TIFICATION OF ADDENDUM ADDENDUM. 1 DATED 7/02/2004 Control 0009-02-049, ETC. Project CM 97(89) Highway SH 78, ETC. County DALLAS Ladies/Gentlemen: Attached please find an addendum on the above captioned project. Included in the attachment is an adendum notification which details the changes the respective proposal pages which were added / or changed. Except for new bid insert pages, it is unnecessary to return any of the pages attached. Bid insert pages must be returned with the bid proposal submitted to the Department, unless your firm is submitting a bid using a computer print out. The computer print out must be changed to reflect the new bid item information. Contractors material suppliers, etc. who have previously been furnished informational proposals are not being furnished a copy of the addendum. If you have a subcontractor on the above project, please advise them of this addendum. Acknowledgment of this addendum is not requested if your company has been issued a proposal stamped This Proposal Issued for Informational Purposes. You are required to acknowledge receipt of this addendum by entering the date, which appears at the top of this letter on the Addendum Acknowledgement Form, contained in your bid proposal. Failure to Acknowledge receipt of this addendum in your bid proposal will result in your bid not being read. 04/99
SUBJECT: PLANS AND PROPOSAL ADDENDUMS PROJECT: CM 97(89) CONTROL: 0009-02-049 COUNTY: DALLAS LETTING: 07/08/2004 REFERENCE : 0628 PROPOSAL ADDENDUMS ------------------ _ PROPOSAL COVER X BID INSERTS (SH..: 13-14 ) _ GENERAL TES (SH..: ) _ SPEC LIST (SH..: ) _ SPECIAL PROVISIONS: ADDED: DELETED: _ SPECIAL SPECIFICATIONS: ADDED: DELETED: X OTHER: PLAN SHEETS RIPTION OF ABOVE CHANGES (INCLUDING PLANS SHEET CHANGES) PLAN SHEETS: SHEETS 3B AND 120A HAVE BEEN REPLACED BID INSERTS: 13-14; 5421-5017 HAS BEEN ADDED 5421-5020 QUANTITY CHANGED FROM 120 EA TO 1 EA 1-1
. 100 5002 PREP ROW 104 5001 REMOV CONC (PAV) 104 5009 REMOV CONC (SDWLK) 104 5011 REMOV CONC (DRVWY) KM.843 1 M2 2,666.000 2 M2 788.000 3 M2 76.000 4 104 5013 REMOV CONC (CURB & GUTTER) M 209.000 5 104 5017 REMOV CONC (DRCTN ISL) 110 5001 EXCAVATION (RDWY) M2 255.000 6 M3 1,236.570 7 160 5006 FURN AND PLAC TPSL (CL 2)(100 MM) M2 252.000 8 162 5009 BLOCK SOD (ST AUGUSTINE) M2 252.000 9 164 5025 002 BRDCST SEED (PERM)(URBAN)(CLAY) 168 5002 VEG WATERING (TEMP EROSN CONTROL) M2 265.000 10 KL 16.270 11 1-14
. 340 5007 004 ASPH CONC (TY B) 360 5011 031 MO CURB (150 MM) M3 412.700 12 M 1,941.000 13 360 5066 031 CONC PAV (CPCD)(200 MM)(MOD) M2 4,057.000 14 400 5001 STRUCT EXCAV 464 5003 001 RC PIPE (CL III) (450 MM) 464 5005 001 RC PIPE (CL III) (600 MM) M3 190.000 15 M 1.740 16 M 1.160 17 465 5291 INLET (COMPL)(RECESSED)(3.048 M) EA 1.000 18 465 5531 INLET (COMPL)(RECESSED) EA 3.000 19 496 5007 REMOV OLD STR (SMALL)(INLET) EA 1.000 20 500 5001 MOBILIZATION LS 1.000 21 502 5001 020 BARRICADES, SIGNS AND TRAF HANDLE MO 6.000 22 2-14
. 530 5083 004 DRVWYS (CONC)(VAR H) M2 58.000 23 531 5003 004 CONCRETE SIDEWALK (WHEELCHAIR RAMP) 531 5024 004 CONCRETE SIDEWALK (100 MM) M2 38.000 24 M2 729.000 25 531 5040 004 WHEELCHAIR RAMP (TY 7) 531 5041 004 WHEELCHAIR RAMP (TY 8) 536 5002 CONC MEDIAN 536 5003 CONC DIRECT ISLAND 618 5002 CONDUIT (RM)(25 MM) 618 5005 CONDUIT (RM)(50 MM) EA 2.000 26 EA 1.000 27 M2 643.000 28 M2 62.000 29 M 12.000 30 M 4.500 31 618 5011 CONDUIT (PVC)(SCHD 40)(50 MM) M 23.000 32 3-14
. 618 5013 CONDUIT (PVC)(SCHD 40)(75 MM) 618 5014 CONDUIT (PVC)(SCHD 40)(100 MM) 618 5032 CONDUIT (PVC)(SCHD 40)(BORE)(50 MM) 618 5035 CONDUIT (PVC)(SCHD 40)(BORE)(100 MM) 618 5045 CONDUIT (PVC)(SCHD 40)(25 MM) 618 5049 CONDUIT (PVC)(SCHD 40) SOIL (50 MM) 618 5053 CONDUIT (PVC)(SCHD 40) SOIL (75 MM) 618 5070 CONDUIT (PVC)(SCHD 40)ROCK(BORE)(50 MM) 620 5004 ELEC CONDUCTOR (. 6) BARE 620 5007 ELEC CONDUCTOR (. 12) INSULATED M 20.000 33 M 32.500 34 M 40.000 35 M 122.000 36 M 57.000 37 M 260.000 38 M 16.000 39 M 30.000 40 M 314.000 41 M 48.000 42 4-14
. 620 5009 ELEC CONDUCTOR (. 8) INSULATED 620 5010 ELEC CONDUCTOR (. 6) INSULATED 624 5001 GROUND BOX TY A (122311) W/APRON 624 5003 GROUND BOX TY C (162911) W/APRON M 300.000 43 M 69.000 44 EA 23.000 45 EA 2.000 46 628 5106 ELEC SERV (SPECIAL) (TY 1) EA 2.000 47 644 5048 SM RD SGN ASSM TY TWT(1)UA(P) 644 5058 SM RD SGN ASSM TY 10BWG(1)SA(T) 649 5002 REMOV SMALL RDSD SGN ASSMS 649 5006 RELOC SMALL RDSD SGN ASSMS 656 5003 FND FOR TRAF SIG (600 MM DRIL SHFT) 656 5004 FND FOR TRAF SIG (750 MM DRIL SHFT) EA 2.000 48 EA 1.000 49 EA 1.000 50 EA 1.000 51 M 3.600 52 M 4.000 53 5-14
. 656 5005 FND FOR TRAF SIG (TYA)(900MM DRIL SHFT) 656 5010 FND FOR RDWY ILL ASM (TYA)(750MM DR SH) M 28.000 54 M 3.660 55 656 5013 TRAF SIG CNTRL FND M3 1.600 56 662 5001 005 WRK ZN PAV MRK REMOV (W) (SLD) (100 MM) 662 5002 005 WRK ZN PAV MRK REMOV (W) (BRK) (100 MM) 662 5011 005 WRK ZN PAV MRK REMOV (W) (SLD) (600 MM) 662 5023 005 WRK ZN PAV MRK REMOV (Y) (SLD)(100 MM) 666 5001 012 REFL PAV MRK TY I (W) (SLD) (100 MM) 666 5002 012 REFL PAV MRK TY I (W) (BRK) (100 MM) M 4,620.400 57 M 616.000 58 M 174.000 59 M 2,024.000 60 M 105.000 61 M 929.000 62 6-14
. 666 5003 012 REFL PAV MRK TY I (W) (DOT) (100 MM) 666 5004 012 REFL PAV MRK TY I (W) (SLD) (150 MM) 666 5011 012 REFL PAV MRK TY I (W) (SLD) (450 MM) 666 5035 012 REFL PAV MRK TY II (W) (SLD) (100 MM) 666 5036 012 REFL PAV MRK TY II (W) (BRK) (100 MM) 666 5037 012 REFL PAV MRK TY II (W) (DOT) (100 MM) 666 5038 012 REFL PAV MRK TY II (W) (SLD) (150 MM) 666 5043 012 REFL PAV MRK TY II (W) (SLD) (450 MM) 668 5071 PREFAB PAV MRK TY C (W) (ARROW) 668 5072 PREFAB PAV MRK TY C (W) (DBL ARROW) 668 5075 PREFAB PAV MRK TY C (W) (WORD) M 293.000 63 M 1,056.500 64 M 156.600 65 M 105.000 66 M 929.000 67 M 293.000 68 M 1,056.500 69 M 156.600 70 EA 21.000 71 EA 2.000 72 EA 11.000 73 7-14
. 672 5006 004 RAIS PAV MRKR CL B (REFL) TY I-A 672 5007 004 RAIS PAV MRKR CL B (REFL) TY I-C 672 5010 004 RAIS PAV MRKR CL B (REFL) TY II-C-R 677 5001 ELIM EXT PAV MRK & MRKR (100 MM) 677 5002 ELIM EXT PAV MRK & MRKR (150 MM) 677 5005 ELIM EXT PAV MRK & MRKR (450 MM) 677 5006 ELIM EXT PAV MRK & MRKR (600 MM) 677 5007 ELIM EXT PAV MRK & MRKR (ARROW) 677 5008 ELIM EXT PAV MRK & MRKR (WORD) 678 5015 PAV SURF PREP FOR MRK (BLAST CLN)100MM EA 20.000 74 EA 160.000 75 EA 80.000 76 M 1,101.000 77 M 508.400 78 M 18.000 79 M 94.300 80 EA 9.000 81 EA 6.000 82 M 1,327.000 83 8-14
. 678 5016 PAV SURF PREP FOR MRK (BLAST CLN)150MM 678 5019 PAV SURF PREP FOR MRK (BLAST CLN)450MM 678 5021 PAV SURF PREP FOR MRKS (BLAST CLN)(ARW) 678 5022 PAV SURF PREP FOR MRKS (BLAST CLN)(WRD) 678 5031 PAV SURF PREP FOR MKS(BLST CLN)DBL ARRW 680 5001 004 INSTAL OF HWY TRAF SIG (ISOLATED) M 1,056.500 84 M 156.600 85 EA 21.000 86 EA 11.000 87 EA 2.000 88 EA 1.000 89 682 5009 BACK PLATE (3 SEC) (300 MM) 682 5010 BACK PLATE (4 SEC) (300 MM) 682 5011 BACK PLATE (5 SEC) (300 MM) EA 25.000 90 EA 1.000 91 EA 2.000 92 9-14
. 682 5013 LOUVER (7 DEG) (300 MM) EA 14.000 93 682 5023 VEH SIG SEC (300 MM)(W/O LENS & REFL) 682 5024 PED SIG SEC (2 IND/1 SEC)W/O LENS&REFL 684 5005 TRAF SIG CBL (TY A)(5 CONDR)(12 AWG) 684 5007 TRAF SIG CBL (TY A)(7 CONDR)(12 AWG) 684 5010 TRAF SIG CBL (TY A)(10 CONDR)(12 AWG) 684 5012 TRAF SIG CBL (TY A)(12 CONDR)(12 AWG) 684 5020 TRAF SIG CBL (TY A)(20 CONDR)(12 AWG) 684 5043 TRAF SIG CBL (TY C) (2 CONDR)(12 AWG) 684 5046 TRAF SIG CBL (TY C) (2 CONDR)(18 AWG) 684 5052 TRAF SIG CBL (TY A)(5 CONDR)(16 AWG) EA 89.000 94 EA 12.000 95 M 233.800 96 M 123.600 97 M 81.000 98 M 81.000 99 M 175.000 100 M 1,975.500 101 M 1,119.000 102 M 102.000 103 10-14
. 684 5053 TRAF SIG CBL (TY A)(7 CONDR)(16 AWG) 686 5012 002 TRAF SIG POLE ASM (STL)1 ARM (11.0 M) 686 5015 002 TRAF SIG POLE ASM (STL)1 ARM (14.6 M) 686 5070 002 TRAF SIG POLE ASM (STL)1 ARM(11.0 M)LUM M 3.000 104 EA 1.000 105 EA 4.000 106 EA 2.000 107 688 5001 PED DETECT (PUSH BTN) 688 5011 VEH DETECT (SAWCUT) EA 26.000 108 M 1,108.000 109 5003 5001 BALED HAY FOR EROSN & SEDMT CONT 5003 5003 BALED HAY FOR EROSN & SED CONT (REMOV) EA 10.000 110 EA 10.000 111 5012 5001 TEMP SEDMT CONT FENCE M 96.600 112 5012 5002 TEMP SEDMT CONT FENCE (REMOV & REPLAC) M 20.000 113 11-14
. 5012 5003 TEMP SEDMT CONT FENCE (REMOV) 5421 5005 ADJUST WWMH W/610 MM (24") LID M 96.600 114 EA 1.000 115 5421 5006 INVESTIGATION EA 2.000 116 5421 5007 ER WTR VALVE COVERS & STACK 5421 5009 ER WWMH W/610 MM (24") LID EA 1.000 117 EA 1.000 118 5421 5011 150 MM (6") GATE VALVE EA 1.000 119 5421 5012 REPL EXIST FIRE HYDRANT TO FINAL GRADE 5421 5013 TRENCH SAFETY AND SUPPORT EA 1.000 120 M 120.000 121 5421 5014 SAND BACKFILL 5421 5015 ROCK FOUNDATION M3 16.000 122 M3 2.000 123 12-14
. 5421 5016 FOUR "F" FLOWABLE BACKFILL 5421 5017 305MM (12") PVC WATER PIPE WITH PAVING M3 11.000 124 M 140.000 125 5421 5018 CLASS "B" CONCRETE 5421 5019 WATER SERVICE 5421 5020 305 MM (12") GATE VALVE M3 3.000 126 EA 1.000 127 EA 1.000 128 5421 5021 DISP OF HEAVY CHLORINATED WATER MAIN F LS 1.000 129 5421 5022 EROSION CONTROL LS 1.000 130 5421 5023 406 MM(16") X305 MM(12")TAPPING SLEEV EA 1.000 131 5421 5024 CAST IRON FITTINGS 5477 5001 DESKTOP MICROCOMPUTER MGR.630 132 EA 1.000 133 13-14
. 5477 5002 PRINTER 5477 5003 INTERNET SERVICE PROVIDER 6008 5001 SALV TRAF SIGNALS EA 1.000 134 EA 1.000 135 EA 2.000 136 6298 5001 300 MM LED TRAF SIGNAL LAMP (RED) 6298 5002 300 MM LED TRAF SIGNAL LAMP (YELLOW) 6298 5003 300 MM LED TRAF SIGNAL LAMP (GREEN) 6298 5004 300 MM LED TRAF SIGNAL LAMP (YEL ARW) 6298 5005 300 MM LED TRAF SIGNAL LAMP (GRN ARW) 6554 5001 LED PED SIG LAMP(SYMB)(2 IND/1 SEC) EA 29.000 137 EA 23.000 138 EA 23.000 139 EA 7.000 140 EA 7.000 141 EA 12.000 142 6607 5001 PEDESTAL POLE ASSEM EA 2.000 143 14-14