SafeStart hand held SafeStart Initiators (SI-1)

Similar documents
PRIMADET non-electric delay detonators MS Primadet - millisecond series

PRIMADET non-electric delay detonators Dual StoperTM

NONEL EZ DET. Properties. Technical Information. Nonelectric Blast Initiation System. Your Partner with TOTAL BLASTING SOLUTION

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

INITIATING SYSTEMS ACCESSORIES RANGE

650mA Phase Dimmable LED Driver

1000mA - 650mA Phase Dimmable LED Driver

Shock Tube Saver System Installation and Operation Manual Duke Part No Rev. B

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Kompensator External Low Voltage Heating Cable System

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

OPERATING INSTRUCTIONS

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

PVI 60KW, PVI 82KW, PVI 95KW

Sinewave Inverters. SWING 150VA and 300VA. User s manual

EX Series User Manual

VP Remote User s Manual (nvp)

DALI 650mA LED Driver

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Toll Free DX100. Owner's Guide. Printed in China

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Manual Installation & Operation

IN120L / IN120LB / TM120L/TM120LB IN2400L

INSTALLATION/OWNERS MANUAL

IN & TM Series User Manual

MOD.15 MAE Flameproof Alternator 500W

BroadBand PowerShield. 20 AHr Battery. User Manual

User s Manual. Automatic Switch-Mode Battery Charger

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

DALI Emergency LED Driver - 350/700/1000mA Constant Current

Operator Instructions for Tension Links

CBA Charge Controller

IMPORTANT SAFETY NOTICE

English. Instruction and operation manual S 212. Dew point sensor

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

Smile 11 RA/-B Smile 12 RF/-G Reset button

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

Unified requirements for systems with voltages above 1 kv up to 15 kv

Twelve Unit Rapid Charger

CTFRP Series Power Supplies

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

ORICA NEW ZEALAND WESTPORT - PRICE LIST

Table of Contents. Page 2. midlandusa.com. Model PPG100

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

BP1204 INSTALLATION/OWNER'S MANUAL

Go Power! Manual. GP-Smart Charger

PY-11 Voltage & Continuity Tester

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

Tina 10A/B/C Adaptor unit

Sense7-series Non-contact coded safety switch

Product Data Sheet : LIGHTHAWK 6 CELL

Battery Charger. Series EASY Charger. User s manual

3-Year Limited Warranty. See the Users Manual for the full warranty.

Notice of Copyright XPower Pocket Inverter 100 Owner s Guide September 2006 Xantrex International. All rights reserved.

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

Operating Instructions

Product Information Responsibilities of Owners Safety Instructions Warning Labels Installation Instructions...

ANTI-SYPHON VALVE INSTALLATION GUIDE

Information Bulletin. Fire Pump Battery Failures. Version 1.1 Approved for release August 2011

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

TABLE OF CONTENTS 11.0 WARRANTY

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

(KERNEL) SAND BLAST CABINET ( 220L ) ASSEMBLY & OPERATION INSTRUCTION

Coating Thickness Gauges

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

Users Manual. Phase Rotation Indicator

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

IMPORTANT SAFETY INSTRUCTIONS

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

ABRASIVE BLAST CABINET

Owner s Manual & Safety Instructions

Operating Instructions

EStrong-series Emergency Stop

WEB CONTROL PRODUCTS

M Series External Battery Frame. User Guide

Easy-On Wireless Tail Lights User s Guide

Product Information Responsibilities of Owners Safety Instructions Warning Labels Installation Instructions...

User Guide. Model No.: GDI-GFD7200

Battery Charger Series EASY Charger

MKey9-series Safety Interlock Switch with Guard Locking

600 Amp Battery Jumper with Air Compressor

HOVERTRAX 2.0 HOVERTRAX DLX 2.0 REPLACEMENT BATTERY PACK KIT

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

Go to to register your product and find more information.

OROAD-400 Traction Drive Electric Cart Use & Maintenance Manual

PowerFLEX Module Limited Warranty Program

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

RIGID ENTRY BOOT INSTALLATION GUIDE

MaxLite StaxMax LED Flood Lights

Operating Instructions for PAC800 Battery Charger

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

i3000s/i2000 Flex AC Current Probe

EnergyCell FLA Series. Owner s Manual

Single Unit Rapid Charger FOR RECHARGEABLE TWO-WAY RADIO BATTERIES

EC DECLARATION OF CONFORMITY

Transcription:

SafeStart hand held SafeStart Initiators (SI-1) function The hand held SafeStart Initiators (SI-1) is designed to fire a SafeStart instantaneous detonator from a distance of up to 1km away using standard blasting wire or cable. It is primarily used for secondary blasting. description The unit is a functional replacement for conventional shot exploders and is fully approved by the SABS in accordance with SANS 1717-2, Inspection Authority (IA) certificate number SABS M 109-287X. The hand held SafeStart Initiators (SI-1) consists of five main components: 1. A toughened plastic enclosure /casing that is fully water resistant. 2. Key and key switch. 3. An indicator LED, which glows to show correct operation. 4. A replaceable PP3-9V alkaline battery, capable of at least 1500 firing cycles. 5. Red lead attachments. 6. Carry strap and pouch.

advantages safety SafeStart Instantaneous Electronic Detonators are free from electrical and environmental hazards commonly found in mining applications. Furthermore the SafeStart Instantaneous Electronic Detonator is safe against unauthorized use connecting the detonator to miner cap lamps or external voltage sources does not result in firing. Warning: Although certified to be safe, NEVER connect the SafeStart Instantaneous Electronic Detonators to any energy source other than the SafeBlast Centralised Blasting System (CBS) or the hand held SafeStart Initiators (SI-1). Failure to do so may result in injury, death or prosecution. External SafeStart 110 V ac 220 V ac 250 V ac Penlight battery Vehicle battery (12Vdc; 24Vdc) Lightning Radiated lightning currents Static discharge of electricity EMI / EMC (cell phones, two way radios) Electro-magnetic interference Switching devices Insulation testers (1KV) Telephone loop (50V dc) - will not initiate reliability Hand held SafeStart Initiators (SI-1) are assembled to stringent quality standards improving reliability and robustness. A replaceable PP3-9V alkaline battery, capable of at least 1500 firing cycles, is used to provide power to the unit. accuracy Hand held SafeStart Initiators (SI-1) are designed for millisecond response times allowing for improved accuracy and precision. cost effective The hand held SafeStart Initiators (SI-1) should be returned for servicing as per SANS 01325-2:2001 resulting in extended use and an extended life span. simplicity/flexibility Operated by key switch, an indicator light glows to show correct operation. 2

product information Nominal Firing Voltage 160-300 VDC. Short Circuit Current Limit 40mA maximum (measured). Firing Mechanism Spring Loaded Key Switch. Operating Time 1.9-2.5 seconds. Firing Indicator LED indicator glows during operation. Firing Capacity Fires one SafeStart detonator from a distance of up to1km away. Battery Type Replaceable PP3-9V Alkaline Battery. Life More than 1500 cycles. Unit Dimensions 120mm x 82mm x 40mm Unit Mass 0.55kg Temperature Range -5 C to 45 C applications The hand held SafeStart Initiators (SI-1) has the following use: Secondary blasting. Note: Not approved for use in fiery mines. primer assemblies Figure One The placement of guards and barricades must be done in accordance with mine rules and standards. Permissions and warnings for an impending blast must be done in accordance with mine rules and standards. Once all the safety considerations have been taken into account, the face is charged up and connected. Connect the SafeStart Instantaneous Electronic Detonator unit to the blasting wires and ensure that no shorting or shunting of wires occurs. If an EZ Platinum Trunkline / EZ Trunkline is being used as a starter unit for the blast, clip the SafeStart Instantaneous Electronic Detonator unit onto the EZ Platinum Trunkline / EZ Trunkline (Figure One). If the face is to be initiated directly by the SafeStart Instantaneous Electronic Detonator, clip the SafeStart electronic starter detonator onto the shocktube of the first hole. 3

important instructions Please note the following: Only authorized personnel may operate a SafeStart Initiators (SI-1) i.e. personnel in possession of a valid blasting certificate. Follow the brief operating instructions, stated on the front panel of the SafeStart Initiators (SI-1). Equipment may not be used if it appears to be faulty, tampered with or otherwise physically damaged. The mine must adhere to SANS 01325-2:2001 and IA certificate SABS M/09-287X regarding maintenance of the SafeStart Initiators (SI-1). The SafeStart Initiators (SI - 1) key should be separated from the unit at all times, unless intending to fire. Excessive vibration and shock should be avoided during transport and storage. All blasting circuits should be checked. Use of an ohmmeter and earth leakage tester is strongly recommended. The SafeStart Instantaneous Electronic Detonator should be stored securely, preferably locked away with only authorized access. To ensure maximum life capacity, a storage temperature range of 10 C to 50 C is recommended. Short duration temperature excursions of up to 85 C are however permitted. Ensure that all downlines and outgoing trunkline leads are securely clipped. SafeStart Instantaneous Electronic Detonator is designed to initiate shock tube only and should not be used to initiate detonating cord as this may result in a misfire. Never trim, tamper with or disassemble the SafeStart Instantaneous Electronic Detonator since the entrance of moisture and/or dirt may cause misfires. Never attempt to disassemble the delay cap or use the cap without the block. The surface connectors contain blasting caps and are subject to detonation caused by abuse such as impact, as with all detonators. The connector block accommodates ONE shocktube. Never attach the primary Initiators (SafeStart Instantaneous Electronic Detonator) to the blast until the blast is completely hooked up and the blasting area cleared. Always store detonators and explosives separately. Keep explosives and accessories away from sparks, flames or any other sources of ignition. Excessive temperatures may result in spontaneous ignition of explosives and accessories. Store explosives accessories according to the country rules & regulations. For best results, refer to the manufacturer s operating instructions for hook up (Module 3 Operating the NSS and connecting SafeStart Instantaneous Electronic Detonator). Do not remove the leg wires from the block simply clip the shock tube into the cavity with the wire. 4

packaging information Only one specific model (a SafeStart Initiators (SI-1)) is available. Only standard product lengths and packaging is available. Please contact your representative. standard packaging Box Dimensions Units per case 120mm x 82mm x 40mm 1 colour codes, labelling & delay The SafeStart Initiators (SI-1) has a yellow casing. It is clearly labelled in accordance with the regulations. recommended storage, shelf life & transport Hand held SafeStart Initiators Recommended storage Indefinitely Shelf life (batteries) 3 months Shelf life (SafeStart Initiators (SI-1) Indefinitely Transport: UN classification N/A (as per standard electric / electronic devices) UN number N/A Zax number N/A warning and disclaimer All products and equipment manufactured and supplied by Sasol Nitro s Explosives Business shall be used, handled, stored or transported according to the guidelines laid down by the relevant applicable legislation in that country. Explosives should be secured in an explosive magazine. All or any part of the explosives is dangerous and can cause injury or death. If you find any of these items, do not touch them. Instead, immediately report their location and description to the police. To the extent provided for in terms of section 61 of the Consumer Protection Act, 2008, Sasol Nitro Explosives Business shall not be liable for ny damage, whatever its nature, including incidental, consequential and indirect damage caused to buyers or third parties, directly or indirectly arising from or relating to the supply, use or storage of the products and equipment arising after delivery unless caused by Sasol Nitro s Explosives Business wilful misconduct or gross negligence. *Trademarks are registered or applied marks are licensed to Sasol. 5 Sasol Nitro 15 Baker street Rosebank 2196 PO Box 5486 Johannesburg 2000 South Africa +27 (0) 11 441 3111 www.sasol.com Rev 2 September 2013