Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

Similar documents
INTERNATIONAL METAL ENGINEERING

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

DigiTemp. Digital Thermometer

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

Thermocouple Thermometer Models

PTC8001 Temperature Calibrator

UNIVERSAL CALIBRATOR M

Barnant Company (Type J) (Type K) (Type T)

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Single-Input Thermocouple. Thermometers Type J, K, T

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

DT304. Digital Temperature Logger INSTRUCTION MANUAL

HUMIDITY / TEMPERATURE TRANSMITTER

SR1V. Industrial Low Cost String Pot

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Price Computing Scale D Series Operation Manual

IAQ-CALC TM Indoor Air Quality Meter

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

AXD 530 MicroManometer

LTX RF LEVEL SENSOR. Instruction Manual

Valor 2000 Series Instruction Manual


Model 2053 Conductivity Meter Instruction Manual

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

(Type J) (Type K) (Type T)

Indoor Air Quality Meter

Omnigrad TA20, TA21. Technical Information. Temperature Measuring Technology Terminal heads for mounting on thermowells of resistance thermometers

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

DC POWER SUPPLY ALIMENTATION C.C.

Volt/mA Calibrator. Manual

Differential Pressure Transmitter

TMD90A Dual Input Digital Thermometer

Thermistor Thermometer MODEL NO

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

DIGI-TEL THERMOMETERS

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Pressure Transmitter

1100 Series Piston Type Differential Pressure Gauges

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Instruction Manual. Single-Input Thermistor Thermometer (Model )

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

SITRANS P measuring instruments for pressure

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

Signet Pressure Transmitter

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

TEL-TRU MANUFACTURING COMPANY DIGITAL THERMOMETERS

Model DS7060 Handrail Scale. User Manual

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Tubeskin thermocouple assembly Model TC59-V

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Intelligent NiMH/NiCd/Li-ion Charger TN456

PIECAL 520B & 521B Thermocouple Source Operating Instructions

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

Digital Pressure Gauge / Pressure Switch

IAQ-CALC TM Indoor Air Quality Meter

Special Purpose Transmitters

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety

Type 2000 Transducer Product Instructions

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Portable pressure calibrator, Wally Box III Model CPH7600

OEM Pressure Transmitters

Date received into service; / /.

707Ex. Users Manual. ma Calibrator

Tubeskin thermocouple assembly Model TC59-W

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

DST600 Series Digi-Stem Thermometers

6 Bay Battery Charger Operation Manual

KMP7010. Ground Resistance Tester. Users Manual

OPERATING INSTRUCTION

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Defender 3000 Series Base Instruction Manual

FL-100-R (109) Operations and Installation Manual

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

MODEL K WIRE INDICATING PRESSURE TRANSMITTER INTRINSICALLY SAFE VERSION OPERATION AND INSTRUCTION MANUAL

B-RAD Select USER MANUAL TABLE OF CONTENTS

Rosemount 4088 MultiVariable Transmitter

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

(((temporary title page))) Please read these instructions before using your FS/GS HUSKY FS/GS USER LEAFLET

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

operating manual DL7 101 DIGITAL THERMOMETER

Users Manual. Airflow Meter

Rosemount 4088 MultiVariable Transmitter

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Transcription:

Burns Connection Head Models #, # & # Burns Connection Head Models #, # & # with Battery Powered LCD Indicator Instruction Manual Contents Introduction General Receiving Specifications General RTD At 0 C Thermocouple At 0 C Mechanical Installation Mechanical Mounting Temperature Environment Moist or Corrosive Atmospheres Hazardous Locations Electrical General Recommendations Battery Installation Battery Warning Wiring Configuration Menu General Menu Maintenance Repair and Warranty Service 6 6 Illustrations Figures Indicator Dimensions (fig.1) Burns Connection Head Dimensions # (fig.) # (fig.) # (fig.) RTD Wiring Schematic (fig.) Thermocouple Wiring Schematic (fig.6) Switch Location (fig.7) Enter and Escape Schematic (fig.8) RTD Menu Schematic (fig.9) Thermocouple Menu Schematic (fig.10) While this information is presented in good faith and is believed to be accurate, Burns Engineering cannot guarantee satisfactory results from reliance upon this information. For complete warranty information, please request a copy of Burns Engineering form #071 Terms and Conditions of Sale www.burnsengineering.com Burns Engineering Inc. 1001 Bren Road East Minnetonka, Minnesota For assistance call 800-8-871 9-9-00 FORM 01107 01/10 1

Burns Connection Head Models #, # & # Introduction -General The Burns #, # and # connection heads use either the RTD or Thermocouple version of the battery powered process indicator with a -digit red LCD display. The instrument configuration settings are selectable via a simple to use menu system, which is navigated by the use of three push bottom keys located on the rear of the indicator display. The indicator assembly is sealed into a cap that fits directly onto Burns #, # and # connection heads. -Receiving Please inspect the packaging and instrument thoroughly for any signs of transit damage. If the part has been damaged, please notify your supplier immediately. Specifications -General Display: digit, 7.6mm, red LCD Decimal Point: Programmable Display Capability: -1999 to 9999 Password protection Battery Standard: ANSI AA ER10: IEC ER6 Type:.6 V Lithium Thionyl Chloride (. A/Hr.) Operating Current: 80mA average Battery Life: > years EMC Emissions: BS EN616 RTD Sensor Type: -wire Pt100 or Ni10 Thermocouple Sensor Type: K, T, J, N, R, S, E, F Ambient Humidity: 10 to 90% RH -RTD At 0 C Resolution: 0.1 C Accuracy: ±0. C ±0.1% of reading (plus sensor error) Lead Effect: 10W per leg insignificant effect Measuring Range: -100 to 800 C Stability Zero: ±0.01 C/ C Stability Span: 0 ppm/ C Ambient Temperature: -10 to 70 C Ambient Storage: -0 to 8 C -Thermocouple At 0 C Resolution: 0.1 C Accuracy: ±0.1% of FS ±0. C (plus sensor error) Measuring Range: Type K: -00 to 170 C Type T: -10 to 00 C Type J: -100 to 100 C Type N: -10 to 100 C Type R: -10 to 1760 C Type S: -10 to 1760 C Type E: -00 to 1000 C Type F: -100 to 600 C Stability Zero: ±0.0 C/ C Stability Span: 100 ppm/ C Ambient Temperature: -10 to 70 C Ambient Storage: -0 to 8 C -Mechanical Connection: Three way screw terminal block Wire Size: 18 - AWG typical Dimensions: Diameter 1.mm, length 0.mm Environmental Rating: IP67 Approval (Burns#): FM explosion proof Approval (Burns #): NEMA X 1-800-8-871

Burns Connection Head Models #, # & # Material (Burns#): Aluminum, blue polyester powder coating Material (Burns #): Polycarbonate Material (Burns #): Stainless Steel Figure 1 Indicator Dimensions 66.mm (.60 ) Figure Burns Connection Head # Dimensions 11.mm (.0 ) 1.mm (0.8 ) 7.8mm (.9 ) 66.mm (.60 ) 11.mm (.78 ) 96.8mm (.81 ) Figure Burns Connection Head # Dimensions Installation Mechanical -Mounting The entire indicator assembly is sealed in the cap that fits directly into the Burns # Explosion proof, # NEMA X, and # Stainless Steel connection heads. The sensor may be fixed directly to the connection head, or remotely connected using cable and gland. Cable length must be no longer than 6 feet to comply with certifications. All external cabling/sensor entries must maintain IP67 rating. 77.mm (.0 ) 6.mm (. ) 9.mm (.7 ) Figure Burns Connection Head # Dimensions -Temperature Environment The indicator assembly will operate within specifications for ambient temperatures in the range of -10 C to 70 C (1 F to 18 F). It can be stored without damage at temperatures in the range of -0 C to 8 C (- F to 18 F). -Moist or Corrosive Atmospheres The Burns Connection Head Model # has been designed to resist moisture and corrosive environments. However, during prolonged exposure, corrosion of the screws can occur. Significant corrosion to the screws can increase the contact resistance between the PRT/ power supply leads and the terminal block, causing www.burnsengineering.com

Burns Connection Head Models #, # & # erroneous readings and/or complete lack of output. Replacing and/or cleaning the screws will usually remedy the problem -Hazardous Locations The Burns Connection Head Model # is FMRC approved as an intrinsically safe device when used with properly selected FMRC approved assemblies. -Wiring The terminal block accepts 18 AWG to AWG wire. See Figure for proper RTD connections and Figure 6 for proper Thermocouple connections. Use correct compensating wire. All external cabling/sensor entries must maintain IP67 rating. Figure RTD Connection Installation Electrical -General Recommendations Please observe the battery warning. Ensure the instrument is installed with adequate protection against the environment. IP67 rating must be maintained. Avoid installing the equipment close to sources of extreme temperature and electromagnetic interference. INC DEC + - CYC -Battery Installation To install battery, first gain entrance to the battery by unscrewing the connection head cap retaining nut and removing cap from base. To remove old battery, ease out the positive end of the battery from the holder, using a screw driver blade. To fit battery, insert battery negative into the spring contact end of the battery holder BH1, then press battery into place. INC DEC Figure 6 Thermocouple Connection + - CYC - (negative, red t/c wire) + (possitive t/c wire) The device monitors their batteries. When the battery approaches the end of it s lifetime (over years under normal conditions), the display will toggle the message LO BAT. -Battery Warning NEVER short circuit the battery Fire, Explosion and severe burn hazard, DO NOT Recharge, Crush, Disassemble, Heat above 100 C (1 F), Incinerate or expose contents to water. Disposal, the battery may be regulated by national and local regulations. Please follow the instructions of the proper regulator. 1-800-8-871 Configuration Menu -General There are three buttons, which the operator must press in various combinations in order to configure the device. These buttons are located on the underside of the indicators circuit board. Viewed from the front the three buttons, cycle (CYC), Increment (INC) and Decrement (DEC) are shown in black, figure 7. Pressing two buttons simultaneously causes enter (ENT) or escape (ESC) actions, figure 8. If no buttons are pressed for a minute or more, the device assumes run-time mode. The LCD shows the

Burns Connection Head Models #, # & # Figure 7 Switch Location Front 8.8.8.8 temperature (if the input is in range) or shows - - - - or - - - - to indicate over/under range. In order to access menu configuration mode, the user must press enter (figure 8) followed immediately by cycle (figure 7). In order to exit the menu and return to run-time, a user must press escape (figure 8). Back Decrement (DEC) -Menu When cycling around menu, the title (e.g. TYPE, UNIT etc.) is displayed for a second, then the menu entry is displayed ready for editing. See figure 9 below for RTD menu details and Figure 10 for Thermocouple details. Then use INC/DEC to move through the entries in a list, or to edit a real number. Decrement (DEC) Front 8.8.8.8 Figure 8 Enter and Escape Schematic Enter Decrement (DEC) Back TYPE P100 N10 USER Choose T/C type. UNIT DEGC DEGF Choose temperature units Figure 9 RTD Menu Schematic OFST After the input processing stage where electrical input has been linearized to procuce a temperature, the temperature is offset by the number entered here. DECP 8888. 888.8 8.888 Choose the position of the decimal point in PASS If non-zero, the user will be prompted for this number in order to enter the menu from TOUT 60 HOUR The device will return from menu mode to run-timeif no button is pressed for the time selected here. Front Escape Back 8.8.8.8 TYPE UNIT Figure 10 Thermocouple Menu Schematic OFST DECP PASS TOUT CA J T R S E L N B DEGC DEGF Choose temperature units After the input processing stage where electrical input has been linearized to procuce a temperature, the temperature is offset by the number entered here. 8888. 888.8 8.888 Choose the position of the decimal point in If non-zero, the user will be prompted for this number in order to enter the menu from 60 HOUR The device will return from menu mode to run-timeif no button is pressed for the time selected here. Choose T/C type. www.burnsengineering.com

Burns Connection Head Models #, # & # Maintenance Apart from configuration this equipment requires no maintenance. Any cleaning of the instrument should be carried out using a mild detergent and soft cloth. No solvents or abrasive cleaner should be used. If re-calibration is required please contact Burns Engineering for assistance (800-8-871). Repair and Warranty Service Repair and warranty service is available directly from Burns Engineering. Note: Failure analysis is an important part of product improvement. If you have a failure even if out of warranty, please contact us. We will do our best to help you. When returning goods, first call toll free 1-800-8-871 and obtain an RMA number. Always include a letter of transmittal and the RMA number with the shipment. Providing the following information in the letter will expedite service. Type of service and length of time the part has been in service. Description of the problem, and circumstances of the failure. Name and telephone number of the person who can answer questions about the returned part. Complete shipping instructions for return delivery. Request for warranty service if appropriate. For more information please contact us at: Burns Engineering Inc. 1001 Bren Road East Minnetonka, Minnesota 1-800-8-871 6 1-800-8-871