eaton.com V4-T-79