SITE /ROADWAY WARP9. The first outdoor luminaire designed not to be seen, using Visual Stealth Technology. TM

Similar documents
WP9LM. Specifications. WARP9 - Large, magnetic revision 10/20/16 kl_wp9lm_spec.pdf. Type: Job: Catalog number: Approvals: Date: Page: 1 of 5

Options. Pole and Arm. Suitable for wet locations

SITE /ROADWAY BNS SERIES. Bounce. Pedestrian Scale Luminaire W H.I.D.

1SA / ALT3P35/ 120L5K277/ WH/ A26

CC/CCS21 21" Post Top Mounted, Curvilinear, LED revision 5/9/11 kim_cc21pled_spec.pdf

TORNADOTM BOLLARD PATENTS PENDING

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

SITE /ROADWAY. Lantern. Era. Performance with Heritage Styling Watt, Integral Ballast


C A M B E RTM PATENTS PENDING

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

AFL FLOODLIGHT SERIES

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

Laredo Decorative Wallpack Family

NeoSphere CLASSIC SPHERICAL LUMINAIRE

ORDERING INFORMATION: 120 Volts (120)

Perimaliter Wallpacks

Laredo - Decorative Wallpack Family

KAD250MR3TBSPD04 Wall Fixture

Overall Dimensions. Specifications

V-Bollard Architectural LED Luminaire / Bollard

Series Optics Mounting Lamping Finish Voltage. H039T6 1 39wT6 H w. H w. (T6 only available with MA and MS refractors) 12 3 /8" (314mm)

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

V-Bollard Architectural LED Luminaire / Bollard

Bavaria Downs. Chaska, MN. Lighting

Perimaliter Wallpacks

H700 H710 H720. Compact Flood. Typical Applications. Features. Lamp Types. Approvals SPECIALTY LANDSCAPE

Version 2.1. The Next Generation of Outdoor Lighting Advancements in LED Technology. KIM LIGHTING 1Lenis eumsan esent lutat lam

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

AEROSYSTEM POLE AND BRACKET SPECIFICATIONS NO PAIN, ALL GAIN ORDERING CHART FINISHES. by LSI Courtsider Sports Lighting. Installation As Easy As 1 2 3

Lumark PFPRV PREVAIL POLE AND FIXTURE COMBO

Lumark PFPRV PREVAIL POLE AND FIXTURE COMBO

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

PATHWAY LIGHTING 3100 SERIES LOUVERED BOLLARD

The PREMIER TM. II Series

APPENDIX B: LISTS OF APPROVED MATERIALS

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA

Meridian DETAILS CA10T4A CA10T4D CA13T4A. IP66 EPA: 2.2 FT 2 Weight: 27 lbs - 12 kg

Overall Dimensions. Specifications

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

Campana DETAILS CN55P1A. IP67 EPA: 1.8 FT 2 Weight: 52 lbs - 24 kg CN55P1B

Paseo. Luminaire CE21T4UF Pole PA40 base cover BD11

Qty: L50 50W. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45 PM6 60.

Project: Type: Qty: Height Lamping Finish Voltage Options. Series MTRQ /8" (1252mm) /16" (551mm) Options

Morino DETAILS IP67. Contact factory for WIRELESS CONTROLS and further details REV. 5: 06/18. EPA: 1.8 FT 2 Weight: 35 lbs - 16 kg

OP2 CosmoPolis Series

3900 BOLLARD SERIES.

Dual Lamp Ceramic Metal Halide 3 Lumen Packages in 1 Luminaire

25 Sign / Wall Lighter 4324 LED Series Extruded Aluminum, PicoPrism LED revision 9/9/15 kl_4324led_series_spec.pdf

LytePro. A Family of Architectural LED Luminaires. Solid State, Solid Solutions. Stonco is a Philips company

Levanto DETAILS. IP67 EPA: 0.96 FT 2 Weight: 35 lbs - 16 kg

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

Applications. Standard Materials

BOW SX - LED Luminaire

CALLISTO SERIES. Product Overview and Technical information>>

DECORATIVE. Tear Drop Series

Park Avenue DETAILS. IP67 EPA: 1.8 FT 2 Weight: 45 lbs - 20 kg

PGL350P W PS Wallpack

MVOLT

Evolve LED Roadway Lighting

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

GLEON GALLEON LED Light Squares

MetroVue HOLOPHANE THE

EAL Series. Effex Area Luminaire, W HID. Overall Dimensions. Specifications Approvals: Catalog Number: Date: Page 1 of 6

Domia DETAILS CY55P1A CY55T4 IP67

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Promenade TM Series LED PRMD

A Perfect Combination of Brilliance and Beauty

BDT Product Sales & Support (951) (800)

GE Evolve LED Area Lighting Scalable EASC High Lumen

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Symphony DETAILS. IP66 EPA: 1.8 FT 2 Weight: 52 lbs - 24 kg

PGA Parking Garage Luminaire

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

Qty: R4 Type IV Distribution. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45

Levanto. details CLE17T4A

FULL CUTOFF DARK SKY COMPLIANT FIXTURES. commercial & architectural lighting

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

Historia DETAILS CY25P1A CY25T4B (FGC/FGF) IP66 CY25P1A (M222/WPB)

TYPE APPROVALS. Diffused lens option Programmable occupancy sensor (dimming) SiteSync wireless controls 130+ lumens per watt

PG Series. Our PG Series has now been expanded to complete your entire site needs. With added housing shapes of round and square we offer

CD20S2 DENVER. Luminaire. Optics. Sources Lamp 4K = High power LED, 4000K (neutral white) ±150K.

Crosstour LED Wall Mount Luminaire

CN12P1A GCPO REV. 1: 12/16

Invue MSA MESA LED. 1-6 LightBARs

Industrial and Commercial Indoor Parking and Area Security Lighting Floodlighting Sports Lighting HID Controls

IN-GRADE LTV SERIES. Lightvault NO COMPROMISES NO EXCUSES NO EQUALS BRONZE AND COMPOSITE HOUSING

SpecificationS. LED Lighting Caged Acorns. Rated IP65

SITE/ROADWAY CC/CCS LED. Curvilinear LED. The Next Generation of LED Site Lighting

Evolve LED Area Lighting EALP

OSQ Series OSQ LED Area/Flood Luminaire Large

A r c h i t e c t u r a l A r e a L i g h t i n g

19.0" (482mm) Performance Summary 3.1" (79mm) NanoOptic Precision Delivery Grid optic Receptacle location (ordered as an option)

LUM SERIES-PLED w/ POLE RATED FOR 100MPH SHAFT

kenall dark sky luminaires

CALL TODAY!

Transcription:

SITE /ROADWAY WARP9 TM The first outdoor luminaire designed not to be seen, using Visual Stealth Technology. TM

TM THE FUTURE OF SITE/ROADWAY LIGHTING Kim s Theory of Relativity A Concealment Approach Low Visual Signature Technology Advanced Performance Features Optical Design Features Mechanical Features Installation & Maintenance Features Ordering Information Luminaire Specifications Lamp Guide 2 4 6 8 10 12 14 16 18 20 MAILING ADDRESS P.O. BOX 60080 CITY OF INDUSTRY, CA 91716-0080 BUSINESS ADDRESS 16555 EAST GALE AVENUE CITY OF INDUSTRY, CA 91745 PHONE: 626.968.5666 FAX: 626.369.2695 ENTIRE CONTENTS COPYRIGHT 2011 KIM LIGHTING INC. ALL RIGHTS RESERVED REPRODUCTION IN WHOLE OR IN PART WITHOUT PERMISSION IS STRICTLY PROHIBITED. U.S. PATENT D568,521 www.kimlighting.com Printed in U.S.A. 5508811200 Version 1.3 (7/19/11) Hubbell Lighting, Inc.

Fixture/Background photo Low Visual Signature Luminaire WARP9 is a new concept in luminaire design visual stealth. Typical site lighting attempts to embellish, decorate, or adorn, often beyond the original architectural intent. WARP9 was conceived and developed with an entirely different directive. WARP9 was designed to disappear from the site, camouflage itself within its surroundings, and avoid detection from daytime visual perception. WARP9 is the antithesis of massive, showy, recognizable, and ornamental design, allowing architecture to remain visually dominant as it was originally intended. WARP9 is a concept that is long overdue, yet one that is light years ahead of its time. KIM LIGHTING 1

Kim s Theory of Relativity The Complete Design Solution From Parking Lot to Building Proper Scale Coordinated Design Site/Roadway Zone Parking lots and roadways require luminaires on 20'-40' poles to efficiently light these large areas. Therefore, this lighting sets the design style for all other lighting zones as you progress towards the building. Select WARP9L large version luminaires with round poles for this zone. Pedestrian Zone As an observer leaves the parking lot and transitions to pedestrian areas, poles should decrease in height to 10' 16'. In addition, luminaires should decrease in scale, as human perception of proportion is keen at this level. Select WARP9 s small version luminaires for this zone, and select a finish that will integrate well with the fixture s primary background elements. 2 KIM LIGHTING

Landscape/Pathway Zone Near the building, luminaires should continue to disappear, blending into the landscape and hardscape elements. Select from a wide range of low voltage, line voltage, and LED landscape luminaires, or Kim Lighting s VRB and GEM bollard series to integrate with WARP9 s curvilinear form. Building/Perimeter Zone Avoid installing pole-mounted luminaires close to the building, as they tend to dominate the architecture. However, if required, WARP9 is the best solution to integrate with architectural proximity. Kim Lighting suggests WARP9 wall mounted luminaires to reduce daytime detection of building mounted equipment. KIM LIGHTING 3

A Concealment Approach WARP9 s efficient and low profile compound curve design results in a close synergy between aerodynamic performance, illumination performance, and its ability to limit cross section visibility. When installed with the right scale, finish and placement, WARP9 s sophisticated and complex camouflage scheme achieves a unique level of concealment and subtle presence never before offered in an architectural luminaire. Product Overview: Kim Lighting s WARP9 series offers a complete package of luminaire sizes and options to integrate seamlessly into any environment, natural or man-made. Choose from two housing sizes in electronic or magnetic ballasted versions, and select one of four distinct light distributions and a wide variety of mounting, fixture, and finish options to complete your WARP9 visual stealth concept. Four Housing Configurations WP9SE WP9LE WP9SM WP9LM Four Distinct Distributions TYPE II TYPE III TYPE IV TYPE V Sq Multiple Options Wall Mount Pole Mount SLX Lexan Lens 4 KIM LIGHTING Houseside Shield Tamper Resistant Latch New Stealth Gray TM Finish

WP9LE WP9LM WP9SE WP9SM KIM LIGHTING 5

Low Visual Signature Technology DESIGN LOGIC: The Disappearing Act Modern technology produced Kim Lighting s new WARP9 luminaires, but the camouflage principles behind it were learned instinctively from nature thousands of years ago. WARP9 s fundamental approach is the same as those used by wildlife and hunters for millennia: hide, blend, and deceive. There are two basic elements of camouflage: shape and color. WARP9 capitalizes on both of these principles in unique ways to reduce perceptual attraction and luminaire detection. First, WARP9 utilizes a computer generated low-profile compound curve design to create a natural compact top arc that reflects the sky from normal viewing angles. This breaks up the luminaire s outline, disrupting its silhouette and evening out its 3-dimensional surface, making it more difficult to see as one object. This reduces visual mass, and allows the viewer to envision the entire site without disruptive and massive luminaire shapes to draw attention away from architecture and landscape. Second, WARP9 utilizes a hollow mounting arm that gracefully blends with the housing, and minimizes its visual signature. Kim Lighting has also developed a unique color scheme to further reduce the luminaire s visual signature. VISUAL STEALTH TECHNOLOGY : New Stealth Gray Finish Color is essential to camouflage, as its similarity to the primary background will tend to break up that area of the outline and blend the shape away from normal detection. Over 100 painted samples were tested and reviewed to determine how well they matched the predominant colors of contemporary architecture, typical horizons, and northern hemisphere skies. These were then narrowed down to a few prototype samples that were field tested for visual acuity, perception attraction, and detection reduction. The result is Kim Lighting s new Stealth Gray finish option featuring a light gray hue suitable for any outdoor environment. However, designers can select from a wide variety of standard and custom finishes depending on application and immediate background surface coloration. 6 KIM LIGHTING

FPO AERODYNAMICS: Small Size Low EPA Specify Kim Lighting s new Stealth Gray finish to further reduce the fixture s visual signature. Featuring a light gray semi-gloss surface, Stealth Gray is a result of an extensive study of finishes and paints for typical application scenarios in natural or architectural environments. A welcomed result of WARP9 s thin design is a very low EPA rating, suitable for installation in almost any environment, including high wind, coastal, and hurricane prone locations. Kim Lighting recommends mounting WARP9 luminaires on round poles to further improve aerodynamics and lend to the fixture s camouflaged appearance. Round poles have less visual signature than square poles. WARP9 Small Housing and Arm EPA (WP9SE): 0.52 WARP9 Large Housing and Arm EPA (WP9LE): 0.95 Note: Pole selection and height will also determine final EPA allowance for your application. KIM LIGHTING 7

Advanced Performance Features High Performance Low Profile WARP9 s super low profile housing does not mean a compromise in illumination performance. In fact, an entire new series of reflector systems was specifically developed through a highly detailed computer study of efficiency and lamp output maximization. These new systems feature highly specular 95% reflective Alzak finishing, tooled and assembled by hand at Kim Lighting s California facilities to maintain the highest quality and performance standards. Choose from IES Type II, III, IV, and V Sq distributions, rotatable for any application or distribution requirement. Full Cutoff: StarView Compliant Kim Lighting's StarView products meet IES and IDA full cutoff requirements for use where light pollution or light trespass may be a concern, and to promote the enjoyment of celestial visibility at night. WARP9 utilizes a horizontal lamp orientation with a flat glass lens to produce full cutoff with zero light above 90 horizontal. Therefore, all WARP9 fixtures are StarView compliant and are approved for full cutoff applications in any jurisdiction. WARP9 also offers a house-side shield option where light trespass and control of spill light onto adjacent property may be a concern. WP9L = 5K" WP9S = 4B" 8 KIM LIGHTING

Four Distinct Light Distributions Site configuration determines the combination of light distributions required to efficiently illuminate desired areas. WARP9 is available in four highly efficient light patterns, combined with seven mounting arrangements and rotatable optics for incredible design versatility and flexibility. Contact Kim Lighting for free layout and application planning services, if needed. 1A 2B 2L 3T 3Y 4C 1W Type II Type III Type IV Type V Sq KIM LIGHTING 9

Optical Design Features Advanced Heat Management WARP9 s die-cast housing is a homogeneous component in which every feature has a functional purpose. HID lamps produce significant heat, yet are operated by temperature sensitive electrical components. Because of its compact, low profile size, new methods of controlling heat were required for WARP9. A combination of cooling ribs, ventilation, and a solid barrier wall between the optical chamber and the ballast compartment are employed to control operating temperatures for maximum component life. Rotatable Optics All WARP9 reflectors are field rotatable in 90 increments. This allows design flexibility in producing very high illumination levels for special applications, or for maintaining a consistent fixture orientation throughout the site. Each reflector is labeled to show the orientation of the light pattern, and can be field adjusted after initial installation. For applications requiring high light levels, such as sports facilities, auto dealerships, or service stations, reflectors can be aimed in parallel to double illumination levels. 10 KIM LIGHTING

Four rotatable reflector options featuring new 95% Alzak reflectivity Horizontal lamp orientation for uniformity and cutoff control One-piece silicone gasket with high memory retention Barrier wall completely separates optical chamber from electrical components Unique low profile frameless lens Totally sealed optical chamber stays clean for decades Multiple HID lamp options, electronic or magnetic ballasted versions Unique Frameless Lens WARP9 employs a unique frameless lens for several purposes. For improved camouflaging, the frameless lens lends to the sleek profile and reduced mass of the housing envelope, also reducing the amount of geometrical and straight lines that tend to attract the human eye. Second, the frameless lens allows for a consistent and positive gasket seal to completely isolate the optical chamber from moisture, air, and insect entry. Finally, fewer component pieces reduce overall fixture weight and improve allowable EPA. Multiple Lamp Options 42W 57W 60W 70W /+ + 85W PMH MH HPS PL IF 100W /+ + 150W /+ + 175W + 200W /+ 250W /+ + + 320W /+ 350W /+ 400W /+ + + PMH = Pulse Start Metal Halide MH = Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent IF = Induction Fluorescent WP9SE / WP9LE(electronic) = WP9SM / WP9LM(magnetic) = + KIM LIGHTING 11

Mechanical Features Aluminum Titanated Zirconium Conversion Coating Powder Coat New Stealth Gray TM Finish Diecast Aluminum Components Durable Powder Coat Finish WARP9 s housing and arm assembly are die-cast, low copper alloy (<0.6% Cu) aluminum for precision and repeatability. The housing is internally reinforced at the arm connection, and cooling fins are integral with the top surfaces. This self-cooling feature substantially reduces the operating temperatures on heat-sensitive electrical components, promoting extended life. A concealed diecast latch is designed into the nose of the fixture allowing no-tool entry into the optical chamber for lamping. In addition, the completely separated ballast compartment is accessed through a flush, bottom mounted tool-less slide latch for servicing electrical components and wiring access. Kim Lighting s state-of-the-art proprietary powder coat paint system is engineered to provide the highest quality finish with absolute paint adhesion under weather extremes. The Super TGIC thermoset polyester powder coat finish is applied over a titanated zirconium conversion coating. This finish system has exceeded the ASTM 2500 hour salt spray test. Eight Stage Finish 1. Power wash and degrease. 2. Detergent tank bath. 3. Clear water rinse bath. 4. Premium titanated zirconium conversion coating as used in the automobile industry. 5. Clear water rinse bath. 6. Dry off oven. 7. Powder coating, 2.5 mil nominal thickness. 8. Bake for 20 minutes at 410 F. 12 KIM LIGHTING

Completely new field-rotatable reflector systems with 95% reflectivity Kim Lighting s durable Super TGIC powder coat paint finish, featuring Stealth Gray Concealed die-cast no-tool latch allows easy access to optical chamber One-piece silicone gaskets assure positive seal after relamping Integrated cooling ribs for advanced heat management Die-cast aluminum arm attachment Die-cast aluminum housing Isolated wiring and electrical component chamber KIM LIGHTING 13

Installation & Maintenance Features Easy Installation and Set-Up No-Tool Maintenance The attachment of lighting fixtures to poles is often a neglected detail that ruins a clean design with boxy armatures and exposed nuts, bolts, or screws. WARP9 s arm connection naturally integrates and blends with the fixture head for a clean, strong appearance without exposed hardware or attachments. WARP9 also utilizes an internal mounting-bolt system concealed within the arm, fixture, and pole for maximum rigidity and assured coupling. Inside the pole top, a reinforcing plate receives the mounting bolts. A strain relief is provided on the reinforcing plate for securing the field wires. The cast-aluminum arm has concealed mounting bolts accessible through a flush cover that blends with the arm pre-assembled at Kim Lighting. The arm is configured to complement the fixture design and make the fixture-to-pole connection look natural, logical, and homogeneous. Ease of maintenance is a feature that distinguishes a lifetime product from an inferior substitution. WARP9 utilizes modular construction for easy installation and maintenance, and to allow for upgrading as lamp technology advances. To reduce expensive lift-truck rental time, relamping can be quickly accomplished without tools. A single latch on the nose of the fixture opens the hinged frameless lens. If ballast replacement is required, the entire electrical module is accessed through a separate latched door on the underside of the fixture, and includes quick-disconnect plugs on all wiring. A spare electrical module can be quickly inserted to eliminate downtime, while the old module can be repaired and stored for future use. 14 KIM LIGHTING

Proportion Guide Electronic ballast versions shown. KIM LIGHTING 15

Ordering Information 1 Mounting: Ordering Example: For standard fixture and pole 3Y configuration is available for round poles only. Mounting Fixture Electrical Module Finish Options Pole VSF Option 2SB /WP9LE3/ 250PMH277 / SG-P/ A-25 / PRA20-4188SB / SG-P / VSF-2SB 1 2 3 4 5-11 12 13 See separate Kim Pole Catalog. Omit for 1W Wall Mount. Plan View: EPA WP9L: 0.95 1.9 1.47 2.4 2.4 2.7 n/a EPA WP9S: 0.52 1.04 0.82 1.3 1.3 1.5 n/a Cat. No.: 1SA 2SB 2SL 3ST 3SY 4SC 1SW Wall Mount 2 Fixture: Cat. No. designates fixture and light distribution 3 Electrical Module: PMH = Pulse Start Metal Halide MH = Metal Halide HPS = High Pressure Sodium PL = Compact Fluorescent IF = Induction Fluorescent See lamp and electrical data on pages 20-21 Light Distribution: Type II Type III Type IV Type V Forward Throw Square Full Cutoff Full Cutoff Full Cutoff Full Cutoff Warp9 Small Electronic Ballast: WP9SE2 WP9SE3 WP9SE4 WP9SE5 Warp9 Small WP9SM2 WP9SM3 WP9SM4 WP9SM5 Magnetic Ballast: Warp9 Large Electronic Ballast: WP9LE2 WP9LE3 WP9LE4 WP9LE5 Warp9 Large WP9LM2 WP9LM3 WP9LM4 WP9LM5 Magnetic Ballast: Warp9 - Small / Electronic Pulse Start Metal Halide 70PMH120 70PMH208 70PMH240 70PMH277 100PMH120 100PMH208 100PMH240 100PMH277 150PMH120 150PMH208 150PMH240 150PMH277 Compact Fluorescent 42PL120 42PL208 42PL240 42PL277 57PL120 57PL208 57PL240 57PL277 Warp9 - Large / Electronic Pulse Start Metal Halide 200PMH120 200PMH208 200PMH240 200PMH277 250PMH208 250PMH240 250PMH277 320PMH208 320PMH240 320PMH277 350PMH208 350PMH240 350PMH277 400PMH208 400PMH240 400PMH277 Induction Fluorescent* 100IF120 150IF120 100IF208 150IF208 100IF240 150IF240 100IF277 150IF277 100IF347 150IF347 100IF480 150IF480 * Available in Type I I distribution only Lamp Lamp Line Watts Type Volts 250 PMH 277 Warp9 - Small / Magnetic Pulse Start Metal Halide 70PMH120 150PMH120 70PMH208 150PMH208 70PMH240 150PMH240 70PMH277 150PMH277 70PMH347 150PMH347 70PMH480 150PMH480 100PMH120 100PMH208 100PMH240 100PMH277 100PMH347 100PMH480 High Pressure Sodium 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 70HPS480 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 100HPS480 150HPS120 150HPS208 150HPS240 150HPS277 150HPS347 150HPS480 Metal Halide 175MH120 175MH208 175MH240 175MH277 175MH347 175MH480 Warp9 - Large / Magnetic Pulse Start High Pressure Metal Halide Sodium 200PMH120 350PMH120 150HPS120 200PMH208 350PMH208 150HPS208 200PMH240 350PMH240 150HPS240 200PMH277 350PMH277 150HPS277 200PMH347 350PMH347 150HPS347 200PMH480 350PMH480 150HPS480 250PMH120 400PMH120 250HPS120 250PMH208 400PMH208 250HPS208 250PMH240 400PMH240 250HPS240 250PMH277 400PMH277 250HPS277 250PMH347 400PMH347 250HPS347 250PMH480 400PMH480 250HPS480 320PMH120 400HPS120 320PMH208 400HPS208 320PMH240 400HPS240 320PMH277 400HPS277 320PMH347 400HPS347 320PMH480 400HPS480 Metal Halide 175MH120 175MH208 175MH240 175MH277 175MH347 175MH480 250MH120 250MH208 250MH240 250MH277 250MH347 250MH480 400MH120 400MH208 400MH240 400MH277 400MH347 400MH480 16 KIM LIGHTING

4 Finish: Super TGIC powder coat paint over titanated zirconium conversion coating. (see page 12) Color: Black Dark Bronze Stealth Gray TM Platinum Silver White Custom Colors Cat. No.: BL-P DB-P SG-P PS-P WH-P CC-P Consult your Kim Lighting representative for custom colors. 5 Wall Mounting: Cat. No.: 1W A cast-aluminum mounting plate is mounted to the wall with four bolts (by others). Fixture and arm are mounted to the cast aluminum cover plate before attaching to the wall mounting plate. The fixture-arm-cover plate assembly is hooked to the wall mounting plate and secured with stainless steel screws provided. Field splices are made at the opening in the cover plate. Cover is finished to match arm and fixture color. 6 Optional Photocell Button Receptacle Cat. No.: A-25 Receptacle A-30 - A-35 Button Two types of photocell controls are available. A receptacle for a NEMA base photocell (by others) would be located above the electrical compartment. For all multiple-fixture pole mountings with two or three fixtures, one fixture has a receptacle to operate the others. Four fixtures (250 watt or less) also require one fixture with a receptacle. Four fixtures (400 watt) require two fixtures with receptacles. Also available is an internal photocell with a button sensor on the left side of the fixture. For multiplefixture pole mountings, one fixture has a photocell to operate the others. 7 Optional SLX Lexan Non-Yellowing Lens: SLX Lexan Lens Cat. No.: SLX One-piece non-yellowing vacuum formed advanced polymer (SLX Lexan from GE Advanced Materials) enclosure covers standard tempered glass lens. CAUTION: Use only when vandalism is anticipated to be high. 8 Optional Houseside Shield: HS for flat lens Cat. No.: HS Recommended for use with clear lamps only. Effectiveness is reduced for coated lamps. Not for use with Type V Sq light distributioons. 9 Optional Neighbor Friendly Shield: Cat. No.: NFS (Type IV only) Stamped internal shield and blocking panels are used todirect and redirect lighting into a forward throw distribution. The amountof light directed and redirected toward the back of the luminaire isdramatically reduced to create extremely low glare behind the pole. Only available on the Type IV reflectors. 10 Optional Tamper- Resistant Latch: Tamper-Resistant Latch Cat. No.: TL Standard die-cast latch is provided with a captive 10-32 stainless steel flat socket-head screw to prevent unauthorized opening. Required only for vandal protection in locations where fixtures can be reached by unauthorized persons. 11 Optional Horizontal Slipfitter Mount: Slipfitter Cat. No.: HSF Replaces standard mounting arm with a slipfitter for mounting to a horizontal pole davit-arm with 2" pipe-size mounting end (2C" O.D.). Provides ±5 vertical fixture adjustment. 12 Special Options for Street Lighting: Cat. No.: TB Terminal Block located inside the fixture electrical compartment. (For Large Only) 13 Poles: 14 Optional Vertical Slipfitter Mounts: See Kim Pole Catalog for a complete selection of square and round poles in aluminum or steel. Round Cat. No. Cat. No Mounting Configuration VSF-1SA SVSF-1SA 1SA - Single arm mount VSF-2SB SVSF-2SB 2SB - 2 at 180 VSF-2SL SVSF-2SL 2SL - 2 at 90 VSF-3ST SVSF-3ST 3ST - 3 at 90 VSF-3SY Square 3SY - 3 at 120 VSF-4SC SVSF-4SC 4SC - 4 at 90 Allows standard fixture and arm to be mounted to poles having a 2" pipe-size tenon (2C" O.D. x 4K" min. length). KIM LIGHTING 17

Luminaire Specifications Dimensions - Electronic Ballast WP9LE Large Electronic Ballast 200 to 400 watt PMH Mogul Base Lamps 100 and 150 watt IF EPA:.95 Maximum weight: 35 lb. electronic WP9SE Small Electronic Ballast 42 to 150 watt PMH and PL Medium Base Lamps EPA:.52 Maximum weight: 17 lb. electronic TOP TOP 5K" (139.7 mm) 35B" (892.2 mm) 10M" (261.9 mm) 4B" (104.7 mm) 26I" (684.2 mm) 8I" (227.0 mm) 1I" (49.2 mm) FRONT 10M" (261.9 mm) SIDE 5I" (150.8 mm) 1K" (38.1 mm) FRONT 8I" (227.0 mm) SIDE 5N" (141.3 mm) 5B" (130.2 mm) 4G" (112.7 mm) 20" (508.0 mm) 15" (381.0 mm) BOTTOM BOTTOM SPECIFICATIONS HOUSING: One-piece die-cast, low copper alloy (<0.6% Cu) aluminum with integral cooling ribs over the electrical compartment. Solid barrier wall separates optical and electrical compartments. A single die-cast aluminum cam-latch provides positive locking and sealing of the optical chamber. A one-piece extruded and vulcanized silicone gasket seals the housing against the lens surface. LENS: Clear F" thick tempered glass lens retained by a stainless steel piano hinge and a single die-cast aluminum cam-latch. The edges are camouflaged to conceal the outer portion of the housing. LAMP AND BALLAST SYSTEM: The inductively coupled electrodeless lamp uses magnetic inducton technology to generate light. The absense of electrodes allow much longer lamp life up to 100,000 hour average rated life. ELECTRONIC BALLAST MODULE: One-piece die-cast, low copper alloy (<0.6% Cu) aluminum with integral cooling ribs over exposed bottom surface. Integral hinges and slide latch with stainless steel hardware provides no-tool mounting and removal from housing. All electronic components are UL and CSA recognized and mounted directly to the ballast tray for maximum heat dissipation. MAGNETIC BALLAST MODULE: One-piece die-cast, low copper alloy (<0.6% Cu) aluminum with integral cooling ribs over exposed bottom surface. Integral hinges and slide latch with stainless steel hardware provides no-tool mounting and removal from housing. All electrical components are UL and CSA recognized and mounted directly to the ballast tray for maximum heat dissipation. REFLECTOR MODULE: High specular optical segments are rigidly mounted within carrier plates to maintain form. No fasteners are placed on the reflective surface. The entire assembly is rotatable in 90 increments and fastened to the housing as a one-piece module. The appropriate socket is rigidly attached to the reflector module. SUPPORT ARM: Heavy cast, low copper alloy aluminum with stainless steel mounting bolts. A pole reinforcing plate is provided with wire strain relief. Arm is circular cut for specified round pole. FINISH: Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Stealth Gray, Platinum Silver, or White. Custom colors are available CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes, Failure to do so may result in serious personal injury. Listings and Ratings UL cul 1598 1 CE IP66 25C Ambient 1 Suitable for wet locations. Kim Lighting reserves the right to change specifications without notice. 18 KIM LIGHTING

Dimensions - Magnetic Ballast WP9LM Large Magnetic Ballast 150 to 400 watt PMH, HPS and MH Mogul Base Lamps WP9SM Small Magnetic Ballast 70 to 175 watt PMH, HPS and MH Medium Base Lamps EPA:.95 Maximum weight: 41 lb. magnetic TOP EPA:.52 Maximum weight: 21 lb. magnetic TOP 5K" (139.7 mm) 35B" (892.2 mm) 10M" (261.9 mm) 4B" (104.7 mm) 26I" (684.2 mm) 8I" (227.0 mm) 1I" (49.2 mm) FRONT 10M" (261.9 mm) SIDE 5I" (150.8 mm) 1K" (38.1 mm) FRONT 8I" (227.0 mm) SIDE 5N" (141.3 mm) 5B" (130.2 mm) 4G" (112.7 mm) 20" (508.0 mm) 15" (381.0 mm) BOTTOM BOTTOM KIM LIGHTING 19

Lamp Guide Lamp Watts Lamp Type System Watt Bulb Type Initial Lumens Life (Hours) PULSE START METAL HALIDE 70 PMH 90 Clear, ED17, Med Base 6,200 16,000 M98-30C HX-HPF 120 0.85 1.90 0.80 4 Clear, T6, G12 Base 6,600 M143 208 0.52 1.00 0.50 3 240 0.44 0.90 0.43 2 277 0.39 0.80 0.39 2 347 0.28 0.70 0.20 2 480 0.23 0.50 0.26 2 70 PMH 80 Clear, ED17, Med Base 6,200 16,000 M98-30C Electronic 120 - - 0.67 4 Clear, T6, G12 Base M143 208 - - 0.45 3 M139 240 - - 0.38 2 277 - - 0.30 2 100 PMH 129 Clear, ED17, Med Base 9,000 16,000 M140-30C HX-HPF 120 1.15 2.30 1.20 6 208 0.66 1.40 0.80 4 240 0.58 1.15 0.65 3 277 0.50 1.00 0.60 3 347 0.40 1.00 0.40 2 480 0.30 0.55 0.30 2 100 PMH 110 Clear, ED17, Med Base 9,000 16,000 M90-30C Electronic 120 - - 0.92 6 M140 208 - - 0.70 4 240 - - 0.60 3 277 - - 0.40 3 150 PMH 185 Clear, ED17, Med Base 14,000 16,000 M102-30C HX-HPF 120 1.60 3.65 1.75 10 Clear, T6, G12 Base M142 208 1.00 2.10 1.30 5 240 0.80 1.80 0.85 5 277 0.70 1.58 0.77 4 347 0.55 1.25 0.65 3 480 0.42 0.81 0.45 3 150 PMH 165 Clear, ED17, Med Base 14,000 16,000 M102-30C Electronic 120 - - 1.40 10 Clear, T6, G12 Base M142 208 - - 1.00 5 240 - - 0.80 5 277 - - 0.60 4 200 PMH 240 Clear, T15, Mogul Base 19,000 15,000 M136-30C Super 120 2.00 2.00 0.75 6 CWA 208 1.20 1.20 0.40 4 240 1.00 1.00 0.35 3 277 0.85 0.85 0.30 3 347 0.70 0.65 0.25 2 480 0.50 0.50 0.18 2 200 PMH 229 Clear, T15, Mogul Base 19,000 15,000 M136-30C Electronic 120 - - 2.00 6 208 - - 1.20 4 240 - - 1.00 3 277 - - 1.00 3 250 PMH 295 Clear, BT28, Mogul Base 22,500 11,250 M138-30C CWA 120 2.50 1.40 2.30 8 M153 208 1.45 0.80 1.30 5 240 1.25 0.70 1.15 5 277 1.10 0.60 1.00 3 347 0.95 0.75 0.45 3 480 0.57 0.48 0.21 2 250 PMH Clear, BT28, Mogul Base 22,500 11,250 M138-30C Electronic 208 - - 1.36 5 M153 240 - - 1.19 3 277 - - 1.06 3 320 PMH 368 Clear, BT28, Mogul Base 30,000 20,000 M132-30C Super 120 3.25 2.30 1.80 8 M154 CWA 208 1.90 1.35 1.05 6 M170 240 1.65 1.15 0.90 5 277 1.40 1.00 0.80 3 347 1.10 0.80 0.70 3 480 0.80 0.60 0.45 5 320 PMH Clear, BT28, Mogul Base 30,000 20,000 M132-30C Electronic 208 - - 1.70 8 M154 240 - - 1.49 6 M170 277 - - 1.32 5 350 PMH 400 Clear, BT28, Mogul Base 33,000 20,000 M131-30C Super 120 3.40 2.20 2.20 10 M171 CWA 208 2.00 1.30 1.30 7 240 1.70 1.10 1.10 5 277 1.50 1.00 1.00 5 347 1.20 0.80 0.85 3 480 0.85 0.60 0.60 3 350 PMH Clear, BT28, Mogul Base 33,000 20,000 M131-30C Electronic 208 - - 1.84 10 M171 240 - - 1.59 7 277 - - 1.41 5 400 PMH 452 Clear, BT28, Mogul Base 40,000 20,000 M135-30C Super 120 4.00 3.00 3.50 10 M155 CWA 208 2.30 1.75 2.00 7 M172 240 2.00 1.50 1.75 5 277 1.75 1.30 1.50 5 347 1.35 0.75 1.10 4 480 1.00 0.60 0.75 3 400 PMH Clear, BT28, Mogul Base 40,000 20,000 M135-30C Electronic 208 - - 2.10 10 M155 240 - - 1.81 7 M172 277 - - 1.59 5 ANSI Code Starting Temp Circuit Type Voltage Operating Amps. Open Circuit Amps. Starting Amps. Min. Fuse Amps. 20 KIM LIGHTING

Lamp Watts Lamp Type System Watt Bulb Type Initial Lumens Life (Hours) METAL HALIDE 175 MH 210 Clear, ED17, Med Base 14,400 7,000 M57-30C CWA 120 1.80 1.80 1.30 5 208 1.04 1.04 0.75 3 240 0.90 0.90 0.65 3 277 0.80 0.80 0.55 2 347 0.65 0.65 0.50 2 480 0.45 0.45 0.35 2 250 MH 295 Clear, BT28, Mogul Base 23,000 7,000 M58-30C CWA 120 2.60 2.60 1.00 8 208 1.50 1.50 0.60 5 240 1.30 1.30 0.50 5 277 1.10 1.10 0.45 3 347 0.85 1.05 0.35 3 480 0.65 0.65 0.30 2 400 MH 458 Clear, BT28, Mogul Base 40,000 15,000 M59-30C CWA 120 4.00 3.20 2.50 10 208 2.30 1.80 1.40 7 240 2.00 1.60 1.20 5 277 1.70 1.50 1.00 5 347 1.35 1.35 0.80 4 480 1.00 0.75 0.90 3 HIGH PRESSURE SODIUM 70 HPS 91 Clear, ED17, Med Base 6,300 24,000 S62-40C HX-HPF 120 208 0.81 0.47 1.45 0.85 0.75 0.45 6 4 240 0.4 0.75 0.37 3 277 0.35 0.65 0.35 3 347 0.3 0.55 0.3 2 480 0.21 0.36 0.21 2 100 HPS 130 Clear, ED17, Med Base 9,500 24,000 S54-40C HX-HPF 120 1.15 2.20 1.30 7 208 0.67 1.25 0.75 5 240 0.58 1.10 0.65 3 277 0.50 0.85 0.60 3 347 0.39 0.70 0.45 3 480 0.22 0.34 0.21 3 150 HPS 188 Clear, ED17, Med Base 16,000 24,000 S55-40C HX-HPF 120 1.65 2.80 2.00 10 208 0.95 1.60 1.15 5 240 0.83 1.40 1.00 5 277 0.72 1.25 0.85 4 347 0.56 0.92 0.52 3 480 0.42 0.70 0.50 2 250 HPS 295 Clear, E18, Mogul Base 29,000 24,000 S50-40C CWA 120 2.50 1.70 1.65 7 208 1.50 1.00 0.95 4 240 1.30 0.85 0.80 4 277 1.10 0.75 0.70 3 347 0.93 0.70 0.60 2 480 0.63 0.45 0.40 2 400 HPS 464 Clear, E18, Mogul Base 51,000 24,000 S51-40C CWA 120 3.80 2.00 3.30 10 208 2.20 1.20 1.80 6 240 1.90 0.95 1.50 5 277 1.70 0.85 1.40 5 347 1.32 0.70 1.00 5 480 0.97 0.55 0.75 3 COMPACT FLUORESCENT 42 PL 46 Coated, GX24q-4 Base 3,200 12,000 N/A -18C Electronic 120 - - 0.39 2 208 - - 0.23 2 240 - - 0.20 2 277 - - 0.17 2 57 PL 59 Coated, GX24q-5 Base 4,300 12,000 N/A -10C Electronic 120 - - 0.80 2 208 - - 0.40 2 240 - - 0.27 2 277 - - 0.21 2 INDUCTION FLUORESCENT Max. Fuse Amps. 100 IF 120 - - 0.88 3 208 - - 0.66 2 240 - - 0.37 2 277 - - 0.29 2 150 IF 120 - - 1.34 4 208 - - 1.28 4 240 - - 0.58 2 277 - - 0.54 2 All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturer s data for exact lumen and life data. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others. ANSI Code Starting Temp Circuit Type Voltage Operating Amps. Open Circuit Amps. Starting Amps. Min. Fuse Amps. KIM LIGHTING 21

TM www.kimlighting.com Because of a continuing product improvement program, Kim Lighting reserves the right to change specifications without notice. How may we serve you better? Let us know by visiting our web site at: www.kimlighting.com Hubbell Lighting, Inc.