United States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018

Similar documents
United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018

Foyers Supreme Inc. Fireplace Products Project # 019-S Model: Fusion Type: Residential Wood Fired Heater February 19, 2016

SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114

SUMMARY. St-jean-sur-Richelieu, 2016, January 12th Client : J.A. Roby Project :PI model : Polaris; Sirius; Véga; Antares; Centauri; Rigel

Tested by: written by :

Tested: written by :

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: CORDWOOD TEST STANDARD: EPA & CSA B MODEL: CADDY WOOD FURNACE

LOPEZ LABS CO-OPERATIVE. heatkit.com/html/lopez.htm 1.) SUMMARY OF 87 MASONRY HEATER EMISSIONS TESTS 2.) SUMMARY OF 14 MASONRY HEATER EMISSIONS TESTS

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

1 st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations. Prepared for:

3 rd Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations. Prepared for:

1st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations

4th Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

Prepared for: Prepared by: 4005 Port Chicago Highway Concord, California

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)

3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Copyright Statement FPC International, Inc

CERTIFIED MODULAR HEAT SHIELD SYSTEM EXTENSION AC02713 INSTALLATION INSTRUCTIONS

4th Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 103 WINDSHIELD DEFROSTING AND DEFOGGING SYSTEMS

Applicable Requirements - NSPS Subpart JJJJ

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Multi-Sector Air Pollutants Regulations (MSAPR) May 2017

PFI Standard Specification for Residential/Commercial Densified Fuel 18-June-2008

ICC-ES Evaluation Report

INTERNATIONAL MARITIME ORGANIZATION (IMO) Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Copyright Statement FPC International, Inc

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

AIR QUALITY PERMIT. Kennesaw State University - Marietta Campus

TITLE DEPARTMENT OF ENVIRONMENTAL MANAGEMENT

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids.

2 a5;- Ar.7(? ffut)"lr- To: Cc: Sent: Friday, December 20,2013 2:09 PM. From: Crccarelli, Kathryn com] ''il

Pursuing high precision, speed, and ease of use

THERMAL SHOCK TEST REPORT

State of California AIR RESOURCES BOARD EXECUTIVE ORDER DE

NADP AMNet Standard Operating Procedure Site Report D: Annual/As Needed Maintenance

Product Evaluation Report

G23 Bulletin # September 1998 Supersedes June 1995

PERFORMANCE DATA [1HZ00788] JULY 09, 2014 For Help Desk Phone Numbers Click here

Table 0.1 Summary Pollutant Discharge Test Results Engine Manufacturer. Number 24652

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 103 WINDSHIELD DEFROSTING AND DEFOGGING SYSTEMS

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 103 WINDSHIELD DEFROSTING AND DEFOGGING SYSTEMS

IDEAL STEEL HYBRID GEAR HEAD STOVES OWNER S MANUAL MODEL 210 BY WOODSTOCK SOAPSTONE COMPANY

ESR ICC Evaluation Service, Inc. Issued September 1, 2007 This report is subject to re-examination in one year.

Georgia Pacific Crossett Operations Hydrogen Sulfide and Meteorological Monitoring Program

Metro and you, building together.

6/1/2011. NSPS and MACT Standards for Combustion Sources at Utility Authorities What happens when a permit has both federal and state regulations?

The bereal Project - Scientific Highlights

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

BULDER 00 ROOMHEATER

Overview of Laboratory Testing for Engine Certifications

Comparing the EPA Non-road Transient Cycle (NRTC) with CanmetMINING LHD test cycles.

DEP7007CC Compliance Certification

Selecting Weights and Certificates

SECTION 602 PORTLAND CEMENT CONCRETE PAVEMENT SMOOTHNESS

Streamlining Multiple Applicable Requirements

ASHRAE GAS-PHASE AIR CLEANER TEST REPORT. Test Laboratory: RTI 3040 Cornwallis Road Research Triangle Park, NC

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test

ABSOLUTE STEEL HYBRID

New Federal Regulations for Internal Combustion Engines. Doug Parce

AIR EMISSION PERMIT NO IS ISSUED TO INTERSTATE POWER COMPANY

KKAI Report No Rev 1 Prepared for BioHeatUSA April 28, 2009

STATE IMPLEMENTATION PLAN CREDIT FOR EMISSION REDUCTIONS GENERATED THROUGH INCENTIVE PROGRAMS (Adopted June 20, 2013)

Appendix K. Final DOC Conditions

EMISSIONS AND FUEL ECONOMY TEST FINAL REPORT (OAE-APSI-4) Locomotive EMD Engine FITCH FUEL CATALYST

Sequence VH Report Forms Version Conducted For

Heritage (Model 8091) Pellet Stove

2017Compliance Table with methods.xlsx

AIR EMISSION PERMIT NO IS ISSUED TO. Northern Natural Gas Company

21 August Mr. Raymond Pilapil Illinois EPA Bureau of Air, Compliance Section P.O. Box Springfield, Illinois

QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL

Report Issued: October 19, 2014 Project No.: 23942

DC710. The Value Leader TM. to be used in conjunction with a Smart Phone/Tablet using the TPI View app.

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT AGRICULTURAL PUMP ENGINE COMPONENT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

MEASUREMENT AND TEST REPORT

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

Regulatory and Permitting Requirements of Stationary Generators In Delaware

Verified Retrofit Technologies and Product Offerings. Northeast Diesel Collaborative February 26, 2015

Performance Rating of Residential Air Filter Equipment

Federal Railroad Administration, DOT CFR section Description Guideline PART 179

Air Individual Permit Permit Limits to Avoid NSR

CAST PIPE FITTINGS COUPLINGS

August CFR Part 63 Subpart ZZZZ review

Subject: Emissions Recall 23U3 Emissions Modification Available for Model Year Volkswagen 2.0L TDI

Yukon Oil Inspection Survey Results and Recommendations

Recordkeeping Requirements of the Federal Motor Carrier Safety Regulations

R E P O R T N U M B E R

RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008)

Client Success Story Sheri Baucom Senior Advisor II

Two-Stroke-Cycle Gasoline Engine Lubricant Evaluation D4857 (Y350M2) ASTM TC Sequence I Test Procedure Title / Validity Declaration Page Form 1

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Example Airshed. Sample January 2019 Monthly Ambient Air Quality Monitoring Report

APPENDIX B ALCOHOL SAMPLE COLLECTION AND TESTING PROCEDURES

Certificate of Accreditation

Transcription:

United States Stove Company Project # 18-415 Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018 ASTM E2779 Standard Test Method for Determining Particulate Matter Emissions from Pellet Heaters 227 Industrial Park Road South Pittsburg, TN 37380 Prepared by: Sebastian Button, Laboratory Supervisor 11785 SE Highway 212 Suite 305 Clackamas, OR 97015-9050 (503) 650-0088 WWW.PFSTECO.COM

This page intentionally left blank. Page 1

Contents Affidavit... 3 Introduction... 4 Notes... 4 Pellet Heater Identification and Testing... 5 Test Procedures and Equipment... 6 Results... 7 Summary Table... 7 Test Run Narrative... 8 Run 1... 8 Test Conditions Summary... 8 Appliance Operation and Test Settings... 8 Settings & Run Notes... 8 Appliance Description... 9 Appliance Dimensions... 9 Test Fuel Properties... 12 Pellet Fuel Analysis... 13 Sampling Locations and Descriptions... 14 Sample Points... 14 Sampling Methods... 15 Analytical Methods Description... 15 Calibration, Quality Control and Assurances... 15 Appliance Sealing and Storage... 15 Sealing Label... 15 Sealed Unit... 16 List of Appendices... 17 Page 2

Affidavit PFS-TECO was contracted by United States Stove Company to provide testing services for the SP1000 Pellet-Fired Room Heater per ASTM E2779, Determining PM Emissions from Pellet Heaters. All testing and associated procedures were conducted at PFS- TECO s Portland Laboratory on 7/11/2018. PFS-TECO s Portland Laboratory is located at 11785 SE Highway 212 Suite 305, Clackamas, Oregon 97015. Testing procedures followed ASTM E2779. Particulate sampling was performed per ASTM E2515, Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel. PFS-TECO is accredited by the U.S. Environmental Protection Agency for the certification and auditing of wood heaters pursuant to subpart AAA of 40 CFR Part 60, New Source Performance Standards for Residential Wood Heaters and subpart QQQQ of 40 CFR Part 60, Standards of Performance for New Hydronic Heaters and Forced Air Furnaces, Methods 28R, 28WHH, 28 WHH-PTS, and all methods listed in Sections 60.534 and 60.5476. PFS-TECO holds EPA Accreditation Certificate Numbers 4 and 4M (mobile). PFS-TECO is accredited by IAS to ISO 17020:2012 Criteria for Bodies Performing Inspections, By A2LA to ISO 17025:2005 Requirements for Testing Laboratories, and by Standards Council of Canada to ISO 17065:2012 Requirements for Bodies Operating Product Certification Systems. The following people were associated with the testing, analysis and report writing associated with this project. Sebastian Button, Laboratory Supervisor Page 3

Introduction United States Stove Company of South Pittsburg, TN, contracted with PFS-TECO to perform EPA certification testing on SP1000 Pellet-Fired Room Heater. All testing was performed at PFS-TECO s Portland Laboratory. Testing was performed by Mr. Sebastian Button. Notes Prior to start of testing, 50 hours of conditioning was performed per ASTM E2779 Prior to start of testing, the dilution tunnel was cleaned with a steel brush. Front filters were changed on sample train A at one hour after the test began. A single, integrated test run, in accordance with ASTM E2779 was performed: o 1 Hour at Maximum Burn Setting o 2 Hours at Medium Burn Setting (Defined as <50% of Maximum Burn Rate) o 3 Hours at Minimum Burn Setting Page 4

Pellet Heater Identification and Testing Appliance Tested: Breckwell SP1000 Serial Number: N/A Prototype Unit; PFS Tracking Number 0004 Manufacturer: United States Stove Company Catalyst: No Heat exchange blower: Integral Type: Pellet Stove Style: Free Standing Date Received: Friday, July 06, 2018 Wood Heater Aging: June 6, 2018 June 7, 2018 Testing Period Start: Wednesday, July 11, 2018 Finish: Wednesday, July 11, 2018 Test Location: PFS-TECO Portland Laboratory, 11785 SE HWY 212 - Suite 305, Clackamas, OR 97015 Elevation: 131 Feet above sea level Test Technician(s): Sebastian Button Observers: N/A Page 5

Test Procedures and Equipment All Sampling and analytical procedures were performed by Sebastian Button. All procedures used are directly from ASTM E2779 and ASTM E2515. See the list below for equipment used. See Appendix C submitted with this report for calibration data. Equipment List: Equipment ID# Equipment Description 041 Rice Lake 3'x3' floor scale w/digital weight indicator 053 APEX XC-60 Digital Emissions Sampling Box A 054 APEX XC-60 Digital Emissions Sampling Box B 055 APEX Ambient sampling box 057 California Analytical ZRE CO2/CO/O2 IR ANALYZER 109A/B Troemner 100mg/200mg Audit Weights 107 Sartorius Analytical Balance 051 10 lb audit weight 095 Anemometer 111 Microtector CC144992 Gas Analyzer Calibration Span Gas CC332147 Gas Analyzer Calibration Mid Gas 090 Dewalt Tape Measure Page 6

Results The integrated test run emission rate for test Run 1 was measured to be 1.49 g/hr with a Higher Heating Values efficiency of 66.4% and a CO emission rate of 0.25 g/min. The calculated first hour particulate emission rate was 1.68 g/hr. The United States Stove Company Model SP1000 Pellet-Fired Room Heater meets the 2020 PM emission standard of 2.0 g/hr per CFR 40 part 60, 60.532 (b). Detailed individual run data can be found in Appendix A submitted with this report. Summary Table Run Number Date Segments Setting BR Run Time (min) Heat Output (BTU/hr) 1st Hr Emissions (g/hr) Integrated Total (g/hr) CO Emissions (g/min) Overall CO Emissions (g/min) Heating Efficiency (%HHV) Overall Heating Efficiency (%HHV) 1 7/11/2018 H 2.35 60 31935 M 0.90 120 10620 L 0.53 180 5813 OA 0.96 360 11805 1.68 1.49 0.19 73.0% 0.30 0.25 63.6% 0.24 59.2% 0.25 66.4% 66.4% Page 7

Test Run Narrative Run 1 Run 1 was performed on 7/11/2018 as an attempted integrated test run per ASTM E2779. The overall test duration was 360 minutes. The particulate emissions rate for the integrated test run was 1.49 g/hr. The run had an overall HHV efficiency of 66.4%. The train A front filter was changed at 1 hr. All test results were appropriate and valid and the burn rate requirement for the integrated test run were achieved. There were no anomalies and all criteria were met. Test Conditions Summary Testing conditions for all runs fell within allowable specifications of ASTM E2779 and ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below. Runs Ambient ( F) Relative Humidity (%) Pre Post Pre Post Average Barometric Pressure (In. Hg.) Preburn Fuel Weight (lbs) Test Fuel Weight (lbs) Test Fuel Moisture (%DB) Test Run Time (Min) 1 77 81 43.8 39.0 29.95 5.4 13.4 6.0 360 Appliance Operation and Test Settings The appliance was operated according to procedures as described in the Operations Manual, found in Appendix B submitted with this report. Detailed run information can be found in Appendix A submitted with this report. Settings & Run Notes Run 1 Heat Setting #5 Pre-Burn Test Run High Segment: Heat Setting #5 Medium Segment: Heat Setting #2 Low Segment: Heat Setting #1 Page 8

Appliance Description Model(s): SP1000 Additional Models Discussion: None Appliance Type: Pellet-Fired Room Heater Air Introduction System: Air enters the burn chamber by being pulled though the firepot, via the exhaust blower, see air flow diagram in Appendix D. Combustion Control: Feed rate is electronically controlled via user-selectable controls. Baffles: N/A Flue Outlet: 3-inch exhaust outlet located on the bottom/rear of the appliance. Appliance Dimensions SP1000 Dimensions Height Width Depth 32.75 25.75 23.75 Firebox Volume N/A Pellet Stove Weight 275 lbs Appliance design drawings can be found in Appendix D submitted with the CBI copy of this report. Page 9

Appliance Front Appliance Left Page 10

Appliance Right Appliance Rear Page 11

Test Fuel Properties Test fuel used was purheat Wood Pellet Fuel, a PFI Certified Premium Pellet Brand. A sample of pellets was sent to Twin Ports Testing for analysis, see report below. Page 12

Pellet Fuel Analysis Page 13

Sampling Locations and Descriptions Sample ports are located 16.5 feet downstream from any disturbances and 1 foot upstream from any disturbances. Flow rate traverse data was collected 12 feet downstream from any disturbances and 5.5 feet upstream from any disturbances. (See below). Sample Points Page 14

Sampling Methods ASTM E2515 was used in collecting particulate samples. The dilution tunnel is 6 inches in diameter. All sampling conditions per ASTM E2515 were followed. No alternate procedures were used. Analytical Methods Description All sample recovery and analysis procedures followed ASTM E2515 procedures. At the end of each test run, filters, O-Rings and probes were removed from their housings, dessicated for a minimum of 24 hours, and then weighed at 6 hour intervals to a constant weight per ASTM E2515-11 Section 10. Calibration, Quality Control and Assurances Calibration procedures and results were conducted per EPA Method 28R, ASTM E2515-11 and ASTM E2780-10. Test method quality control procedures (leak checks, volume meter checks, stratification checks, proportionality results) followed the procedures outlined. Appliance Sealing and Storage Upon completion of testing, the appliance was secured with metal strapping and the seal below was applied, the appliance was then returned to the manufacturer s location at: 227 Industrial Park Road, South Pittsburg, TN 37380 for archival. Sealing Label Page 15

Sealed Unit Page 16

List of Appendices The following appendices have been submitted electronically in conjunction with this report: Appendix A Test Run Data, Technician Notes, and Sample Analysis Appendix B Labels and Manuals Appendix C Equipment Calibration Records Appendix D Design Drawings (CBI Report Only) Appendix E Manufacturer QAP (CBI Report Only) Page 17