BGD278 Series BASOTROL CE Approved Gas Valve

Similar documents
BGD258 Series BASOTROL CE Approved Class A Gas Valve

G96 Series BASOTROL Dual Operator Valve

B21 Series BASOTROL Gas Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

H15 Series BASO Automatic Shutoff Pilot Gas Valve

H15 Series BASO Automatic Shutoff Pilot Gas Valve

Y75 Series Sensing Probes

Y75 and D Series Sensing Probes

J Series Pilot Burners/Y90 Series Inlet Fittings

G76x Direct Spark Ignition Controls

Electrically Operated. Gas Valves. Thermocouple Operated. Gas Valves Accessories Ignition Control Modules Pilot Burners PRODUCT CATALOG 2017

G861 Series Integrated Function. Direct Spark Ignition Control

G72x Series Direct Spark Ignition Controls

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Old documentation - Only for your information! Product is not available any more!

Electro- Hydraulic Actuator Gas Valves GH-5000

CATALOG. 2 nd Edition

BG1600M Intermittent Pilot Ignition Control

GV30 / GV30A SERIES GAS COMBINATION CONTROL SYSTEMS FOR COMMERCIAL COOKING APPLIANCES.

36H Gas Control Product Information

Product Information. 16 Series ROSS CONTROLS

G600 Series Replacement Intermittent Pilot Ignition Controls

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

P77 Series. Single Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications. Product Bulletin

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

Flare Valves 1/2 inch 2-Way and 3-Way

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Q35 Series Automatic Vent Damper System

Service and installation must be performed by a trained/experienced service technician.

Series 44 Installation Instructions

Product Information ROSS CONTROLS

P70, P72, and P170 Controls for Low Pressure Applications

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

Compact Valves 16 Series

Series 20 Installation Instructions

BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control

GEMINI GAS CONTROL PRODUCT INFORMATION

Service and installation must be performed by a trained/experienced service technician.

SERIES 2000 GAS SAFETY SHUT OFF VALVE

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

M x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators

Installation, Operation and Maintenance. VA(M)S24-27 (T)-T Series Actuator

P66 Series Electronic Fan Speed Controls

P70, P72 and P170 Series Controls for High Pressure Applications

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

A419ABG-3C Electronic Temperature Control

Natural Gas Reference Guide

Pilot Operated 2 Port Solenoid Valve for Dry Air

Valve monitoring system VDK 200 A S02

System 350 P352AB Electronic Pressure Control Series

V5000. Globe Valves Series for Terminal Units. Product Bulletin

AV-8020 Series Floating Control Actuated Valve

Product Information. L-O-X 15 Series ROSS CONTROLS

VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators

NV Direct Coupled Globe Valve Actuator

Product Information. 36 & RM Series ROSS CONTROLS

VG6000 Series Forged Brass Valves

ROSS CONTROLS. Compact Valves 16 Series.

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

2-Way & 3-Way Non Spring Return Characterized Ball Valves

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

P70, P72, and P170 Series Controls for High Pressure Applications

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

VA-4233-GGx Series Electric Valve Actuators

Type Type 1001 Transducers. I/P & E/P Transducers

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

VA-8020 Floating Valve Actuator

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

Manually operated safety shut-off valve HSAV HSAV/5

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Solenoid valves for gas VAS, Double solenoid valves VCS

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Features Globe Valve 2-Way & 3-Way Assembly Features:

Product Information. W66 Series ROSS CONTROLS

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

Eclipse RatioAir Burners

CATALOG. 2 nd Edition

VG7000 Series Bronze Control Valves

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

VG8000N Series PN16, DN15 - DN150

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

Transcription:

Product Bulletin Issue Date November 16, 2012 BGD278 Series BASOTROL CE Approved Gas Valve The BGD278 Series gas valve is a combination main and pilot valve intended for use in conjunction with solid-state sequence control units on direct burner or intermittent pilot ignition systems. The BGD278 valve can be used with natural gas, Liquefied Petroleum (LP) gas and LP-air mixed gas. Typical applications include heaters, process burners, commercial dryers, commercial cooking equipment, rooftop units and similar applications. Figure 1: BGD278 CE Approved Gas Control Valve Features and Benefits Optional Pressure Regulator Convertible Pressure Regulator Compact Size Multiple Operating Voltages Provides field-adjustable flow control for range-rated applications Permits use with LP gas or natural gas Permits installation in space-restrictive applications Provide the flexibility to suit market requirements 2012 BASO Gas Products 1 Code No. BASO-PB-BGD278, Rev. E www.baso.com

Overview Valve Operation The BGD278 is a twin on/off valve with springloaded seat discs that are operated by Class B solenoids with protected rectifiers to ensure quiet operation. When the valve is energized, the solenoid plunger is pulled into the coil, overcoming the force of the closeoff spring and the flow medium pressure. The valve seat discs are directly fixed to the plunger stem so the valve fully opens. Valve Configurations The BGD278 series offers twin solenoid models. Twin solenoid models allow independent opening of both valve seats. Adjustment Methods The BGD278 series offers models with no adjustment, top or bottom adjust regulator control. No Adjustment The BGD278 A model has a blank plate mounted onto the bottom of the body casting for applications where adjustment control is not needed or for applications where separate adjustment control is already provided. Regulator Adjustment The BGD278 D and E models have a top adjust spring pressure regulator. These models have either a right- or left-handed top adjust pressure regulator. Right- or left-hand orientation is determined by the position of the adjustment when looking into the inlet connection of the valve. (Refer to the Ordering Information section for details.) The BGD278 B and C models have a bottom adjust spring pressure regulator. Adjustment of the regulator is made from the bottom of the valve when the valve is in the upright position (solenoid coils on top). The regulator controls the gas pressure at the valve outlet by positioning the regulator poppet for a selected throughput flow and pressure. This is achieved by the valve outlet pressure acting on the regulator diaphragm, which balances against the preset regulator spring. Adjustment of the spring compression determines the valve outlet pressure and the throughput flow rate. Range of Regulation Pressure Regulator Models BGD278 models with an adjustable top or bottom adjust pressure regulator have the following pressure range: Natural gas: 7.5 to 15 mbar (0.75 to 1.5 kpa [3 to 6 in. W.C.]) LP gas: Top Adjust 15 to 30 mbar (1.5 to 3.0 kpa [6 to 12 in. W.C.]) Bottom Adjust 20 to 30 mbar (2.0 to 3.0 kpa [8 to 12 in. W.C.]) Table 1: Range of Regulation (ANSI Z21.78) for Pressure Regulator Models Valve Model Q minimum Q maximum m 3 /h cf/h m 3 /h cf/h BGD278 D and E 0.6 20 5.7 200 BGD278 B and C 0.6 20 5.7 200 Note: 1 m 3 /h - 10.67 kw (1 cf/h = 1,000 Btu/h) natural gas at 0.64 specific gravity. Accessories If you desire to measure the outlet pressure, use the bottom cast pressure test fitting or use the Y99AX pressure test fitting (see Figure 2) and an approved pipe joint compound on the male threads and screw the fitting into either side of the valve, which ever side is convenient, replacing the pressure tap plug. Figure 2: Y99AX-1 (1/8-27 NPT) Pressure Test Fitting Y99AX-2 (1/8-28 BSPT) Pressure Test Fitting Table 2: Accessories Description Part Number Conversion Kit for Regulation to Y71AA-5 Non-regulation LP to Natural Gas Conversion Kit for 7.5 to 15 mbar (0.75 to 1.5 kpa/ Y71QH-2 3 to 6 in. W.C.) Regulation Natural Gas to LP Conversion Kit for 15 to 30 mbar (1.5 to 30 kpa/ Y71GF-4 6 to 12 in. W.C.) Regulation LP to Natural Gas Conversion Kit for 7.5 to 15 mbar (0.75 to 1.5 kpa/ Y71QH-3 3 to 6 in. W.C.) Regulation Natural Gas to LP Conversion Kit for 20 to 30 mbar (2.0 to 30 kpa/ Y71GF-3 8 to 12 in. W.C.) Regulation 2 BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin

Dimensions 41.4 1.632 80.1 3.154 Turning Radius 79.8 3.140 121.7 4.790 112.2 4.419 87.6 3.448 Figure 3: Top Adjust Regulator Dimensions, mm 41.4 1.632 80.1 3.154 Turning Radius 79.8 3.140 146.3 5.759 (in.) 112.2 4.419 Figure 4: Bottom Adjust Regulator Dimensions, mm (in.) BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin 3

41.4 1.632 80.1 Turning 3.154Radius 79.8 3.140 110.9 4.366 112.2 4.419 Figure 5: No Regulator Dimensions, mm (in.) Mounting The BGD278 valve may be mounted on a horizontal manifold with the solenoid coils pointed up (vertical) or in any position not exceeding 90 from the vertical. The valve may also be mounted on a vertical manifold in any position around its axis (see Figure 6). Do not install the solenoid coils upside down. Install vertically wherever possible. 90 Maximum from Vertical Limited Horizontal and Vertical No Regulator Vertical mounting may be 360º around its axis with the gas flow either up or down, but always in the direction of the arrow. 90 Maximum from Vertical Figure 6: BGD278 Valve Mounting Position Wiring The BGD278 valve is supplied with 3-tab or 2-tab electrical connections. The tabs of the solenoid coil are male and electrical connections should be made using 6.35 x 0.8 mm (1/4 in.) female, fully insulated push-on terminals. The earth ground tab is clearly labeled with the earth ground symbol. The electrical wiring to a twin solenoid valve from an electronic intermittent proven pilot ignition system is comprised of two lines; a common and an independent earth ground. Wiring can be done using a single 4-wire cable. The wiring connections for a 4-wire cable are shown in Figure 7. Route the electrical cable for the valve solenoid from the burner sequence control to the valve and make wiring connections in accordance with Figure 7. Note: Electrical connections can also be made using pre-wired electrical plugs (DIN 43650 [ISO 4400]). All wiring must be in accordance with national and local electrical codes and regulations. Repair and Replacement Table 3: Replacement Solenoid Coil Part Number Description RSDA16A-12 12 VDC; 50/60 Hz; 2-tab 15 VA Coil RSDA16A-25 25 VAC; 50/60 Hz; 3-tab 15 VA Coil RSDA16A-25A 25 VAC; 50/60 Hz; 2-tab 15 VA Coil RSDA16A-25V 25 VDC; 2-tab 17 VA Coil RSDA16A-120 120 VAC; 50/60 Hz; 3-tab 15 VA Coil RSDA16A-240 240 VAC; 50/60 Hz; 3-tab 15 VA Coil Field repairs must not be made to the BGD278 valve. For a replacement valve, contact the original equipment manufacturer or the nearest BASO Gas Products distributor. 4 BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin

Earth Ground Line 2 Neutral Line 1 L2 N2 N1 L1 Coil 2 Main Valve Coil 1 Pilot Valve Twin Solenoid Wiring Using 4-Wire Cable Non-Polarity Sensitive Line and Neutral Connections Ground Tab 25 VDC, 25V, 120V and 240V Only Non-Polarity Sensitive Line and Neutral Connections Ground Tab 25 VDC, 25V, 120V and 240V Only To Pilot Solenoid To Main Solenoid L N L N Figure 7: 3-Tab Electrical Connections BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin 5

Ordering Information B G D 2 7 8 _ - See the next page for Customer Specific Requirements. A = D = E = Regulation Configuration No Adjustment Bottom Adjustment (LP Gas) Bottom Adjustment (Natural Gas) Top Adjustment (LP Gas) Top Adjustment (Natural Gas) E = F = G = H = K = Solenoid Rating 12 VDC, 15 VA 25 VAC, 50/60 Hz, 15 VA 120 VAC, 50/60 Hz, 15 VA 240 VAC, 50/60 Hz, 15 VA 25 VDC, 17 VA E = F = H = J = L = M = N = P = R = T = V = X = Capacity @ 1 W.C. Pressure Drop Rating Btu/hr kw Inlet and Outlet (Strainer) 1/2-14 x 1/2-14 NPT (With Inlet Strainer) 1/2-14 x 3/4-14 NPT (With Inlet Strainer) 1/2-14 x 1/2-14 BSPP (With Inlet Strainer) 1/2-14 x 3/4-14 BSPT (With Inlet Strainer) 1/2-14 x 1/2-14 NPT (Without Inlet Strainer) 1/2-14 x 3/4-14 NPT (Without Inlet Strainer) 1/2-14 x 1/2-14 BSPP (Without Inlet Strainer) 1/2-14 x 3/4-14 BSPT (Without Inlet Strainer) 3/4-14 x 3/4-14 NPT (With Inlet Strainer) 3/4-14 x 3/4-14 BSPT (With Inlet Strainer) 3/4-14 x 3/4-14 NPT (Without Inlet Strainer) 3/4-14 x 3/4-14 BSPT (Without Inlet Strainer) 1/2-14 x 1/2-14 BSPT (With Inlet Strainer) 1/2-14 x 1/2-14 BSPT (Without Inlet Strainer) Figure 8: BGD278 Valve Ordering Matrix 6 BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin

Ordering Information (Continued) B G D 2 7 8 _ - D = Packaging Configuration Individual Pack Bulk Pack ( 32 per carton) A = D = E = F = G = H = J = K = L = M = N = P = R = T = U = V = W = X = Pressure Tap Connections None 1/8-27 NPT Left 1/8-27 NPT Right M5 x 0.8 Bottom 1/8-27 NPT Left and M5 x 0.8 Bottom 1/8-27 NPT Right and M5 x 0.8 Bottom 1/8-27 NPT Left and Right 1/8-27 NPT Left, Right and M5 x 0.8 Bottom 1/8-28 BSPP Left 1/8-28 BSPP Right 1/8-28 BSPP Left and M5 x 0.8 Bottom 1/8-28 BSPP Right and M5 x 0.8 Bottom 1/8-28 BSPP Left and Right 1/8-28 BSPP Left, Right, and M5 x 0.8 Bottom 1/8-28 BSPT Left 1/8-28 BSPT Right 1/8-28 BSPT Left and M5 x 0.8 Bottom 1/8-28 BSPT Right and M5 x 0.8 Bottom 1/8-28 BSPT Left and Right 1/8-28 BSPT Left, Right, and M5 x 0.8 Bottom Pilot Tap Connections A = None 1/8-27 NPT Left 1/8-27 NPT Right D = 1/4 in. cc Fitting Bottom E = 1/8-27 NPT Left and 1/4 in. cc Fitting Bottom F = 1/8-27 NPT Right and 1/4 in. cc Fitting Bottom G = 1/8-27 NPT Left and Right H = 1/8-27 NPT Left, Right, and 1/4 in. cc Fitting Bottom J = 1/8-28 BSPP Left K = 1/8-28 BSPP Right L = 1/8-28 BSPP Left and 1/4 in. cc Fitting Bottom M = 1/8-28 BSPP Right and 1/4 in. cc Fitting Bottom N = 1/8-28 BSPP Left and Right P = 1/8-28 BSPP Left, Right, and 1/4 in. cc Fitting Bottom R = 1/8-28 BSPT Left T = 1/8-28 BSPT Right U = 1/8-28 BSPT Left and 1/4 in. cc Fitting Bottom V = 1/8-28 BSPT Right and 1/4 in. cc Fitting Bottom W = 1/8-28 BSPT Left and Right X = 1/8-28 BSPT Left, Right & 1/4 in. cc Fitting Bottom A = Regulation Configuration Bottom or Non-Adjust Left Right A = Solenoid Connections Din no. 43650 Form B Ind. (Tabs Facing Left) Din no. 43650 Form B Ind. (Tabs Facing Right) Din no. 43650 Form B Ind. (Tabs Facing Inlet and Outlet) Number Customer Specific Requirements Figure 9: BGD278 Valve Ordering Matrix BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin 7

Technical Specifications Product BGD278 Series BASOTROL CE Approved Gas Valve Types of Gas 2nd (Natural Gas), and 3rd (LP Gas) Family Gases Permissible Ambient -29 to 79 C (-20 to 175 F ) (Surface) Temperature Electrical Ratings 12 VDC, 1.0A 25 VDC, 0.675A 25 VAC, 50/60 Hz, 0.595A 120 VAC, 50/60 Hz, 0.13A 240 VAC, 50/60 Hz, 0.063A Rated Inlet Pressure North America: Europe: Australia: 0.5 psi 35 mbar 3.5 kpa Maximum Working Pressure (CE) 100 mbar Maximum Differential 20 mbar (2 kpa [8 in. W.C.]) Pressure Reverse Pressure Ratings 50 mbar (5 kpa [20 in. W.C.]); Class B (EN 126 and 161); Class 2 (AS 4624 and AS 4629) Regulator Classification Class C (EN 126); Adjustable, Class 2, Grade 20 (AS 4624) Regulator Setting Factory set to customer s specification Regulator Adjustment Range Body Connections Bottom Adjust Regulators: 7.5 to 15 mbar (0.75 to 1.5 kpa [3 to 6 in. W.C.]) 20 to 30 mbar (2.0 to 3.0 kpa [8 to 12 in. W.C.]) Top Adjust Regulators: 7.5 to 15 mbar (0.75 to 1.5 kpa [3 to 6 in. W.C.]) 15 to 30 mbar (1.5 to 3.0 kpa [6 to 12 in. W.C.]) 1/2 NPT, 1/2 BSPP (Thread ISO 7-Rp); or 1/2 BSPT (Thread ISO 7-Rc) with Flange Connection Holes (M4 x.07 mm pitch x 6 mm deep) 3/4 NPT or 3/4 BSPT (Thread ISO 7-Rc) Valve Torsion Group Group 2 (EN 126 and EN 161) Pressure Connection 1/8 BSPP (Thread ISO 7-Rp), 1/8 BSPT (Thread ISO 7-Rc), 1/8 NPT Left-hand and/or Right-hand, or M5 x 0.8 Bottom Pilot Connections 1/8 BSPP (Thread ISO 7-Rp), 1/8 BSPT (Thread ISO 7-Rc), 1/8 NPT Left-hand and/or Right-hand, or 1/4 in. cc Fitting Bottom Dirt Strainer 0.036 in. (0.9 mm) Mesh (CE only or upon request) Operating Time Rating 100% Continuous Valve Timings Closing Time Opening Time Dead Time <1 Second <1 Second <1 Second Power Ratings 15 VA per Coil (except 25 VDC, 17 VA) Electrical Connections Coil Insulation Class Type of Gas Packaging Bulk Pack Quantity Bulk Pack Weight 3-Tab Solenoid Coil 2-Tab Solenoid Coil Class F 2 x 1/4 in (6.35 mm) + 1/4 in. (6.35 mm) Earth Ground 2 x 1/4 in. (6.35 mm) 2nd (Natural Gas), and 3rd (LP Gas) Family Gases Bulk pack supplied to original equipment manufacturer (individual pack optional). 32 per carton 37 kg (82 lb) per carton 8 BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin

Technical Specifications (continued) Agency Listings CSA (AGA/CGA) Certificate Number 229521-16041 EC Type Examination Certificate Number EC-87/94/058 Australian Gas Association Certificate Number 7934 Specification Standards EN 126 and EN 161 Standards Complying with EMC Directive Standards Complying with Low Voltage Directive Australian Standards AS 4624 and AS 4629 ANSI Standards Z21.21 and Z21.78 Canadian Standards CSA 6.5 and CSA 6.20 Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or misuse of its products. Refer to the BGD278 Series CE Approved Gas Valve Product Bulletin (BASO-PB-BGD278) for necessary information on operating and performance specifications of this product. 1007 South 12th Street PO Box 170 Watertown, WI 53094 www.baso.com 1-877-227-6427 (1-877-BASOGAS) Printed in U.S.A. BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin 9