MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS. MicroStart. IBC control

Similar documents
IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

MANUAL. MiniMax V / VK

PUR (A, B, C, D) INSTRUCTION FOR VARIABLE SPEED WITH WIRING DIAGRAM FOR EMX P10 ROTOR SIZE

DKG-114 MANUAL AND REMOTE START UNIT

Delta HE 35-XX, 55-XX

Technical data. WARNING! Residual voltage is present for 1 minute after disconnecting mains voltage.

RVS-AX Instruction Manual

Application Engineering

Braking Devices BR 230/ Assembly- and Commissioning Instructions

RCEL005 / RCEL

Application Engineering

Motor-drive mechanism, type BUL. Technical guide

CONTROL CENTRE FOR DUAL LINE GREASE LUBRICATION SYSTEM

TDX - Taco Duplex Starter with

Instructions for the BCEA Rotary heat exchanger

Variable speed application guidelines

Emotron DCM Control Unit

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

MODEL 422 Submersible Pump Controller

lubrication systems CME Electric pump for oil and soft grease volumetric

DC Master 24/ A

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dimensions WxHxD [mm] Weight [kg]

Start-up instructions

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

ZB0050 / ZB0051 ZB0070 / ZB0071

RCEL005 / RCEL

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Positive displacement flowmeter for continuous flow measurement

Positive displacement batch controller

FL 150 XT-2 B, F, and C

Industrial Chargers and

Control panel. For 3 three-phase electric pumps with thermal protection and exchanger

J1000. Compact Inverter Series.

EC400 Power Control System

Installation, Operation and Maintenance Manual

Submittal Data Information

SOLSTART Instruction Manual

Commissioning Instructions Inbetriebnahme Anleitung VB 230/ L (LP)

Instructions for the BASIC BCVA Rotary heat exchanger, Sizes

1 Phase electronic contactor (SC 1)

Softstarter Intelligent Controllers

Synchronous motors >>

ECONOMISER SERIES E2T USER MANUAL

Service instructions. MAGNA Series 2000

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

Heat Meter Integrator

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Instruction Manual. Q Series 2 Motor Control Modules - OEM

10V. the rack of the oil pump must be on the

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Designed for ease of integration with automation systems

Panelboards & Motor Starters

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

HERZ Motorised Actuator

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Motor driven valve

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

EC200 ELECTRONIC CONTROL SYSTEM

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

J1000 D E F I 1000 J1000 J1000 J1000 J1000

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah

ECONOVENT Rotary heat exchanger Instruction for variable speed EMX-R PUM with wiring diagram

IGLOO IGLOO EASY INSTRUCTION MANUAL

TPAK Series COOLANT PUMP

Wilo-Control SC-Fire Jockey

Operating Instruction for Flowmonitor. Model: DF-WM

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

Small Full Bridge Permanent Magnet Motor DC Controller User Manual

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

Liko M220 / Liko M230

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

Components for EEx e Panels

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO

Starting of Induction Motors

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

SECTION MOTOR CONTROL

EPS-ECONOMY PUMP STARTER

EC225 Power Control System

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

Mclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546

Installation Instructions

SITESTAR ELECTRONICS CABINET DESCRIPTION

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Power Controller. (see note 1) 10 sec

1. Product Information

Question Number: 1. (a)

Essential equipment for all your requirements

MX431 Generator Automatic Voltage Regulator Operation Manual

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

EC DECLARATION OF CONFORMITY

Mounting and Operating instructions

Product information. MIRA-P Poultry computer

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

SYSDrive Frequency Inverter

Transcription:

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS MicroStart IBC control

PAGE REFERENCE Functional description 1 Technical data 2 Functions 2-3 - Push-button - DIP-switches - Operation indications - Alarm indications Connection diagram 4 Connections 4 Motor connections for single phase motors EMC-installations 5 5 Check before switching on the control unit Putting the equipment into operation 6 6 Manufacturer s declaration 7 Own notes 8

FUNCTIONAL DESCRIPTION MicroStart is a hybrid control unit between the simple on/off-control unit and the more advanced stepless control unit MicroStart, enclosed IP54, is a control unit intended for single phase motors. The motor capacitor can be mounted in the control unit. MicroStart is intended for wheel diameters up to 1,5 m. MicroStart has a built-in soft start-/soft stop function to spare motor and gear. This function is disconnectable. MicroStart has a pause/running time function controlled by the input signal, with a total cycle time of 60 sec. Depending on the level of the input signal, the proportion between pause and running time changes. If the input signal is below the threshold value 0,5V, the wheel stops. MicroStart has a built-in shift of the input signal, which implies that the efficiency of the wheel becomes proportional to the input signal. MicroStart has a build-in cleaning function. When the wheel has been still for 45 minutes, the cleaning function is activated and the wheel rotates for 10 seconds. This function is disconnectable MicroStart has a built-in rotation monitor. A magnetic transmitter is connected to the control unit with a built-in hall element and a magnet with it. This function is disconnectable. 1

TECHNICAL DATA Motor power max 90 W Incoming fuse max 10 A Motor current max 1,0 A Supply input voltage 1x230 V +6-10% 50 Hz Ambient temp. non condensing Protection rating 0-45 O C IP54 Output voltage 1x230 V Weight 0,6 kg Internal fuse*) 1 A Measures, h x w x d 110x164x60 mm *) The fuse protects both motor and electronics FUNCTIONS On the backside of the circuit card the motor capacitor can be mounted Push-button for Reset DIP-switches ON to the left Operation indications Alarm indications PUSH-BUTTON Reset Resets control unit after alarm. Automatic restart after voltage drop. DIP-SWITCHES Clean Rot Soft Test Cleaning function connected at ON. When the wheel has been still for 45 minutes, the cleaning function is activated and the wheel rotates for 10 seconds. Rotation monitor connected at ON. Magnet mounted on wheel and magnet transmitter with it. Soft start / soft stop connected at ON. This function should always be connected to spare motor and gear. In cases of using a contactor and larger motor, this function should be disconnected. Manual run at ON. Used at starting up. The motor runs continuously irrespective of the input signal level. 2

OPERATION INDICATIONS Power Ready Run Rot Current on, lights with a fixed light. Twinkles at tripped control unit. The control unit is in operational level, plinth 5-6 is closed. Indicates that the rotor is rotating. Twinkles when rotation monitor is affected, irrespective of its DIP-switch level. ALARM INDICATIONS Green light diode twinkles and red light diode below is lighted. All alarms are remaining. Rot Tripped rotation monitor. The control unit trips if a pulse is not received every 5 minutes from the rotation monitor. Probable cause of fault at installation - Magnet turned the wrong way. - Magnetic transmitter wrongly connected, wrong polarity. - Distance between magnetic transmitter and magnet too large max. 15 mm. Plausible cause of fault at run Temp - Broken belt - Slipping belt - Stuck wheel - Magnet transmitter or magnet not intact - If thermal contact of motor is not connected to the control unit, the thermal contact may trip. This will make the control unit trip on rotation monitor after 5 minutes. Tripped thermal contact Thermal contact in motor tripped due to too high winding temperature. Thermal contact in motor returns to normal position when motor has cooled down. 3

CONNECTION DIAGRAM Power Signals Capacitor is adjusted to motor size C C L N U V W T T 13 14 15 2 3 5 6 9 10 w br S Input 1x230V 1~ M Output 1x230V Input thermal contact Output alarm relay + Input signal 0-10V Run Input rotation monitor (Max 8A/250V AC) CONNECTIONS Input voltage (L-N) Motor (U-V-W) Capacitor (C-C) Thermal contact (T-T) Alarm relay (13-14-15) Input signal (2-3) Run (5-6) Rotation monitor (9-10) 1x230V +6-10%, 50Hz. Single phase motor 230V. Also see separate connection diagram on page 5. According to the motor supplier recommendations. Must be looped if no thermal contact in motor is connected. Closes between 14-15 at alarm or voltage drop. Max 8A / 250V AC. 0-10 V. Plus connected to terminal 2, minus to terminal 3.. Must be looped if no external start is used. White cable connected to terminal 9, brown to terminal 10. Magnet mounted with south-side (S) pointing at the transmitter. Max. distance 15 mm. 4

MOTOR CONNECTIONS FOR SINGLE PHASE MOTORS Motor capacitor mounted in control unit Motor capacitor mounted adjoining the motor C C C C U V W U V W U V W U V W b br w 1~ M b br w 1~ M b br 1~ M w b 1~ M br w Rotation direction Colour code: b: black br: brown, w:white Colours corresponding to our single phase motors 6 25 40 W. Otherwise, see respective motor supplier s instructions. EMC-INSTALLATION Incoming EKK 3G1,5 Not shielded Motor cable, Ölflex Classic 110 CY, 3/4G0,75 Shielded Magnetic transmitter, LiYCY 2x0,34/0,5 Shielded Input signal, LiYCY 2x0,34/0,5 Shielded EMC-gland shall be used with shielded cable. Cables above, or equivalent, shall be used for fulfilling the EMC-terms. If the thermal contact of the motor is drawn to plinth, this shall be connected to the control unit. The two leaders of the thermal contact may be integrated in the motor cable. 5

CHECK BEFORE SWITCHING ON THE CONTROL UNIT Control that the motor is single phase 230 V. Control that the motor capacitor size is adjusted to the motor. Control that the control unit is connected according to instructions on page 4. Input voltage 230V +6-10%, 50 Hz. Control that the input signal is 0-10 V. PUTTING THE EQUIPMENT INTO OPERATION Should be done in order Control that Control of rotation monitor Control of cleaning function the motor rotates in the correct direction according to the rotation direction of the wheel. At incorrect rotation direction, see motor connections on page 5. Yellow light diode (ROT) should twinkle when magnet passes magnetic transmitter, irrespective of the DIP-switch position. Turn off voltage. Control that the DIP-switch CLEAN is in position ON, and that the input signal is disconnected. After turning on voltage again, the wheel should rotate for 10 sec. 6

MANUFACTURER S DECLARATION The manufacturer s assurance of the agreement of the product with the demands in THE EMC DIRECTIVE EN61000-6-4 (2001). Manufacturer Product Type designation EC directives applied to the product IBC control AB Brännerigatan 5 A, 263 37 HÖGANÄS Control unit for rotating heat exchangers MicroStart EN61000-2: 2001 EN61000-6 - 3: 2001 The manufacturer assures on his own responsibility that the product which this assurance concerns corresponds with the demands in the EC directives stated above. This product is corresponding to the RoHS-directive Höganäs 2006-10-20 IBC control AB Christer Persson MD 7

OWN NOTES 8

OWN NOTES

OWN NOTES

OWN NOTES

F21008901GB VERSION 1.3 2014-01-01 IBC control IBC control AB Brännerigatan 5 A SE-263 37 Höganäs Sweden Tel +46 (0)42-33 00 10 Fax +46 (0)42-33 03 75 www.ibccontrol.se info@ibccontrol.se