NEXT UPS Systems MANTIS II Tower 750/1000/1500 Installation and user manual English

Similar documents
UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

EnergyBar 6. Setup Guide

EP12M248 7 Stage Automatic Smart Battery Charger, Desulphuration& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

Trouble Shooting Guide for AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves)

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW

E+ Battery Care Guide

INVERTER/CHARGER 1012/1024/1512/1524/2012/2024/3024/ /4048/5048/6048 INVERTER/CHARGER Appliances. Airconditioning Fridge

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles

Car Refrigerator PFN-C-WEA-25/35/45/55

Introduction Specifications Structure & Performance Assembly Folding Operation Care & Maintenance...

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm)

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS

Anemómetros digitales portátiles AN-100 extech manual ingles USER MANUAL. Model AN100. CFM/CMM Thermo Anemometer AN100

Operation & Maintenance Manual For Commercial Use Only

EDBRO RIGID INCLINOMETER

PSS INSTALLATION INSTRUCTIONS

BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE

LED Driver Feedback Signs

CS369-R51I Thank you very much for purchasing our air conditioner.

ADVISORY: General Motors Upfitter Integration Bulletin #108d P a g e 1 May 18, 2016

ABTQ-103 rev 01 Last review:

Installation Guide Contigo 6100

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems!

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

BUTTON CELL CR2430 BSI M G T E D BRIEF SPECIFICATION

30/40/50L Rechargeable Fridge/Freezer. Thank you for choosing our Rechargeable Fridge Freezer

Lithium Battery Shipping Overview

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D),

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator

Safety Rules. Danger Failure to obey the instructions and safety rules in this manual will result in death or serious injury. Do Not Operate Unless:

A L L Diagnostic Trouble Codes ( DTC ): P Code Charts P0302

BRAVER UPS. (Uninterruptible Power System) User s Manual

DriveCam Unit Installation Instructions

Installation Instructions AQ-5100, AQ-5200 & AQ-5300 Under Counter Water Filter Single Stage (5100), Two Stage (5200) and Three Stage (5300) systems

Tips & Technology For Bosch business partners

WELCOME. WEB LOCATION Los Angeles, CA

HANDLING AND STORAGE PRACTICE

IQUPS.com Have you checked the IQ of your Power Systems?

Installation instructions: 13 Pin Electrical system for towing hitch

BS1015C USER S MANUAL. MA13-02/B 12/09/2011

OWNER S MANUAL. DCR-205-XX-DC Powered Drum Rotators

WELCOME. WEB LOCATION Los Angeles, CA

Methanol Recovery Systems

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools

Instruction Manual. PHscan30 Pocket ph Tester

EasyPower User Manual

INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL

100 KW / 125 KVA POWERED by

UPS. Uninterruptible Power Supply MKD 700 / 1000 XL. Manual ACX11MKS1K0000XL

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211C PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools

Quark Brushless Systems

Uninterruptible Current Supply USV V / 1.2 Ah

Advanced 3 Million Wireless USB Limousine Underbody Kit

Solvent Filter. What is a Solvent Trap, Solvent Recycler or Solvent Filter? Why use a solvent filter? Why is the HIT Solvent Filter better?

Installation Guide Contigo 6150 & 6151

INSTALLATION INSTRUCTIONS

Safety and Operation. Original Instructions

INSTALLATION INSTRUCTIONS FOR PART #50015 DIESEL MPG-MAX WATER / METHANOL INJECTION SYSTEM 6.0L/6.4L/6.7L POWERSTROKE DIESEL

EDBRO TRAILER INCLINOMETER

DTC P0401 Exhaust Gas Recirculation Flow Insufficient Detected

Original Instructions

;THI~~Sf\-FEJY _.:.. ;'..»...

INSTRUCTION MANUAL 9500/12000 LBS. D9500SC / D9500SR / D9500SRD D12000SC / D12000SR / D12000SRD MODEL:

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

MT Pressure Switch INSTALLATION AND OPERATING INSTRUCTIONS. Kaustubha Udyog (Orion Instruments)

Instruction manual. Hako Hamster 500 E ( )

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS SECURITY SYSTEM KIT CONTENTS SHOCK SENSOR F-D15 WINDOW DECAL (QTY 2) F-D16

INSTALLATION INSTRUCTIONS FOR PART #20001 FORCED INDUCTION BOOST COOLER WATER / METHANOL INJECTION SYSTEMS

VALVE-REGULATED SEALED LEAD ACID BATTERY. FMJ GEL Series. High Performance. Product Guide

Delta RPI-M50A - India. Grid-Tied Solar Inverter RPI-M50A. The Power Behind Competitiveness. Product Features

BIG-VUE Series Meter

Mag-Nus2 MAGNETIC, SELF CLEANING, DIRT SEPARATOR

You have a Chiller, Now What?

PRE-PLANNING & DELIVERY GUIDE

BPC955 V0 Bliss Powercom Genset Controller. Kirloskar Electric Co. Ltd. User Manual

INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS

MG1 TM MAGNETIC SUPER-COMPACT SYSTEM FILTER

Effective Date: 10-January Table of Contents

Delta RPI-M50A. Grid-Tied Solar Inverter RPI-M50A. The Power Behind Competitiveness. Product Features

service.mattel.com COLORS AND DECORATIONS MAY VARY.

Delta RPI Commercial Series. Grid-Tied Solar Inverter RPI-M12 / RPI-M15A / RPI-M20A / RPI-M30. The Power Behind Competitiveness.

TCS and TCS-200-1H Tension Controls

72 Mustang Mach 1 tachometer cluster and gauge conversion

Instruction Manual. Scrubmaster B30 / B30 CL (7715)

Refer to the description for DTC P0C Refer to DESCRIPTION.

Operator s Manual with Maintenance Information. First Edition Eleventh Printing Part No

Tools Required. Installation. Step 1. Headlight lense removal (Driver's side shown, Passenger side similar)

Instruction Manual. Kleensweep KS 32 R ( )

Auxiliary Power Unit (APU) Owner s manual D

FEED SYSTEM ASSEMBLY & OPERATING INSTRUCTIONS

MEDMASTER TROFFER Luminaires for MRI/Imaging Suites LED MRIT SERIES

Mini H1 Twin Kit - Installation Instructions

Rejuvenation Instructions

Gearbox Installation Manual

Machine Safeguarding

Operator s Manual with Maintenance Information. Second Edition Fourth Printing Part No

How to Sweat (Solder) Copper Pipe By See Jane DrillTM Copyright 2013, All Rights Reserved

General Faucet Installation Instructions

Draft ADEM Guidance Proposed Additions to the Alabama UST Regulations

Thank you for purchasing a SledLites.com HID system for your snowmobile. Please read all warnings and complete manual prior to installing.

Transcription:

NEXT UPS Systems MANTIS II Twer 750/1000/1500 Installatin and user manual English

CONTENT IMPORTANT SAFETY INSTRUCTIONS... 1 1. Intrductin... 4 2. Descriptin f Features... 4 3. Package Cntents... 4 4. Prduct Overview... 5 5. Installatin and Initial Startup... 7 6. Functins & Operatin... 10 7. Sftware Installatin n yur PC... 11 8. Maintenance... 12 9. Truble Shting... 14 10. Specificatins... 15

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual cntains imprtant instructins fr NEXT UPS Systems MANTIS II Twer mdels 750VA, 1000VA, 1500VA that shuld be fllwed during installatin and maintenance f the UPS and batteries. This prduct is specially designed fr PCs and it is nt recmmended fr use in any medical equipment, life-supprting system and ther specific imprtant equipment. D nt plug husehld appliances such as hair dryers, micrwave vens r vacuum cleaners t UPS. D nt attach a pwer strip r surge suppressr t the UPS. D nt plug the UPS int its wn utput. Cnnectin t any ther type f receptable ther than tw-ple, three-wire grunded receptacle may result in shck hazard as well as vilate lcal electrical cdes. T reduce risk f verheating the UPS, d nt cver the UPS cling vents. This unit intended fr installatin in a cntrlled envirnment (temperature cntrlled, indr area free f cnductive cntaminants). Avid installing the UPS in lcatins where there is standing r running water r excessive humidity and d nt use it in any f the fllwing envirnments: Any area with cmbustible gas, crrsive substance r heavy dust. Any area with extrardinarily high r lw temperature (abve 40 C r belw 0 C) and humidity f mre than 90%. Any area expsed t direct sunshine r near any heating apparatus. Any area with serius vibratins. Outdr. The utility pwer utlet shall be near the equipment and easily accessible. In the event f an emergency, press OFF buttn and discnnect the pwer crd frm the AC pwer supply t prperly disable the UPS. 1

The internal shrt circuiting f the UPS will lead t dangers such as electric shck r fire; therefre d nt allw liquids r any freign bject t enter the UPS. N water cntainers (such as a water glass) r any ther liquid-cntaining vessels shall be placed n the tp f the UPS s as t avid such dangers as electric shck. Please d nt use the UPS in excess f the rated lad capacity. Unplug the UPS prir t cleaning and d nt use liquid r spray detergent. Risk f electric shck, d nt attempt t disassemble the unit. N user serviceable parts inside. Refer servicing t qualified service persnnel. If UPS is t be stred fr a lng time, it is recmmended t recharge the batteries (by cnnecting the utility pwer t UPS, switch ON ), nce a mnth fr 24 hurs t avid a full battery discharge. In case smke is fund cming ut frm the device, please cut ff the pwer supply quickly and cntact the distributr. The UPS cntains ne/tw large-capacity batteries. S the shell shall nt be pened, therwise such dangers as electric shck will be caused. If any internal verhaul r replacement f the battery is required, please cntact NEXT UPS Systems. Servicing f batteries shuld be perfrmed r supervised by persnnel knwledgeable f batteries and the required precautins. Keep unauthrized persnnel away frm batteries. A battery can present a risk f electrical shck and high shrt circuit current. The fllwing precautins shuld be bserved when wrking n batteries: Remve watches, rings, r ther metal bjects frm the hand. Use tls with insulated handles and wear rubber glves and bts. D nt lay tls r metal parts n tp f batteries. Discnnect charging surce prir cnnecting r discnnecting batteries terminals. When replacing batteries, replace with the same type and number f the sealed lead-acid batteries. The maximum ambient temperature rating is 40 C. 2

D nt dispse f battery r batteries in a fire. The battery may explde. D nt pen r mutilate the battery r batteries. Released electrlyte is harmful t the skin and eyes. It may be txic. Icn Φ n the rating label stands fr phase symbl. This pluggable type A equipment with battery already installed by the supplier is peratr installable and may be perated by laymen. During the installatin f this equipment it shuld be assured that the sum f the leakage currents f the UPS and the cnnected lads des nt exceed 3.5mA. Attentin, hazardus thrugh electric shck. Als with discnnectin f this unit frm the mains, hazardus vltage still may be accessible thrugh supply frm battery. The battery supply shuld be therefre discnnected in the plus and minus ple f the battery when maintenance r service wrk inside the UPS is necessary. In the event that there is fire ccurring in the vicinity, please use dry-pwer extinguishers. The use f liquid extinguishers may give rise t the danger f electric shck. This prduct cmplies with the safety and envirnmental regulatins in EU. If the time arises t thrw away yur prduct, please recycle all the cmpnents pssible. Batteries and rechargeable batteries are nt t be dispsed in yur dmestic waste! Please recycle them at yur lcal recycling pint. Tgether we can help t prtect the envirnment. 3

1. Intrductin MANTIS II Twer series is an intelligent and cmpact line interactive UPS (Uninterruptable Pwer Supply) which is designed t prtect yur persnal cmputer r sensitive electrnic equipments frm all frms f pwer interference, including cmplete pwer failures. It is equipped with many features that allw any attached equipment t perate lnger and mre reliability. 2. Descriptin f Features Easy t use and install utilized micrprcessr cntrl t maximize the reliability and efficiency Equipped with built-in bst and buck AVR functin DC Cld start functin Green Pwer Functin fr energy saving Aut restart while AC recvery. Prvides AC Overlad prtectin RJ11/RJ45 (in/ut) LAN/Mdem/Phne line prtectin 3. Package Cntents Yu shuld have received the fllwing items inside f package: UPS Unit USB Cable AC Input Pwer Crd AC utput Pwer crd User Manual 4

4. Prduct Overview I: Frnt Panel:! ON/OFF buttn " Scrll dwn buttn # Mute buttn $ LCD display II: Rear Panel: MANTIS II 750T MANTIS II 1000T/1500T! AC input " RJ11/RJ45 LAN/Mdem/phne line prtectin # USB prt $ IEC utlet! AC input " RJ11/RJ45 LAN/Mdem/phne line prtectin # USB prt $ IEC utlet % Fan 5

III: LCD descriptin:! UPS ON " AVR mde # Battery mde $ Internal fault % Output lad level & Battery level ' Input measurements ( Output measurements ) Measuring unit IV: UPS setting thrugh the LCD: Release scrll dwn buttn t select menu Example f setting Save the new value LCD will shut ff if there is n activity fr 3 minutes. (1) In lw sensitivity mde (L) UPS will tlerate mre fluctuatins in pwer and will g n battery pwer less ften. If the cnnected lad is sensitive t pwer disturbances, keep the sensitivity as Standard (Std). 6

5. Installatin and Initial Startup Befre installatin, please inspect the unit. Be sure that nthing is damaged. I: Placement & Strage Cnditins Install the UPS in a prtected area that is free f excessive dust and has adequate air flw arund the unit, and is free frm excessive dust, crrsive fumes and cnductive cntaminants. Please place the UPS away frm ther units at least 20 cm t avid interference. D NOT perate the UPS where the temperature exceeds 0-40 C and the humidity is ver 0-90 % RH. II: Cnnect t Utility and Charge Plug in the AC input crd t the 2-ple, 3-wire grunded wall utlet. Fr the best results, we suggest charging the battery at least 6 hurs with n lad (n electrical devices such as cmputers, mnitrs, rtc.) cnnected befre initial use. The unit charges its battery while cnnecting t the utility. 7

III: Cnnect the Lads Plug in the lads t utput receptacles n the rear panel f the UPS. Simply turn n the pwer switch f UPS unit, and devices cnnected t the UPS will be prtected by UPS unit. D nt attach a pwer strip r surge suppressr t the UPS. IV: Cnnect LAN cable, Mdem r Phne line fr Surge Prtectin Cnnect fr example a single mdem r phne line int surge-prtected IN utlet n the back panel f the UPS unit. Cnnect frm OUT utlet t the cmputer with anther phne line cable. V: Cnnect USB Cable T mnitr the UPS status, such as unattended UPS shutdwn and start-up, by using bundled sftware, please cnnect the UPS and PC with USB cable included. 8

NEVER cnnect a laser printer r scanner t the UPS unit, because in-rush current generated by mtr s devices may cause the damage f the unit. VI: Turn On/Off the Unit Turn n the UPS unit by pressing the On/Off buttn. Turn ff the UPS unit by pressing again the On/Off buttn. 9

6. Functins & Operatin I: DC Start Functin DC Start Functin enables UPS t be started up when AC utility pwer is nt available and battery is fully charged. Just simply press the pwer switch t turn n the UPS. II: Green Pwer Functin These series are equipped with Green Pwer Functin fr saving pwer and prtecting battery. The feature f deep discharge prtectin is adped n battery mde. If n r light lad is cnnected t the UPS, it will autmatically shut dwn after 5 minutes fr energy saving while running n battery mde (Disable by default). The UPS will restart while AC recvery. The green pwer functin can be enable nly by NEXTVisin mnitring sftware. III: AVR (Autmatic Vltage Regulatin) If the quality f the incming mains is pr, the AVR bsts a lw incming vltage r reduces a high ne. The lad receives a vltage within the nrmal range. IV: Aut restart while AC recvery V: Audi Indicatr Audible Alarm Sunding every 10 secnds Sunding every 3 secnds Sunding every 3 secnds Sunding every 1 secnds Situatin Battery Mde Battery Lw Overlad Faulty 10

7. Sftware Installatin n yur PC Cnnected by USB t a PC r ntebk, the Sftware enables cmmunicatin between the UPS and the cmputer. The UPS sftware mnitrs the status f the UPS, shuts dwn the system befre the UPS is exhausted and can remtely bserve the UPS via the Netwrk (enabling users t manage their system mre effectively). Upn AC failure r UPS battery lw, UPS takes all necessary actins withut interventin frm the system administratr. In additin t autmatic file saving and system shut-dwn functins, it can als send warning messages via SMS, e-mail etc. Use the bundled CD and fllw the n-screen instructins t install the sftware. Check ur website frt he latest versin f NEXTVisin (www.nextups.eu/sftware) After the sftware is successfully installed, the cmmunicatin with UPS has been established and a green NEXT icn will appear in the system tray. Duble-click the icn t use the mnitring sftware (as abve). Yu can schedule UPS shutdwn/start-up and mnitr UPS status thrugh PC. Detail instructins please refer t the e-manual in the sftware. 11

8. Maintenance I. General The UPS is virtually maintenance free: take care f prper envirnmental cnditins and keep air inlets-utlets free f dust. II. Fuses If the AC input fuse is defect, be sure it is replaced by a cmpatible fuse frm the same make and type. Never shrt circuit batteries. When wrking with batteries, remve watches, rings and ther metal bjects, and nly use insulated tls. III. Battery-mdule replacement Read all safety rules befre replacing the battery. Battery tray remval n twer mdels. This peratin can be perfrmed when the UPS is switched ON, and plugged int AC surce. Althugh fr safety reasns NEXT UPS Systems recmmends t perfrm this peratin when the unit is turned OFF and unplugged frm AC surce. A - Remve the frnt panel. B - Discnnect the battery blck by separating the tw cnnectrs (never pull n the wires). 12

C - Remve the metal prtectin cver in frnt f the battery (ne screw). D - Pull the plastic tab t remve the battery blck and replace it. Munting the new battery mdule Carry ut the abve instructins in reverse rder. T ensure safety and high perfrmance, use nly batteries supplied by NEXT UPS Systems. Take care t firmly press tgether the tw parts f the cnnectr during remunting 13

9. Truble Shting Symptm Pssible Cause Remedy N LCD display n the frnt panel. Alarm buzzer beeps cntinuusly when AC supply is nrmal. When pwer failure, back-up time is shrten. 1. Battery isn t cnnected. 1. Recnnect battery. 2. Battery defect. 2. Replace with the same type f battery. 3. On/Off buttn is nt pressed. 1.Overlad f the UPS. 2.Pwer crd is lse. 3. Press the On/Off buttn again. Verify that the lad matches the UPS capability specified in the specs. Recnnect the pwer crd prperly. 1. Overlad f the UPS. 1. Remve sme nn-critical lad. 2. Battery vltage is t lw. 2. Charge battery 6 hurs r mre. 3. Battery defect due t high temperature peratin envirnment, r imprper peratin t battery. 3. Replace with the same type f battery. If any abnrmal situatins ccur that are nt listed abve, please call NEXT UPS Systems service peple immediately. 14

10. Specificatins Mdel INPUT Vltage Vltage Range OUTPUT Vltage Vltage Regulatin Frequency Range Frequency Regulatin Transfer Time Wavefrm PROTECTION Full prtectin ENVIRONMENT Humidity Cmplete MANTIS II Twer Series 750 1000 1500 220/230/240 VAC 184~276 VAC 220/230/240 VAC -10%/+6% f nminal vltage range(line mde) 50/60Hz ±1Hz (Battery mde) Typical 3-7ms,10ms max Pure Sine Wave Discharge, vercharge and verlad prtectin 0-90 % RH @ 0 t 40 C (nn-cndensing) Nise Level Less than 40dB Less than 40dB @Line mde Less than 45dB @Battery mde Sftware Mnitring Sftware NEXTVIsin (included/dwnladable) CAPACITY 750VA / 500W 1000VA / 700W 1500VA / 900W BATTERY Type & Number 12V/ 9Ah x1 12V/7Ah x2 12V/9Ah x2 Charging Time 3 hurs recver t 90% capacity Backup Time (Half SPS lad) 9min 11min 8min PHYSICAL LCD Indicatr View Area: 30mm x 30mm (AC Mde, Backup Mde) Outlet and Cnnectr Dimensin (WxHxD) 4 * IEC 320 C13 utlets, USB prt, RJ11/RJ45 Surge Prtectin 150 mmx 209mm x 240mm 8 * IEC 320 C13 utlets, USB prt, RJ11/RJ45 Surge Prtectin 150mm x 209mm x 340mm WEIGHT Net weight 6.8kg 10.5kg 11.5kg 15