Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

Similar documents
OPERATION MANUAL. THE JENCO MODEL 3671 ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

ECscan20 Pocket Conductivity Tester Instruction Manual

TDSscan10M Pocket TDS Tester Instruction Manual

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

PHscan30S Pocket ph Meter Instruction Manual

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

PHscan10S Pocket ph Tester Instruction Manual

ORPscan20 Pocket ORP Tester Instruction Manual

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

Bante220 Portable ph Meter Instruction Manual

Large Display ph Pens , , Instruction Manual

EC1 Pocket Conductivity Tester Instruction Manual

EC20 Pocket Conductivity Tester Instruction Manual

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Salt 1 Pocket Salinity Tester Instruction Manual

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

PH60 Series Premium ph Testers

WalkLAB Digital Dissolved Oxygen meter HD9030

Model P772 Conductivity Meter. User Manual

PH20 Value ph Tester Instruction Manual

Thermistor Thermometer MODEL NO

Dip Tester Model DS-03

Instruction Manual. Single-Input Thermistor Thermometer (Model )

Model 2053 Conductivity Meter Instruction Manual

Tracer ORP PockeTester TM Code 1742

HI Ethylene Glycol Refractometer INSTRUCTION MANUAL

Temp-14 Single Input Thermistor Thermometer

STARTER 2000 Bench ph Meter Instruction Manual

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

COM-100 EC / TDS / TEMPERATURE METER

SoilStik ph Meter PRODUCT MANUAL. Item # 2105

TRACER. POCKETESTER ä ORP CODE 1742

Thermocouple Thermometer Models

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

Barnant Company (Type J) (Type K) (Type T)

Sunleaves TDS Expert Plus

ROTARY HEAD DIGITAL STEM THERMOMETER

Instruction Manual Portamess 911 Cond

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

OPERATION MANUAL PEN TYPE. Model: 8690 DESIGN PATENTED: US D S

IAQ-CALC TM Indoor Air Quality Meter

Marin Control Digital

MODEL IQ150 ph Meter Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE

Indoor Air Quality Meter

Single-Input Thermocouple. Thermometers Type J, K, T

IAQ-CALC TM Indoor Air Quality Meter

Defender 3000 Series Base Instruction Manual

OPERATING MANUAL THERMAL SENSITIVITY TESTER NTE-2A CONTENTS

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

User's Guide. CO 2 Meter. Model CO250

Care and use guide Guía de uso y cuidado Guide d utilisation et d entretien.

(Type J) (Type K) (Type T)

THREE RANGE DS METERS Operation Instructions

NOTES TO USERS. INSTRUCTIONS Installation/Operation/Maintenance

Compact Scales. Software Revision V1.25 & above

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

Model Battery Powered Milliohm Meter

Care and use guide. Contents. page

Visit us at

Megohmmeter Test Probe

INSTRUCTION MANUAL. Handy Polaris

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

Instruction Manual. ph Meter D-51

Budget Series Digital Thermometer. Instruction manual Models 874F/C, 875F/C, 878 and 879

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Cole-Parmer Pro-Spense

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

DUAL RANGE DIALYSATE METER Operation Instructions User Manual for Models D-2

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Digital Thermometers Instruction Manual MODELS 868 and 869

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Instruction Manual PORTABLE ph METER D-71

DigiTemp. Digital Thermometer

4&5 RANGE CONDUCTIVITY METERS Operation Instructions

User Guide. Model Insulation Tester / Megohmmeter. Introduction

1.0 Introduction Mounting Procedure Verifying Calibration Accuracy Specifications Tension Ranges...

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

VELOCICALC Air Velocity Meter

Sonic Meter. Soni. Operating Manual. Rev. A

User Manual Pocket Pro, Pro + ph

Model 7400 OPERATOR MANUAL

Care and use guide. Contents. page

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

ACCURACY RELIABILITY SIMPLICITY

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

AXD 530 MicroManometer

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

SERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER 3100C Bench ph Meter

OPERATING MANUAL TS - 4 Thermal Microscope Stage

CALIBRATION TEST FIXTURES

Model 8000XL OPERATOR MANUAL

Instruction Manual IVT-10 / IVT-20 Voltage Tester

Electrostatic Fieldmeter

PLATINUM. PREMIUM CLASS pocket scale. Manual & Operation Guide

Digital/Analog Megohmmeter Model 1026 USER MANUAL

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Transcription:

Operation Manual MODEL EC331 Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

CONTENTS INITIAL INSPECTION AND ASSEMBLY...2 VISIONPLUS EC331 OVERVIEW...2 A. Meter Description...2 B. LCD Display...2 OPERATION MODES AND KEYPAD OPERATIONS...3 A. Operation Modes...3 B. Keypad Operations...3 BEFORE YOUR FIRST USE... 4 A. Insert Batteries...4 B. Soak the Electrode......4 C. Preparing Standard Solutions...4 D. Setup and Calibrate the Electrode and Meter...5 USING VISIONPLUS EC331...5 A. Power on/off...5 B. Calibrate Conductivity...5 C. Measure...5 D. Hold Data...5 REPLACE ELECTRODE...6 REPLACE THE OLD BATTERIES...6 ERROR DISPLAYS AND TROUBLESHOOTING...7 SPECIFICATIONS...8 WARRANTY...9 1

R INITIAL INSPECTION AND ASSEMBLY Carefully unpack the instrument and accessories. Inspect for damages made in shipment. If any damage is found, notify your Jenco representative immediately. All packing materials should be saved until satisfactory operation is confirmed. VISIONPLUS EC 331 OVERVIEW A. Meter Description Hold Cal Mode VisionPlus EC 331 1 2 3 1. Battery cover 2. LCD screen 3. Keypad 4. Electrode collar 5. Electrode & ATC assembly (Electrode cap is not shown.) 4 5 B. LCD Display 1 2 3 4 5 6 7 8 9 1. LOW BATTERY indicator 2. CALIBRATION mode indicator 3. MEASURE mode indicator 4. HOLD mode indicator 2

5. CONDUCTIVITY/RESISTIVITY mode indicator 6. CONDUCTIVITY/RESISTIVITY unit indicator 7. CONDUCTIVITY/ RESISTIVITY reading 8. TEMPERATURE reading 9. TEMPERATURE unit indicator OPERATION MODES AND KEYPAD OPERATIONS A. Operation Modes VisionPlus EC331 meter has 3 operation modes: 1. Measure Mode. Measure Mode is used to make all conductivity or resistivity and temperature measurements. 2. Calibration Mode. Calibration Mode is used to perform one point calibration. 3. Hold Mode. Hold Mode is used to display the locked reading for increased ease of use. B. Keypad Operations Key Hold Operation Mode Measure Duration Function 0 second Holds current measurement reading. Press again to resume measuring. Hold 0 second Returns to Measure Mode. Measure 5 second. Erases all stored data. Cal Measure 0 second Enters Calibration Mode. On/Off All 0 second Turns meter on/off. Mode Measure 0 second Selects display mode: Conductivity ( ), Conductivity ( ), Resistivity( ) and Resistivity( ). 3

BEFORE YOUR FIRST USE A. Insert Batteries 1. Remove the battery cover at the top of the unit. 2. Insert the set of batteries (included) ensuring correct polarities. 3. Securely replace battery cover. 1 2 B. Soak the Electrode 1. Remove the electrode cap covering the VisionPlus EC331 meter. 2. Soak the electrode in distilled water for 10 minutes before first use or after storage. C. Preparing Standard Solutions Suitable conductivity standards are available commercially or the user can prepare them using research grade reagents. Here is the 147.0uS standard solution the user can prepare to calibrate the probe of the model EC331. Standard solution of 147.0uS at 25 : Accurately measure 100mL of the 1413uS conductivity standard solution. Dilute with 900ml of distilled water. (Standard solution of 1413uS at 25 : Accurately weight out 0.746 grams of research grade dried Potassium Chloride (KCL). Dissolve in 1000ml of distilled water.) [Note: You can store the remaining solution in a plastic container for one week but the air space between the cap and the solution must be kept to an absolute minimum. Storing the excess solution below 4 can increase the storage life. If you have any doubt of the accuracy of the stored solution, a fresh batch should be prepared.] 4

D. Setup and Calibrate the Electrode and Meter VisionPlus EC331 must be setup and calibrated before your first use. Please follow the instructions detailed in section USING VISIONPLUS EC331 6. USING VISIONPLUS EC331 A. Power On/Off Press On/Off key to turn the unit on. If the unit is running then you can press On/Off key to turn the unit off. The unit will automatically turn off after 10 minutes of no key activity. [Note: The unit will not automatically shut off if it is still immersed in solution even after 10 minute of no key activity.] B. Calibrate Conductivity 1. Rinse the electrode & ATC assembly in distilled water and immerse them in the standard solution of 147uS. The temperature displayed is the solution temperature. 2. Press Cal key to initiate calibration. The CAL icon will appear when the main display shows 147.0. Calibration is now complete. The MEAS icon will appear. The unit is now ready to measure. C. Measure In the Measure Mode, dip the meter into the test solution. Measuring for Conductivity ( ) commences. Press Mode key to select: Conductivity( ), Conductivity( ), Resistivity ( ) and Resistivity ( ). [Note: If the CAL icon does not appear during measuring, it means the unit has not been calibrated. Repeat the calibration procedure.] D. Hold Data 1. When the Conductivity or Resistivity reading is stable, press Hold key once to lock the reading. 2. Press Hold key again to unlock reading and the unit will 5

return to Measure Mode. The unit is now ready for another measurement. REPLACE ELECTRODE 1. Unscrew the electrode collar to remove the electrode & ATC assembly as shown in the right figure. 2. Remove the old electrode from the meter. 3. Insert a new electrode, make sure the electrode fit back into the meter correctly. 4. Screw back the electrode collar. 5. Soak the electrode in distilled water for 10 minutes and recalibrate the EC331 following the instructions detailed in section USING VISIONPLUS EC331. REPLACE THE OLD BATTERIES Replace the battery when the blinking low battery indicator appears on the upper left corner of the LCD screen. The instrument can operate within specifications for approximately 2~3 hours after low battery indicator appears. 1. Take off the battery cover. 2. Remove all of the old batteries and insert a new set of batteries ensuring the polarities are correct. [Note: Calibration of the unit is required after replacement of batteries.] 6

ERROR DISPLAYS AND TROUBLESHOOTING Conductivity Display ATC Displayy DISPLAY Mode "OVER" "OVER" Measure "OVER" "udr" Measure "OVER" 60.0 ~ 99.5 C Measure Possible cause(s) [Action(s)] Temperature >99.5 C range. [Bring solution to a lower temperature.] [Replace electrode & ATC assembly.] Temperature <0.0 C range. [Bring solution to a higher temperature.] [Replace electrode & ATC assembly.] Temperature >60.0 C, over the temperature compensation range. [Bring solution to a lower temperature.] "OVER" 0.0 ~ 60.0 C Measure The conductivity value of the test solution is beyond 200uS. [Sample cannot be tested or replace electrode & ATC assembly.] "ERR" / Calibration a. Temperature exceed 0 ~ 60.0 C Temperature compensation b. Correction of slope beyond 50%. [Bring solution to a lower temperature.] [Use a new standard solution.] [Replace electrode & ATC assembly.] 7

SPECIFICATIONS Conductivity Range Resolution Accuracy 0.1 to 199.9uS 0.1uS (0.0~ 50.0uS), 0.5uS (50.0~ 100.0uS) and 1.0uS typical (100.0~199.0uS) ±1% FS Resistivity Range Resolution Accuracy 1.0~20.0MΩ 0.1MΩ ±1% FS Temperature Range Resolution Accuracy 0.0 to 99.5 C 0.5 C ±0.5 C 32 to 212 F 1 F ±1 F Conductivity Temperature compensation Temperature Coefficient Reference temperature AUTO 0.0 C to 60.0 C 1.91%/ C 25 C Temperature Temperature sensor Thermistor, 10 kωat 25 C Temperature unit C and F General Power: LR44 x 4 Battery life: >100 Hours Ambient temperature range 0.0 to 50.0 C Case IP67 water-tight case Weight 105 g 8

WARRANTY Jenco warrants this product to be free from significant deviations in material and workmanship for a period of 1 year from date of purchase. If repair or adjustment is necessary and has not been the result of abuse or misuse, within the year period, please return-freight-prepaid and the correction of the defect will be made free of charge. If you purchased the item from our Jenco distributors and it is under warranty, please contact them to notify us of the situation. Jenco Service Department alone will determine if the product problem is due to deviations or customer misuse. Out-of-warranty products will be repaired on a charge basis. RETURN OF ITEMS Authorization must be obtained from one of our representatives before returning items for any reason. When applying for authorization, have the model and serial number handy, including data regarding the reason for return. For your protection, items must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Jenco will not be responsible for damage resulting from careless or insufficient packing. A fee will be charged on all authorized returns. NOTE: Jenco reserves the right to make improvements in design, construction and appearance of our products without notice. 9

Jenco Instruments, Inc. 7968 Arjons Drive, Suite C San Diego, CA 92126 USA TEL: 858-578-2828 FAX: 858-578-2886 E-Mail: jencoinfo@jencoi.com; sales@jencoi.com Website: www.jencoi.com Jenco Electronics Inc. 1F., No.11, Lane 370, Sec. 6, Zhongxiao E. Rd. Nangang Dist., Taipei City 115,Taiwan Taipei, Taiwan TEL: 886-2-2782-3226 FAX: 886-2-2782-3234 Shanghai Jenco Instruments, Ltd. 18 Wang Dong Zhong Road Sijing Town, Songjiang Shanghai, China 201601 TEL: 86-021-5761-9599 FAX: 86-021-5761-9598 E-Mail: jencos@jenco.com.cn Website: www.jenco.com.cn 10