Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP)

Similar documents
Direct Gas-Fired Heating

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

WAC Air Curtains Technical Guide

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators


Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

INDIRECT FIRED FURNACE PARTS

2520- EC Motor Speed Controller

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

SECTION AIR TERMINAL UNITS

FAN POWERED TERMINAL UNITS

Direct Gas-Fired Make-up Air Heaters

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Warm. SDR Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Outdoor or Indoor Mounted Units To 16,000 CFM And 1.

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

ELECTRONIC FIREPLACE DAMPER

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

Warm. SDFI Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Indoor Mounted Units To 64,000 CFM And 9M BTUH

ICEMINI & Vertical MTI Units

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Air Handling Unit Fan Selection Guide

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Inline Fans [ 14 ] * UL is optional and must be specified.

CH5000 Heat Recovery Ventilator

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

MSK-1B 1 SERVING 31 - HVAC ADDITION DALTON HIGH SCOOOL RENOVATION REL

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

Installation, Operation and Maintenance Manual

FAN POWERED TERMINAL UNITS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Filtered Kitchen Supply Packaged Ventilator

A. NU2035 HRV Specifications NU2035

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

AIR-AIR ENERGY CONSERVATION MODULE

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Square Inline Fans with Multi-Directional Discharge

Variable Air Volume (VAV) Pressure Independent Control

Direct Fire Heated Make-Up Air Unit

Prepared By : Checked By : Approved By : Page 1 out of 6

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

Warm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Model: G-143-VG. CAPS Z:\Carl\winjobs\Alley 111.gfcj Page 6 of 18

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

G76x Direct Spark Ignition Controls

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

Inline and Roof Mounted Fans

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

D M S 760 C01 A A 1 1

Centrifugal Filtered Supply Roof Blowers

SECTION AXIAL HVAC FANS

FILTERED SUPPLY CENTRIFUGAL Belt Drive

High Performance Fan Coils FCHG Genesis Series Horizontal

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Twin City Fan & Blower

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

1005 MOUNT VERNON AVE. CITY OF ALEXANDRIA, VA 22301

Installation, Operation and Maintenance Instructions. ERV1500e ERV2000e ERV3000e

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

SPECIFICATION SHEET. C5000 ( cfm)

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Axial Propeller Panel Fans, PAF-Series

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

RCD Air Cooled Condensing Unit (50/60 Hz)

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

XeteX, Inc. All Rights Reserved.

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Tubular Centrifugal Fans

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

Transcription:

Mark: ASP 1 Model: ASP - 52.00 - S ASP Air Curtain Supply (ASP) Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP) 52 14 10 740 0.13 Supply Collar Data: Collar # Collar Size (LxW) in. or Diameter (in.) Pos. Off Left Pos. Off Front Velocity (fpm) Mounting 1 22 x 10 26 7 484 Factory Mounted Supply Collar(s) Selected Options & Accessories: 430 Stainless Steel MBD(s) in Plenum CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 1 of 16

Mark: ASP 1 Model: ASP - 52.00 - S 7.0 10.0 22.0 26.0 26.0 MARK: ASP 1 14.0 10.0 PERFORATED AIR CURTAIN CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 2 of 16

Mark: ASP 2 Model: ASP - 84.00 - S ASP Air Curtain Supply (ASP) Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP) 84 14 10 1260 0.15 Supply Collar Data: Collar # Collar Size (LxW) in. or Diameter (in.) Pos. Off Left Pos. Off Front Velocity (fpm) Mounting 1 18 x 10 21 7 504 Factory Mounted Supply Collar(s) 2 18 x 10 63 7 504 Factory Mounted Supply Collar(s) Selected Options & Accessories: 430 Stainless Steel MBD(s) in Plenum CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 3 of 16

Mark: ASP 2 Model: ASP - 84.00 - S 7.0 10.0 10.0 18.0 18.0 21.0 42.0 21.0 MARK: ASP 2 14.0 10.0 PERFORATED AIR CURTAIN CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 4 of 16

Model: DG-109-H10 DG-109-H10 Unit Performance Design Conditions Elevation (ft) Summer DB ( F) WB ( F) Winter ( F) Supply (CFM) Outdoor Air (CFM) 692 91.2 77.2-0.3 2,000 2,000 Unit Specifications Weight (lb) Cooling Type Heating Type Unit Installation Unit ETL Listing 482 (+/- 5%) None Direct Gas-Fired Outdoor/Indoor ANSI Z83.4 / CSA 3.7 Configuration Unit Orientation Unit Configuration Outdoor Air Intake Return Air Intake Supply Air Discharge Horizontal Constant Volume 100% OA End - Bottom Heating Specifications Gas Pressure Capacity (MBH) Performance Temperature Type Gas Type Min Max Input Output Rise ( F) EAT ( F) LAT ( F) (in. wg) (Psi) Direct Gas Natural 7 0.5 165.1 151.9 70.3-0.3 70.0 Air Performance Total Fan External SP Total SP Operating Type Volume RPM (in. wg) (in. wg) Power (hp) (CFM) Qty Type Size (in.) Drive-Type Supply 2,000 0.4 1.201 1302 1 1 Forward Curve 9 Belt-Drive Motor Specifications Motor Qty Size (hp) Enclosure Efficiency RPM Supply Fan Motor 1 1-1/2 ODP NEMA Premium 1725 Electrical Specifications Power Supply Rating (V/C/P) MCA (A) MOP (A) Unit 208/60/3 8.9 15 CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 5 of 16

Model: DG-109-H10 CONSTRUCTION FEATURES AND ACCESSORIES Unit Unit Installation - Indoor or Outdoor Unit Construction - Single Wall Wall Insulation - 1in. fiberglass - Heat source on Base Insulation - 1in. fiberglass - entire unit base pan Corrosion Resistant Fasteners Access and Connections - Right side when facing intake Service Access - Removable lift off panels Unit Finish - G90 Galvanized Finish Color Supply Fan - Belt-drive, forward-curved Supply Fan and Motor Vibration isolation - Neoprene Controls Unit Controls - Terminal strip Remote Panel Temperature Control - Discharge control Supply Fan VFD Supply Fan Control Melink/Vari-Flow wiring package Recirculation Control Unoccupied Mode (Night Setback) Control Accessories Heating Inlet Air Sensor Cooling Inlet Air Sensor Dirty Filter Switch Fire Stat Type III (Ships loose) 120V/24V Smoke Detector (Ships loose) Inlet Damper End Switch External Cooling Lockout Relay Freeze Protection (Supply Air Low Limit) Auxiliary Supply Starter Contacts Auxiliary Exhaust Starter Contacts Airflow Proving Monitoring Contact Std Std Std Accessories Factory Installed, Lockable, NEMA 3R Disconnect Weatherhood - Aluminum Mesh filtered Supply Air Filters Outdoor Air Inlet Damper Supply Air Outlet Damper Diffuser Roof Curb - GPI Combination Curb Spare Belts Spare Filters Motor with Shaft Grounding Service Outlet Gas Heating Accessories Pilot Ignition Flame Sensing - Flame rod Flame Safeguard Display Agency Approval - ETL and IRI FM Approved Minnesota Code Requirements High Gas Pressure Switch Low Gas Pressure Switch Visual Indication Valves External Gas Pressure Regulator (Ships loose) Warranty Options Unit Warranty - 1 Year 5 Year Burner Warranty 10 Year Burner Warranty Std Std Std Standard Option Std Not Included Included CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 6 of 16

Model: DG-109-H10 Fan Charts And Performance Supply Fan Performance Motor Fan Total Volume External SP Total SP Operating RPM (CFM) (in. wg) (in. wg) Power (hp) Size Qty Qty Type Drive-Type (hp) 2,000 0.4 1.201 1302 1 1 1-1/2 1 Forward Curve Belt Pressure Drop (in. wg) Weatherhood Filter Damper Cooling Heating External Total 0.089-0.087-0.625 0.4 1.201 Sound Performance in Accordance with AMCA Sound Power by Octave Band 62.5 125 250 500 1000 2000 4000 8000 Lwa dba Sones 92 92 82 75 73 70 69 64 81 70 18.8 Supply Fan CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 7 of 16

Model: DG-109-H10 Heating Specifications Heating Performance Gas Pressure Capacity (MBH) Performance Temperature Type Gas Type Min Max Input Output Rise ( F) EAT ( F) LAT ( F) (in. wg) (Psi) Direct Gas Natural 7 0.5 165.1 151.9 70.3-0.3 70.0 Gas Train Details Redundant Electronic Main Modulating Valves Valve Pilot Valve Internal Regulator Visual Indication Valve Proof of Closure Valve Hydraulic Gas Pressure Main Valve(s) Switch(es) External Regulator Std Std Std Std - - - - - Additional Heating Information Agency Approvals ETL and IRI Temperature Control Ignition Control Flame Safeguard Display Minnesota Flame Sensing CO2 Sensor FM Approved Code Std - - Discharge Flame Rod Pilot - - Unit Details 92% thermal efficiency Cast aluminum burner manifold with stainless steel mixing plates Electronic modulation burner control 10 second pre-purge sequence Low fire start ELECTRICAL CONNECTION Gas Connections 39.500 8.000 3/4" NPT GAS CONNECTION 8.000 39.500 CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 8 of 16

Model: DG-109-H10 31.693 78.192 33.676 ELEVATION VIEW *Standard configuration for unit access is on the right-hand side, when looking into the unit intake in the direction of airflow. *Note: Order of unit sections is from intake of unit to discharge of unit. *Sections included on this unit: Weatherhood Section, Heating Section *Insulation: Duct Liner, from Burner Section through end of unit. INTAKE BURNER 31.698 78.192 SUPPLY DUCT 14.00027.473 6.737 ACCESS SIDE- CONTROL CENTER 6.971 13.000 PLAN VIEW * Standard configuration for unit access is on the right-hand side, when looking into the unit intake in the direction of airflow. CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 9 of 16

Model: DG-109-H10 27.473 END VIEW NOTE: Roof Opening Requirements: Minimum Roof Opening: The minimum roof opening size is the illustrated duct diameter plus 0.25 in. on all sides. For example: If the duct size is 14 x 14 in. square, the minimum roof opening size is 14.5 x 14.5 in. square. Maximum Roof Opening: There must be a minimum perimeter of 1.75 in. between the roof opening and the roof curb. For example: If the roof curb is 75 x 30 in. square, the maximum roof opening is 71.5 x 26.5 in. inches square. 74.500 CURB LENGTH ACTUAL 13.000 Supply Duct 5.25 5.25 14.000 24.500 CURB WIDTH ACTUAL 5.47 NOTE: The weatherhood and filter sections of the make-up air unit extend beyond the curb. This is by design, to prevent water infiltration. MUA Unit supports are shipped loose with unit. FOOTPRINT VIEW CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 10 of 16

Model: DG-109-H10 UNIT BASE 1.00 1.63 INSULATION 0.34 1.15 CURB INSIDE OF RAILS 25.18 CURB VIEW Notes: All dimensions shown are in in.'s. Curb Dimenision: Length = 74.5 in. Width = 24.5 in. Height = 20 in. Recommended Minimum Combustible Clearances Floor Top Sides Ends Insulated/Units 0 in. 0 in. 0 in. 0 in. Non-Insulated/Units 0 in. 6 in. 6 in. 6 in. Clearance to combustibles is defined as the minimum distance required between the heating source and the adjacent combustible surfaces to ensure the adjacent surface's temperature does not exceed 90 F above the ambient temperature. Housing 32 and less Recommended Minimum Service Clearances 42 in. on the controls side of the unit Housing 35 and higher 48 in. on the controls side of the unit To ensure ample space for component removal (evaporative cooling media, coils, filters, etc.), service clearances should be 6 in. wider than the width of the module itself. CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 11 of 16

Model: DG-109-H10 MAIN POWER TO UNIT 208V GROUND L1 L2 L3 DS1 T1 T2 T3 ST1 O.L. L1 T1 L2 T2 L3 T3 M1 SUPPLY FAN MOTOR A C C U R E ENGINEERED RESTAURANT SYSTEMS 111 112 Wiring Diagram Code: AD61N401A010N10NM19 CAUTION UNIT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. POWER MUST BE OFF WHILE SERVICING. NOTES USE COPPER CONDUCTORS ONLY 60 C FOR TERMINALS RATED LESS THAN 100 AMPS. 75 C FOR TERMINALS RATED 100 AMPS OR MORE. FIELD CONTROL WIRING RESISTANCE SHOULD NOT ECEED 0.75 OHM. FIELD WIRED TR5 FACTORY SUPPLIED AND WIRED 40VA 24V WIRE COLOR CODE BLUE R S2 FSC G PINK ST1 O.L. 95 96 TR1 24V 22 21 75 VA C RED BLACK D1 INLET DAMPER 2CBL-ID 2CBL-ID PINK PINK 4 RF SUPPLY FAN RELAY A2 A1 WHITE BK BLACK BL BLUE BR BROWN GY GRAY LT BL LIGHT BLUE O ORANGE PK PINK PR PURPLE R RED W WHITE Y YELLOW LEGEND AMP AMPLIFIER D1 INLET DAMPER DS1 MAIN DISCONNECT SWITCH FSC FIRE SYSTEM CONTACT FSG FLAME SAFE GUARD HLC HIGH LIMIT CONTROL M# MOTOR MOD MODULATING VALVE OL# MOTOR OVERLOAD PS2 AIR PROVING SWITCH RF SUPPLY FAN RELAY RH HEAT RELAY S2 FAN SWITCH S4 HEAT AND COOL SWITCH SG SPARK GENERATOR ST# MOTOR STARTER TR# TRANSFORMER TS2 DISCHARGE AIR SENSOR TS4 INLET AIR SENSOR - HEAT V1 PILOT VALVE V2 MAIN VALVE RF 11 14 BROWN ST1 A2 A1 SUPPLY FAN S4 W1 RED 13 ST1 14 RED R TS4 B RED A2 RH A1 POST HEAT RH HLC1 RED RED R R 22 23 24 11 14 PS2 PS2 RED BLACK C NO NC C RED 27 O 21 DIRECT GAS CONTROL SENSOR SPARK SENSE SPARK TH/24V FSG MV PV GND (BURNER) GND (24V) WHITE 29 LT BLUE V1 WHITE BLUE ORANGE WHITE 37 V2 TR6 INT 10 SEC AMP 7 DISCHARGE STAT. TEMP RANGE 55-90 F 39 BLUE 30 VA 24 VAC 1 2 3 4 5 6 8 38 YELLOW BLACK WHITE BLUE BLUE TS2 1 2 MOD Wiring Template: M19 DOC NUMBER: ---- REV: ---- Manufacturer reserves the right to change, modify, or improve this product at anytime CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 12 of 16

Roof Curb - GPI CONSTRUCTION FEATURES Welded aluminum (0.064 in.) or galvanized steel (18 ga.) Straight sided 2 in. mounting flange 1 in., 3 lb. density insulation Wood nailer Dimension Description Value (in.) A Length 74.5 B Width 24.5 C Height 20 * All dimensions are actual GPI Curb Weight: 64 lb Printed Date: 11/02/2018 Model: DG-109-H10 ADDITIONAL NOTES The Roof Opening Dimension may NOT match the Structural Roof Support Dimension. Curbs with length > 143.5 will ship knocked-down Curbs with length > 119.5 may ship knocked-down, dependent on manufacturing location CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 13 of 16

Model: DG-109-H10 Corner Weights 133 lb 96 lb 146 lb 106 lb Note: Estimated corner weights are shown looking down on unit and airflow from left to right. Weights are applied at the base of the unit. Images not drawn to scale. CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 14 of 16

Model: DG-109-H10 Unit Controls The unit shall be provided from the factory with: SEQUENCE OF OPERATIONS 24VAC Transformer Terminal Strip Supply fan motor starter (contactor and overload) Factory mounted and wired outdoor air inlet damper with actuator Field Provided Control Requirements The following field provided control signals must be provided for proper operation of the unit (Reference the unit wiring diagram for additional information): Supply fan enable Contact closure between R and G (24VAC) Heating enable Contact closure between R and W1 (24VAC) Unit Start-Up Sequence Supply Fan Enable Is Received Outdoor air inlet damper actuator is energized Supply Fan Is Enabled Supply Fan Sequence The supply fan is configured for constant volume operation. The fan speed is set to the design fan RPM at the factory through the use of belts and sheaves. Adjustment or replacement of belts/sheaves is necessary to balance the supply airflow. The supply fan speed is not to be modulated. Heating Control A heating enable signal must be present and the supply fan must enabled before the unit will enable heating. Heating Inlet Air Sensor (Heating Lockout) The heating will be locked out when the outside air temperature is above the heating inlet air sensor set point (typical 65 F, adj.) Direct Gas Fired Heating (Discharge Control) The gas control amplifier located in the unit shall modulate the heating to maintain a supply temperature set point (55 F-90 F, adj.). The set point is adjusted in the unit control center. CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 15 of 16

Model: DG-109-H10 Warranty Information Limited Warranty - Unit Accurex warrants this equipment to be free from defects in material and workmanship for a period of 1 year(s) from the purchase date. Any component which proves defective during the warranty period will be repaired, or replaced, at Accurex's sole option when returned to our factory, transportation prepaid. The warranty does not include labor costs associated with troubleshooting, removal, or installation. Accurex will not be liable for any consequential, punitive, or incidental damages resulting from use, repair, or operation of any Accurex product. This warranty is exclusive, and is in lieu of all other warranties, whether written, oral or implied, including the warranty of merchantability and the warranty of fitness for a particular purpose. CAPS 4.27.1793 C:\Users\holbrook\Syncplicity Folders\Acx-OH\2018 Jobs\skyline Chili\Skyline Chilli.acxj Page 16 of 16