Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Similar documents
POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

Model 1672, 1673 Triple Output Power Supply

DC REGULATED POWER SUPPLY

Triple Output Power Supply

DC REGULATED POWER SUPPLY

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Triple Output High Resolution Power Supply. User Manual

DC POWER SUPPLY ALIMENTATION C.C.

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

3000 Series Operation Manual

HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

INSTRUCTION MANUAL Model 1743B

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

Switching DC Power Supply

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Model 1900, 1901, 1902 Switching DC Power Supply

Model 1900, 1901, 1902 Switching DC Power Supply

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Model 1693, 1694 Switching DC Power Supply

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

DC POWER SUPPLY (Switching mode)

OPERATION and MAINTENANCE INSTRUCTION MANUAL

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

CX-SERIES ADVANCED BATTERY CHARGER

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

MODEL ELC-12/40-CVM-D BATTERY CHARGER

OPERATING INSTRUCTIONS

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Fiber Optic Illuminator. Model 21AC Model 21DC

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

SERIES 6000 FILM OPACITY METER MODEL RT REV A.1 INSTALLATION & OPERATION MANUAL

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

High Accuracy Series REGULATED DC POWER SUPPLY. User s Manual

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

MODEL ELC-12/60-D BATTERY CHARGER

OWNER S MANUAL Please read this manual before operating your power supply

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

SAFETY TERMS AND SYMBOLS

User s Manual Power Supply IM E. 5th Edition

user manual Electrophoresis Systems, Standards and Reagents PS 500XT DC power supply PS500XT-IM/Rev C0/9-99

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

SBC / 2140 / Stage Battery Charger User Manual

Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

EPS/ELA-Series User Manual EPS/ELA 250W

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

Boston Gear Ratiotrol DC Motor Speed Control

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

1. SAFETY TERMS AND SYMBOLS. Contents. 1. Safety terms and symbols Installation Operation.. 4

Combined Ventilation Controller RVWS-T-224HA

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400

4000 SYSTEM OPERATING MANUAL

Using Your SMT Micro Anodizer 0-120VDC/0-1A

innovations in battery charging

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

USER MANUAL. Insulation Tester + DMM. Model MG320

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

GFM-200A. Instruction Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

BL7000 SYSTEM OPERATING MANUAL

Boston Gear Ratiotrol DC Motor Speed Control

MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Parr Instrument Company

AeroVironment Universal Solar Pump Controllers

True RMS Autoranging Multimeter

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

CYCLONE DR Bolt PP-400BP Battery Pack for PP-400DR Portable Power Pack

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Bulbs are not included. FF-OF4 Octa 4 Socket Fluorescent Fixture INSTRUCTIONS

Autoranging Multimeter

58kHz AM Deactivator DB104 Instruction Manual V1.0

BRAVER UPS. (Uninterruptible Power System) User s Manual

C3 Operating Instructions

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

Replacing the Batteries in the Fortress LI 660

ALU-29CF Portable Light NSN:

Car Battery Charger Instructions for Use

Electrical Actuator HH-500 REsearch COntrol

Transcription:

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Copyright Elenco Electronics, Inc. REV-D

DC POWER SUPPLY 1 2 4 5 CURRENT VOLTAGE 13 3 6 C.C. C.V. 7 FINE COARSE FINE COARSE ON OFF GND + POWER 8 9 10 11 12 1. Voltage Meter 2. Ammeter 3. Coarse Voltage Adjustment 4. Fine Voltage Adjustment 5. Coarse Current Adjustment 6. Fine Current Adjustment 7. Constant Current Mode Indicator LED 8. Constant Voltage Mode Indicator LED 9. Power Switch 10. Negative Output Terminal 11. Ground Terminal 12. Positive Output Terminal 13. Zero Adjust (XP-605 only) 14. AC Input Voltage Switch 15. AC Input 16. Fuse Holder -1-14 15 16

INTRODUCTION Congratulations on your selection of a top quality power supply! The XP-605 has an output of 0-30VDC @ 5A; the XP- 752A has an output of 0-50VDC @ 3A. Their features include fine and coarse controls for voltage and current, and contains two analog volt/amp meters (XP-605); two digital volt/amp meters (XP-752A). The supply incorporates an externally controlled current cutoff circuit with an LED indicating current overload. Protected against short circuits and overloads. FEATURES Displays for voltage & current (analog - XP-605, LCD - XP-752A) Independent voltage and current controls Constant voltage (CV) or constant current (CC) operation LED indication for CV and CC for variable outputs Overload and short protected. Selectable AC input voltage, 115 or 230VAC SAFETY PRECAUTIONS Certain safety precautions must be observed when this power supply is used with external circuits that are connected to AC power lines. There is always some danger when working with electrical equipment or circuits that operate at hazardous voltages. You should thoroughly familiarize yourself with the equipment before using it. High voltage may appear at unexpected points in defective equipment. The unit is equipped with a three-wire line cord which grounds the chassis to power line ground. Do not cut off or disable the ground plug. The power supply secondary circuits are isolated from the 115/230V primary circuit via the power transformer. When working with other equipment, this may not always be the case. Always be familiar with the equipment rating. Keep in mind that defective equipment can have dangerous voltages in unexpected places. -2-

OPERATING INSTRUCTIONS 1. Set the AC input voltage switch on the back to the correct setting and the correct fuse (6A - 115V, 3A - 230V) installed. 2. Set the power switch to the off position. 3. Plug the power cord into the power socket on the back of the unit. 4. Plug the power cord into an AC output. Note: Make sure enough space is left for heat dissipation. 5. Check that the voltage rating of the equipment does not exceed the power supply s rating. Constant Current Mode 1. Turn the voltage control knobs (coarse and fine) fully clockwise and the current control knobs (coarse and fine) fully counter-clockwise. 2. Press the power ON/OFF switch to ON. The CC LED should be lit. 3. Connect the positive and the negative output terminals to a load or similar component. 4. Turn the current control knobs clockwise to the desired output current value. Constant Voltage Mode 1. Turn the current control (coarse and fine) knobs fully clockwise and the voltage control knobs fully counterclockwise. 2. Press the power ON/OFF switch to ON. The CV LED should be lit. 3. Turn the voltage control knobs clockwise to the desired output voltage. 4. Connect the positive and the negative output terminals to a load or similar component. -3-

Note XP-752A: Current limiting less than 1/2A or a shorted output activates the short circuit protection, turning the unit off. To reset unit, remove the short or load and readjust current limiting control. Setting Current Limit Protection Mode 1. Adjust the current and voltage control knobs to the desired output voltage. 2. Short the positive to the negative output terminal. 3. Press the power ON/OFF switch to ON. The CC LED should be lit. 4. Turn the voltage coarse knob clockwise 1/4 turn. 5.Set the maximum output current by turning the current coarse knob clockwise. This now limits the output current to your setting. CAUTION: In the event of a short circuit at the output, the current will limit at the value set by the current controls. However, the unit should be turned OFF and the short circuit removed before continuing use. The unit must be unplugged before servicing. Servicing should be performed by a qualified repairperson with knowledge in electrical hazards. The unit should be stored in a dry and well-ventilated place and the power cord removed if storing for a long period of time. Never place any objects on the power supply. Do not obstruct the ventilation holes. Avoid contacting the heat sink of the power supply as it can become very hot. Contacting the heat sink when it is hot could result in skin burns or damage to the equipment in contact with them. -4-

Never move or pull the power supply using the power cord or output lead. The unit is designed for INDOOR USE ONLY. SPECIFICATIONS Model XP-752A 0-50V XP-605 0-30V Output Current Line Regulation Load Regulation Ripple & Noise CV CC CV CC CV CC 3A < 0.01% +1mV < 0.2% +1mA < 0.01% +3mV < 0.2% +3mA < 0.5mV rms < 3mA rms 5A < 0.01% +1mV < 0.2% +1mA < 0.01% +3mV < 3A < 0.01% +5mV > 3A < 0.2% +3mA < 3A < 0.2% +5mA > 3A < 0.5mV rms < 3A < 1.0mV rms > 3A < 3mA rms < 3A < 6mA rms > 3A Input Voltage Protection Voltage Display Accuracy Current Display Accuracy Environment: 104 127VAC (60Hz) 207 253VAC (50Hz) Current limit and short circuit protection LCD +1% +2 digits, Analog +2.5% FSR LCD +2% +2 digits, Analog +2.5% FSR 32 O F - 104 O F (0 O F - +40 O C), relative humidity <90% Dimensions (H x W x L) 6¼ x 5¼ x 11½ (15.9 cm x 13.3 cm x 29.2 cm) Weight 10.1 lbs. / 4.58 kg. (XP-605) 9.85 lbs. / 4.47kg. (XP-752A) -5-

MAINTENANCE Cleaning Using a soft moistened cloth, remove any dirt on the outside of the case. The power supply should be used in a normal working environment. Servicing If the unit becomes inoperative or damage, Elenco Electronics or a qualified repairperson should only perform the repair and calibration. Fuse Replacement The power supply will not work if the fuse is blown or not installed. Check and repair any existing problems before installing new fuse. Only use fuses with same specification as original the one. Warning - To prevent fire use only 250V or greater with the specified current. 1. Disconnect the AC power before replacing the fuse. 2. Insert a small screwdriver into fuse holder slot (located between fuse holder and receptacle) and pry fuse holder from receptacle. 3. Replace the blown fuse and insert holder into receptacle. Be sure that the fuse is installed so that the correct line voltage is selected. Elenco fuse part numbers: AC Power 230V 3A fuse 250V (5 x 20mm) Part #: 530300 AC Power 115V 6A fuse 250V (5 x 20mm) Part #: 531030 4. Plug line cord back into the AC output and test unit. -6-

TWO YEAR WARRANTY All Elenco models are guaranteed for two full years on all parts and service. For the first 3 months, your power supply is covered at absolutely no charge. For the remaining 21 months, a nominal service charge is required to cover shipping and handling. When returning merchandise for repair, please include proof of purchase, a brief letter of explanation of problem, and sufficient packing material. Before returning any merchandise please call our service department at (847) 541-3800 to obtain a return authorization number (RMA). Elenco Electronics, Inc. 150 Carpenter Avenue Wheeling, IL 60090 (847) 541-3800 Website: www.elenco.com e-mail: elenco@elenco.com