BARTON 7000 Series Liquid Turbine Meters

Similar documents
7000 Series Liquid Turbine Meters

Liquid Turbine Flowmeters

Liquid Turbine Flowmeters

BARTON 7400 Precision Gas Turbine Flow Meters

JISKOOT Bunker Blending

Liquid Turbine Flowmeters

Liquid Turbine Flow Meters

Gas Turbine Flowmeters Robust performance and maximized availability across a range of applications

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

High Performance Turbine Technology

Flow Sensors & Instruments

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

Liquid Turbine Flowmeter

PA - Turbine Flowmeter Range

Thermostatic Control Valve

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

Thermostatic Control Valve

Technical Data. BiRotor Plus Positive Displacement Meter

Turbine Flow Meter. Model User Manual. TRB-UM EN-03 (December 2015)

Pilot-Operated Safety Relief Valves

Model 788DVC DIGITAL CONTROL VALVES

Turbine Flow Meter. B16N Series FloClean Tri-Clover End Fitting. User Manual. TRB-UM EN-01 (December 2016)

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

Thermostatic Control Valve

RUN ACCUM. TOTAL STOP BAT LOW HIGH

A Cameron Company. Barton. Flotrac. /Floco. Meters, Samplers & Pulse Transmitters.

WHEATLEY Series 500. Fire-Tested Carbon Steel Flanged-End Check Valves

G2 Industrial Grade Meters

Thermostatic Control Valves

Data Sheet P4055 Pressure Transducer

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Turbine Flow Meter Range

Technical Datasheet. HM AC Series. Turbine Flow Meters. for High Pressure Applications up to 1,400 bar

HTM Series Helical Turbine Meters

Design and application

Liquid Controls. Turbine Meters for Custody Transfer Flow Measurement of Petroleum Products. Loading Terminal, Offshore, and Pipeline Applications

CBA-Series Pneumatic Dimension Data Metric

Turbine flowmeters Series TM

Model E. Thermostatic Control Valves. Typical applications

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY

Turbine Meters & Accessories

Transmitting Transducer. Gas/Air Velocity Range:

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

FT Series. Turbine Flowmeters. Description. Features. Applications. Operation. FT Series Turbine Flowmeters

Vane Pumps for Corrosive, Thin Liquids at Higher Pressures

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

Hoffer Engineering Guide for Liquids

Product Data Sheet DESCRIPTION

A1 Commercial Grade Meters

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

1900 Series Universal Media. Best Under Pressure Series. Universal Media Pressure Relief Valve

TYPE 5611/5611Q Elastomer Bellows Seals. ! Temperature: ! Pressure: 28 bar g/400 psig. ! Speed: ! End Play/Axial Float Allowance: 0.13mm/0.

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

G2 SERIES INDUSTRIAL GRADE METERS

Product Data Sheet DESCRIPTION

3-Way Temperature Control Valve

Micro Motion ELITE Mass Flow and Density Meters

M1/M2 POCKET FEEDER. Compact design DESIGN FEATURES. Special ball and seat design. Large ball pocket capacity. Automatic cycling

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Technical Datasheet. HM U Series. Turbine Flow Meters. for lubricating liquids

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

PSF50 Paddle flow switch

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

TURBINE FLOW METER SELECTION GUIDE

3-Way Temperature Control Valve

TYPE 2100 ELASTOMER BELLOWS UNITIZED SEAL Technical Specification

Daniel Liquid Turbine Flow Meter Technical Guide

Bettis GH-Series Pneumatic Spring-Return Actuator Torque Chart Imperial

Quantum LMV. Low and Medium Voltage AC Induction Totally Enclosed Fan Cooled Motors. GE Power Conversion

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

VLM20 In-line Vortex Flowmeter

Shafer RV-Series Rotary Vane Valve Actuators Valve Operating Systems for Critical Pipeline Applications

Micro Motion 7827 Digital Viscosity Meter

Micro Motion F-Series Coriolis Flow and Density Meters

Daniel Measurement & Control - Product Training Calendar

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Dynamic Lifter * Canada United States Malaysia UAE. Pressure Relief and Surge Anticipation Valve. Reliable and Proven Technology Since 2002

Micro Motion ELITE Mass Flow and Density Meters

RCM. Direct Reading Flowmeter. for Liquids or Gases

EZ-IN Series Turbine Flowmeter

Field IT Electro-Magnetic Flowmeters Sensors

PRECISION METERS. Tel: / Int'l: Fax: / Int'l: Springer Pumps, LLC Telford, PA 18969

Data Sheet P6000 Remote Mount Miniature Pressure Sensor

Distributed Valves VALVES & MEASUREMENT

Vane Pumps for Corrosive, Thin Liquids at Higher Pressures

Magnetic-inductive flow meter for hazardous areas

KDM ARMORED FLOW METER & SWITCH

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Micro Motion Model D and DL Coriolis Flow and Density Meters

Jamesbury High-Performance Actuators. Maximizing cycle life. Lowering Costs.

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

METAL BELLOWS CARTRIDGE SEAL. Operating Conditions

BARTON Floco/Flotrac Meters, Floco Samplers and Pulse Transmitters

fact sheet Masoneilan * 8007/8008 Series Electro-pneumatic Transducers GE Energy Nozzle Design Reducing Effects of Vibration Overview

Product Data Sheet. Turbine Flow Meter. B16D Series FloClean Sanitary DESCRIPTION INSTALLATION REPAIR KITS

fact sheet Masoneilan * 8012/8013 Series Electro-pneumatic Valve Positioners GE Oil & Gas Excellent Dynamic Response and Positioning Accuracy

Transcription:

TECHNICAL SPECIFICATIONS BARTON 7000 Series Liquid Turbine Meters Cameron s BARTON 7000 series turbine meters are designed for a broad range of precise liquid measurement applications. Based on more than 0 years of turbine manufacturing eperience, this built-to-order series features a range of sizes, materials, bearing systems, and options. Features Linearity (BARTON Models 7100 and 700) ± 1% of reading over flow range for meters smaller than 1-in. ± 0.5% of reading over flow range for meters 1 in. and larger ± 0.5% of reading over limited ranges (contact factory for details) Linearity (BARTON Model 7300) ± 0.5% of reading over flow range ± 0.15% of reading over limited ranges (contact factory for details) Repeatability ± 0.0% of reading Symmetrical bi-directional design Ideal for reverse flow applications, where flow capacities are the same in either direction. Electronic options provide instantaneous flow direction sensing. High quality bearings Model 7100/7300 meters come standard with wear-resistant tungsten carbide sleeve bearings, and model 700 meters are designed with self-lubricating, precision stainless steel bearings with dry lubricant impregnated ball separators.

Performance The average K-factor for each turbine is determined by using water as the test media. Standard testing is performed with eight flow rates evenly distributed across the flow range and two repeatability points. Meter linearity indicates that no data point will eceed the average of all the data points within the linear meter capacity. To ensure accurate operation, the turbine meter should be installed in a straight length of pipe of the same diameter as the turbine meter, etending at least 10 diameters upstream and five diameters downstream. Accessories Cameron offers a broad range of accessories and companion electronics for use with the BARTON 7000 series turbine meter, including: Meter runs Pre-amplifiers Totalizers Flow computers Connectors and cables Companion electronics can be supplied to meet eplosion-proof or intrinsic safety requirements. Contact your local Cameron sales representative for more information. Model Selection Criteria Use the following table to determine the correct model for a liquid application. For assistance with meter sizing for your application, contact your Cameron sales representative. Meter Fluid Requirements Model 7100 Model 700 Model 7300 (High-Res Ouput) Hydrocarbon measurement Liquids with specific gravity < 0.5 Liquids with viscosity < 0.5 cp Other liquids Process piping and fluids (free or solids) Solids likely in process piping and/or fluids Meter sizes 3/8 in. to 8 in. 3/8 in. to 3 in. in. to 1 in. Bearing type Tungsten carbide sleeve bearings 0C stainless ball bearings Tungsten carbide sleeve bearings

7100 Model Selection Model Flow Range Linear Range (water) Meter Output Nominal Minimum Maimum Nominal Nominal Maimum in. mm US GPM m 3 /hr US GPM m 3 /hr Pulses/gal. Pulses 1000/m 3 Frequency (Hz) 7183 3/8 10.5 0.10 0.9 19,000 500 170 718 1/ 15 0.88 0.0 8. 1.8 13,00 350 1790 7185 5/8 18 1. 0.3 1 3.3 7700 03 050 718 3/ 0.3 0.5 3 5. 3380 893 1300 7101 1 5 5.0 1.1 50 11. 130 35 1117 715 1-1/ 3 10.8 80 18. 30 1 80 71 1-1/ 0 13 3.0 130 9.5 05 107 878 710 50 5.5 0 5.5 0 3. 90 715-1/ 5 10 0 100 115 30. 85 7103 3 80 70 15.9 700 159 7 0.1 890 710 100 105 150 8 3 8.5 70 710 150 50 57 500 57.8 8.8.3 370 7108 8 00 50 1. 500 1 3. 0.95 3 700 Model Selection Model Flow Range Linear Range (water) Meter Output Nominal Minimum Maimum Nominal Nominal Maimum in. mm US GPM m 3 /hr US GPM m 3 /hr Pulses/gal. Pulses 1000/m 3 Frequency (Hz) 783 3/8 10 0.5 0.11 5 1.1 15,500 095 191 78 1/ 15 1.0 0.3 10.7 10,500 77 1750 785 5/8 18 1. 0.3 1 3.5 00 191 170 78 3/ 0.3 0.5 3 5. 700 713 1035 701 1 5 5.0 1.1 50 11. 1100 91 90 75 1-1/ 3.0 1. 90 0. 510 135 75 7 1-1/ 0 13 3.0 130 9.5 30 8.5 93 70 50 5.5 0 5.5 190 50. 70 703 3 80 58 13 580 13 59 15. 570 7300 Model Selection Model Flow Range Linear Range (water) Meter Output Nominal Minimum Maimum Nominal Nominal Maimum in. mm US GPM m 3 /hr US GPM m 3 /hr Pulses/gal. Pulses 1000/m 3 Frequency (Hz) 730 100 115 1150 0 17. 15 730 150 50 57 50 511.9 975 7308 8 00 50 13 500 1 15 1350 7310 10 50 800 18 8000 1817 7.8.1 100 731 1 300 150 8 1500 838 5.7 1.5 1190 3

7100/700 Pressure Drop 10 8 Nominal in. (mm) 3/8 (10) 1/ (15) 5/8 (18) 3/ (0) 1 (5) 1-1/ (0) (50) 3 (80) (100) (150) 8 (00) Gross Pressure Drop - PSID 1.0 0.8 0. 0. 0. 0.1 0.08 0.0 0.0 0.01 0.1 8 8 1.0 10 8 100 8 1000 Flow Rate - US gallons/min based on water at 0 F (1 C) 8 10,000 8 100,000 0.03 0.7.7.7 7 71,71 Flow Rate - M 3 /hr based on water at 0 F (1 C)

7300 Pressure Drop 10 8 Nominal in. (mm) (100) (150) 8 (00) 10 (50) 1 (300) Gross Pressure Drop - PSID 1.0 0.8 0. 0. 0. 0.1 0.08 0.0 0.0 0.01 30,300 3,000,30,000 Flow Rate - US gallons/hr based on 0.8 SG oil @ 1.0 cst 1 10 100 1,000 Flow Rate - M 3 /hr based on 0.8 SG oil @ 1.0 cst 5

Specifications Compliances Pressure Rating CSA certified for hazardous areas, Class I, Division I, Group B, C, D; Class II, E, F, G; Class III, NEMA waterproof to NEC (USA) and CEC (Canadian) standards. ATEX certified, EE d IIC Compliant with ANSI 1.7.01-003 single seal requirements Available with CE mark for Pressure Equipment Directive (PED, 97/3/CE). Threaded Meters Connection Size (in.) psi bar mpa < 1 5000 35 3.5 1 00 303 30.3 1-1/ 000 7 7. 1-1/ 300 0.1 50 183 18.3 Flanged Meters Flanged meter pressure ratings are based on ASME B1.5, DIN, or BS10 as applicable. End Connections Flanged ASME B1.5 (BS EN 1759), DIN (BS EN 109), BS10 Conduit Connections (Magnetic Pickup) Threaded Standard: NPT; Others available on request 3/ MNPT (coil boss) 1 standard Additional coil boss available for meters 1 and above Materials Rotor Blades 1 Model 7100/700 30 stainless steel Model 7300 Shrouded 31 stainless steel with nickel bars Bearings Model 7100/7300 Tungsten carbide (sleeve type) Body Flanges 1 Internals 1 Model 700 31 stainless steel 31 stainless steel Temperature Range Model 7100/7300-0 F to 300 F (-9 C to 18 C), standard -0 F to 50 F (-9 C to 3 C), optional Model 700-0 F to 50 F (-9 C to 3 C), standard Pressure Drop Model 7100/700 See pressure drop curve on page. Model 7300 See pressure drop curve on page 5. 0C stainless steel, self-lubricating (ball type) Linearity Model 7100/700 ± 1% of reading over flow range of fractional size meters ± 0.5% of reading over flow range of meters 1 size and above ± 0.5% of reading over limited ranges (contact factory) Model 7300 Repeatability All Models ± 0.0 of reading Output Type Sine wave Voltage Frequency 1 Other materials are available on request. ± 0.5% of reading over flow range of meters size and above ± 0.15% of reading over limited ranges (contact factory) Varies with meter size and flow rate (typically 0 mv to 5 V, peak-to-peak) Proportional to flow Observe the temperature rating of companion electronics where applicable. Use remote mount electronics with etensions to avoid temperature etremes. For information regarding higher temperature ratings, contact your Cameron sales representative.

Dimensions Flanged Meters Coil Boss 3/ MNPT Turbine Meter A (Face-to-Face) Connector Electrical (customer supplied) Pickup Coil 1 nom. Flanged Meter Face-to-Face Dimensions (Dim. A) Up to 00 ASME 900 and 1500 ASME 500 ASME Models in. mm in. mm in. mm 7183, 783 5 17 7 178 7 178 718, 78 5 17 7 178 7 178 7185, 785 5.5 10 7 178 7 178 718, 78 5.5 10 7 178 7 178 7101, 701 5.5 10 8 03 8 03 715, 75 15 8 03 8 03 71, 7 15 9 9 9 9 710, 70.5 15 9 9 9 9 715, 75 7 178 10 5 10 5 7103, 703 10 5 10 5 11 79 710, 730 1 305 1 305 1 305 710, 730 1 35 1 35 7108, 7308 1 0 7310 0 508 731 10 Threaded Meters Threaded Meter Dimensions B (diameter) A (End-to-End) Pickup Coil Models Thread (NPT) End to End (Dim. A) Diameter (Dim. B) in. mm in. mm 7183, 783 3/8.75 70 1.15 8. 718, 78 1/.75 70 1.15 8. 7185, 785 3/.75 70 1.5 3 718, 78 3/ 3.5 83 1. 3. 7101, 701 1 3.5 89 1.9.9 715, 75 1-1/ 3.88 99.38 0.5 71, 7 1-1/.38 111.50 3.5 710, 70.75 11 3.00 7. 7

NORTH AND SOUTH AMERICA 150 JFK Blvd. Houston, TX 7703 USA Tel 1 81 58 9500 ms-us@c-a-m.com EUROPE, AFRICA, CASPIAN, AND RUSSIA 3 Steyning Way Southern Cross Trading Estate Bognor Regis West Susse PO 9TT England, UK Tel 13 871 ms-uk@c-a-m.com ASIA PACIFIC Suite 1.0 Menara AmFirst No. 1 Jalan 19/3 300 Petaling Jaya Selangor Darul Ehsan Malaysia Tel 03 795 015 ms-kl@c-a-m.com MIDDLE EAST, NORTH AFRICA Plot #S1008 South Zone P.O. Bo 3011 Jebel Ali Dubai, UAE Tel 971 80 7700 ms-me@c-a-m.com USA CANADA UK CHINA UAE ALGERIA MALAYSIA INDIA RUSSIA www.c-a-m.com/measurement 01 Cameron BARTON is a registered trademark of Cameron. SWP M 1/15 AD0090M