TMS Series MP46x Flex Probes* Installation Instructions

Similar documents
MP461SC Flex Probes* Installation Instructions

MP56xSA Flex Probes* Installation Instructions

FLEX PROBE INSTALLATION AND PROGRAMMING GUIDE

Dispenser Pan Sensors & Containment Sump Sensors

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Remote Sensor Kits. Installation Manual. Document No (Revision C)

Pneumatic Isolation Module

M V Flex Probe Installation Guide. Part Number: M V, Rev. 0. Issue D ate: September 24, 2015 Supersedes: N/A

LCD Annunciator Installation Instructions

7330 Pro-Stik II Magnetostrictive Level System

Dispenser Pan Sensors & Containment Sump Sensors

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Signet 2517 Brass Paddlewheel Flow Sensor * *

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Ultrasonic Two-Wire Point Level Control

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

MP-Series Integrated Gear Motors

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

M100F Incremental Motor Actuator R81F Interface Board

Lube Level Maintainer

PRO REMOTE Series CAPACITANCE PROBE

RF Point Level Control with Sensor Monitor

Woda-Sci System Installation Parts Set

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

TS Series TS Series

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER

ELECTRICAL INSTALLATION

Overhead Bus for Bulletin 2300 MCCs

Lube Level Maintainer

Snow Switch Models HSC 4 (P/N 24220) & HSC 5 (P/N 24221)

HBDBM High Bay Series

Manual No: Revision: F. Mag Probe Assembly Manual

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Installation Instructions Mineral Insulated (M.I.)

Power-Limiting Cables

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE

INSTALLATION INSTRUCTION

Operating Instructions

EL Beam Sensors Standard & SC Versions

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

MODEL 8631-CRM/8631-CRC PRESSURA CLEAN ROOM PRESSURE MONITOR/CONTROLLER

LS600 Liquid Level Float Switch Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

TIDALFLUX 2300 F Quick Start

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

High Bay Luminaire Series

ArchWeigh 2000 Conveyor Belt Scale Weigh Idler For Single or Multiple Scale Bases

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

LTX RF LEVEL SENSOR. Instruction Manual

E.S.P. Embedded Sensing Probes for Motor Brushes

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

PROVEX Installation Guide. Version 1.0

IMPORTANT ATTENTION INSTALLERS:

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

MODEL 8630 PRESSURA ROOM PRESSURE MONITOR

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

DURA-PANEL W OUTPUT: 12 VDC, 20 Watt W OUTPUT: 12 VDC, 50 Watt W OUTPUT: 12 VDC, 100 Watt

Temperature Transmitters

Carbon Canister Vapor Polisher

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

NEC 2011 Code Changes

MS Application. Features. Proportional Valve Actuator General Instructions

MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR

Installation and Operating Manual

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

MODEL 8635 SUREFLOW ROOM PRESSURE MONITOR

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

Immersion Temperature Sensors

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

CHILLED WATER CONNECTION CHECKLIST AND APPROVAL. Item Notes By Date Passivation Complete Flushing Complete Nitrate corrosion Residual value:

PRO REMOTE 25 LV CAPACITANCE PROBE

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Technical Manual. DLM Module. This manual should remain with the unit.

FOR OT/HT MODEL CHILLERS STYLE B AND C CONTROL CENTERS , AND

Low Profile Insertion Vortex

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

DC400 Dispensing Cutoff System

INSTALLATION INSTRUCTIONS Model FPT 50

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English

NTC Thermistor Assemblies

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

Rosemount 402 and 402VP

Installation GUIDE. 5 SERIES Professional Indoor Hoods EVWH53048, EVWH53648, EVWH54848

MODEL 8631-HM(-BAC)/8631-HC(-BAC) PRESSURA ROOM PRESSURE MONITOR/CONTROLLER

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

Installation Instructions

MODEL 8636 / 8636-LN / 8636-BAC SUREFLOW ROOM PRESSURE CONTROLLER

Quick Connection Panel (QCP) Installation Guide

Model 124 Filter Minder & Model 124

Installation Instruction

797V Piezoelectric Velocity Sensor

Manual No: Revision: F. TLS-450 Console. Site Prep and Installation Manual

Model DE-3 Air Release Heads Parts List

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

INSTALLATION INSTRUCTIONS

1100 Series Piston Type Differential Pressure Gauges

Transcription:

PNEUMERCATOR Liquid Level Control Systems TMS Series MP46x Flex Probes* Installation Instructions Model MP461, MP462 And MP463 Magnetostrictive Flex Probes Installation For: MODEL TMS2000 and MODEL TMS3000 * NOTE: BEFORE USING THIS BULLETIN, VERIFY MODEL NUMBER ON PROBE LABEL IS MP46x. "X" CAN BE NUMBER 1, 2, OR 3. TEL: (631) 293-8450 FAX: (631) 293-8533 PNEUMERCATOR TECHNICAL SUPPORT 1 (800) 209-7858 Page 1 of 8 4/12/2013 4:32:31 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

General System Overview: Figure 1 shows a block diagram of how the system should be configured for installation. It is supplied as a guide to planning the installation. DATA DISPLAY/ GATHERING & CONTROL EQUIPMENT TMS CONSOLE CONSOLE OUTPUTS MODEM/RS232/RS485/RELAY CONTACTS RELAY CONTACTS 120 VAC POWER SENSOR/PROBE INPUTS FROM OTHER TANKS REMOTE MOUNTED ALARMS FIELD WIRING: SEE PAGES 7 AND 8. LEVEL PROBE FIGURE 1. SYSTEM BLOCK DIAGRAM LIQUID STORAGE TANKS WARNING: THE TMS CONSOLE IS DESIGNED AND APPROVED TO SAFELY INTERFACE TO PROBES OR SENSORS LOCATED IN EXPLOSIVE ENVIRONMENTS WHEN INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ABSOLUTELY NO MODIFICATIONS ARE PERMITTED. USE ONLY THE PROVIDED CONDUIT ENTRIES, AND ONLY FOR THEIR DESIGNATED PURPOSES. ANY CONSOLE MODIFICATIONS SHALL ABSOLUTELY VOID ALL WARRANTIES, AND MAY RESULT IN PERSONAL INJURY OR PROPERTY LOSS. Page 2 of 8 4/12/2013 4:32:32 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

Applications: Flex Probes are designed for use in certain chemical applications, large vertical tanks or tanks that have a low ceiling clearance or other obstruction that prevents installation of a rigid probe. Product Description: The MP46x Series consists of (3) separate models, distinguished by the probe's overall length, as shown in table below. The probes are available with either (1) or (5) thermistors for optional temperature sensing and are supplied with (1) interface float and (1) product float for level control (May be supplied without interface float for additional gauging of tank bottom). MODEL NO. OAL (IN.) (Overall Length) BOTTOM CLEARANCE (IN.) BOTTOM DEADBAND DIMENSION (IN.) WEIGHT HEIGHT (IN.) HEIGHT (ABOVE TANK) FOR OPENING TYPES ON PAGE 5 MP461 151-216 2.00 6.00 4.25 MP462 MP463 SEE NOTE BELOW 217-288 289-480 481-600 2.00 3.00 4.00 6.00 8.00 9.00 4.25 6.25 7.25 12 INCHES MINIMUM SEE PAGE 6 1/2-14 NPT 3/4-14 NPT.62 DIA. FLEXIBLE KYNAR FLOAT GUIDE 12.00" PRODUCT FLOAT MAX. DIA. 3.85" P/N 170064-1 OPTIONAL FLOATS FOR 2" OPENINGS INTERFACE FLOAT PRODUCT FLOAT SPAN OAL INTERFACE FLOAT MAX. DIA. 3.85" P/N 170065-[ ] 316 STAIN. STEEL, MAX. DIA. 2.05" P/N 170067-[ ] 316 STAIN. STEEL, MAX. DIA. 2.05" P/N 170066-1 2.0" DIA. 316SS WEIGHT (SEE TABLE ABOVE FOR HEIGHT) BOTTOM CLEARANCE (SEE TABLE ABOVE) KEEPER PIN DEADBAND (SEE TABLE ABOVE) TANK BOTTOM COILED PROBE DO NOT UNWRAP Unpacking: DO NOT LIFT THE PROBE BY IT'S ELECTRICAL CABLE! Remove the probe and it's associated parts from the shipping crate(s) and inspect them for physical damage. IMPORTANT: DO NOT CUT THE TIE WRAPS AND UNCOIL THE PROBE! Advise PNEUMERCATOR and the shipping company immediately if any parts are missing or damaged. Consult the factory if you are not sure that the parts you received are suitable for your application. Page 3 of 8 4/12/2013 4:32:33 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

NOTE: Installation is only recommended with temperatures exceeding 40 F. For cooler temperatures, the probe needs to be warmed inside a building. This will help prevent tube cracks and probe damage during installation. WARNING: WHILE HANDLING THE PROBE AND DURING INSTALLATION, KEEP THE COILS PARALLEL! DO NOT LIFT ONE COIL SEPARATELY FROM THE OTHER COILS. DO NOT TWIST THE COILS. DO NOT BEND THE TOP 2 FEET OF THE PROBE. COILS PARALLEL COIL TWISTED NOTE: Installation must be done by 2 qualified personnel, familiar with local wiring codes and explosion hazard electrical practices. INSTALLATION: Without unwrapping it, carry the flex probe over your shoulder, and have the second installer carry the other components, to the top of the tank. 1. Confirm the OAL of the probe and bottom clearance against your mounting height. The probes OAL can be found on the yellow tag attached to the probe. It is the last 3 digits of the catalog number after the "L". example" 7100K182T1XF2L202. From the table on page 3, note the required bottom clearance and mounting height. Select nipple length to achieve the required mounting height and bottom clearance. 2. Keeping the probe over your shoulder, have the second installer cut ONLY the tie wrap at the end of the tube with a hole through it, marked #1. 3. Install the appropriate equipment on the end of the probe in the order (6-10) and orientation shown on the preceding page, making sure to support the end of the probe to keep it from twisting. 4. With the probe still coiled and resting on your shoulder, carefully feed through the tank opening, cutting the tie wraps only when necessary. They have been sequentially marked in the order that they must be cut. THE TOP 2 FEET OF THE PROBE HAS ELECTRONIC COMPONENTS MOUNTED INSIDE. DO NOT BEND THE TOP 2 FEET OF THE PROBE. 5. Before you screw the mounting fitting (nipple, coupling and bushing) in, verify that the weight will not hit the bottom of the tank when the probe is mounted. 6. Screw the mounting fitting into the threaded tank opening, the tank fitting or secure the flange. 2' Do Not Bend TANK TOP Page 4 of 8 4/12/2013 4:32:35 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

PARTS NECESSARY FOR INSTALLATION NOTE: TANK OPENING SHOULD BE THE SAME AS OR GREATER THAN FLOAT SIZE. PROBE MOUNTING LOCATION SHOULD BE SELECTED TO MINIMIZE EFFECT FROM TURBULENCE. HOUSING (SUPPLIED) SEE PAGE 6 FOR OTHER RECOMMENDED HOUSINGS SEE TYPICAL WIRING FOR PROBE ON PAGE 7 CONDUIT AND VAPOR SEAL FITTING PROVIDED BY INSTALLER 1/2" NPT 1 BLACK WHITE BLACK RED TO CONSOLE 3/4" NPT 1/2" NPT BOTH ENDS OR AS REQ'D KYNAR FLOAT GUIDE WITH FITTING (GUIDE PARTIALLY SHOWN) 2 WARNING! HAND TIGHTEN HOUSING WHILE SECURING HEX NUT OF PROBE SHAFT. DO NOT BEND OR STRAIN SHAFT WHEN CONNECTING CONDUIT. STANDARD 2" THREADED OPENING FITTING/BUSHING WITH 2" THREADED OPENING FLANGE WITH 2" THREADED OPENING 3 2" X 3/4" BUSHING 3 3 4 5 2" COUPLING NIPPLE, 2" NPT BOTH ENDS (SEE PAGE 6 FOR NIPPLE LENGTH) MOUNTING FITTING (METAL) 4 5 BUSHING FLANGE 4 5 6 6 2" FLOATS 2" FLOATS OR 4" FLOATS 6 PRODUCT FLOAT 7 PRODUCT FLOAT 7 7 INTERFACE FLOAT (OPTIONAL) 8 INTERFACE FLOAT (OPTIONAL) 8 8 WEIGHT 9 WEIGHT 9 9 KEEPER PIN 10 KEEPER PIN 10 Page 5 of 8 4/12/2013 4:32:37 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

CALCULATING NIPPLE LENGTH MOUNTING HEIGHT EQUAL TO TANK HEIGHT (MH = TH) MOUNTING HEIGHT GREATER THAN TANK HEIGHT (MH > TH) 1.25" 5" SEE NOTE 1 12" MIN NL NL H TOP OF TANK FORMULA (ALL MEASUREMENT IN INCHES) : NL = OAL - MH + BC - 4 WHERE: NL = NIPPLE LENGTH OAL = PROBE OVERALL LENGTH (SEE PROBE LABEL) MH = TANK MOUNTING HEIGHT MEASURED FROM INNER BOTTOM TO TOP OF THREADED OPENING OR TH + H. TH = TANK HEIGHT MEASURED FROM INNER BOTTOM TO TANK ROOF. H = THE HEIGHT FROM TOP OF TANK TO WHERE NIPPLE WILL BE INSTALLED. BC = PROBE BOTTOM CLEARANCE FROM TABLE ON PAGE 3. NOTE: 1. THIS DIMENSION IS 5" WHEN STANDARD METAL 2" X 3/4" BUSHING (TYPICALLY 1 3/8" OVERALL HT) AND 2" COUPLING (TYPICALLY 2 1/2" OVERALL HT) IS USE IN MOUNTING ASSEMBLY. NIPPLE LENGTH CALCULATION EXAMPLE 1: OAL (from probe label) = 419" MH = 403" BC (from table on page 3) = 3" NL = 419-403 + 3-4 = 15" OTHER RECOMMENDED WATERTIGHT RATED HOUSINGS NIPPLE LENGTH CALCULATION EXAMPLE 2: OAL (from probe label) = 537" TH = 512" H = 5" BC (from table on page 3) = 4" MH = 512 + 5 = 517" NL = 537-517 + 4-4 = 20" 1/2" NPT OR AS REQ'D TYP Page 6 of 8 4/12/2013 4:32:39 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

Wiring: Intrinsically Safe Input wiring: Wire and install in accordance with Article 504 of National Electric Code ANSI/NFPA 70. Non-Intrinsically Safe Wiring can not be run in conduit or open raceways together with intrinsically safe wiring. TMS CONSOLE INTRINSICALLY SAFE WIRING COMPARTMENT 1" NPT FITTING (TMS3000) 3/4" NPT FITTING (TMS2000) NON-HAZARDOUS AREA HAZARDOUS AREA CLASS I, GROUPS C,D NON-INTRINSICALLY SAFE WIRING INTRINSICALLY SAFE WIRING VAPOR SEAL (AS REQ'D). PROBE CABLE CABLE SELECTION: Use Belden 8441, or Alpha 1736C or any equivalent 2-conductor, 22 awg shielded, twisted-pair cable, refer to TMS installation manual for more cable selection information. The shield wire must be connected to the PROBE SHIELD TERMINAL in the console I.S. compartment and terminate at the junction box, where it must be isolated. (See probe wiring below) JUNCTION BOX (SEE PROBE WIRING). TANK PROBE TYPICAL WIRING FOR PROBE NOTE: WIRING MUST BE DONE IN WATERTIGHT RATED BOX/HOUSING. PROBE CABLE BLACK WHITE BLACK RED WIRE NUTS TO CONSOLE SEAL WIRE SPLICES AND CABLE * SHEATH ENDS WITH SUITABLE WATERPROOFING SEALANT; OR USE ENCLOSED EPOXY SPLICE KIT PCO PART NUMBER 10518-2. WARNING! DO NOT BEND OR STRAIN MOUNTED HOUSING WHEN CONNECTING CONDUIT OR AT ANY OTHER TIME. SHIELD WIRE HAS NO CONNECTION. SNIP AND ISOLATE WITH WIRE NUT AND OR ELECTRICAL TAPE. Page 7 of 8 4/12/2013 4:32:40 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

Wiring continued: TYPICAL WIRING FOR TMS CONSOLES PROBE 1 RED +V BLK GND SHD SHIELD +V GND SHIELD PROBE 2 P RED C R O BLK H B E A SHD N S N N E 1 E S L O R S 2 1 +V GND SHD GND SIG +V +V TMS2000 PROBE INPUT WIRING TMS3000 PROBE INPUT WIRING Programming: Information necessary for programming this probe can be found on the tag attached to the probe. One side of the tag has certification information and the other side has information needed to program the TMS console to enable this probe. Copy the information from the tag on the probe onto this sheet and onto the tank worksheet in the TMS Operation Manual for referencing when programming the TMS. If you have more than 6 probes, make a copy of this sheet. Page 8 of 8 4/12/2013 4:32:41 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.