SAFETY INFORMATION & INSTRUCTION MANUAL

Similar documents
Intended Use: Explanation of Signal Word Consequences

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

PeroxiDraw Dispenser

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

DEMA Pro-Fill I Sink Dispenser

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

DEMA Pro-Fill II Sink Dispenser

SAM SPARTAN ACCURATE MEASURE DISPENSING SYSTEM INSTALLATION INSTRUCTIONS MODEL 681-3SAM 1. PARTS: A. SAM

Certo Chemical Dilution System

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

ALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

665 Series Dispenser. Metering tip kit

I Button Chemical Dispenser. Overview. Installation Instructions

Tools Needed for Mounting Cleá Filling Station

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

Spray & Foam Dispenser Item #

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

Spray Clean 606T-2 Installation Instruction

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS

Scale Feeder Manifold Water Filtration System Instruction Manual

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

BLACK SHADOW SERIES DISPENSER. Tools Needed for Mounting SCS Dispenser Hammer Drill with 1/4, 1/8, 9/32 and 5/32 Diameter Bits Pliers

Items # and #

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Dual Flow Manifold Systems Instruction Manual

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

Reference Manual FM-200 Series

Dual Port Manifold Water Filtration Systems Instruction Manual

Door Edge Protection Film 36 inch

Full Flow Drinking Water System Model: 3MFF100

FRS Dispenser (Foam-Rinse-Sanitize) Model # ol Systems. Dilution Control OPERATION SERVICE PARTS CARE

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

Dilution Control Systems. Multi-Task Dispenser Model #421700PL OPERATION SERVICE PARTS CARE. Dema #i GAPDB-MC2

3M Abrasive Systems Random Orbital Abrasive Disc Portfolio. Sanding & Finishing. Solutions. see inside. Distributed by:

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

Buffer 8125 Owner s Manual

HALLMARK INDUSTRIES INC

GM Specification Annual Test Data

PROMAX INSTRUCTION MANUAL

GM Specification Annual Test Data

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

(Airgap)

G E N E S I S R O C v AUTOMATIC REPLENISHMENT MODULE

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

3M TM Cubitron TM II Bonded Abrasive Grinding and Cut-Off Wheels. born to. grind. It s grinding reinvented. Featuring. cut & grind wheels

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED.

Shower System. Dual Head INSTRUCTION GUIDE

THANK YOU FOR CHOOSING BATHERBOX GETTING STARTED WHAT S IN THE BOX? N. Northview Ave Sioux Falls, SD 57107

3M-MaticTM. Tape Edge Fold Kit. Instructions and Parts List. For Use On: AccuGlide TM STD Upper and lower Taping Heads. Purpose of Attachment

ESE Series Cast Iron Sewage Pumps

Table of Contents. Introduction. KP1H Components... 2 Installation and Assembly

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

Installation Instructions / Warranty. Raindance Allrounder 28110XX1 Wall Outlet Adapter with Hose Connection 28108XX1

DEMA MODEL 582 FOAM STATION III INSTRUCTION SHEET

Agxcel GX12i Chemical Injection System

Installation Instructions / Warranty

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Document Library TS Data Sheet Universal Fuel System Cleaner. Data Sheet. Public

Value Super Filter Max Installation Manual

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

G8 Portable Fuel Transfer Pump Owner s Manual

Model 8346/8346CRP Shower & Eye/Face Wash

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Panel Bonding Adhesive

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Colt Series C400, C500

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

SOLUTION STATION Instruction Manual

Installation Instructions / Warranty

DEMA SQUIRT DRAIN UNIT

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

AGXCEL GX12i CHEMICAL INJECTOR 2% INJECTOR UNIT - PN# % INJECTOR UNIT - PN# E 6TH ST KEARNEY NE

Transcription:

SAFETY INFORMATION & INSTRUCTION MANUAL Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future reference. Intended Use: This Meguiar s Professional Metering System is intended to meter and mix automotive, water-based cleaning chemicals from concentrate. It is expected that all users be fully trained in the safe operation of this product, as well as with the use of the chemicals. Use in any other application or by other users has not been evaluated by Meguiar s and may lead to an unsafe condition. Explanation of Signal Word Consequences WARNING: CAUTION: Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage. Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury and/or property damage. CAUTION: To reduce the risks associated with product failure/bursting due to excessive water pressure, excessive water temperature, or other mechanical damage: Water supply must not exceed 125psi (8.6 Bar), and water temperature must not exceed 150 o F (66 o C). Do not use Teflon tape to seal internal plastic threads as the extra thickness of the tape may cause the plastic to crack. Use a non-welding liquid sealant instead, and DO NOT OVER-TIGHTEN. WARNING: To reduce the toxic, environmental, or fire risks associated with use of cleaning chemicals: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS. Always adhere strictly to the chemical manufacturer s health and safety information found on the product label and in their MSDS, and carefully follow all directions for use. CAUTION: To reduce the risks associated with hazardous water pressure: Always turn off water supply before servicing. CAUTION: To reduce the risks associated with hazardous water pressure: When servicing unit, be sure that replacement parts have been installed according to the drawing. 11/02/10 Page 1 of 8

1. PARTS CHECKLIST: ITEM DESCRIPTION QTY. A. Meguiar s Professional Metering System Assembly 1 B. ½ ID X 10 Long Vinyl Outlet Tubing (for 1 GPM Station Only) 1 C. ¼ Supply Tubing Weight - Ceramic 3 D. ½ ID X 6 Long Vinyl Outlet Tubing (For 4 GPM Station Only) 3 E. #10 Screw & Anchor Kit Set (Total: 2 Screws & 2 Anchors) 1 F. Label Sheet 2 G. Large Metering Tip Kit 1 H. Small Metering Tip Kit 1 I. Plastic Tee 1 J. ¼ ID X 22 Long Supply Tubing 1 K. ¼ Foot Valves 3 L. ½ ID X 6 Long Vinyl Supply Tubing and Foot Valve Assembly 1 M. 3/8 ID X 6 Long Vinyl Supply Tubing & Foot Valve Assembly 1 N. Small Gray Metering Tip 3 O. Small Green Metering Tip 2 P. Small Black Metering Tip 3 Q. Small Purple Metering Tip 3 R. 3/8 Supply Tubing Weight Ceramic 1 S. ½ Supply Tubing Weight PVC 1 2. INSTALLATION: Note: All installations must conform with local plumbing codes and use approved backflow preventers. Pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicating tee. WARNING: Water supply should not exceed 125 psi and water temperature must not exceed 150 F. A. Mounting and water supply: Remove the two cover retainer screws and the cover from the Meguiar s Professional Metering System assembly. Mount the unit(s) in position on the wall and locate the position for the mounting screws. Drill all of the holes into the drywall using a ¼ diameter bit for use with the included #10 screw and anchor set. (If mounting the Meguiar s Professional Metering System to wood and you do not plan to use the included anchors, drill 1/8 diameter holes.) Insert the anchors into drilled holes and hammer them into the wall until they are flush with face of wall. Assemble all of the #10 screws with a Phillips screwdriver into the anchors so the screw heads are sticking out of the wall approximately 1/8. Mount the Professional Metering System by inserting the screw heads through the keyhole slots in the base and tighten the screws. Replace the cover and screws. The water inlet is equipped with a female garden hose fitting (with strainer washer) for attaching a water supply hose. The fitting may be removed to permit direct connection to a 3/8" NPT pipe. The unit is designed so water can be supplied to either side by interchanging the pipe plug and female hose fitting. Note: Apply pipe dope, hand tighten, then turn 1-½ times with a wrench. Do not over tighten. WARNING: Do not use Teflon tape to seal internal plastic threads as the extra thickness of the tape may cause the plastic to crack. Use a non-welding liquid sealant instead. 11/02/10 Page 2 of 8

B. Chemical supply: WARNING: Wheel Brightener D140 should be placed on position number "one" exclusively to prevent cross mixing of chemistry. Such mixing could result in an explosive reaction. Place the chemical containers in a convenient location not more than 6 feet below the Meguiar s Professional Metering System (greater lifts will reduce injection capacities). Insert the vinyl supply tubing with the foot valve ends into the chemical containers. Cut the vinyl tubes to any convenient length that will allow them to extend from the bottom of the chemical container to the proportioner inlet barbs. (See Figure 1). Adhesive labels are provided for product labeling. C. Chemical injection adjustment: WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS. Eye and Skin Protection is recommended Chemical feed rates are controlled by metering tips screwed into the proportioner barbs. Select a tip for each barb using Table 1 or 2 as a guide. TIP RECOMMENDATIONS Note: All tip recommendations are based on a water pressure of 40 psi. Water pressure between 20psi and 80 psi will have little effect on ratio accuracy. Anything outside that parameter may require tip adjustment. Refer to Diagram on following page for educator location Product Part # Ratio Tip Color Barb/Pick-Up Size Eductor Location All Purpose Cleaner D101 4:1 Grey ¼ Barb 2 All Purpose Cleaner D101 10:1 Yellow ¼ Barb 2 All Purpose Cleaner D101 20:1 Green ¼ Barb 2 All Purpose Cleaner D101 4:1 White 3/8 Barb 1 All Purpose Cleaner D101 10:1 Black 3/8 Barb 1 All Purpose Cleaner D101 20:1 Green 3/8 Barb 1 All Purpose Cleaner Plus D103 4:1 Grey ¼ Barb 2 All Purpose Cleaner Plus D103 10:1 Black ¼ Barb 2 All Purpose Cleaner Plus D103 20:1 Green ¼ Barb 2 All Purpose Cleaner Plus D103 4:1 White 3/8 Barb 1 All Purpose Cleaner Plus D103 10:1 Black 3/8 Barb 1 All Purpose Cleaner Plus D103 20:1 Green 3/8 Barb 1 All Purpose Cleaner Plus D103 64:1 Pink ½ Barb 3 Pre-Clean All D105 4:1 Grey ¼ Barb 2 Pre-Clean All D105 10:1 Black ¼ Barb 2 Super Degreaser D108 4:1 Grey ¼ Barb 2 Super Degreaser D108 10:1 Black ¼ Barb 2 Super Degreaser D108 4:1 White 3/8 Barb 1 Super Degreaser D108 10:1 Black 3/8 Barb 1 Hyper Wash D110 400:1 Yellow ½ Barb 3 Shampoo Plus D111 128:1 Pink ½ Barb 3 Super Soap D112 128:1 Yellow ½ Barb 3 Glass Cleaner Concentrate D120 10:1 Black ¼ Barb 2 Glass Cleaner Concentrate D120 10:1 Turquoise 3/8 Barb 1 Wheel Brightener D140 2:1 No Tip 3/8 Barb 1 Wheel Brightener D140 3:1 White 3/8 Barb 1 Wheel Brightener D140 4:1 Brown 3/8 Barb 1 Last Touch Spray Detailer D155 1:1 No Tip 3/8 Barb 1 Last Touch Spray Detailer D155 1:1 No Tip ½ Barb 3 11/02/10 Page 3 of 8

CAUTION: When dispensing Hyper Dressing and Last Touch Spray Detailer using 4 gpm eductor, do not dispense into small secondary bottle. For use when filling large containers only. To dispense chemicals into a small secondary bottle (ie.16oz or 32oz) at a 4gpm flow rate may pose a splash hazard. TIP SIZING SMALL METER TIPS (USED ON SELECTOR) SMALL TAN ORANGE TURQUOISE PINK LIGHT BLUE BROWN RED WHITE GREEN BLUE YELLOW BLACK PURPLE GRAY LARGE LARGE METER TIPS (USED IN 3/8 EDUCTOR AND 1/2 EDUCTOR) SMALL CLEAR PURPLE YELLOW GREEN PINK TURQUOISE BLACK GRAY RED BLUE BROWN WHITE ORANGE LARGE 11/02/10 Page 4 of 8

3. OPERATION: The Meguiar s Professional Metering System is now ready for use. Depressing a push button opens the valve, allowing water to flow through the chemical proportioner that mixes chemical at the desired rate. The buttons are spring loaded to prevent accidental overflow if unattended, but may be converted to locking buttons by cutting off the tab at the notch. (See Figure 2). Pushing the button and tubing it 1/4 turn clockwise at the end of its travel allows the valve to lock on. This makes it unnecessary for the attendant to hold the button in while filling large containers. Turning the button in a counter-clockwise direction will release it, allowing the valve to shut off. WARNING: To reduce the toxic or environmental risks associated with use of cleaning chemicals: -If this modification has been made, the operator will need to pay close attention to ensure that over-flow does not occur. -Should over-flow occur, clean-up according to the instructions found in the chemical manufacturer s health and safety information found on the product label and in their MSDS 4. SERVICING: CAUTION: TURN OFF WATER SUPPLY BEFORE SERVICING. A. Proportioner fails to draw chemical: 1. Pinch outlet tube to create back pressure, which will cause unit to prime. The foot valve will keep the inlet tube primed thereafter. 2. Insufficient water supply pressure. 20 PSI is the minimum allowable. B. Proportioner stops drawing chemical: 1. Inspect foot valve for dried chemical or dirt. Soak in hot water to clean. 2. Proportioner metering tip clogged with dried chemical. Remove tip and try injecting in hot water. If there is no suction, remove proportioner and soak in hot water to clear interior passages. 3. Inspect proportioner to ensure that there are no mineral deposit build-ups on the nozzle. If so, soak proportioner body in deliming solution. (Remove all parts attached to proportioner before soaking in deliming solution.) Note: Use care when handling hazardous chemicals. C. Proportioner continues to draw chemical after water valve closes: Chemical supply is higher than bottom of discharge tube creating a natural siphon. Lower the supply vessel or hang up outlet tube after use. D. Valve Malfunction: Check that the button moves freely in & out and that a "click" can be heard when the button is pushed and released, indicating that the magnet is activating the plunger properly. Remove cover. To inspect internal parts, unscrew magnet housing and carefully pull off the enclosing tube so as not to drop the plunger, kick-off spring, and spacer. Check for dirt or damage impeding plunger and kick-off spring movement. Inspect the diaphragm, making sure the two small pin holes (bleed hole) in the diaphragm convolution are clear to allow the valve to close. CAUTION: When servicing unit, be sure that replacement parts have been installed according to the drawing. 11/02/10 Page 5 of 8

16 15 15 13 14 12 17 17 17 18 21 19 20 45 36 28 36 30 31 29 27 27 24 25 26 22 22 23 4-PLACES QTY. PART NO. DESCRIPTION 1 66-139 Magnet Housing (Specify color) 2 66-140 Push Button (Specify Color) 3 63-35 Magnet 4 63-36 Spring 5 41-7-25 Enclosing Tube 6 63-87 Valve Repair Kit 7 63-37 Spacer 8 41-1-8 Kick-off Spring 9 63-38 Plunger 10 41-15-10 Diaphragm 11 63-39 Valve Body 12 100-38 Strainer Washer 13 65-10-2 Hose Coupling 14 65-14-2 Hose Fitting Stem 15 66-31 Close Nipple 16 66-153 Pipe Plug & O-Ring Assembly 17 16-30 Action Gap Assembly 18 61-99-1 1GPM Proportioner Assembly 19 61-66-4 1GPM Proportioner Assembly 20 61-101 4GPM Proportioner Assembly 21 63-96-4EP Selector Assembly 22 100-16E- Foot Valve 23 61-104 Foot Valve 24* 61-107 Ceramic Weight (For 3/8 Tube) QTY. PART NO. DESCRIPTION 25 61-107-2 Ceramic Weight (For 1/4 Tube) 26 65-25 PVC Weight (For 1/2 Tube) 27 85-15-27 1/2 ID x 10 Lg. Vinyl Tubing 28 61-21 1/2 ID x 6 Lg. Vinyl Tubing 29 ----- 3/8 ID x 6 Lg. Vinyl Tubing 30 100-250-3 1/4 ID x 6 Lg. Vinyl Tubing 31 ----- 1/2 ID x 6 Lg. Vinyl Tubing 32 150-6 Rubber Washer 33 61-36 Flow Disc 34 63-78 O-Ring 35 63-80 Inlet Barb (3/8 Barb) 36 61-9K Metering Tip Kit-13 Sizes (For 3/8 Barb) 37 63-80-1 Elbow 38 61-103 Elbow Insert 39 619-13 O-Ring 40 150-6-11 Rubber Washer 41 87-3-1 Nozzle 42 87-5-1 Diaphragm 43 87-6-1 Retainer 44 87-4-1 Spring 45 100-15K Metering Tip Kit-14 Sizes (For ¼ Barb) *Foot Valve also available with Silicone (100-16S-) or Viton (100-16V-) rubber seals. Please specify material when ordering. 11/02/10 Page 6 of 8

11 1 2 3 4 5 7 8 9 10 6 40 41 42 39 See Section "A-A" Large end of tapered spring 43 44 SECTION "A-A" 17 21 SELECTOR ACTION GAP 32 32 32 33 33 37 35 18 19 20 34 38 1 GPM PROPORTIONER 1 GPM PROPORTIONER 4 GPM PROPORTIONER 11/02/10 Page 7 of 8

Product Use: All statements, technical information and recommendations contained in this document are based up on tests or experience that Meguiar s believes are reliable. However, many factors beyond Meguiar s control can affect the use and performance of a Meguiar s product in a particular application, including the conditions under which the Meguiar s product is used and the time and environmental conditions in which the product is expected to perform. Since these factors are uniquely within the user s knowledge and control, it is essential that the user evaluate the Meguiar s product to determine whether it is fit for a particular purpose and suitable for the user s method of application. Warranty and Limited Remedy: Meguiar s warrants this tool against defects in workmanship and materials under normal operating conditions for one year from the date of purchase. This limited warranty does not apply to any products which have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage supply, physical abuse, or misapplication. Rubber and synthetic rubber parts such as o - rings, diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of Meguiar s products. If products are altered or repaired without prior approval of Meguiar s Inc., this warranty will be void. MEGUIAR S MAKES NO OTHERWARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE. User is responsible for determining whether the Meguiar s tool is fit for a particular purpose and suitable for user s application. User must operate the tool in accordance with all applicable operating instructions, safety precautions, and other procedures stated in the operating manual to be entitled to warranty coverage. Meguiar s shall have no obligation to repair or replace any tool or part that fails due to normal wear, inadequate or improper maintenance, inadequate cleaning, improper operating environment, improper utilities, operator error or misuse, alteration or modification, mishandling, lack of reasonable care, or due to any accidental cause. If a tool or any part thereof is defective within this warranty period, your exclusive remedy and Meguiar s sole obligation will be, at Meguiar s option, to repair or replace the tool or refund the purchase price. Limitation of Liability: Except where prohibited by law, Meguiar s and seller will not be liable for any loss or damage arising from the Meguiar s product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. 11/02/10 Page 8 of 8