CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

Similar documents
CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

FLOW RATE STATIC BALANCING Valves for radiators

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM

Connection and regulation kit for HVAC terminal units

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

CALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

THERMOSETTER Recirculation thermal balancing valve

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

WAY MOTORISED COMPACT ZONE VALVES

Pre-assembled distribution manifolds for radiant panel systems

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

Pressure Independent Control Valve

548 hydraulic separator

MOTORISED BALL VALVE. Uni/Bi-directional. patented. 3 points 2 points Price list root SR... SS... SY... Connection with ball valve.

80% Max working pressure: Max working temperature: 70 C. Flow-meter regulation range: Flow meter-regulation range: ± 10%

Art.918C Pre-assembled manifold with flow meters, air

Preassembled manifolds with flow meter, series CPRFL

CALEFFI. Differential pressure by-pass valve. 519 series 01007/14 NA. Replaces 01007/12 NA

PRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue

CT3202.0_01 EN February 2018

LK Manifold Shunt VS2

LK 820 ThermoVar. Technical Data. Thermic Valves and Check Valves. Opening temperatures 45 C, 55 C, 61 C, 66 C, 72 C or 80 C.

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Components for central heating

real quality made in italy circulation pumps

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG

MANIFOLDS AND DISTRIBUTION EQUIPMENT

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

CALEFFI. QuickSetter Balancing Valve with flow meter. Installation Tip

LK Manifold Shunt VS 2-2,5

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

TECHNICAL CATALOGUE EUROPA CHECK AND FOOT VALVES

Pressure independent balancing and control valve AB-QM DN

TECHNICAL CATALOGUE BLOCK CHECK AND FOOT VALVES

2-Port and 3-Port Zone Valves & Actuators, PN16

Pressure independent balancing and control valve

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

Pump Stations for Heating Circuits

Products for underfloor heating

Pressure independent balancing and control valve For ON/OFF control

Thermostatically controllable valves art. VD/VS/VCR/VCD/VCS xxxx

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

2-Port and 3-Port Zone Valves, PN16

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

HERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups...

FCU Floor Control Unit

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Installation and Operation Instructions HeatBloC K31 - DN 25

Fan-coil valves Series

Safety cap. Measuring probe. Seal. Operating principle. Advantages of balanced circuits. Balanced circuits have the following principal benefits:

T2 Wall Hung Radiator & UFH Manifolds

Automatic balancing valves ASV-PV DN (3rd gen.)

VP1000. Pressure Independent Control Valve. Product Bulletin

TECHNICAL CATALOGUE WASHING MACHINE VALVES

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

VERTICAL MULTISTAGE PUMP SETS

TECHNICAL CATALOGUE BALL VALVES: PARIS

Product range Solex Technical data and dimensioning. 5 Years

Zone Valves and Parts (Honeywell)

Pump group DN 25 SA, SMTC, SMT. Mounting and operating instruction

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 09/ ENG

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

VE-S_15-32 Pressure Independent Balancing & Control Valves

TECHNICAL CATALOGUE BALL VALVES: IDEAL

Installation and Commissioning Instructions High Temperature Zone Module F31-1" (DN 25)

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Pressure independent combined control and balancing valves with independent EQM characteristics

K35 HeatBloC with 3-temperature mixing valve

Grundfos Home Booster

TECHNICAL CATALOGUE GAS BALL VALVES: BERLIN

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range

ZONE CONTROLE / 2-WAY

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

Transcription:

Direct supply unit for heating systems 65 series ACCREDITED ISO 9 FM 65 CALEFFI 7/7 GB replaces dp 7/5 GB Function The direct supply unit performs the function of supplying the heating system circuits at high temperature. Complete with high-efficiency pump, flow and return temperature gauges on secondary circuit, secondary circuit shut-off valves, preformed shell insulation. The unit is reversible: in fact, the flow direction can be inverted from right to left, depending on installation requirements. This unit can be coupled to the 559 series SEPCOLL separator/distribution manifold with 5 mm centre distance connections. The differential by-pass valve (code 596) and mounting bracket (code65) are optional. Product range Code 656AL Direct supply unit. With UPM Auto L 5-7 pump. Centre distance 5 mm size DN 5 ( ) Code 656UPM Direct supply unit. With UPML 5-95 pump. Centre distance 5 mm size DN 5 ( ) Technical specifications Materials Connection pipes Material: steel Fe 6 Check valve Body: Obturator: Shut-off valves Body: brass EN 6 CW6N PPAG brass EN 65 CW67N Performance Medium: water, glycol solutions Max. percentage of glycol: % Maximum working pressure: kpa ( bar) Minimum working pressure: 8 kpa (,8 bar) Maximum working temperature: C Connections: - system side: F (ISO 8-) - boiler side: / M (ISO 8-) - connection centre distance: 5 mm Insulation Material: EPP Average thickness: mm Density: 5 kg/m Working temperature range: -5 C Thermal conductivity:,7 W/(m K) at C Reaction to fire (UL9): class HBF Pump -efficiency pump: models: UPM Auto L 5-7 UPML 5-95 Body: cast iron GG 5/ Electric supply: V - 5/6 Hz Max. ambient humidity: 95% Max. ambient temperature: UPM Auto L 5-7: 7 C UPML 5-95: 55 C Protection class: UPM Auto L 5-7: IP UPML 5-95: IPXD Pump centre distance: mm Pump connections: / (ISO 8-) with nut Temperature gauges Double scale: 8 C ( 76 F) Safety Thermostat kit code 65 (optional) Setting temperature: 55 C Protection class: IP 65 Contact rating: A/ V Differential by-pass code 596 (optional) Body: brass EN 98 CB75S Obturator: EPDM Spring: stainless steel EN 7- (AISI ) Seals: EPDM Maximum working pressure: bar Max. working temperature: C By-pass setting range: kpa (, m w.g.) Connections: M x M (ISO 8-) Mounting bracket code 65 (optional) Material: stainless steel

Head available at the unit connections Test performed with constant speed control Dimensions H (m w.g.) (kpa) 7 7 UPM Auto L 5-7 6 5 6 5 F A E C A F H,5,5,5 G (m /h) D Test performed with constant pressure control H (m w.g.) (kpa) UPML 5-95 9 8 8 8 7 7 6 6 B B G 5 5 Code 656AL 656UPM A B / / C 5 5 D 6 6 E 5 5 F 6,5 6,5 G 55 55 H 8 8 Mass (kg) 6,5 8,,5,5,5,5 G (m /h) Note: The pumps can operate with constant speed control (UPM only), constant or proportional pressure control, which adapts the performance to system requirements. For further details, see the installation instruction sheet of the pump supplied in the package. 5 SYSTEM RETURN SYSTEM FLOW 5 Hydraulic diagram SR SF 7 8 6 BOILER RETURN Characteristic components BOILER FLOW -efficiency pump UPM Auto L 5-7 or UPML 5-95 Differential by-pass valve (optional)* Flow temperature gauge Return temperature gauge 5 Shut-off valves on secondary circuit 6 Connection pipe (with check valve) 7 Operating spanner for shut-off valves on secondary circuit 8 Insulation 9 Structural element (spacer) * The factory setup includes installation of a blind spacer (closed) 9 BR Shut-off valve Temperature gauge Differential by-pass valve BF System pump Check valve

Installation Code 656AL Modified flow direction Code 656AL Code 656AL Code 656AL Modified flow direction Note: The direct supply unit is reversible, meaning the flow direction can be changed. Hydraulic separators-manifolds Accessories 559 SEPCOLL + tech. broch. 8 Centre distance: 5 mm. Main connections / F. Outlet connections / with captive nut: two at the top and two at the bottom. Working temperature range: C. 559 SEPCOLL + tech. broch. 8 Centre distance: 5 mm. Main connections / F. Outlet connections / with captive nut: three at the top and one at the bottom (or viceversa). Working temperature range: C. 559 SEPCOLL + tech. broch. 8 Centre distance: 5 mm. Main connections F. Outlet connections: two at the top, / with captive nut and one at the side, F. Working temperature range: C. 559 SEPCOLL tech. broch. 8 Centre distance: 5 mm. Main connections F. Outlet connections: two at the top, / with captive nut. Working temperature range: C. Installation example The union with captive nut allows installation of the 65 series unit on any M pipe. 559 Pair of plugs with gaskets for unused outlets. For 559 and 55 series. 559 Pair of fittings with gaskets. For 559 and 55 series. 656 Pair of eccentric tailpieces. Centre distance: 5 5 mm. Connections: / F with captive nut x F. 65 Sensor holder extension. Connections M x F. Side connections M F x M F x /8 F x / F 65 Safety thermostat kit for heating. Setting temperature 55 C ±. Protection class: IP 65. M threading. 65 Female union with captive nut, complete with gasket. Connections: / F with captive nut x F. /

Mounting bracket 65 Mounting bracket. In stainless steel. Hydraulic characteristics p (kpa) p (m w.g.) Setting positions Bracket installation The mounting bracket for wall installation must be secured using wall anchors, using the corresponding holes on the base. Flow rate (l/h) The unit should be applied to the bracket, using the corresponding seats under the hexagonal part of the shut-off valves. The hydraulic characteristics are calculated while taking account of the ball shut-off valves fitted. Installation of the differential by-pass valve To fit the differential by-pass, it should be applied in place of the by-pass spacer template. After shutting off the ball valves using the specific supplied spanner, unscrew the captive nuts as illustrated in the following figures. Differential by-pass 596 Differential by-pass for 65, 66 and 67 series units. Max. working pressure: bar. Max. working temperature: C. Setting range: kpa (, m w.g.). Connections M x M. Installation differs depending on the supply direction in the flow circuit: - by-pass installation in the version with RH side supply and bottom-up flow (equivalent to LH side supply and top-down flow); The differential by-pass valve is used to control the head to which the secondary distribution circuit is subjected. When the differential pressure setting value is reached, the obturator opens and allows the medium to pass from the flow to the return line of the circuit, limiting the differential pressure at the set value. This action is particularly useful when single circuits are shut off by automatic two-way ON/OFF, modulating or thermostatic valves. - by-pass installation in the version with LH side supply and bottom-up flow (equivalent to RH side supply and top-down flow).

Right hand-left hand reversibility The unit is assembled in the factory with RH side supply and bottom-up flow (equivalent to LH side supply and top-down flow). If necessary, the flow direction can be exchanged. For this reason, the nuts on the unit are not fully tightened in the factory, making it easier to carry out this procedure if required. We recommend always checking that the nuts have been fully tightened during installation. To make the exchange, proceed as follows:. Remove the insulation; the front and rear shells are easy to remove as they are slightly restrained to one another. In versions with UPML 5-95 pump, it is necessary to rotate the electronic part of the pump, unscrewing the four screws, as indicated by the arrows, and turning the body anticlockwise by 9. If this step is not performed, it will not be possible to fit the unit back inside the insulation. In AL versions with UPM Auto L pump no changes are required for the circulation pumps.. Reassemble the unit as indicated in the figure, fully tightening the captive nuts and taking care to position the seals in the correct way. 5. Invert the flow and return temperature gauges.. Unscrew the captive nuts fully using a spanner of the correct size and remove the pump. 6. Move the square spacer and fit it on the right-hand side. Note: The central notch in the insulation can be used to house the circulation pump and safety thermostat electrical wiring cables.. Position the connecting pipe on the right-hand side, rotating it on its axis by 8. 7. Reassemble the insulation.

CAMERA 5 5 CAMERA 5 5 PRANZO 5 5 PRANZO ENTRATA 5 5 ENTRATA CUCINA C. MATRIM. BAGNO 5 5 CUCINA 5 5 BAGNO Application diagrams C. MATRIM. Pump Thermostatic valve Electric wiring box Lockshield valve Shut-off valve Clock SPECIFICATION SUMMARY 65 series Direct supply unit for heating systems, can be coupled to SEPCOLL 559 series. Configuration with bottom-up flow and RH side supply, or viceversa. Connections to primary circuit / M (ISO 8-). Connections to secondary circuit F (ISO 8-). Connection centre distance 5 mm. Maximum working temperature C. Maximum working pressure kpa ( bar). Minimum working pressure 8 kpa (,8 bar). Complete with high-efficiency pump UPM Auto L 5-7 (UPML 5-95). Protection class IP (UPML 5-95 IPXD). Temperature gauge scale 8 C ( 76 F). Secondary circuit shut-off valves. Connection pipe in Fe 6 steel. Check valve with brass body, obturator in PPAG. With pre-formed shell insulation in EPP. Code 596 Differential by-pass valve. Brass body. Connections M x M. Stainless steel spring. Setting range from, to m w.g. ( kpa). Maximum working pressure bar. Maximum working temperature C. Code 65 Stainless steel mounting bracket. Code 65 Female union with captive nut, complete with seal. Connections / F with captive nut x F (ISO 8-). Code 656 Pair of eccentric tailpieces. Connections / F with captive nut x F (ISO 8-). Centre distance 5 5 mm. We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. 9 n. 5 8 Fontaneto d Agogna (NO) Italy Tel. +9 89 Fax +9 867 info@caleffi.com www.caleffi.com Copyright 7 Caleffi