INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

Similar documents
TECHNICAL MANUAL MT064

USE AND MAINTENANCE MANUAL

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

USE AND MAINTENANCE MANUAL

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

TECHNICAL MANUAL MT029

HYDRAULIC CONTROL VALVES

USE AND MAINTENANCE MANUAL

CIRCLE SEAL CONTROLS

Pressure Reducing Valve Type 2114/2415

Installation and maintenance guide

CIRCLE SEAL CONTROLS

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

TECHNICAL DATA 1-1/2 (dn40)

DYNACTAIR 200 to MAINTENANCE

DK/CP DN PVC-U / PVC-C / PP-H / PVDF. Pneumatically actuated 2-way diaphragm valve

MONOVAR is the energy dissipating valve.

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Flow Control Valve IOM 770-U

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

BELT CONVEYOR PNL/4 Series User and maintenance manual

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

CSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP

TECHNICAL CHARACTERISTICS

Technical Data. UL Listing is based on the following criteria:

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

Installation, Operation, and Maintenance Manual

IOM IR-110-X. Solenoid Control Valve

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Worldwide Contacts.

Plunger Heads Use and Maintenance Manual

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

BELT CONVEYOR CB/M5 Series

Butterfly valves Figure 56 Installation & Maintenance Instructions

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Operating manual Separator

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

CSA products for waste water. Combination air valve. Mod. SCF 2

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

M MODEL FORK POSITIONERS

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

PNEUMATICALLY ACTUATED 2-WAY

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

PRESSURE REDUCING CONTROL VALVE

Installation, Operation, and Maintenance Manual

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

To ensure proper installation, digital pictures with contact information to before startup.

Orifice Flow Meters POP-S (E5720 rev /03/2013)

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

DKD/CP DN PVC-U. Direct action pneumatically actuated 2-way diaphragm valve

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

MODEL RCW DELUGE SYSTEM ELECTRIC, WET PILOT, AND DRY PILOT ACTUATION

485 - NC NO/DA DN

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

APT10-2 Automatic Pump Trap

VAG CEREX M300 Butterfly Valve

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Instructions for Installation, Operation, Care and Maintenance

APT14 Automatic Pump Trap Installation and Maintenance Instructions

3 Spin Klin Battery Operation and Maintenance Manual

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

ATTENTION: Industrial machinery for professional use. These instructions are for qualified personnel USE AND MAINTENANCE MANUAL

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

Fisher 2052 Diaphragm Rotary Actuator

Mounting and Operating Instructions EB 5868/5869 EN

The valves should be stored on a pallet or skid in a clean, dry warehouse. If the valves must be stored outside, the following apply:

Medium and high pressure pumps

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

TYPE E Main Valve Sizes 3 /8 through 12

CSA products for treated water. Equilibrium float valve. Mod. Athena

OPERATION AND SERVICE MANUAL. McGILL UNIVERSITY PROJECT: MCS-3237 SUBJECT: HYDRAULIC POWER UNIT AND ROTARY ACTUATORS DECEMBER 2001

Free Float Air Trap G8

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

VKD DN PP-H. DUAL BLOCK 2-way ball valve

DIAPHRAGM PUMPS: Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , ,

CAST IRON GATE VALVE WITH THREADED END DN25-50 PFA bar

INSTALLATION AND OPERATING MANUAL. TM Series Multi-stage Pump

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

Transcription:

ISO 9001:2008 Via Renata Bianchi, 12 16152 Genova ITALY Tel. +39.01.6017016 Fax. +39-010-601-6021 www.tecnidro.com s INDEX 1. Introduction 1.1 Premise 1.2 Generality 1.3 Principle of operation 2. INSTALLATION 3. START-UP 4. OPERATION 5. MAINTENANCE 6. GENERAL GUIDELINES

1. INTRODUCTION 1.1 Premise This guide describes how to install, use and maintain the IM-FD Series mod. 121-[xx] s manufactured by Tecnidro and cannot be applied to other models of valves. 1.2 Generality The IM-FD Series valves, manufactured in Italy by TECNIDRO, they are designed specifically for use with pressurized water or extinguishing foam in fixed fire suppression systems. The Series IM-FD valves ensure: - extreme facility of installation - sensible reduction of maintenance operations - long life in open field - excellent compromise quality/price The technical denomination of this line of valves is Diaphragm Automatic Hydraulic as: - the opening, the closing and the main flow regulation operate by means of the water in pressure available in the same pipe (for the manoeuvres do not require external energy sources); - the control and the regulation act automatically on the main flow by means of the hydraulic control circuits; - they modulate the flow by the movement of an elastic and waterproof closing element (diaphragm) that guarantees the total watertightness adapting to the valve seat. The diaphragm design and the high hydrodynamic profile of the iron body it confers to the product a greater water passage regarding other typologies of valves, which results in a sensible minimization of pressure losses. The closing by diaphragm offers a totally free section that does not constitutes obstacle to possible solid bodies that can obstruct the water passage. The internal and external valve surfaces are protected by a epoxy special polyester coating specific against corrosion. The basic valves bodies can be equipped with several control options to satisfy all operations conditions that are in fire suppression systems. TECNIDRO S.R.L. Installation, operation and maintenance Technical Manual - IM-FD 121-[xx] Pag. 2/8

1.3 Principle of operation valves operate by means of a very simple and efficient system of closing. In the valve interior three components are lodged only: the diaphragm, the spring and the support. The pressure of water is applied on the inner surface of the diaphragm, that is greater of its external surface that opposes to the flow. If the pressure into the control chamber (PC) is equal or higher than the upstream pressure (P1), the valve will close fully. As the pressure inside the chamber (PC) decreases, the diaphragm will open progressively until the total opening when the pressure arrives to zero. The spring force favours the beginning of the manoeuvre of closure and accompanies the diaphragm in the correct position avoiding vibrations. Control of pressure in the chamber is conferred to the hydraulic circuit that determines, according to its characteristics, the opening/closing (on-off functions) or the balance in intermediate opening positions (functions of adjustment of pressure and/or flow rate). IDROMEMBRANA valves must operate within a minimum and a maximum of working pressure. For the required limit values refer to the technical cards of individual models. TECNIDRO S.R.L. Installation, operation and maintenance Technical Manual - IM-FD 121-[xx] Pag. 3/8

2. INSTALLATION Before proceeding with the installation of the IM-FD valve mod. 121-[xx] is necessary to: - place the valve in rooms accessible to qualified personnel only or otherwise adequately protected from unwanted actions. - predict around the valve enough space to: access the local commands, make connections and hydraulic power lines necessary to the operation, maintenance or dismounting of the valve. - ensure that the pipelines are not under pressure or that they are adequately monitored; - prepare the connection fittings or the pipe flanges leaving enough space to insert the valve; the pipe connections must be perfectly and correctly oriented thrust compared to those of the valve, thus avoiding compression or traction conditions; - clean the upstream pipeline and remove any foreign objects that may interfere with the operation of the valve; then proceed to the installation of the valve having care of: - adopt appropriate individual protections; - lift the valve securing straps or ropes to the flanges or the valve body; even if you do not need the help of cranes or elevators, not to raise the valve for the hydraulic circuit or parts thereof; - avoid shocks or damage during handling that might compromise the tightness and the proper operation of the circuit; - place the valve ensuring that the flow arrow marked on the body or on the cover of that coincides with the direction of water flow; - achieve the tightness of connections (threads or flanges) using appropriate materials and equipment; an excessive tightening of the ends of the valve can cause rupture of the body or the damage of threads; - provide appropriate support firmly fixed to the wall or the ground to sustain the valve; - never make welds near of the valve when already installed; - achieve stable connections of electrical supplies and/or hydraulic command lines; do not disassemble or modify the hydraulic circuit to facilitate connection operations; - provision of drainage water collection that emerge during the service at the points (4) and (9); - protect the valve and hydraulic circuit from freezing or from exposure to excessively high temperatures. TECNIDRO S.R.L. Installation, operation and maintenance Technical Manual - IM-FD 121-[xx] Pag. 4/8

3. START-UP After installation, as described in the previous paragraph, proceed to the start-up operations as follows: - check that the valve (2) is in the open position (lever or butterfly parallel to the valve body) and that the valve (8) is closed (lever or butterfly orthogonal to the body); - drain the pressure gauge opening its sectioning valve (4), returning later in the loading position (lever on the side of power supply or release the button); - give the main pipe pressure and check that the upstream gauge (5) indicates the expected value; - intercept the downstream conduct, close the upstream on-off valve (2) and open the emergency manual valve (8): this manoeuvre will cause total drainage of the chamber in order to evacuate residual air which could impair the operation of the valve during exercise; - close the emergency manual valve (8), open the upstream on-off valve (2) and check on the pressure gauge (5) that the pressure is restored; - drain the downstream pipeline. Under these conditions the valve IM-FD is ready for service. 4. OPERATION The IM-FD mod. 121-[xx] valve is equipped with an hydraulic circuit that allows the following functons: - Electric Remote Actuation - Manual Local Actuation - Pressure Checking The individual functions are described below with the identification numbers of the main functional components, as listed in the corresponding flowchart. TECNIDRO S.R.L. Installation, operation and maintenance Technical Manual - IM-FD 121-[xx] Pag. 5/8

4.1 - Electric Remote Actuation The valve is equipped with a 2-way monostable type Solenoid Valve (7) that enables the remote control by an electronic control panel. The solenoid valve used in the mod. IM-FD 121-[xx] can be N.O. (normally open) or N.C. (normally closed) and may require different nominal voltage of power supply. Execution and the presence or absence of voltage to the coil of the solenoid valve determines the state of opening/closing of the IM-FD valve as follow: Model Power Supply Execution Valve Position IM-FD 121-[10] IM-FD 121-[11] IM-FD 121-[12] IM-FD 121-[13] 24V DC 24 V AC 110 V AC 220 V AC N.C. (Normally Closed solenoid) The valve opens when the solenoid is energized. IM-FD 121-[20] 24V DC N.O. IM-FD 121-[21] 24 V AC (Normally Open solenoid) The valve closes when IM-FD 121-[22] 110 V AC the solenoid is energized. IM-FD 121-[23] 220 V AC (NOTE: other tensions/executions are available on demand) The solenoid valves used in the models above are "monostable" type: the solenoid converts its position when activated and returns automatically to its original position when de-activated. A valve equipped with a N.C. type solenoid will remain open until the solenoid is energized and will close when the solenoid is de-energized. The opening/closing command must ensure that the remote solenoid receives sufficient power, as per characteristic of voltage normally specified on the coil. 4.2 Manual Local Actuation The hydraulic circuit that operates the IM-FD 121-[xx] valve is equipped with an Emergency Manual Valve (8) which allows to open the deluge valve in case of the electric remote actuation doesn't work correctly. The Emergency Valve is a manual 2-way ball valve predisposed for the plumbing in closed position to prevent accidental activation and highlight the tampering. Opening the Emergency Valve (8) causes the immediate opening of the deluge valve IM-FD 121- [xx]. Bringing back the Emergency Valve, the deluge valve IM-FD 121-[xx] closes slowly if the electric control is not enabled. TECNIDRO S.R.L. Installation, operation and maintenance Technical Manual - IM-FD 121-[xx] Pag. 6/8

4.3 Pressure Checking The IM-FD 121-[xx] valve is equipped with a Pressure Gauge (5) connected to the upstream pressure. Pressure gauge allows to check at any time the available pressure upstream the deluge valve, highlighting the state of opening/closing of the valve or the absence of the conditions of operation. The pressure gauge is equipped with an isolating valve (4), operable by lever or button, that allows the drainage of the instrument after pressure's checking in order to preserve its efficiency. 5. MAINTENANCE The IM-FD 121-[xx] valve ensures long life and safe operation without requiring expensive maintenance interventions. All maintenance operations must be carried out by specialised personnel and with the use of appropriate equipment. As A result of A maintenance operation involving disassembly circuit always proceed with the evacuation of residual air pockets the first filling, as described in Chapter 3. After each maintenance operation, involving disassembly circuit, the air trapped into the command chamber must be evacuated, as described in Chapter 3. 5.1 Protection strainer's cleaning The hydraulic circuit is equipped with a "Y" type Protection Strainer (3) act to protect the orifices from possible occlusion due to impurities present in the water. To proceed to strainer cleaning: - intercept the main pipeline downstream the valve; - close the on-off upstream valve (2); - release the filter plug up to generate a loss; - wait for the release of pressurized water and remove the plug; - extract the cartridge and remove the dirt retentions; - replace correctly the cartridge and the plug; - re-open the upstream on-off valve (2); - restore the pressure in the main pipeline. It is recommended to proceed to the cleaning of the strainer at least once a year, or more frequently if the water used is particularly dirty. TECNIDRO S.R.L. Installation, operation and maintenance Technical Manual - IM-FD 121-[xx] Pag. 7/8

5.2 Internal Parts Replacement (Diaphragm, Spring and Support) The closing system of IM-FD valve consists of a rubber diaphragm, a spring and a spring support, all housed within the valve cover and kept in position by the valve cover bolts. To proceed to the replacement is not necessary to disassemble the valve body from the main pipeline. To access the internal parts of the valve and to replace: - intercept the main pipeline upstream and downstream of the valve; - open the emergency valve (8) causing the drainage of the command chamber; - disconnect the hydraulic circuit and fittings which permit separation of cover from valve body; - unscrew the valve cover bolts progressively, moving into cross-sequence. While unscrewing, the cover should be restrained in strong position to work against the force of the spring which tends to raise it, avoiding the abrupt release; - remove the worn set of diaphragm, spring and support and replace it with original spare parts; - screw the bolts progressively and tightening in cross-sequence; - restore the hydraulic connections on the circuit and replace pipes and/or fittings if their watertight is compromised; - close the emergency valve (8) and restore pressure into the main pipeline. Replacing inner parts must be made in case of irregular operation of the valve. It is recommended however to proceed to the preventive replacement of internal components every 5 years or after a long out of service period. The consumption of the diaphragm can be accelerated by the presence of sand and/or aggressive chemicals dissolved into the water or in consequence of severe service conditions (pressure, flow and temperature). 5.3 Cleaning or Replacement of Functional Parts The hydraulic circuit is equipped with a Needle Valve (6) and a Solenoid Valve (7) whose holes can become clogged during the service due to sediment deposit not retained by the Strainer (3). During maintenance operations should be inspected and possibly clean up these components or replaced with original parts if excessively damaged. 6. GENERAL GUIDELINES The IDROMEMBRANA valves, as technical products for safety and protection systems, require that the installation, use, and maintenance are carried out by specialised personnel, using appropriated equipment suitable for the purpose. The hydraulic circuit is equipped with a needle valve (6) act to the adjustment of main valve closing time. This component comes from the factory already calibrated and leaded. The tampering of the security seal causes decay of guarantee on the product supplied. TECNIDRO S.R.L. is not liable for any damages generated to things and/or persons resulting from the alteration or tampering of its products, or improper use thereof. TECNIDRO S.R.L. Installation, operation and maintenance Technical Manual - IM-FD 121-[xx] Pag. 8/8