Metrohm 7A501 EXTRA SAFE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Similar documents
IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Gases and vapours classification

Replacement Tubes for Gillian Gas Detection Pumps

FILTRATION SYSTEMS CARBOX PHARMACEUTICAL HOODS ACTIVATED CHARCOAL FILTERS

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Digital Low Resistance Ohm Meter

Non-contractual document. Any reproduction, in whole or in part, by whatsoever process, is only permitted with Gazdetect approval.

Colorimetric Gas Detector Tube System US Dollar Price List

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Chemical Resistance Chart

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

Paramount Chemical Guide

I I e k ill L ill. INDUSTRIAL DIGITAL EARTH LEAKAGE CIRCUIT BREAKER and 3 PHASE ROTATION TESTER BESANTEK BST-ELC01 INSTRUCTION MANUAL

Physical properties of PET resins. 1. Intrinsic Viscosity (IV)

TANK LINING RESISTANCE GUIDE I-19

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

HSNO Class Flammable Liquids

MISSING INFORMATION ON APPARATUS GROUPS IN COLUMN i OF CHAPTER 17 OF THE IBC CODE

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

FR PVC COATED RAINWEAR

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Synonym(s) ) Chlorine, liquefied/gas. Ammonia, Gasoline, natural 7300 (gasoline) Hydrogen gas. Phosgene

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

TRIPLETT. Model 310 Type C Type 9

Table C 15. TAC Emissions Summary and Ambient Air Impact Concentrations. FCA Mack Avenue Assembly Plant Update February 2019

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart

Fans for ATEX EXPLOSIVE ATMOSPHERES

Selection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o

OPERATING INSTRUCTION

Installation, Operation & Maintenance of the In-Line Flame Arrestor Model L76L-UF

Professional Chemical Analyzer Service / BigDipper TechnoChem Institute, Beijing China. Hand held Single Gas Analyzer H-BD5gas

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

ANALYTICAL RESULTS. PWS ID/Name: ROCKHOUSE MOUNTAIN - CONWAY Report Date: 03/29/2016

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

CERTIFICATE OF ACCREDITATION

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Brushwood-chulha Average (SD) Mixed-chulha Average (SD) Dung-angithi Average (SD) SOAP koh (x ) (cm 3 molec -1 s -1 )

Small on price, big on boot

Installation, Operation & Maintenance. Model 7678 End of Line Deflagration Flame Arrester ATEX Certified

FCI GF SERIES. FCI GF Series. Versatile High Performance Mass Flow Meter for Gas Applications

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

HIGH VOLTAGE PROVING UNIT

TRIPLETT. Series. Type 3. Railroad Test Sets Instruction Manual /07

MasterProtect 1870 / 1880

Issue One. Chemical Compatibility Guide

Filtration efficiency: 99% or more

Learning Guide for Chapter 4 - Alkanes

EXPLOSION-PROOF MOTORS SINGLE PHASE

High pressure industrial ball valves

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

1.Safe testing IMPORTANT:

Halogen Free, Flame-retardant Polyether based TPU

Instruction Manual. Model 310 Digital Milli-Ohm Meter

Filtration efficiency: 99% or more HEPO2element

Information. Mechanical. Electrical. Chemical. Conversions & Calculations

HIGH VOLTAGE PROXIMITY DETECTOR

Installation, Operation & Maintenance. Model 7688 In Line Deflagration Flame Arrester. ATEX Certified

EN WORKMASTER HAZMAX BOOTS. Certification

Diffusion Results for Rigid Porous Polyethylene Samplers

Angle Grinder Holder

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

This manual covers the following model:

INSTALLATION & OPERATION MANUAL

Emissions Contaminant Totals Report

KEWTECH. KT56 digital multi function tester. Instruction manual

APOVAC R Vacuum Systems

Beverage Grade Carbon Dioxide

Impact of Petroleum Pricing. Raw Material Market Dynamics for Metal Coatings

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

RV-10 Center Arm Rest Console

EX Series User Manual

TEST REPORT: CHM12-01-LSM

Gaseous fuel, production of H 2. Diesel fuel, furnace fuel, cracking

HD and HDL Single-Stage Non-Lube Gas Compressors

VOC Chek 575 Series Selection Guide ppm-level Sampling of Organic Vapors

INSTALLATION & OPERATION MANUAL

VTC1000 Series Voltage Converter. Installation & Operation Manual

Texas Commission on Environmental Quality

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS

INSTALLATION & OPERATION MANUAL

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

VentureClad Insulation Jacketing Tapes 1577 Series

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Please contact your Project Manager if you have any questions or concerns pertaining to this report. Report Authorization Date 24-APR-2016

60 Watt Industrial LED Low Bay Light

Operator s Safety and Service Manual

Air-Operated Waste Oil Drainer

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

MANUAL PCE-IT111

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

GCEP. C. T. Bowman, R. K. Hanson, H. Pitsch, D. M. Golden Department of Mechanical Engineering. R. Malhotra SRI International

Azbil Corporation All Rights Reserved.

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

Transcription:

Metrohm Martindale Electric Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk 7A501 EXTRA SAFE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL CMR0011 ISSUE 10 01/04

.

LIMITED WARRANTY Martindale Electric Company Ltd warrants instruments and test equipment manufactured by them to be free from defective material or factory workmanship and agree to repair or replace such products which, under normal use and service, disclose the defect to be the fault of our manufacturing, with no charge for parts and service. If we are unable to repair or replace the product, we will make a refund of the purchase price. Consult the Instruction Manual for instructions regarding the proper use and servicing of instruments and test equipment. Our obligation under this warranty is limited to repairing, replacing or making refund of any instrument or test equipment which proves to be defective within twenty four months from the date of original purchase. This warranty does not apply to any of our products which have been repaired or altered by unauthorised persons in any way so as, in our sole judgement, to injure their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence, accident or which have had the serial numbers altered, defaced or removed. Accessories, not of our manufacture used with this product, are not covered by this warranty. To register a claim under the provisions of this warranty, return the instrument or test equipment to. Martindale Electric Company Ltd, Metrohn House, Penfold Trading Estate, Imperial Way, Watford. Upon our receipt and inspection of the product we will advise you as to the disposition of your claim. ALL WARRANTIES IMPLIED BY LAW ARE HEREBY LIMITED TO A PERIOD OF TWENTY FOUR MONTHS, AND THE PROVISIONS OF THE WARRANTY ARE EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED. The purchaser agrees to assume all liability for any damages and bodily injury which may result from the use or misuse of the product by the purchaser, his employees, or others, and the remedies provided for in this warranty are expressly in lieu of any other liability Martindale Electric Company Ltd may have, including incidental or consequential damages. TABLE OF CONTENTS SAFETY RULES GENERAL DESCRIPTION 7A501 OPERATING INSTRUCTIONS 7A501 SPECIFICATION SPARES AND ACCESSORIES REPAIRS TABLE 1 LIMITED WARRANTY PAGE 2-4 5 6-7 8-9 9 9 10-11 12

SAFETY RULES WARNING DISCONNECT TEST LEADS BEFORE OPENING TESTER. This tester has been designed with your safety in mind. However, no design can completely protect against incorrect use. Electrical circuits can be dangerous and/or lethal when lack of caution or poor safety practices are used. When using this tester to monitor high voltages turn off the power before connecting the tester. Where possible, do not touch the tester or its leads when the power is on. Turn off the power before disconnecting the tester. READ THE MANUAL Read this Instruction Manual carefully and completely. Voltages within the capability of this tester can be hazardous. Follow the instructions in this manual for every measurement. Read and understand the general instructions before attempting to use this tester. CLASS 2c (cont.) (ii) Compounds containing oxygen Oxides (including ethers) carbon monoxide methoxyethanol ethoxyethanol ethyldigol butyldigol dibutyl ether (iii) Compounds Containing Halogens Compounds without oxygen chloromethane chloroethane bromoethane chloropropane chlorobutane bromobutane dichloroethane dichloropropane chlorobenzene benzyl chloride dichlorobenzene allyl chloride dichloroethylene chloroethylene Compounds with oxygen acetyl chloride chloroethanol chlordimethyl ether Acids acetic acid -2- -11- CLASS GAS OR VAPOUR Esters methyl formate ethyl formate methyl acetate ethyl acetate butyl acetate amyl acetate methyl acetoacetate diethyl oxalate methyl acrylate ethyl acrylate (iv) Compounds Containing Nitrogen Amines methylamine dimethylamine trimethylamine diethylamine triethylamine propylamine butylamine cyclohexylamine ethanolamine diethylaminoethanol diaminoethane aniline dimethylaniline amphetamine toluidine pyridine Amides formdimethylamide Nitro-compounds nitromethane nitroethane nitrobenzene (v) Compounds Containing Sulphar ethyl mercaptan diethyl sulphate

CLASS 1 2a 2c Methane (firedamp) Ammonia (i) Hydrocarbons Alkane methane*(industrial) ethane propane butane pentane hexane heptane nonane cyclobutane cyclohexane methylcyclohexane decahydronaphthalene CLASS GAS OR VAPOUR Alcohols and Phenols methanol ethanol propanol butanol pentanol hexanol octanol nonanol cyclohexanol methylcyclohexanol diacetone alcohol phenol cresol SAFETY CHECK Double check the switch setting and lead connections before making measurements. Are you following instructions? When changing the battery or removing the cover to access the internal circuitry, always disconnect the test leads. DON T TOUCH Don t touch exposed wiring, connections or other live parts of an electrical circuit. If in doubt, check the circuit first for voltage before touching it. Turn off the power to a circuit before connecting test probes to it. Be sure there is no voltage present before you touch the circuit. Do not use cracked or broken test leads. Benzenoid benzene toluene xylene ethylbenzene trimethyibenzene aphthalene Alkene butene cyclohexene styrene di-isobutylene Mixed Hydrocarbons turpentine coal tar naphtha petroleum naphtha kerosene Aldehydes formaldehyde acetaldehyde octaldehyde paraformaldehyde paraldehyden metaldehyde benzaldehyde butyraldehyde Ketones acetone ethyl methyl ketone propyl methyl ketone butyl methyl ketone amyl methyl ketone acetylacetone cyclohexanone HIGH VOLTAGE IS DANGEROUS Always start with the power turned off. Be sure these is no voltage present before making connections to the circuit. Before disconnecting the tester, turn the circuit off and wait for the meter to return to zero. HAZARDOUS LOCATIONS In hazardous locations where inflammable gases may be present, it is important to remember certain precautions must be taken These are: 1 DO NOT FLICK THE TEST LEADS 2 CONNECT TEST LEADS SECURELY TO CIRCUIT UNDER TEST 3 RELEASE OPERATING BUTTON BEFORE DISCONNECTING TEST LEADS -10- -3-

NOTE: BS1259 is now obsolescent and has been superseded by BS5501. Under BS1259 the tester by itself was approved whereas under BS5501 approvals also consider applications of the tester. For example when carrying out insulation testing at 500V DC on wiring installations the inherent self-capacitance of the wiring will charge up and could create an incendive spark if discharged accidentally. It is necessary therefore to have a good working code of practice so that this hazard is eliminated and to ensure that the charge held in the wiring capacitance is discharged safely via the tester at the end of each insulation test. (C) ENVIRONMENTAL Operating Temperature: 0 to 40ºC Storage Temperature: -20ºC to 60ºC SPARES AND ACCESSORIES (7A501) Leads: METDFK0113 Carry Case: 7A501 METPA24249A Battery: 1.5V IEC R6B CEJ0035 THIS INSTRUMENT SHOULD ONLY BE USED BY A COMPETENT, SUITABLY TRAINED PERSON. REMEMBER: SAFETY IS NO ACCIDENT REPAIRS Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford WD24 4YY T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk -4- -9-

7A501 SPECIFICATION (A) ELECTRICAL Insulation MΩ Range: 0-50MΩ Test Voltage: 500V DC±10% across 1MΩ Short Circuit Current: <2mA Accuracy: ±1.6mm of scale arc length Continuity Ω Range: 0-50Ω Test Voltage: Nominal 200mV Short Circuit Current: <26mA Accuracy : ±1.6mm of scale arc length GENERAL DESCRIPTION The 7A501 has been approved to BS1259 (1958) and carries the Ministry of Power Certificate Number IS1428 (Class 1)and the Factory Inspectorate Certificate Number 2148 (Class 2A and 2C) which covers Methane, Ammonia and Hydrocarbons. Table 1 gives a full list of gases and vapours that are covered. The testers have an analogue display and 500V DC insulation test voltage with a short circuit current of less than 2mA. On continuity the test voltage is nominally 200mV with a short circuit current of 26mA maximum. A special allen key is required to access the batteries so that they may not be changed in a hazardous area. This tester does not comply with The ATEX directive. Battery: 6 off 1.5V AA IEC R6B EMC: Meets BS EN 50081-1 BS EN 50082-1 (B) MECHANICAL Size: 132 X 82 X 60mm Material: ABS Weight: 0.6kg Movement: Nominal1.0mA sensitivity - taut band Scale Length: 70mm Test Leads: 914mm long with crocodile clips -8- -5-

7A501 OPERATING INSTRUCTIONS ZERO ADJUST If the pointer does not coincide with the zero on the left side of the scale, adjust as required with a screwdriver inserted through the hole in the back of the case. BATTERY TEST Connect the test terminals together with the test leads and operate the right (MΩ) side of the test switch. The pointer should read zero on the top MΩ scale. If not replace the batteries. BATTERY REPLACEMENT Fig. 1 Front Layout of 7A501 The test switch is operated with a rocker button so that depressing and holding the left side measures continuity and depressing and holding the right side measures insulation. Readings are displayed on an analogue meter. If the pointer deflects upscale when the test leads are connected to a circuit it indicates that the circuit is live and operating the test switch could result in damage to the tester. Disconnect the leads from the circuit. Before using the tester check the pointer zero and the battery condition. The batteries must never be replaced in a hazardous area. The carry case must first be removed by unscrewing the allen screw (with the special key provided) in the retaining strap. To access the batteries remove the battery lid by undoing the screw at the rear of the tester with the special key. Remove the spent batteries, insert new ones and reassemble. CONTINUITY 0-50Ω. Continuity resistance is displayed on the meter when the left side (Ω) of the test switch is operated. INSULATION 0-50MΩ. Insulation resistance is displayed on the meter when the right side (MΩ) of the test switch is operated. -6- -7-