HYDRO ION Water softener Type: VAD CS

Similar documents
Introduction Advantages of cooperating with Our service - our conditions Our standard central control valve

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

Fleck Epoxy Lined Section 2 Steel Softeners

Aqualine Active Carbon Filters with surface piping

INDUSTRIAL WATER SOFTENERS: GUIDE TO THE CHOICE

Everpure Claris filter cartridge family

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS

DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS

Technical Manual. Models: Standard Softeners High Efficiency Softeners Combination Softeners S150 S250 S250 OD S350 S550 S650 S650 OD Q850 Q850 OD

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

TNT SERIES WATER CONDITIONERS

PRESSURE GAGES AND TEST TAPS

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

Fleck Top Mount Section 1 Fiberglass Softeners

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing

255 Valve Specifications

Solenoid Valve DF-SA-series

Fleck Fiberglass Section 9 Chloride Dealkalizers

Hydrosafe - Model HSFS

COMMERCIAL / INDUSTRIAL WATER SOFTENERS

Solenoid Valve ST-IA-series

Installation & Technical Guide. Domestic & Commercial.

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

Solenoid Valve ST-SA-series

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI

Solenoid Valve DF-SB-series

Filtration and separation technology. Lenzing OptiFil Automatic backwash filter

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

Salt Spray Chamber HKT 1000

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

Flow-compensated temperature controller AVTQ DN 15

H-125 HE SERIES. Owner s Manual HIGH EFFICIENCY SYSTEM. Manufactured by: HELLENBRAND, INC. Web:

NEW CHAPTER 1 CABINET SOFTENERS ARE YOU LOOKING FOR YOUR PERSONAL SOFTENER? 1. CABINET - PERSONALISED

ASTM Methods that are feasible with Metrohm instruments

Installation and Operation Manual

Combination angle valve with filter and angle valve with filter. By SCHELL.

T6-PLAN HYGIENE CENTRALLY CONNECTED RADIATOR.

CHAPTER 1 CABINET SOFTENERS 1. CABINET - PERSONALISED ARE YOU LOOKING FOR A PERSONAL SOFTENER?

HD 1050 De Cage. Heavy-duty cold water high-pressure cleaner with 10hp Yanmar diesel engine and robust steel cage. Compact cage frame

General Catalog. A New Vision for Quality Pumps. General Catalog

Butterfly valves PN6, PN10, PN16

Volute Casing Pumps LSN. according to iso 2828 / iso Jansen Pompentechniek T: +31(0) E:

Owner s Manual. H151 HE - High Efficiency Water Softening System

CATALOG OF REPLACEMENT PARTS

something new in the air Technical Bulletin

HAWLE-AIR RELEASE VALVES

Owner s Manual AMERICAN AQUA Saline, MI (734) Howell, MI (517) Adrian, MI (517)

TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL

Data sheet: Wilo-Stratos-Z 25/1-8

Process Inline Filter Protective filter PLF2-9HF

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

INDUSTRIAL GENERATORS. steam or overheated water 97/23/CE - P.E.D. certified

Signature Series. Duplex Softener Service Manual

or OWNER S MANUAL MODEL R

APP S 674 pumps APP S / APP S APP S

HD 1050 DE. Maximum performance. Optimum ease of use. Maximum independence. Outstanding mobility

Specifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

Flow switches for insertion installation

Reverse Osmosis (RO) Water Treatment Systems

Assembled Engineered Systems. Softeners Filters Specialty Systems

The JET Filter. Scope of Delivery. patented. The New Definition of Purity for Your Medium. Our Filter Systems Protect

65 Series. Valve Operation Manual

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption.

SELF-CLEANING FILTER

WATER TREATMENT COMPONENTS. Residential R.O. components

Performa Valve Specifications. 263 and 268 Configurations. imagination at work

GRAF EcoBloc Stormwater Management System

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

MIB 303 AC Separation System, Module. System Reference. Product No Aug V1. Printed Book No. Alfa Laval Marine & Power

High performance door Albany RR300. ASSA ABLOY Entrance Systems

BNT 85 /185 Valve Operation Manual

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

Safety drying ovens with expanded temperature range

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

LINEAR AND ROTATING TYPE AUTOMATIC SELF-CLEANING LIQUID FILTERS

GENO -MX 1" - MX DN 100 backwash filter. Intended use. Scope of supply. Function. Structure

Water Specialist CI Control Valve Programming and Cover Drawing Manual

ELADOS EMP-KKS Diaphragm Piston Pump Type

Safety drying oven with expended temperature range

SOLAR THERMAL EQUIPMENT

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

ALUMINIUM COMPRESSED AIR FILTERS

BLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09

herborner.x -C Technical data brochure 50 Hz

Accessories STRA Room Controller

Process screen basket filter PRFS

INDUSTRIAL WATER PROCESSING SYSTEMS CENTRAL BRINE DRUM INSTALLATION INSTRUCTIONS

Metals Eliminator System User Manual

TECHNICAL INFORMATION BIOMASS SOLUTIONS FOR A MORE ECOLOGICAL AND ECONOMICAL WORLD

CLASSEQ LTD. Spares manual P500 AS WS

APP pump instruction APP 21-43

ProMinent Hydro Hydraulic Diaphragm Metering Pumps

Transcription:

HYDRO ION Water softener Type: VAD CS Application HYDRO ION water softener used to soften / partly soften cold drinking and process water. Duplex design to ensure a constant supply of soft water. Regeneration is possible either with full or reduced salt volume. HYDRO ION water softener suited to soften / partly soften water coming from boreholes, process plants, cooling plants, boiler-feed and air-conditioning systems. Function Our HYDRO ION water softener operates according to the ion exchange process. Our HYDRO ION Duplex water softener VAD - CS is suited for installation sites with a demand of constantly softened water. Sturdy and service-friendly central control valve actuated via a menu-controlled micro processor control in wall mount casing with the below operation modes: Volume control Forced regeneration Water-Refresh Automatic disinfection Residual capacity, flow and failure detection are shown in the display. Service signal and failure record contact are forwarded to BMS. A fully automatic regeneration is released by the micro processor control once the set soft water quality is achieved. Description / Scope of supply HYDRO ION water softener consisting of: 2 x pressure vessels 2 x ion exchange resin with quartz gravel as support layer 2 x central control valves 1 from noryle 1,5 and 2 from brass with epoxy resin coating 1 x micro processor control in wall casing 1 x PE brine tank incl. sieve base 1 x brine safety valve 1 x turbine water meter 1 x internal PVC pipe connection 1 x disinfection system (chlorinator) for softeners with salt saving mode 1 x brine alarm 1 x O&M 1 x measuring kit hardness control Accessories Assembly mount DN 25 (incl. blending) - art.-no. 511.000 Assembly mount DN 25 (excl. blending) - art.-no. 510.016 Assembly mount DN 40 (incl. blending) - art.-no. 511.102 Assembly mount DN 40 (excl. blending) - art.-no. 511.100 Flexible hoses 1 - art.-no. 001.034 Flexible hoses 1 ½ - art.-no. 001.038 External blending DN 32 - art.-no.530.035 External blending DN 50 - art.-no. 530.036 1/6

Note / Installation conditions Technical Data and general technical regulations as well as the local installation regulations shall be kept. The regulations as per DIN 1988 part 4 require a safety stop against backflow (system separation). A fine filter shall be installed before the softener to avoid particles dragged along from the pipe to penetrate the system. The ambient temperature shall not exceed 40 C. Any radiation heat shall not exceed a temperature of 40 C as well. Installation site shall be frost-free. The installation site shall be free from solvent, colour, lacquer and chemical vapour. Connection for the micro processor control shall be provided adjacent to the softener ( (230 V / 50 Hz). A channel drain shall be provided (min. DN50) to discharge the wash water. Any lifting appliance shall be resistant to seawater. 2/6

Technical Data Full salt rate [A] Technical data Systems with full salting (Type A) 25 - CS 1 - A 50 - CS 1 - A 75-CS 1 - A HYDROION VAD CS A 125-CS 1,5 -A 150-CS 1,5 -A 200-CS 1,5 -A 250-CS 2- A 375-CS 2- A 600-CS 2- A Connection mains / soft water line DN 25 (1") DN 40 (1 1/2") DN 50 (2") DN 80 Drain line (min.) DN 50 DN 50 DN 70 Mains electrical connection 230 V / 50 Hz AC 230 V / 50 Hz AC 230 V / 50 Hz AC Electrical connection (secondary) 12 V AC 12 V AC 12 V AC Water temperature (min./max.) 5 C / 30 C 5 C / 30 C 5 C / 30 C Ambient temperature (min./max.) 5 C / 40 C 5 C / 40 C 5 C / 40 C Operational pressure (min./max.) 2) 2 bar / 8 bar 2 bar / 8 bar 2 bar / 8 bar Performance data Flow rate < 0,1 dh 1) m³/h 2,5 3,5 4,5 6,5 8,0 10,5 13,5 17,0 24,0 Flow rate at blending (356 ppm to 151 ppm) m³/h 4,3 6,1 7,8 11,3 13,9 18,3 23,5 29,6 41,7 Pressure loss at rated flow 1) bar 0,49 0,79 1,09 0,88 0,8 1,39 1,18 1,55 2,18 Capacity at 300 ppm CaCo 3 1) m³ 5,3 10,8 16,2 27,3 32,2 43,5 54,9 82,8 132,3 Salt consumption kg 5 10 15 25 30 40 50 75 120 Waste water volume per regeneration m³ 0,17 0,36 0,55 0,88 1,06 1,40 1,73 2,62 4,20 Volume and weights Resin vessel volume Ltr. 38,4 79,5 115 153 277 277 344 473 704 Resin volume Ltr. 2 x 25 2 x 50 2 x 75 2 x 125 2 x 150 2 x 200 2x250 2x375 2x600 Support gravel volume kg 2 x 4 2 x 7 2 x 10 2 x 17 2 x 40 2 x 40 2 x 40 2 x 58 2 x 40 Brine tank volume Ltr. 140 190 340 460 460 670 920 1000 1500 Regeneration salt supply kg 50 75 125 175 162 250 325 375 525 Operational weight (complete unit) max.. kg 200 350 520 750 1100 1220 1500 2020 3000 Dimensions Height (max.) ± 30 mm H mm 1300 1600 1750 1600 1700 1700 2000 2200 2220 Ceiling height (min.) mm 1800 1800 1900 1900 2000 2000 2200 2400 2500 Width (min.) with 1. brine tank B mm 1400 1430 1570 2165 2450 2560 2800 2835 3500 Width (max.) with 2. brine tank B mm 2050 2090 2450 3075 3330 3630 4020 4200 4910 Depth (max.) T mm 600 600 750 850 850 1000 1150 1050 1450 Depth (mind.) without brine tank T mm 430 430 450 600 750 750 750 880 1050 Clearance tank/tank A1 mm 460 460 460 720 855 855 855 930 1080 Clearance brine tank/tank A2 mm 510 530 630 760 820 900 1020 1070 1340 Diameter pressure tank D1 mm 258 310 363 413 555 555 555 635 779 Diameter brine tank 460 / 460 / 594 / 703 / 703 / 847 / 997 / 1015/ 1050/ D2 mm (min. / max.) 565 565 723 833 833 973 1123 1120 1150 897 1232 1344 1341 1434 1434 1721 1918 1892 Height pressure tank H1 mm ± 6 ± 6 ± 6 ± 15 ± 15 ± 15 ± 15 ± 15 ± 15 Height top control valve H2 mm 1080 1420 1530 1570 1665 1665 1930 2130 2160 Heigt brine tank H3 mm 843 1123 1200 1196 1196 1196 1206 1340 1500 Heigt feed (mains water) / discharge (soft water) H4 mm 960 1295 1400 1430 1520 1520 1810 2010 2040 Height VAD (incl. Alternator) H5 mm 1080 1600 1700 1570 1660 1660 1970 2170 2200 Control box (B x H x T) mm 240 x 170 x 110 Mounting board (B x H x T) mm 330 x 200 x 10 1) Values dependent on operation mode and mains water quality 2) The flow pressure is relevant for min. operating pressure and the stagnation pressure for max. operating pressure 3/6

Technical Data Salt saving mode [B] Technical data Systems with economic salting (Type B) 25-CS 1 - B 50-CS 1 - B 75-CS 1 - B HYDROION VAD CS B 125-CS 1,5 - B 150-CS 1,5 - B 200-CS 1,5 - B 250-CS 2 - B 375-CS 2 - B 600-CS 2 - B Connection mains / soft water line DN 25 (1") DN 40 (1 1/2") DN 50 (2") DN 80 Drain line (min.) DN 50 DN 50 DN 70 Mains electrical connection 230 V / 50 Hz AC 230 V / 50 Hz AC 230 V / 50 Hz AC Electrical connection (secondary) 12 V AC 12 V AC 12 V AC Water temperature (min./max.) 5 C / 30 C 5 C / 30 C 5 C / 30 C Ambient temperature (min./max.) 5 C / 40 C 5 C / 40 C 5 C / 40 C Operational pressure (min./max.) 2) 2 bar / 8 bar 2 bar / 8 bar 2 bar / 8 bar Performance data Flow rate < 0,5 dh 1) m³/h 2,5 3,5 4,5 6,5 8,0 10,5 13,5 17,0 24,0 Flow rate at blending (356 ppm to 151 ppm) m³/h 4,3 6,1 7,8 11,3 13,9 18,3 23,5 29,6 41,7 Pressure loss at rated flow 1) bar 0,49 0,79 1,09 0,88 0,8 1,39 1,18 1,55 2,18 Capacity at 300 ppm CaCo 3 1) m³ 3,9 7,8 11,8 19,9 23,4 31,6 39,9 60,2 96,2 Salt consumption kg 2 4 6 10 12 16 20 30 48 Waste water volume per regeneration m³ 0,15 0,31 0,46 0,76 0,92 1,22 1,52 2,28 3,66 Volume and weights Resin vessel volume Ltr. 38,4 79,5 115 153 277 277 344 473 704 Resin volume Ltr. 2 x 25 2 x 50 2 x 75 2 x 125 2 x 150 2 x 200 2 x 250 2 x 375 2 x 600 Support gravel volume kg 2 x 4 2 x 7 2 x 10 2 x 17 2 x 40 2 x 40 2 x 40 2 x 58 2 x 40 Brine tank volume Ltr. 140 190 190 340 340 460 460 670 920 Regeneration salt supply kg 50 75 75 125 125 175 175 250 337 Operational weight (complete unit) max. kg 200 350 460 690 1050 1150 1350 1900 2900 Dimensions Height (max.) ± 30 mm H mm 1300 1600 1750 1600 1700 1700 2000 2200 2220 Ceiling height (mind.) mm 1800 1800 1900 1900 2000 2000 2200 2400 2500 Width (min.) with 1. brine tank B mm 1400 1430 1430 2100 2300 2400 2500 2770 3200 Width (max.) with 2. brine tank B mm 2050 2090 2150 2845 3120 3350 3430 3865 4465 Depth (max.) T mm 600 600 600 750 750 850 850 1000 1150 Depth (min.) without brine tank T mm 430 430 450 600 745 750 750 880 1050 Clearance tank/tank A1 mm 460 460 460 720 855 855 855 930 1080 Clearance brine tank/tank A2 mm 510 530 560 700 770 830 870 980 1130 Diameter pressure tank D1 mm 258 310 363 413 555 555 555 635 779 Diameter brine tank 460 / 460 / 460 / 594 / 594 / 703 / 703 / 847 / 997 / D2 mm (min. / max.) 565 565 565 723 723 833 833 973 1123 897 1232 1344 1341 1434 1434 1721 1918 1892 Height pressure tank H1 mm ± 6 ± 6 ± 6 ± 15 ± 15 ± 15 ± 15 ± 15 ± 15 Height top control valve H2 mm 1080 1420 1530 1570 1665 1665 1930 2130 2160 Heigt brine tank H3 mm 843 1123 1123 1200 1200 1196 1196 1196 1206 Heigt feed (mains water) / discharge (soft water) H4 mm 960 1295 1400 1430 1520 1520 1810 2010 2040 Height VAD (incl. Alternator) H5 mm 1260 1600 1700 1570 1660 1660 1970 2170 2200 Control box (B x H x T) mm 240 x 170 x 110 Mounting board (B x H x T) mm 330 x 200 x 10 1) Values dependent on operation mode and mains water quality 2) The flow pressure is relevant for min. operating pressure and the stagnation pressure for max. operating pressure 4/6

Pressuare loss (bar) 3,50 Pressuare loss HYDROION VAD - CS 3,00 2,50 2,00 1,50 1,00 0,50 0,00 0 5 10 15 20 25 30 35 Flow rate (m³/h) 5/6

6/6