Digital Print-out Test Kit for Backflow Preventer Assemblies

Similar documents
Series 990/990RPDA. Reduced Pressure Zone Backflow Preventer. Sizes: 4", 6", 8" (100mm, 150mm, 200mm)

Installation, Maintenance, & Repair Series 919 and LF919

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

Series 007. Double Check Valve Assembly. Installation Service Repair Kits Maintenance. Sizes: 1 2" 3" Watts 3 4" 007M3QT RP/IS-007

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Colt Series C400, C500

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Series 867 Reduced Pressure Zone Assemblies

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

THIS WARRANTY IS IN LIEU

Installation, Maintenance, & Repair Series 4000CIV

Series 995/995RPDA. Sizes: 3" - 6" Reduced Pressure Zone Backflow Preventer/ Reduced Pressure Detector Assemblies RP/IS-995/995RPDA

Maintenance Manual Double Check and Double Check Detector Assemblies Series 850, 856, 870V & 876V 2 1 /2" - 10" (65 250mm)

Series 009. Reduced Pressure Zone Assemblies. Installation Service Repair Kits Maintenance. Sizes: 8 80mm. 80mm 009LF RP/IS-009-AUS

Installation, Maintenance, & Repair Series 909, LF909, 909RPDA, LF909RPDA Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies

Installation, Operation and Maintenance Manual

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Installation, Operation and Maintenance Manual

Price List. Backfl ow Prevention Products, Repair Kits, and Parts. Effective July 2, AmesFireWater.com 2018 AMES FIRE & WATERWORKS PRICE LIST

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016

INSTALLATION & MAINTENANCE MODEL mm

Cash-Flo. Operation & Maintenance Manual. BackFLOW PREVENTERS. A Division of the Reliance Worldwide Corporation

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Sanitary Yard Hydrant Installation Instructions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

Installation Instructions

AMES 2013 Price List. Backflow Prevention Products. Effective April 1, 2013

Sanitary Roof Hydrant Installation Instructions

Straight-Bore Clutch LSCC-32, 44, 54

Price List. Backflow Prevention Products and Repair Kits. Effective Date October 30, FEBCOonline.com 2017 FEBCO PRICE LIST

Price List. Backflow Prevention Products and Repair Kits. Effective Date July 2, FEBCOonline.com 2018 FEBCO PRICE LIST

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

BFMM DC4A SBF EFFECTIVE AUGUST 1, 2016

HR-20P Pneumatically Controlled Pressure Regulator

Installation, Operation, and Maintenance Manual Series LFF113FP Wireless Smart Universal Flood Protection ACV System with SentryPlus Alert Technology

AMES 2015 Price List. Backflow Prevention Repair Kits and Parts. Effective March 30, Includes Our. Product Offering.

JET METER INSTRUCTIONS

Agxcel GX12i Chemical Injection System

Caution. Do not operate your Micro Rain traveler without a serious overview of this manual. Keep children and unauthorized people away from traveler

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

2 ½ 12. Model RP 4A Model RPDA 4A Model RPDA2 4A. Installation, Operation, and Maintenance Manual

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

i n s t r u c t i o n m a n u a l

CV Control Valves Installation and Operation Manual

FOR TECHNICAL ASSISTANCE

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

ESE Series Cast Iron Sewage Pumps

2 ½ 12. Installation, Operation, and Maintenance Manual. Reduced Pressure Principle Backflow Preventer. Reduced Pressure Detector Assembly

Wahoo Limited Warranty

MODEL 900 IMPELLER-TYPE FLOW METER

INSTALLATION AND OPERATION MANUAL

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

TBM Series 3-Way Ball Valve

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Model 1100 Turbine Flow Meter

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

PT-516 Pumping Trap Installation and Maintenance

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

EchoPod. Technical Support. Model: DL14-(XX) Quick Start

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

HALLMARK INDUSTRIES INC

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

Single Post Caliper Brake VC500

INSTRUCTION MANUAL. Model 7001 Battery Operated Irrigation Controller with Hose or Pipe Thread

DeZURIK 2 20" BOS BUTTERFLY VALVES

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

Installation and Maintenance Instructions

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Flow Control Valve IOM 770-U

Backflow Irrigation Control Station BIC-1000

systems company Operating Manual - Adjustable Lower End Model 0.2% - 2% WSP Model 0.78% - 5% WSP

FOR TECHNICAL ASSISTANCE

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

DAP-625S and DAP-875S

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Power. On Your Terms.

10 Year Limited Warranty

MODEL 200 MULTI-JET FLOW METER

FCB-450, LCB-600, MCB-800

Manual Concentrate Management System

Transcription:

Watts TK-DL Digital Print-out Test Kit for Backflow Preventer Assemblies IS-TK-DL Watts TK-DL (in carrying case - sold separately) Watts TK-DL Installation The Watts TK-DL Computerized Backflow Tester is an advanced piece of test equipment designed to make pressure and differential gauges obsolete in the testing of backfl ow assemblies. Two solid-state, high-resolution pressure transducers provide the interface to the computer. With 32K of memory, battery back up, 48 character super-twist display, 6 function keyboard and high-effi ciency thermal printer, the TK-DL is equipped to provide real time data handling and the outputs required to test, validate and certify every backfl ow assembly. (See operating manual for details). The TK-DL allows you to download your test results into a personal computer for permanent storage. In addition, the TK-DL menu driven software program allows for customizing of printed header and footer. GENERAL INFORMATION Before connecting hoses to tester, be sure to flush test cocks on backflow assembly. CAUTION: To avoid freeze damage to the test kit, it should be stored in a dry warm area when not in use. Limited Warranty: Watts Regulator Co. (the Company ) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge. THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product. Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

Test Procedure for Pressure Vacuum Breakers The following Test Procedure is one of several that is recognized throughout the United States for verifi cation of the functioning of Backfl ow preventers. The following procedure is not a specifi c recommendation. The Watts series of test kits are capable of performing any of the recognized Backfl ow test procedures. Note: For both of the following test, the TK-DL must be held at the same level as the assembly being tested. A. Flush TC # and #2. B. Turn tester on (before connecting hose). Tester must read all zeros. Close VA and VB. Test No. - Air Inlet. Install high side hose between TC #2 and tester connection A. 2. Open VA then TC #2. Bleed hose, then close VA. 3. Close shutoff valve #2 then #. Push - Print Head (wait) then Push - Start Test 4. Slowly open VA when air inlet fl oat opens, push hold button for at least 2 seconds. Record differential reading (must be PSID or more). Close VA. Push - Stop Test 5. Close TC #2 and remove hose. 6. Open shutoff valve #. Test Cock No. 2 Test No. 2 - Test Check Valve 7. Install highside hose between TC # and tester connection A. 8. Open VA then TC #. Bleed hose, then close VA. 9. Close shutoff valve #. Push - Start Test 0. Open TC #2. When fl ow of water out of TC #2 stops, the differential reading is the pressure drop. Record (must be PSID or more). Stop Test (Push Stop Test twice). Close test cocks and remove tester. Return assembly to normal operating condition. Test Cock No. 800M4-QT 2

Test Procedure for Anti-spill, Anti-siphon Vacuum Breaker (SVB) Test No. - Differential Test Make sure that the test kit is at the same elevation as the device being tested.. Remove the two screws from hood and remove hood so that vent is visible. 2. Turn test kit on, wait until self check is complete. 3. Connect hose from test cock to VA HIGH. 4. Open test cock, then VA, (VB LOW should be opened and remain open through the test). Bleed hose and test kit of air, when bleeding hose fi ll vent with water, shut off VA. 5. Close #2 shutoff, then close # shutoff. 6. Press PRINT HEADER button. Wait until header stops printing. Press START TEST RESUME button. 7. Slowly unscrew bleed screw on SVB (about three turns). 8. When dripping from bleed screw stops, and gauge reading settles, this is the check differential. This must be PSI or greater. 9. Press PAUSE STOP button. Test No. 2 - Air Inlet (Vent Opening) 0. Press START TEST RESUME.. Slowly open VA and watch vent, with fi nger over DISPLAY HOLD button. When the water level above the vent starts to drop this is the vent opening press DISPLAY HOLD button. This will record the vent opening point. This value must be PSI or greater. 2. Visually inspect vent to ensure that vent goes to full open position when the pressure is at zero. 3. Press PAUSE STOP TEST button twice. 4. Tighten bleed screw, close test cock and reinstall hood, open shutoff #, open shutoff #2, remove hose. Testing is complete. 008QT Bleed Screw Test Cock 3

Test Procedure for Anti-spill, Anti-siphon Vacuum Breaker (SVB) The following Test Procedure is one of several that is recognized throughout the United States for verifi cation of the functioning of Backfl ow preventers. The following procedure is not a specifi c recommendation. The Watts series of test kits are capable of performing any of the recognized Backfl ow test procedures. A. Flush all test cocks. B. Turn tester on (before connecting hoses). Tester must read all zeroes. Close VA and VB. Test No. - Test No. Check Valve. Install high side hose between TC #2 and tester connection A. 2. Install low side hose between TC #3 and tester connection B. 3. Open VA then TC #2, bleed hose, then close VA. 4. Open VB then TC #3, bleed hose, then close VB. 5. Install a bypass hose between VB and TC #. Open TC # and bleed by loosening hose connection at VB. Tighten hose connection, fully open VB. Push - Print Head (wait) then Push - Start Test. 6. Close shutoff valve #2 then #. 7. Slowly open VA and lower high side pressure about -2 PSID below the low side pressure (differential reading about -2.0 PSID). Close VA. If reading is maintained, record as tight. If reading returns to 0 and the pressure A increases to pressure B, the check is recorded as leaking. If the reading returns to +PSID, No. 2 shutoff valve is leaking excessively and must be replaced to test the valve. 8. Close all test cocks, remove hoses from TC #2 and TC #3 and TC #. reopen shutoff valve #. Proceed to Test No. 2. Push - Stop Test. Test No. 2 - Test No. 2 Check Valve. Install high side hose between TC #3 and tester connection A. 2. Install low side hose between TC #4 and tester connection B. 3. Open VA then TC #3, bleed hose, then close VA. 4. Open VB then TC #4, bleed hose, then close VB. 5. Install a bypass hose between VB and TC #. Loosen hose at VB, open TC # and bleed, retighten hose connection. Push - Start Test. 6. Close shutoff valve #. 7. Slowly open VA and lower high side pressure about -2 PSID below the low side pressure (differential reading about -2.0 PSID). Close VA. If reading is maintained, record as tight. If reading returns to 0 and the pressure A increases to pressure B, the check is recorded as leaking. If the reading returns to + PSID, No. 2 shutoff valve is leaking excessively and must be replaced to test the valve. Push - Stop Test. V H L V V HL V 2 3 4 2 3 4 4

Test Procedure for Reduced Pressure Zone Assemblies The following Test Procedure is one of several that is recognized throughout the United States for verifi cation of the functioning of Backfl ow preventers. The following procedure is not a specifi c recommendation. The Watts series of test kits are capable of performing any of the recognized Backfl ow test procedures. A. Open TC #4 and fl ush test cocks Nos., 2 and 3 on BF assembly, then close TC #4. B. Turn tester on (before connecting hoses). Tester must read all zeros. Close VA and VB. Test No. - Relief Valve. Install high side hose between TC #2 and tester connection A. 2. Install low side hose between TC #3 and tester connection B. 3. Open VB then TC #3. Now open VA then TC #2 slowly. Close VA then VB. 4. Close #2 shutoff valve. 5. Observe the apparent fi rst check valve differential pressure (A - B). 6. Install bypass hose between VA and VB. Open VB and bleed air by loosening hose connection at VA. Tighten hose connection and close VB. Push - Print Head (wait) then Push - Start Test 7. Open VA, then slowly open VB (no more than 4 turn). When relief valve drips, push the hold button for 2 seconds. Record reading (must be 2 PSID or more). Push - Stop Test 8. Close VA and VB. Test No. 2 - Test No. 2 Check Valve 9. Install bypass hose between VA and TC #4. Open VA, then bleed air by loosening hose connection at TC #4. Tighten hose connection. Close VA. Push - Start Test 0. Open VB to reestablish pressure within the zone. Close VB.. Open VA the TC #4. If relief valve does not drip, record second check valve as closed tight. 2. Close VA and TC #4 and remove bypass hose. Test No. 3 - Test No. Check Valve 3. Open VB to reestablish fi rst check valve differential pressure. Close VB. Record pressure differential. Stop Test (Push Stop Test twice) 4. Close test cocks and remove tester, return assembly to normal operating condition. V H L V 3 4 2 V H L V 2 3 4 V H L V 3 4 2 5

Calibration Centers Nicholson Labs 423 Queen City Ave. Cincinnati, OH 4524 Tel: (53) 25-8378 Fax: (53) 25-4388 BAVCO 20435 S. Susana Road Long Beach, CA 9080-36 Tel: (30) 639-523 Fax: (30) 639-072 Troubleshooting Guide Double Check Valve Assemblies SYMPTOM CAUSE SOLUTION. Check valve fails to hold a. Debris on check disc Disassemble and clean.0 PSID minimum sealing surface b. Leaking gate valve Disassemble and clean or repair c. Damaged seat disc or Disassemble and replace seat o-ring d. Damaged guide holding Disassemble clean or replace check open e. Weak or broken spring Disassemble and replace spring 2. Chatter during fl ow a. Worn, damaged or Disassemble and repair or conditions defective guide replace guide 3. Low fl ows passing a. Mainline check fouled Disassemble and clean through mainline valve (709DCDA only) b. Meter strainer plugged Disassemble and clean c. Damaged mainline seat Disassemble and replace disc or seat d. Broken mainline spring Disassemble and replace 6

Troubleshooting Guide Reduced Pressure Zone Assemblies Should valve PROBLEM CAUSE be replaced? SOLUTION A. Valve spits periodically from the vent. A. Fluctuating supply pressure. No A. Install a soft seated check valve immediately upstream of the device. (Watts 3/4-2 No. 60 bronze valve.) A.2 Fluctuating downstream pressure. No A.2 Install a soft seated check valve downstream of the device close as possible to the shutoff valve. (Watts 3/4-2 No. 60 bronze valve.) B. Valve drips continually from the vent. B. Fouled fi rst check. No B. Flush valve. If fl ushing does not resolve problem, disassemble valve and clean or replace the fi rst check. B.2 Damaged or fouled relief valve seat. No B.2 Clean or replace the relief valve seat. B.3 Relief valve piston O ring not free to move due to No B.3 Clean, grease or replace the piston O ring. pipe scale, dirt or build-up of mineral deposits. B.4 Excessive backpressure, freezing, or water hammer No B.4 Eliminate source of excessive backpressure or water has distorted the second check. hammer in the system downstream of the device. Use Watts No. 60 to dampen out backpressure and No. 5 to eliminate water hammer. Replace defective second check assembly. In case of freezing; thaw, disassemble, and inspect internal components. Replace as necessary. B.5 Electrolysis of relief valve seat or fi rst check seats. No B.5 Replace relief valve seat or inlet cover. Install dielectric unions (Watts Series 300 through 3006). Electrically ground the piping system and/or electrically isolate the device with plastic pipe immediately upstream and downstream of the device. B.6 Valve improperly reassembled. No B.6 If valve is diassembled during installation, caution must be exercised to install check springs in their proper location. C. Valve exhibits high pressure drop. C. Fouled strainer. No C. Clean strainer element or replace. C.2 Valve too small for fl ows encountered. Yes C.2 Install proper size device based upon fl ow requirements. D. No water fl ows downstream of valve. D. Valve installed backwards. No D. Install valve in accordance with fl ow direction arrow. E. Valve does not test properly. E. Follow manufacturer s test procedure. No E., E.2 Clean or replace gate valve with full port ball E.2 Leaky downstream gate valve. No valves or resilient wedge shutoff valves. F. Valve quickly and repeatedly fouls following servicing. F. Debris in pipe line is too fi ne to be trapped by strainer. No F. Install fi ner mesh strainer element in the strainer. G. Winterization of backfl ow preventers. G. Electric heat-tape wrap closely together around valve body. Build a small shelter around the valve with a large light bulb installed and left on at all times. If supply line is not used during the winter, removal of the complete body is the best. This would create an air gap to eliminate any possible backfl ow. 7

Watts TK-DL Software Instructions The Watts TKDLC02 Software Disc is menu driven and will prompt you throughout the process of down loading your Watts TK-DL test results to a personal computer. The following information has been provided to assist you in utilizing your Watts TK-DL test kit. TK DLC 02: Enter READ WRITE TO TESTER: Enter Connect TK-DL to computer and turn on (on screen instructions) A. Load Data from Tester Reads Tester information in memory. B. Display settings Model = Watts TK-DL Eprom Version Serial # Time/Date Last Calibrated Next Cal Due Next Test # C. Change Settings Time/Date - day only D. Display Heading and Footer Displays heading and footer in TK-DL memory printed on tape. E. Change Heading and Footer Allows heading and footer to be changed by using computer keyboard. F. Write Data to Tester (Saves information to the Test Kit once you have changed the header or the footer or anything in the Change Settings option). G. Load Heading File It recalls a heading that was previously saved. You can then load into the TK-DL when you are connected to the computer. After loading you must write data to tester (Step F). H. Load Footing File Same as load heading, except for footer. G., H. Brings up headers and footers that were programmed and saved at an earlier time. You may recall the footer or header to program into you test kit. The recalled or Loaded information will overwrite current information. I. Save Heading J. Save Footing I, J, Use this option when you have changed the header or the footer and want to save the changes. You can save each header and footer in a separate file. You can then recall or Load the header or footer to be programmed into your test kit. K. Down Load Tests Down loads from TK-DL to disc. L. Print Tests On screen prompts: F2 OK, F4 scroll up, F6 scroll on, Esc to cancel. Lists date and Time tests were recorded. to select test to print Note: The disc included with your test kit allows you to change your header or footer. Therefore, the disc should not be carried in the test kit case. Backflow Prevention Products USA: 85 Chestnut St., No. Andover, MA 0845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca IS-TK-DL 0829 EDP# 90763 Watts, 2008