DRV2-080 Adjustable, Direct-Acting Relief Valve

Similar documents
Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Directional Control Valves

Proportional Valves. Proportional solenoid valves for pressure and flow control

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Pressure Control Valves

P.C. Priority Flow Control Valve Series J02D3. General Description

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Directional Control Valves. General Description. Features. Specifications

Pressure Control Valves

CVH103P. Check Valve Series CVH103P. Technical Information. General Description

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm)

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

Proportional Flow-Control Cartridges, Size 5

Standard Coils and Proportional Valve Coils

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

EVP SERIES PROPORTIONAL CONTROL VALVES

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

COILS DELTA POWER COMPANY

High Pressure Solenoid Valves

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L

D05 Directional Control Valves

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Solenoid Coils for Switching and Proportional Valves

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Cartridge Valves Technical Information Directional Valves DCV 03

2/2 Solenoid Cartridge Valve, Size 10

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

SV SOLENOID OPERATED

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

Directional Control Valve Series D3W Soft Shift

Direct solenoid and solenoid pilot operated valves

PILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series

5-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow, for two pumps systems

PILOT OPERATED PRESSURE RELIEF VALVE SERIES - IN-LINE MOUNTING

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves. General Description. Operation. Features

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)

SKINNER Intrinsically Safe Series Four-Way

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

Nominal sizes 08 to 10, special cavities

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

6 to14/2 ways/positions bankable flow diverters flangeable

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Series PD directly operated solenoid valves

Full Range Pressure Compensating Variable Flow Control

PRESSURE CONTROLS TECNORD

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10

6/2 ways/positions flow diverters

6 to14/2 ways/positions bankable flow diverters flangeable

EI, EIO INTRINSICALLY SAFE VALVES

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES

Directional Control Valves. Features. Application. Operation

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1...

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

6 to 12/2 ways/positions bankable flow diverters flangeable

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

3/2 ways/positions flow diverters

6 to14/2 ways/positions bankable flow diverters flangeable

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Available manual, pneumatic, and hydraulic spool control kits.

PowrFlow PVX Vane Pumps

2/2 Solenoid Cartridge Valve, Size 6

6/2 ways/positions flow diverters

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

Series PD directly operated solenoid valves

Catalog PowrFlowTM PVX Vane Pumps

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

Pressure Control Valves. General Description. Specifications. Ordering Information

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

Electrically Operated Pressure Reducing Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WDRVPA 5...

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

D SERIES HYDRAULIC PUMP

Transcription:

SOLENOID DRV2-080 Adjustable, Direct-Acting Relief Valve SERIES 8 CHECK MOTION FLOW USASI / ISO ➁ ➀ DESCRIPTION An adjustable, direct-acting poppet cartridge valve designed to limit pressure in hydraulic circuits. OPERATION The DRV2-080 prevents flow from ➀ to ➁ until the set crack pressure at ➀ is achieved. The poppet then unseats allowing flow from ➀ to ➁ protecting the circuit from over pressurization. RELIEF PRESSURE SEQUENCE SHUTTLE DIRECTIONAL VALVES ACCESSORIES TECHNICAL DATA PRESSURE DROP psi (bar) ➀ ➁ PRESSURE DROP VS. FLOW 3000 (206.9) 2500 (172.4) 2000 (137.9) 1500 (103.4) 1000 (69.0) 500 (34.5) 0 0 150 ssu/32 cst OIL @ 100 F./38 C. 2.0 (7.6) 4.0 (15.1) 6.0 (22.7) FLOW gpm (L/min.) 8.0 (30.3) 10.0 (37.9) FEATURES and BENEFITS Quiet operation. Rapid response to pressure surges. Hardened poppet and seat for long life. Aluminum knob and disc nut option. Adjustment may be locked in place. Adjustment prevents spring from going solid. Industry common cavity. Compact size. SPECIFICATIONS Operating Pressure: 3000 PSI (207 Bar) Flow: See PRESSURE DROP VS. FLOW graph. Internal Leakage: 20 drops/min. max. at reseat. Crack Pressure Defined: Determined at.25 gpm (0.9 L/min.) Reseat Pressure: Nominal 80% of crack pressure. Spring Ranges: 100 to 400 PSI ( 7 to 28 Bar) Preset: 300 PSI ( 21 Bar) 300 to 2000 PSI ( 21 to 138 Bar) Preset: 1500 PSI (103 Bar) 1500 to 3000 PSI (103 to 207 Bar) Preset: 2500 PSI (172 Bar) Temperature: -30 F to +250 F (-35 C to +120 C). Recommended Filtration: ISO 20/18/14 Fluids: Mineral-based fluids. For other fluid compatibility, consult factory. Cavity/Cavity Tool: 080-2, see page 11.08.2 Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar). 5.02.1

INSTALLATION DIMENSIONS SCREW ADJUSTMENT.19 (4.8) HEX. SOCKET 2.88 (73.2) MAX. 1.09 (27.7) ( ) Parentheses = Millimeters HOW TO ORDER RELIEF VALVE ➀ CAVITY/SEAL ➁ DRV2-080 - * - * - *** / **** - ** SEALS N = Buna-N V = Viton KNOB ADJUSTMENT 1.50 (38.1) DIA. KNOB.88 (22.4) HEX. TORQUE 20 FT.-LBS. (27.1 Nm) MAX. ADJUSTMENT STYLE K = Knob S = Screw 1.50 (38.1).28 TYP. (7.1).13 (3.3) ➀ 1.25 (31.8) 1.63 (41.4) 2.00 (50.8) ➁ DRV2-080 Adjustable, Direct-Acting Relief Valve 4.88 (124.0) MAX. 1.13 (28.7) SERIES 8.59 (15.0).56 (14.2) 2.00 (50.8) PORTING 2N = 1/4 PTF 3N = 3/8 PTF 4T = SAE 4 6T = SAE 6 Omit for Cartridge Only. (Other porting options available consult factory.) FACTORY PRESET PSI (Omit for standard) SPRING RANGES 4 = 100 to 400 PSI ( 7 to 28 Bar) Preset: 300 PSI ( 21 Bar) 20 = 300 to 2000 PSI ( 21 to 138 Bar) Preset: 1500 PSI (103 Bar) 30 = 1500 to 3000 PSI (103 to 207 Bar) Preset: 2500 PSI (172 Bar) SOLENOID CHECK MOTION FLOW RELIEF PRESSURE SEQUENCE SHUTTLE DIRECTIONAL ACCESSORIES TECHNICAL VALVES DATA 5.02.2

SOLENOID DSV2-080-2NOP Normally-Open, Two-Way, Two-Position, Poppet-Type Solenoid Valve SERIES 8 CHECK MOTION USASI ➁ ➀ ISO ➁ ➀ DESCRIPTION A cartridge valve designed with positive shut off to be used in load holding applications. OPERATION FLOW When de-energized, the DSV2-080-2NOP poppet is open to allow flow from ➁ to ➀. RELIEF When energized, the poppet closes to block flow from ➁ to ➀. In this condition, the cartridge allows reverse flow from ➀ to ➁ after overcoming the solenoid force of 75 PSI (5 Bar). PRESSURE SEQUENCE ➀ ➁ FEATURES and BENEFITS Continuous-duty solenoid. Hardened poppet and plunger for long life and low leakage. Efficient wet-armature construction. Cartridges are voltage interchangeable. Optional coil voltages and terminations. Filter screen standard. Industry common cavity. Compact size. SHUTTLE SPECIFICATIONS DIRECTIONAL VALVES ACCESSORIES TECHNICAL DATA PRESSURE DROP psi (bar) PRESSURE DROP VS. FLOW 125 (8.6) 100 (6.9) 75 (5.2) 50 (3.4) 25 (1.7) 0 0 ➁ 1.0 (3.8) ➀ TO (DE-ENERGIZED) 150 ssu/32 cst OIL @ 100 F./38 C. 2.0 (7.6) 3.0 (11.4) FLOW gpm (L/min.) 4.0 (15.1) 5.0 (18.9) Operating Pressure: 3000 PSI (207 Bar) Flow: See PRESSURE DROP VS. FLOW graph. Internal Leakage: 5 drops/min. max. at 3000 PSI (207 Bar) Temperature: -30 F to +250 F (-35 C to +120 C) Coil Rating: Continuous from 85% to 110% of rated voltage. Current Draw: 12 VDC is 1.3 amps. Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar) Response Time: 80% of final change of state with 100% voltage supplied at 100% of nominal flow rating. Pull-In: 12 VDC 25 m. sec. Drop-Out: 12 VDC 30 m. sec. Recommended Filtration: Critical Application-ISO 17/15/13 Non-Critical Application-ISO 20/18/14 Fluids: Mineral-based fluids. For other fluid compatibility consult factory. Cavity/Cavity Tool: 080-2, see page 11.08.2 Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar). 1.08.1 10152-80 02/08

INSTALLATION DIMENSIONS 2.16 (54.9) 1.08 (27.4) ➀ ➁.88 (22.4) HEX. TORQUE 20 FT.-LBS. (27.1 Nm) MAX. FILTER 250 NOM. MICRON (EFFECTIVE FROM ➁TO ➀ONLY) ( ) Parentheses = Millimeters HOW TO ORDER SOLENOID VALVE CAVITY/SEAL FLOW PATH NORMALLY OPEN.75 (19.1) HEX TORQUE 40 IN.-LBS. (4.5 Nm ) MAX. 1.50 (38.1).28 TYP. (7.1) Omit coil for cartridge only with nut. Other porting and coil options available consult factory..13 (3.3) ➀ 1.25 (31.8) 1.63 (41.4) 2.00 (50.8) DSV2-080 - 2 NO P - * - **** - ** POPPET SEALS N=BunaN V = Viton D=DC A=AC DSV2-080-2NOP Normally-Open, Two-Way, Two-Position, Poppet-Type Solenoid Valve ➁ SERIES 8 4.16 (105.7).59 (15.0) 1.13 (28.7).56 (14.2) 2.00 (50.8) PORTING 2N = 1/4 PTF 3N = 3/8 PTF 4T = SAE 4 6T = SAE 6 Omit for Cartridge Only COIL CONNECTION DS = Double Lead SS = Single Lead H = Hirschmann CS = Conduit BS = Double Spade ES = Single Stud US = Deutsch VOLTAGE 1 = 12 Volt 2 = 24 Volt 5 = 120 Volt 6 = 240 Volt 9 = 20 Volt 10 = 10 Volt SOLENOID CHECK MOTION FLOW RELIEF PRESSURE SEQUENCE SHUTTLE DIRECTIONAL ACCESSORIES TECHNICAL VALVES DATA 1.08.2

SPECIFICATIONS Wattage: 10 volts: nominally 19 watts at 68 F./20 C. 12, 20, 24, 120 and 240 volts: nominally 22 watts at 68 F./20 C. Duty Rating: Continuous at 100% voltage. Ambient Operating Temperature: 212 F/100 C continous at nominal voltage. Encapsulating Material: Theroplastic Polyester (PET). A.C. Coils: Internally rectified with a full wave bridge (no inrush current). Termination Options: See below and on the next page. DOUBLE LEADS CODE - **D VOLTS PART NO. LEAD COLOR 10 DC 10163-99 GREEN 12 DC 10162-76 RED 20 DC 10223-97 RED 24 DC 10162-77 BLUE 120 AC 10162-82 BLACK 240 AC 10162-83 YELLOW LEAD WIRES: 18/20 GAUGE MEETS SAE J1128 XLPE, TYPE SXL. SINGLE LEAD CODE - **S VOLTS PART NO. LEAD COLOR 10 DC 10164-12 GREEN 12 DC 10164-10 RED 24 DC 10164-11 BLUE LEAD WIRES: 18/20 GAUGE MEETS SAE J1128 XLPE, TYPE SXL. HIRSCHMANN CODE - **H VOLTS PART NO. 10 DC 10164-02 12 DC 10162-78 24 DC 10162-79 120 AC 10162-84 240 AC 10162-85 VOLTS TERMINATION: HIRSCHMANN GSR 200 (2 POLE + GROUND APPLIANCE PLUG) MATING CONNECTOR 43650 Solenoid Coil Data OHMS SERIES 10 19 WATT 22 WATT INITIAL CURRENT DRAW (AMPS) OHMS INITIAL CURRENT DRAW (AMPS) 10 DC 5.3 1.9 12 DC 6.5 1.83 20 DC 18.2 1.10 24 DC 26.1.92 120 AC 496.18 240 AC 1830.18 RESISTANCE CANNOT BE MEASURED ON AC COIL ASSEMBLIES 1.50 (38.1) 2.00 (50.8) 1.50 (38.1) 2.00 (50.8) 1.50 (38.1) 2.00 (50.8) 2.19 (55.6).88 (22.4) 18 GA..41 (10.4) 2.19 (55.6).88 (22.4).88 (22.4).41 (10.4) 18 GA. 2.38 (60.5) 14.00 (355.6) 1.00 (25.4) 14.00 (355.6) 1.00 (25.4).50 (12.7) SOLENOID CHECK MOTION FLOW RELIEF PRESSURE SEQUENCE SHUTTLE DIRECTIONAL ACCESSORIES TECHNICAL VALVES DATA 02/08 11.32.1

SOLENOID Solenoid Coil Data (continued) SERIES 10 CHECK CONDUIT (FEMALE 1/2-14 NPT) CODE - **C.88 (22.4) 2.38 (60.5).63 (16.0) MOTION FLOW VOLTS PART NO. LEAD COLOR 10 DC 10164-05 GREEN 12 DC 10162-80 RED 24 DC 10162-81 BLUE 120 AC 10162-86 BLACK 240 AC 10162-87 YELLOW 1.50 (38.1) 2.00 (50.8).75 (19.1) 24.00 (609.6) 18 GA. LEAD WIRES: 18/20 GAUGE MEETS SAE J1128 XLPE, TYPE SXL. RELIEF DOUBLE SPADE CODE - **B.88 (22.4) 2.19 (55.6) PRESSURE SEQUENCE VOLTS PART NO. 10 DC 10164-08 12 DC 10162-91 20 DC 10234-53 24 DC 10162-92 120 AC 10162-90 240 AC 10164-09 TERMINATION: 1/4 MALE QUICK-CONNECT PER SAE J858A (TYPE 1B) 1.50 (38.1) 2.00 (50.8).50 (12.7).38 (9.7) 1.00 (25.4) SHUTTLE SINGLE STUD CODE - **E DIRECTIONAL VALVES TECHNICAL DATA ACCESSORIES.88 (22.4) 2.25 (57.2) VOLTS PART NO. 10 DC 10164-15 12 DC 10164-13 24 DC 10164-14 TERMINATION: 10-32 MALE STUD WITH 2 BRASS NUTS AND 1 STEEL EXTERNAL TOOTH LOCKWASHER 1.50 (38.1) 2.00 (50.8).44 (11.2) 1.00 (25.4) 11.32.2 02/08

2008 Deltrol Catalog:Deltrol2004Run8 2/26/08 2:10 PM Page 221 SOLENOID Solenoid Coil Data SERIES 8 SPECIFICATIONS Wattage: Nominally 16 watt at 68 F./20 C. Ambient Operating Temperature: 212 F/100 C continous at nominal voltage. Encapsulating Material: Theroplastic Polyester (PET). A.C. Coils: Internally rectified with a full wave bridge (no inrush current). PART NO. LEAD COLOR 10 DC 12 DC 24 DC 120 AC 240 AC 10205-94 10184-42 10184-37 10184-49 10184-53 GREEN RED BLUE BLACK YELLOW PART NO. LEAD COLOR 10 DC 12 DC 24 DC 10194-19 10184-32 10190-44 GREEN RED BLUE DIRECTIONAL VALVES VOLTS TERMINATION: 1/4 MALE QUICK-CONNECT PER SAE J858A (TYPE 1B) ACCESSORIES DOUBLE SPADE CODE - **BS TECHNICAL DATA 10221-46 10216-12 10222-51 10216-11 10222-49 10222-50 RESISTANCE CANNOT BE MEASURED ON AC COIL ASSEMBLIES SHUTTLE SINGLE LEAD CODE - **SS 10 DC 12 DC 20 DC 24 DC 120 AC 240 AC 1.60 1.33.80.67.15.07 SEQUENCE FOR INTERNAL DIODE CONSULT FACTORY PART NO. 6.2 9.0 25.0 35.8 827 3306 PRESSURE VOLTS VOLTS 10 DC 12 DC 20 DC 24 DC 120 AC 240 AC RELIEF DOUBLE LEADS CODE - **DS INITIAL CURRENT DRAW (AMPS) FLOW Termination Options: See below and on the next page. OHMS MOTION Duty Rating: Continuous at 100% voltage. VOLTS CHECK 16 WATT FOR INTERNAL DIODE CONSULT FACTORY 02/08 11.31.1

SOLENOID Solenoid Coil Data (continued) RELIEF PRESSURE SHUTTLE DIRECTIONAL VALVES TECHNICAL DATA CHECK ACCESSORIES SEQUENCE MOTION SERIES 8 SINGLE SPADE CODE - **AS VOLTS PART NO. 10 DC 10222-46 12 DC 10221-30 24 DC 10221-47 TERMINATION: 1/4 MALE QUICK-CONNECT PER SAE J858A (TYPE 1B) FLOW SINGLE STUD CODE - **ES VOLTS PART NO. 10 DC 10196-60 12 DC 10196-61 24 DC 10196-62 TERMINATION: 8-32 MALE STUD WITH BRASS NUTS DEUTSCH CODE - **US VOLTS PART NO. 10 DC 10210-13 12 DC 10222-99 20 DC 10228-95 24 DC 10228-52 TERMINATION: INTEGRAL DEUTSCH CONNECTOR DT04-2P MATING CONNECTOR DT06-2S FOR INTERNAL DIODE CONSULT FACTORY 11.31.2 02/08

SOLENOID Solenoid Coil Features/Specifications CHECK MOTION RELIEF PRESSURE SEQUENCE TECHNICAL DATA ACCESSORIES DIRECTIONAL VALVES SHUTTLE FLOW STANDARD VOLTAGE: 10, 12, 20 AND 24 VOLTS D.C. 120 AND 240 VOLTS A.C. WATTAGE: SERIES 8: ALL COILS ARE NOMINALLY 16 WATTS AT 68 F./20 C. SERIES 10: 10 VOLT COILS ARE NOMINALLY 19 WATTS AT 68 F./23 C. 12, 20, 24, 120 AND 240 VOLT COILS ARE NOMINALLY 22 WATTS AT 68 F./20 C. DUTY RATING: CONTINUOUS AT 100% VOLTAGE. AMBIENT OPERATING TEMPERATURE: 212 F./100 C. CONTINUOUS AT NOMINAL VOLTAGE. MAGNET WIRE: ALL 100 SERIES ARE THERMAL CLASS 200 C., NEMA PUB, NO. MW1000 ENCAPSULATING MATERIAL: THEROPLASTIC POLYESTER (PET). LEAD WIRES: 18/20 GAUGE. MEETS SAE J1128 XLPE, TYPE SXL. A.C. VOLTAGE COILS: INTERNALLY FULL WAVE RECTIFIED TO SUPPLY THE COIL WINDING WITH D.C. CURRENT. THEREFORE THE COIL WINDING HAS NO INRUSH CURRENT MAKING IT SUITABLE FOR 50 OR 60 HERTZ (Hz) CYCLE APPLICATIONS. THE RECTIFIERS USED IN A.C. COILS MAY REQUIRE PROTECTION FROM TRANSIENT OVER VOLTAGES EXCEEDING 1000 VOLTS. PROTECT RECTFIED A.C. COILS BY INSTALLING A COMMERCIALLY AVAILABLE NONPOLARIZED SELENIUM DIODE SUPPRESSOR OR METAL-OXIDE VARISTOR ACROSS THE A.C. COIL AS SHOWN. 11.30.0 02/08