Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Similar documents
Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

JABSCO & Series 1½ 80 SIZE UTILITY Pump

SELF PRIMING CHEMICAL SERVICE PUMPS

Model &

M-3025CB-AV Fuel Pump

SUBMERSIBLE WATER PUMPS

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

1 ELECTRIC WATER PUMP

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

AHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A

END SUCTION CENTRIFUGAL PUMPS

POND PUMP Model Nos:SPP3 & SPP6 0200

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

Owners Manual: - Pumps

1200W INVERTER GENERATOR

SUBMERSIBLE WATER PUMP

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Installation and Operating Instructions for

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

AHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM

SUBMERSIBLE WATER PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

Medium and high pressure pumps

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

SUBMERSIBLE WATER PUMP

Material required for drilled well application (indoor use only)

M Series Condensate Recovery Unit

To the Fitter: Ensure all relevant personnel read the points listed below and that a copy is passed on to the end user.

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

VT Oil-Free Range Operators Handbook

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Starting up hydraulic systems

12V PORTABLE PRESSURE PUMP

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

FUEL PRESSURE KIT JAGUAR LAND ROVER PETROL & DIESEL

8000 / 10,000 / 12,000

CFT24 &CFT230 PART NOS:

SUBMERSIBLE DIRTY WATER PUMP

SWIMMING POOL PUMPS Models SPP07, SPP10 & SPP15 Part Nos: , &

OPERATION & MAINTENANCE INSTRUCTIONS

Flojet Rewrites the Book on Small Pump Control

Instruction Manual. Maximum Operating Pressure 510 bar

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

LAWN SPRINKLER, IRRIGATION PUMP

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Hydraulic Projects Ltd

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Installation & Operating Manual

Operations Manual. and. Seal Kit Replacement Guide

OWNER S TECHNICAL MANUAL OWNER S TECHNICAL MANUAL

Instruction Manual. Maximum Operating Pressure 700 bar

SAFETY AND OPERATING MANUAL

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

SUNC3000 / Item #40885

I. INSTALLATION INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

Manual for 12 Sand Filter/ Pump Combo Unit.

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

FARMMASTER. JJ & OJ Series

OPERATION & MAINTENANCE INSTRUCTIONS

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

MODEL SS INSTALLATION INSTRUCTIONS

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Breezair TBA 550 Installation Manual

MODEL P INSTALLATION INSTRUCTIONS

BOOSTER PUMPS Models Nos: BPT600 & BPT1200SS Part Nos: &

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

ENGINE DRIVEN 3 FULL TRASH PUMP

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

PETROL DRIVEN POWER WASHER

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Marlow Series Cast Iron Swimming Pool Pumps

230V 60Hz LINE FUSES AM CLASS:

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

HALLMARK INDUSTRIES INC

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

INSTALLATION INSTRUCTIONS

Air Compressor. Models: CFP9HND. Operating & Maintenance Instructions

BP3000 / BP3010 / BP3020

Transcription:

24V DC-CW332 DOC531/11 Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. To obtain the best performance from your Pressurised water system please read these instructions carefully. Failure to observe the recommended procedures may result in early and severe damage, and may invalidate the supplier s guarantee. Xylem Water Solutions UK Ltd Bingley Road Hoddesdon Hertfordshire EN11 0BU UK Telephone: +44 (0)1462 480380 Fax: +44 (0)1462 482422 mail@cleghorn.co.uk www.jabscoshop.com

Contents: Page 1. Checking your pump on delivery... 2 2. Scope of use... 2 3. Installing the pump... 3 4. Fitting the accumulator tank... 4-5 5. Connecting the electric supply... 6 6. Starting the pump... 6-7 7. Operating the pump... 7 8. Maintenance & Repair... 8 9. Trouble Shooting... 8-9 10. Spare Parts... 10 1. CHECKING YOUR PUMP ON DELIVERY Your pump left our works in perfect condition. We want it to reach you in the same condition, and to provide you with long and trouble-free service. On receiving your pump, please make the following preliminary checks: 1. check that the model number conforms to your order 2. check that the details on the plate of the electric motor correspond to your power supply. 3. check that no damage has occurred in transit. Check for loose nuts and bolts and for missing parts. Did you order accessories or spare parts? Are they all there? Report immediately to your supplier any damage or missing or incorrect parts. Delay in notification may cause problems in dealing with claims under warranty. 2. SCOPE OF USE The CW332 pressure system is intended for use in pressurised fresh water systems. WARNING! This pump is not intended for use with fuel oils or with petrol, gasoline, benzene or other light-fraction petroleum fuels or solvents, and it must not be used for this purpose. The electric motor is not explosionproof or spark-protected, and is not suitable for use in areas where flammable vapours can occur.

3. INSTALLING THE PUMP 3 1. Locate the pump in a dry, well-ventilated space. Provide adequate access, so that maintenance work can be carried out without difficulty. 2. Secure the pump to a firm, horizontal base. Mounting on rubber pads can help to reduce vibration and transmitted noise. 3. The electrical installation should be carried out or supervised by a qualified electrician. With low-voltage d.c. units, it is particularly important to use adequately sized cable to minimise voltage drop. Refer to TABLE 1. If the pump is more than 6 metres from the battery, use a heavier grade of cable than that specified. TABLE 1 D.C. CABLE SIZE and FUSE RATINGS for cable runs up to 6m MODEL 24V d.c Conductor cross-sectional area per wire, mm 2 FUSE AMP CW332 6 20 4. The CW332 pump is self-priming. Maximum recommended suction lift is indicated in TABLE 2. MODEL TABLE 2 Maximum vertical suction lift (new pump) CW332 3 metres (10 ft ) The suction lift is the vertical distance from the lowest level of the water source to the centre line of the pump inlet port. Do not exceed this recommended maximum. For optimum pump life and performance, keep the suction lift to a minimum. 5. The inlet line to the pump should be as short and straight as possible, with a bore at least as large as the nominal bore of the pump inlet port. Use rigid or reinforced pipe that will not deform or collapse under suction conditions. The inlet pipe should be angled below the horizontal, to prevent entrapment of air and loss of prime when running. CORRECT

4 INCORRECT If a long inlet line is unavoidable, it may be advantageous to increase the size of the pipe. Check with your pump supplier if in doubt. Fit an inlet strainer to protect the pump from entry of solid material. The strainer should be of suitable material, with approximately 0.5mm mesh size and with an open area of at least 2½ times the cross-sectional area of the inlet pipework. The strainer should be inspected regularly and cleaned when necessary. Check the inlet line carefully for air leaks, which will stop the pump from priming itself. 6. The discharge line should preferably be of the same bore as the pump discharge port. Smaller pipework will limit the system flow rate. Pipework of reduced size may be used for branches to individual fittings. 4. FITTING THE ACCUMULATOR TANK 1. The accumulator tank should be teed off the pump discharge line and a convenient point within 2m of the pump. 2. The tank may be mounted in any orientation see fitting instructions for this. 3. Check the gas pressure of the tank at the time of installation. It should be already set at 0.7 bar (10psi). The pressure in the tank can be adjusted by means of the air valve in the closed end. Any pressure adjustment is best done before installation of the tank, using a car-type pressure gauge to determine when the required pressure is reached, as follows: I. Depress the central pin of the Schrader valve with your finger, to release gas II. Release gas a little at a time, until the pressure is correct III. If you release too much gas by mistake, air may be pumped back in with a hand or foot-pump. WARNING Make sure that there is adequate ventilation when setting or adjusting pressure in an accumulator tank. Nitrogen is non-toxic, but oxygen levels may be reduced in confined spaces. If the tank pressure requires adjustment after installation, ensure first that the pump is switched off and that an outlet is open, so that there is no pressure in the system. Then regulate the pressure as indicated above. Check the accumulator tank performance in this way every 6 months, and adjust the pressure if necessary.

5 Accumulator Tank Bracket Kit Fitting instructions

6 Your accumulator tank may be up to half - full of water in normal operation. It needs to be secured in place firmly to prevent movement and possible damage to pipe work and fittings. The accumulator tank contains an internal membrane, and may be mounted vertically, horizontally or in any convenient position close to the pump. Make sure that you have access to the air valve and to the threaded pipe connection. 1. Locate the bracket on the firm surface. Check the final position of the accumulator tank, and then secure the bracket firmly in the place with suitable screws. 2. Check that the worm - drive fastener is in the open position (see diagram). Pass the free end of the clip through the lower pair of holes in the bracket (vertical mounting) or through either pair (horizontal mounting). Only 1 clip is required to hold the accumulator tank securely in place; a second clip may be added but is not supplied with this kit. 3. Position the accumulator tank on the bracket and rotate the clip until the wormdrive fastener is in a convenient position to be tightened. Position the clip below the central welded seam of the accumulator tank. 4. Push the free end of the clip through the fastener as far as it will go. Close the worm - drive fastener (see diagram). Tighten the screw until the accumulator tank is firmly secured in place. Do not over - tighten. Trim off excess clip material. To avoid possible injury deburr cut edges with file. 5. CONNECTING THE ELECTRIC SUPPLY 1. Isolate the unit from the electric supply. 2. Connect the pump's power cable to the electric supply. 3. The unit is supplied with the motor pre-wired to its controls. Observe the correct polarity when connecting the motor lead to the power supply cable from the battery. 4. Connect the pump's power cable to the electric supply. 5. Check that a correctly rated fuse has been fitted in the power supply. 6. STARTING THE PUMP 1. Remove the filler plug on the top of the pump. Fill the pump body with water and replace the plug, ensuring that it is screwed fully home to make an air-tight seal. 2. Check that the wiring is complete and correct, that the motor terminal box cover is in place and that all enclosures containing live components have been secured. Turn on the power supply at the master switch. 3. The motor will rotate in the correct direction if it is connected with the polarity shown in its wiring diagram.

7 4. Check the water level in the supply tank, open taps and other outlets. Check that isolating valves in the inlet and discharge lines are fully open. 5. Switch on the pump. After a short time, water and air should start to flow from the open outlets. Allow a few seconds for the air to clear itself. If the pump has not primed itself and established a steady flow after about 20 seconds, stop the pump and investigate for air leaks in the inlet pipework. As soon as water flows smoothly from the taps, turn them off one by one. The pump should turn itself off within a few seconds of closing the last outlet. Your system is now ready for use. ESSENTIAL PRECAUTIONS Do not run the pump dry. Running the pump for more than a short time with no water in it will damage the shaft seal. A timer, or a level control in the water supply tank, will protect the pump. Contact your pump supplier for advice if necessary. Never restrict the inlet pipe while the pump is running. A restricted inlet line will give rise to low pressure with the risk of cavitation, loss of efficiency, vibration, noise and eventual damage to the pump. If the pump is to be shut down for an extended period, switch off the electric supply and open outlets to depressurise the system. Drain the pipework, water storage heater (calorifier) and pump casing if there is any risk of frost damage. Check regularly that the pump runs smoothly, delivers the required flow and pressure and does not leak. Investigate leaks, noisy running, or vibration immediately, to minimise the risk of damage or premature failure. If the pump loses performance or fails to reach its cut-out pressure, remember to check the electric supply voltage, at the motor terminals, with the pump running, as well as the condition of the pump itself. 7. Operating the pump Provided the pump has been correctly installed and commissioned, it should operate automatically on demand. The cut-in and cut-out pressures, and the air pressure in the accumulator tank, have been pre-set before delivery. The cut-in and cut-out pressures may be altered if required, by adjusting the settings in the pressure switch. Check with Cleghorn Waring that the pressure settings you propose are compatible with the unit. WARNING Before you alter the pressure settings, you are strongly advised to check that every component in the pressurised system is suitable for your intended maximum pressure. In particular, check the pressure rating of water storage heaters (calorifiers) and their pressure relief valves. Increased pressure may cause a relief valve to lift, resulting in a continuous loss of stored water.

[[[[ 8 8. Maintenance & Repair Your CW332 pump is designed to give long service with minimal attention. The shaft seal and the brushes in d.c. electric motors are wearing parts and may eventually need to be replaced. 9. Trouble Shooting PROBLEM POSSIBLE CAUSE ACTION Motor fails to start when switched on Motor hums but does not run Motor runs but no water flows Motor runs hot to touch; smell of burning - loose wiring - fuse blown - no power in pump circuit - check wiring - check cause, replace fuse - check power supply - pump has jammed - disconnect power; turn motor fan by hand, or open pump and turn by hand; investigate cause - air leak in inlet line - pump is not primed - pump has lost prime - air lock in inlet line - no water supply - inlet or discharge line blocked - inlet valve closed - blocked jet or impeller in pump - motor overloading and not properly protected - cavitation due to blocked inlet line - cut-out pressure set too high, pump runs continuously - water supply has run out, pump running dry - check inlet line, port connections, drain plug, priming plug - prime pump, open outlets - open outlets to allow pump to re-prime on starting - possible inlet air leak. - alter pipework layout - check supply tank - check pipework - check inlet valve - open pump and check for blockages - check cause: thermal cut-out setting, motor condition, fuse rating - check inlet line - check cut-out pressure - refill tank check for pump damage.

9 Insufficient flow or pressure Pump will not reach cutout pressure Pumps starts and stops rapidly Water escapes from air valve of accumulator tank - pump running in reverse - Inlet or discharge pipe blocked - air leak - low voltage - water tanks empty - blocked or worn impeller - blocked orifice in pressure switch - pump unable to reprime following loss of water supply - incorrect pressure switch settings - air leak - incorrect pressure in accumulator tank - ruptured membrane in accumulator tank - ruptured membrane in accumulator tank - check direction of pump rotation - check pipework, strainers - check pipework, strainers and pump connections - check voltage at pump, with pump running - check tanks - check condition of pump - check pressure switch - open all outlets and restart pump - correct settings. - check pipework, strainers and pump connections - check that pressure in accumulator tank is 0.25bar (4 psi) below pump cut-in pressure - check membrane - check membrane

10 10. Spare Parts REF DESCRIPTION 1 Drain plug 2 Pump body 3 Filler plug 4 Diffuser + Venturi 5 Impeller nut 6 Impeller 7 Mechanical Seal 8 O ring 9 Seal housing 10 Slinger 11 Motor 12 1 BSP non-return valve 13 1 BSP nipple 14 5 way adaptor 15 1 BSP plug 16 Pressure switch 17 Pressure gauge 18 8 litre accumulator tank 19 Accumulator tank fitting kit