USER MANUAL 2AMDI584IPDBS

Similar documents
enerbox Pannello di controllo per 2 pompe (optional) Control panel for 2 pumps (optional) Pannello di controllo standard Standard control panel

INVERTER TRIFASE HEAVY DUTY

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

ABB i-bus KNX DG/S x DALI-Gateway Basic

Quick Reference Guide. English EN Español ES Français FR Nederlands NL

Incassi a parete - Recessed wall-mounted luminaires THUNDER110. arcluce.it. thunder

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

ISTRUZIONI DI MONTAGGIO / MOUNTING INSTRUCTIONS

TECHNICAL DESCRIPTION

Servomotori Brushless serie BT2 tensioni 230 e 400 Vac coppie nominali da 2,2 a 7,5 Nm

BOX A3 TEST R. Bocconi. REL. DATE R.T. Check and Approval

Phoenix Inverter

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Application book Construction and Agricultural machines. Ultrasonic & Inductive Sensors. Ultrasonic & Proximity Sensors

Amperis battery regenerator

GTS 15/25/40/50/60/75/90/120A

ATTENTION. Magic Zone Bluetooth Command Remote Installation Instructions

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

DURATAPE TM RGB IP20 INDOOR

REV lubrication systems PEGPEO Electropumps for progressive systems

DURATAPE TM RGB IP66 OUTDOOR

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Transformers for Low-voltage Halogen Incandescent Lamps

Wind display type WSDI-2

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

TPART 1 PRODUCT SPECIFICATIONS...1.

Emergency lighting units EM series

CB Type Intelligent Battery Chargers

Moduli LED LED modules

TWIGGY T1, TUBULAR 1" LENS TUNABLE WHITE 24VDC SYSTEM, 90+CRI

DELTA i-system. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/13 Shutter/blind controls. 1/19 Socket outlets

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type>

T P M S. Multi Wheel Bluetooth. Tire Pressure Monitoring System. User Manual. Model: External

Aurora Single Phase Emergency Lighting Inverters

Please Read Over This Manual Before Operating The Light Fixture

HIGH POWER SOLENOID DRIVER 1

L300P Inverter Specifications

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External

DURATAPE TM RGBW IP20 INDOOR

R 159. Duty cycle. ED 100%; ED 60%(90 C) Direzione del fluido Unidirezionale Flow direction Unidirectional Diametro di passaggio DN 8 mm.

Table of Contents. Product Registration 18 FAQ 19 Troubleshooting 20 Customer Support / Warranty 21

HOT MELT RESIN MOLDING TECHNOLOGIES SYSTEM'S STRUCTURE

Frequently Asked Questions

MP8000 BLUETOOTH OVERLOAD RELAY FAQ

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Max Load. Max. Load. 100W 3-50VDC mA > 90% < 20% > 0.95 RFID P/N: XXXXXXXXXX CERTIFIED TO CSA STD. C22.2 NO.

GS2 Series - Introduction

COOLEDGE TILE TUNABLE WHITE - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

Air Lift Performance 3S

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

ASYN205B Central Synchronizing Controller

3-phase motors Vector-Speed Synchronous motors

Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual

Oil/Air Cooler Units Standard series - Accessories

POW72V35A/BMS CHARGER SPECIFICATION

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

VA R I A B L E S P E E D D RIVE NANO

D R C- 4 0 s e r i e s

J1000. Compact Inverter Series.

Emergency lighting units EM powerled

Daymak Drive Application ios. User Guide

Digital Time Switches

CIRRUS CEILING SQUARE 1 WITH REMOTE POWER

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Fig.306F (DN50-150) Pressure Independent Control Valve (PICV)

MY ENERGICA Reference guide

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications

CB Type Intelligent Battery Chargers

Continental Hydraulics Installation Manual CEM-AA-A

Emergency lighting units PC COMBO

EcoSystem Multiple Control Input Ballasts

BT1S. DATI MOTORE Motor ratings. Cat.gen.ed.SEP12.rev.A. SERIE Series. Symbols UNITÀ SIMBOLI. Units. COPPIA Torque Nm 0,5

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

BT3M. DATI MOTORE Motor ratings. Cat.gen.ed.SEP12.rev.A. SERIE Series. Symbols UNITÀ SIMBOLI. Units. COPPIA Torque Nm 12,5

OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications

Apparecchi da incasso a soffitto - Recessed downlights QUANTUM130. arcluce.it. quantum

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

BIDIRECTIONAL DC/DC CONVERTER

EcoSystem Multiple Control Input Ballasts

Installation Instructions MX LED Enhanced Color Adjustable

EGT-100 Operations and Installation Manual

All In one uninterruptible power supply solutions

Entrematic SBU-BBU20-BBU65

CIRRUS SUSPENSION WITH RECTANGULAR 1 LENS WITH REMOTE POWER, END FEED

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

FAIL-SAFE CONTROL VALVES. Fast Electrically Actuated Control Valves

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

User Manual WatchPower App

VASCO. Variable Speed Controller ENGLISH

HomeWorks QS RF C L Hybrid seetouch Keypads

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

Model Number AC-50CD1.4APNZ AC-50CD1.4APBNZ

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

EcoSystemR Multiple Control Input Ballasts

Safety Control HR1S-AC. Safety Relay HR1S-AC

Positive displacement batch controller

Transcription:

USER MANUAL 2AMDI584IPDBS SUBJECT INDEX: DESCRIPTION TECHNICAL SPECIFICATION DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE OPERATION MODES PUSH MODE WHITE TUNABLE + BLUETOOTH (DEFAULT) PUSH MODE 2 SEPARATED CHANNELS + BLUETOOTH DALI MODE 2 CHANNELS BLUETOOTH CONTROL PARAMETERS CONFIGURATION Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 1

DIMMER DUE CANALI MULTIPROTOCOLLO C.C. Bluetooth IoT Light DUAL CHANNELS MULTIPROTOCOL DIMMER C.C. Bluetooth IoT Light CARATTERISTICHE TECNICHE TECHNICAL NOTES - Dimmer due canali con Uscita in Corrente PWM. - Range di alimentazione: 8-53V DC. - Uscita in Corrente PWM con corrente da 170mA a 1050mA (54,6W a 52VDC per canale). - Controllabile tramite app Android/iOS IOT LIGHT. - Ingressi di Controllo: Pulsante isolato x2, DALI x1, Bluetooth LE x1. - Circuito Stampato UL. - Classe di protezione: IP20. - Dimensioni Standard 40x80x24.45 mm. - Dimensioni con Accessori 40x100x24.45 mm. - Protezione da inversione di polarità. - Protezione circuito aperto. - Protezione da picchi tensione. - Protezione da sovratemperatura. - Protezione corto circuito. PULSANTE N/O ISOLATO N/O insulated switch - Dual channels Dimmers with Output Current PWM. - Input Range: 8-53V DC. - Output Current PWM with current from 170mA a 1050mA (54,6W at 52VDC each channel). - Controllable with Android/iOS app IOT LIGHT. - Input Controls: Insulated Push button x2, DALI x1, Bluetooth LE x1. - Printed Circuit UL. - Protection Class: IP20. - Standard Dimension 40x80x24.45 mm. - Dimension with accessories 40x100x24.45 mm. - Reverse polarity protection. - Open circuit protection. - Surge voltage protection. - Over temperature protection. - Short circuit protection. INGRESSI DI CONTROLLO - CONTROL INPUTS DALI 0-10V;1-10V PULSANTE NO (isolato) PUSH NO (INSULATED) Bluetooth LE POTENZIOMETRO LINEARE 100K Linear Potentiometer X1 - X2 X1 - CORRENTE MAX IN USCITA (*) MAX OUTPUT CURRENT Da 170mA a 1050mA / From 170mA to 1050mA Dimmer due canali con Uscita in Corrente PWM. Range di alimentazione: 8-53V DC. Uscita in Corrente PWM con corrente da 170mA a 1050mA (54.6W a 52V DC per canale). Controllabile tramite app Android/iOS IOT LIGHT. Per impostare le correnti di uscita occorre dotarsi di interfaccia 2AMIN4030000N venduta separatamente. Corrente di default 350mA. Per impostare il fade e la curva logaritmica/lineare di uscita occorre dotarsi di interfaccia 2AMIN4030000N venduta separatamente, le modalità di funzionamento vengono riconosciute e impostate automaticamente dal dispositivo senza bisogno di interfaccia esterna. Vedi manuale d uso. dual channels Dimmers with Output Current PWM. Input Range: 8-53V DC. Output Current PWM with current from 170mA a 1050mA (54.6W at 52V DC each channel). Controllable with Android/iOS app IOT LIGHT. In order to set the output current you will need the 2AMIN4030000N interface sold separately. Default current 350mA. In order to set the fade output and the logarithmic or linear output you will need the 2AMIN4030000N interface sold separately, the other working modes are automatically detected by the device. Please refer to user manual. Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 2

CODICE CODE TENSIONE IN INGRESSO INPUT VOLTAGE CORRENTE USCITA (MAX) (MAX) OUTPUT CURRENT n. CANALI IN USCITA n. OUTPUT CHANNELS POTENZA MAX IN USCITA per canale MAX OUTPUT POWER each channel INGRESSI DI CONTROLLO CONTROL INPUTS SCATOLA CASE DIM. DIM. 2AMDI584IPDBS 8-53V DC da 170mA a 1050mA From 170mA to 1050mA 2 54.6W a 52V DC Pulsante isolato x2, DALI x1 BLUETOOTH LE x1 Push insulated x2, DALI x1 BLUETOOTH LE x1 SI 40x80 mm h 24,45 mm Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 3

DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE POWER SUPPLY CONNECTION DIAGRAM AND LED 2AMDI584IPDBS - FIGURE N. 1 The 2AMDI584IPDBS dimmer has to be powered according to the polarity showed in FIG. 1 through the DC IN (+ and -) terminals. In case the power supply polarity is inverted no damage will be caused to the device. The LED (LED PWR) positioned on the circuit board indicates the presence of power supply. The LED (LED DIM) shows the dimming level of the output. The LED load connection has to be made by using the OUT (L+ CH1- e CH2- ) terminals. Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 4

OPERATION MODE PUSH MODE WHITE TUNABLE + BLUETOOTH (DEFAULT) PUSH WIRING DIAGRAM 2AMDI584IPDBS - FIGURE N. 2 In order to activate this mode of control/operation it is necessary connect between the DALI/PUSH1 terminals and between the PUSH2 terminals a signal in direct or alternating voltage (DC voltage range:10 265V, AC 12 265Vac 50 65Hz) interrupted by a normally open button (N.O.). No polarization is needed for the input signal The maximum current absorbed by the PUSH interface is about 2mA. PUSH1 input drive the colore temperature. PUSH2 input drive the intensity. The dimmer saves the output position in order to restore the set level in case of power failure (preset). PUSH 2 interface operation Single Click (rapid press (<1sec)) - Turns on or off the output (ON/OFF). Double Click (rapid press (<1sec)) - Sets maximum brightness (output= 100%) Long Press (long press (>1sec)) - If the dimmer is in OFF position, it sets the output to the minimum value (default= 1%) - If the dimmer is in ON position, the long press enables the output dimming (up/down). PUSH 1 interface operation Long Press (long press (>1sec)) - Change color temperature ( example Hot -> Cold e Cold -> Hot) Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 5

PUSH MODE 2 SEPARATED CHANNELS + BLUETOOTH PUSH WIRING DIAGRAM 2AMDI584IPDBS - FIGURE N. 3 In order to activate this mode of control/operation it is necessary connect between the DALI/PUSH1 terminals and between the PUSH2 terminals a signal in direct or alternating voltage (DC voltage range:10 265V, AC 12 265Vac 50 65Hz) interrupted by a normally open button (N.O.). No polarization is needed for the input signal. The maximum current absorbed by the PUSH interface is about 2mA. The dimmer saves the output position in order to restore the set level in case of power failure (preset). PUSH interface operation Single Click (rapid press (<1sec)) - Turns on or off the output (ON/OFF). Double Click (rapid press (<1sec)) - Sets maximum brightness (output= 100%) Long Press (long press (>1sec)) - If the dimmer is in OFF position, it sets the output to the minimum value (default= 1%) - If the dimmer is in ON position, the long press enables the output dimming (up/down). Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 6

DALI MODE 2 CHANNELS DALI WIRING DIAGRAM 2AMDI584IPDBS - FIGURE N. 4 In order to activate this mode of control/operation it is necessary connect the DALI bus between the DALI/PUSH1 inputs. On the first reception of a properly formatted DALI package the dimmer is configured in DALI mode. Once configured in DALI mode and disconnected from the DALI bus the dimmer switches to the POWER ON LEVEL mode set through DALI bus. The maximum current absorbed by the DALI bus is about 2mA. The device is seen by DALI bus like 2 indipendent devices. The DALI bus can control each channel dimming level separately. ATTENTION IN THIS MODE THE BLE (Bluetooth) CONTROL IS FORBIDDEN. Below you can find the implemented standard commands: DIRECT ARC POWER OFF UP DOWN STEP UP STEP DOWN RECALL MAX LEVEL RECALL MIN LEVEL STEP DOWN AND OFF ON AND STEP UP GO TO SCENE (0-15) RESET STORE ACTUAL LEVEL IN THE DTR STORE THE DTR AS MAX LEVEL STORE THE DTR AS MIN LEVEL STORE THE DTR AS SYSTEM FAILURE LEVEL STORE THE DTR AS POWER ON LEVEL STORE THE DTR AS FADE TIME STORE THE DTR AS FADE RATE STORE THE DTR AS SCENE (0-15) Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 7

REMOVE FROM SCENE (0-15) ADD TO GROUP (0-15) REMOVE FROM GROUP (0-15) STORE DTR AS SHORT ADDRESS QUERY STATUS QUERY BALLAST QUERY LAMP POWER ON QUERY LIMIT ERROR QUERY RESET STATE QUERY MISSING SHORT ADDRESS QUERY VERSION NUMBER QUERY DEVICE TYPE QUERY PHISICAL MINIMUM LEVEL QUERY POWER FAILURE QUERY CONTENT DTR1 QUERY CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL QUERY MIN LEVEL QUERY POWER ON LEVEL QUERY SYSTEM FAILURE LEVEL QUERY FADE TIME/FADE RATE QUERY SCENE LEVEL (0-15) QUERY GROUPS (0-7) QUERY GROUPS (8-15) QUERY RANDOM ADDRESS H QUERY RANDOM ADDRESS M QUERY RANDOM ADDRESS L Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 8

BLUETOOTH CONTROL In order to activate this mode of control/operation it is necessary to install the Necto Group app on the Android or ios device that you want to use for the 2AMDI584IPDBS dimmer control. The implemented features are: Switching on and off and the brightness level control of each individual light point. Ability to group together and control several light points with just a simple command. Creation and recall of your favourite lighting sceneries. The system management from a single simplified user interface. THE BLUETOOTH LE CONNECTION DOES NOT REQUIRE PAIRING PROCEDURE Necto Group App features (* depending on the device only some functions may be available) Dimmer management at 1 or 4 channels with different modes of operation: - Mono channel - 4 synchronized channels - RGB (3 channels or 3 zones) - RGB + White (4 channels or 4 zones) - Dynamic White Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 9

In order to install the app on your Apple or Android device you need to scan the desired QRCode to be automatically redirected to the product data sheet of the IoT Light application. As an alternative you can download the app by clicking on one of two links below: Apple: https://goo.gl/qezz5s Android: https://goo.gl/5rkymm Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 10

PARAMETERS CONFIGURATION CLICK ON THE WANTED CONFIGURATION TO VIEW 2AMIN4030000N PROGRAMMER IMAGE Reset Configuration A B C D 1 2 3 4 5 6 7 8 9 10 Reset ON ON ON ON ON ON ON ON ON ON ON ON ON ON Dimming Curve Configuration A B C D 1 2 3 4 5 6 7 8 9 10 Logarithmic OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Linear OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON PWM Configuration A B C D 1 2 3 4 5 6 7 8 9 10 PWM Standard OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF PWM Inverted OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON Fade Configuration A B C D 1 2 3 4 5 6 7 8 9 10 Fade Off OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Fade On OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON Change Mode Configuration A B C D 1 2 3 4 5 6 7 8 9 10 Input PUSH (NOT ISOLATED) OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF white tunable + Bluetooth Input PUSH (NOT ISOLATED) OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON 2 independent channels + Bluetooth Input DALI 2 channels OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF Current Configuration A B C D 1 2 3 4 5 6 7 8 9 10 170 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 182 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON 195 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF 210 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON 222 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF 235 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON 250 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF 260 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON 270 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF 290 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON 300 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF 315 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON 330 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF 345 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON 355 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF 370 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON 385 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF Necto Group S.r.l. 35127 395 Padova ma - Via Canada, 8 - ITALY OFF - T +39 ON049 OFF 8791001 OFF F OFF +39 049 OFF8791002 OFF Email OFFinfo@nectogroup.com ON OFF ON pag. 11

355 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF 370 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON 385 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF 395 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON 410 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF 425 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON 438 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF 450 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON 465 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF 480 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON ON 490 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF 500 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON 515 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF 530 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON ON 545 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF 560 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF ON 575 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON ON OFF 585 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON 600 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF 615 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON 626 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON OFF 640 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON ON 653 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF OFF 667 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF ON 680 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON OFF 694 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON 707 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF 721 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF ON 734 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF 748 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON ON 761 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF OFF 775 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF ON 788 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON ON OFF 802 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON ON ON 815 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF 829 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF ON 840 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON OFF 855 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON ON 870 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF OFF 880 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF ON 895 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON ON OFF 910 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON ON ON 920 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF OFF 935 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF ON 950 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF ON OFF 965 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF ON ON 975 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON OFF OFF 990 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON OFF ON 1020 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON ON OFF 1050 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002 Email info@nectogroup.com pag. 12