Ampgard The name motor applications rely on

Similar documents
Ampgard medium voltage motor control renewal parts

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Industry s most comprehensive medium voltage circuit protection

This small footprint makes a BIG impact

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Medium Voltage Metal-Enclosed Switches

Tradition. Technology. Innovation.

Medium Voltage Metal-Enclosed Switches

Medium Voltage Fuses. Industry s most comprehensive medium voltage circuit protection

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Instructions for AMPGARD 400A medium voltage starter

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Metal-enclosed medium-voltage power factor correction system

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Specification made simple for selective coordination in a compact size

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

MEDIUM VOLTAGE PRODUCTS

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

Powering business worldwide

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Eaton Corporation An Overview Eaton Corporation. All rights reserved.

Submersible Vacuum Fault Interrupters

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

POWERCON CORPORATION

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

ABB. Replacement Components

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Eaton s enclosed meter family. Single- and multi-unit. enclosed meters

Bolted contact switches. Pringle switches

The easiest and fastest way to select and specify the right fuse

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

Medium Voltage Adjustable Frequency Drive

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

The easiest and fastest way to select and specify the right control circuit fuse

Quick selector reference guide. Motor Control Center Aftermarket Buckets

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Metal-enclosed medium voltage power factor correction system

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Substation Committee K2 TF1 of the GIS Subcommittee GIS/GIL/SF 6 -Tutorials

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

SECTION 16349X MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

Integrated Power Solutions

Effective December 2015 Supersedes September 2013

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

MESG 12 / 17.5 / 24 / 36 KV

Zone Selective Interlocking

NXPLUS C Single busbar. Maintenance-free for lifetime

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

the safe, reliable, and efficient choice for MV switchgear

Chapter 6 Generator-Voltage System

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

C1000 Series Automatic Cap Bank

XIRIA Green, Smart, Compact solution

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Pow-R-Flex low ampere busway

Medium Voltage Products Table Of Contents

Design Standard. Purpose: Design Standard:

Eaton vacuum interruption (EVI) technology. Proven vacuum interruption technology Environmentally focused circuit protection for global innovation

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Why arc-resistant drives need to be considered

Medium & Low Voltage Switchgear. Project Highlights

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Metal Clad Air Insulated Switchgear

Gas Insulated Metal-clad Switchgear, HMGS!

Capabilities Brochure

Low & Medium Voltage Vacuum Contactors

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

ABB Power Products Medium Voltage MV SERVICE. Florence, SC Napa, CA Coral Springs, FL. ABB Inc. -1- March, 2007

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

PowerCube type PB series A complete solution for OEMs

Unitole UP kv Primary substations Motor control centres

Powered by Safety. Powell Service Division Services Overview

GE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Installation Guide

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

Transcription:

Medium-voltage motor control Ampgard The name motor applications rely on Oil and gas Mining Water/wastewater Pulp and paper Utility

Ampgard medium-voltage control solutions Eaton has been an industry leader for more than 40 years, providing ULT 347 certified medium-voltage control. When it comes to controlling and protecting medium-voltage motors, the AmpgardE family is the premier high-performance choice. 15 kv standard MVC 7.2 kv standard MVC 2 EATON Medium-voltage motor control

A legacy of reliability for more than 4 decades 1950 1960 1970 1980* 1990 2000 2010 Present Actual years AMI Ampgard 1955 1962 Classic Ampgard LF airbreak 25L2 200 A 1962 1985 LF airbreak 50L2 200 A 1963 1981 LF airbreak 50L4 400 A 1965 1985 LF airbreak 50L7 700 A 1968 1988 SJ vacuum SJ72V4 1982 2000 SJ vacuum SJ72V8 1988 2010 SL vacuum SL72V4 2000 2010 Ampgard 7.2 kv/sl400 2005 present 7.2 kv/sj800 2005 2014 15 kv/sl300 2010 present 7.2 kv/sl800 2014 present SC9000 MV drive 2008 present *Manufacture point moved from Buffalo, NY to Asheville, NC in 1978 Classic Ampgard Air to vacuum retrofit Ampgard Ampgard has a dedicated aftermarket sales team that has access to your original order information. Using this information, the sales team can identify the exact parts required to maintain or upgrade your existing starters. Replacement parts are available for three generations of Ampgard starters. The original Ampgard design was built from the 1950s to the 1960s. The second generation design (now known as Classic Ampgard) was introduced in the 1960s and remained in production through the early 2000s. The current generation of Ampgard was introduced in 2005. The aftermarket team can also quote parts for SC9000 medium-voltage drives. EATON Medium-voltage motor control 3

Starters All major starter components are manufactured by Eaton, providing increased reliability and equipment support. Vacuum contactors Isolation switches Power fuses Control power transformers Potential transformers With a wide selection of starter types at voltages from 2.3 kv to 13.8 kv and ratings up to 8000 hp, Eaton is equipped to provide an Ampgard starter specifically designed for your critical application including: Full voltage Reduced voltage reactor Reduced voltage autotransformer Reduced voltage solid-state Two-speed, two-winding Two-speed, one-winding Synchronous Reversing Full-voltage starter Contactors Isolation switches Fuses 400 A vacuum contactor Isolation switch Bolted and clip-in main fuse Ampgard vacuum contactors provide the highest interrupting ratings in the industry, with field-selectable control voltage and dropout time Long life 300,000 electrical operations Available with bolted or fingerand-stab connection to 400 A, finger-and-stab only at 800 A Long life isolation switch rated for 10,000 operations, simplifies lock-out/tag-out while minimizing maintenance Mechanical interlocks to prevent operation of isolation switch with main contactor closed Mechanical interlocks to prevent access to mediumvoltage compartment until isolation switch is open Current limiting to minimize the effects of high fault currents Sized to ensure repeated motor starts without fatigue Available as bolted or clip-in up to 400 A, bolted only at 800 A Blown fuse indicator standard Reduced-voltage solid-state starter Visible verification of isolation switch operation through viewing window Optional remote operator for connection/disconnection from power bus while personnel is outside the arc flash zone Increased reliability and equipment support 4 EATON Medium-voltage motor control

Protective relays E-series relays for traditional applications Starter with EMR relay EMR-3000 for current protection EMR-4000 for current and voltage protection URTD for temperature protection Eaton.com/relays Enclosures Ampgard motor control solutions are all seismic certified and available in an enclosure type for nearly every operating environment: NEMAT 1 general purpose NEMA 1G general purpose with gasketed doors NEMA 12 dust-tight NEMA 3R outdoor (non-walk-in) Providing superior motor protection EATON Medium-voltage motor control 5

Arc flash solutions Arc-resistant Ampgard AR Arc-resistant Ampgard ARE is available for applications requiring increased operator protection. Extensively tested to IEEET C37.20.7-2007 requirements for Type 2B accessibility, Ampgard AR incorporates the key features of traditional models, plus: Rear arc chamber, roof flaps and plenum to allow arc gasses to flow away from the operator Strengthened front doors and latches to ensure doors remain closed Insulated main bus minimizes risk of bus fault Low-voltage control compartment verified to meet arc-resistant requirements (Type 2B) Ampgard AR arc-resistant can be close-coupled with the following, for a coordinated, tested, arc-resistant customer solution: ArcGardE arc-resistant metal-clad switchgear Arc-resistant metal-enclosed medium-voltage switches SC9000E EP arc-resistant medium-voltage drive Ampgard remote operator The Ampgard remote operator enables users to open or close the starter s isolation switch through the use of a pushbutton station operated up to 30 feet from the starter, allowing the user to remain out of the starter arc flash zone. The remote operator is easily attached to the front of an Ampgard starter when the isolation switch needs to be opened or closed 120 Vac is required for operation All starter mechanical interlocks remain operational during use Ampgard remote operator Ampgard AR arc-resistant close-coupled with SC9000 EP arc-resistant drive 6 EATON Medium-voltage motor control

Enhancements Manufacturing flexibility Multiple manufacturing sites develop and manufacture customized products and solutions locally and provide you with local access to witness tests and inspections, in-depth technical skills and market knowledge. Main breaker LBS Synchronous transfer with medium-voltage drive Integrated disconnect Eaton VCP-W main breaker 1200 A, 2000 A, 3000 A, 50 ka Metal-enclosed, totally front accessible Optional remote racking LBS switch for main, tie or feeder disconnect applications 600 A, 1200 A, fusible and non-fusible Double-bus design Double-bus design for close-coupling with mediumvoltage drives for synchronous transfer applications Asheville, NC Edmonton, Canada Portland, OR EATON Medium-voltage motor control 7

Engineering services Eaton s Electrical Engineering Services & Systems coverage map District Operations Center Power Breaker Reconditioning Centers Satellites Power Breaker Center District Operations Center Satellite Field Resources 1 1 Locations subject to change. About Eaton s Electrical Engineering Services & Systems Eaton s Electrical Engineering Services & Systems is one of the largest and most experienced industrial service organizations in North America. With more than 1500 highly trained professionals in 60 engineering service locations throughout the U.S. and Canada, Eaton s Electrical Engineering Services & Systems has complete local, national and international capabilities to provide a full range of electrical, civil and mechanical equipment services. In addition, Eaton provides an additional year of warranty, beyond our standard warranty, when site acceptance testing and power system studies are performed by Eaton s Electrical Engineering Services & Systems field service organization. This broad range of service capabilities has established us as a leader in the engineering service industry. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2018 Eaton All Rights Reserved Printed in USA Publication No. BR02003002E / Z21147 July 2018 Eaton is a registered trademark. All other trademarks are property of their respective owners. Follow us on social media to get the latest product and support information.