NTD. Volumetric flow meters with IP-55 or EExd protection. Nuevas Técnicas de Dispersión, S.L.

Similar documents
Turbine flowmeters Series TM

Positive displacement flowmeter for continuous flow measurement

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

ISTEC MAGNETIC METERS

Paddle-wheel flow controller with optical principle for On/Off control

Magnetic Inductive Flowmeter EP / UMF2 (B)

Electromagnetic Flowmeters. Product Overview.

Industrial OG meter series IOG Inline and flanged oval gear meter

INSERTION flow sensor for continuous flow measurement

2100 Turbine Flow Sensor

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

Paddle-wheel flow controller for On/Off control

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Paddle-wheel flow controller for On/Off control

QUALITY INDUSTRIAL FLOWMETERS

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Flow Transmitter / Switch OMNI-RR..32

Level switches Series LC40 Float level switch for liquids

Flow meter Type Recordall (RCDL)

Flow Transmitter / Switch OMNI-RR..32

Positive displacement batch controller

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

G2 Industrial Grade Meters

SHENITECH, LLC

Metal tube variable area flowmeter for gases, liquids and steam

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Flow switches Series AD/VH

Instructions EM 101 Low Flow Electromagnetic Flow Meters

OMP Positive Displacement Flowmeters

ProcessAutomatic EZ-Mag

MX-SERIES OVAL GEAR FLOW METERS

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

OMP POSITIVE DISPLACEMENT FLOWMETERS

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Insertion magnetic inductive flowmeter

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

digital flow meters BW Digi-Meter F-1000

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

OPTIFLUX 6000 Technical Datasheet

유량계전문제조업체. Electro Magnetic FLOWMETER

PMG MAGNETIC FLOWMETER

BATCHFLUX 5500 C Technical Datasheet

Flow Transmitter / Switch OMNI-RR..32

Design and application

Plastic tube variable area flowmeter for liquids and gases

POSITIVE DISPLACEMENT FLOW METERS

Digital ph transmitter

Level Limit Switch liquiphant FTL 360 / FTL 361

MAIN FUNCTION FEATURES. . D = v t /2

OM004, OM006 & OM008 Oval Gear Meter

QUALITY INDUSTRIAL FLOWMETERS

Electromagnetic flowmeter EMKO E

PROCESSAUTOMATIC MAGNETIC FLOWMETER

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

POSITIVE DISPLACEMENT FLOW METERS

PSF50 Paddle flow switch

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Magnetic Inductive Flow

GA 24 Heavy-duty variable area flowmeter

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Flow - rotor, inline model

flow x3 flow monitoring

magnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Flap-Type Flow Meter Prall

Liquid Turbine Flow Meter OwnerÊs Manual

Digital ph transmitter

F-2600 SERIES INLINE VORTEX FLOW METER

VHS... Screw Flow Meter

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

F-1500 SERIES INSERTION TURBINE FLOW METER

Level Limit Switch liquiphant FTL 365 / FTL 366

PA - Turbine Flowmeter Range

macnaught flow measurement

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

High Performance Turbine Technology

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Electromagnetic Flow Monitor magphant

CONTOIL VZFA/VZOA , versions for higher requirements / applications

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

RIM20 Rotor Insertion Flowmeter

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

Transcription:

Nuevas Técnicas de Dispersión, S.L. Pol. Ind. La Esperanza, C/Comunidad de Murcia, 152 12400 Segorbe (Castellón) España Tel. +34 964714032 - info@ntdmaquinaria.com www.ntdmaquinaria.com NTD Volumetric flow meters with IP-55 or EExd protection NTD has included in its production line a new wide range of volumetric flow meters. AFE Flange Series Agressive Liquid Series CEB/09 CEB/09 CE CE O-P 0 PROGRAMMER P Programmer M-A-I-C Converter Converter M-A-I-C

2 Flow meters TURBINE Materials: Stainless steel (PVC, PVCF TX range) Accuracy: ±1% Pipe connection: Thread / flange MODELS Flow Range ELECTROMAGNETICS Materials: Stainless steel, teflon Accuracy: ± 0'5% Pipe connection: Different options MODELS Flow Range Additional Fittings READING HEAD CEB/09 Functions: (depending on model) Pulse output 4 20 ma Output Flow indication Totalization Partial with reset to zero PROGRAMMER-METER CE 0-P Functions: Pre-selection and dosage Volume totalizing counter Partial volume counter and reset to zero Constant value setting on counter Two-stage batching M-A-I-C Functions: Frequency / current converter Flow / totalizer indication 4 20 ma, 0 10 V, 0 20 ma outputs Completely configurable

9 Meters and Turbine Flow MeterS Stainless Steel series FEATURES STRONG AND RELIABLE UNIT MADE OF STAINLESS STEEL LOW COST OF PURCHASING AND MAINTENANCE SPECIALLY SUITABLE FOR LOW VISCOSITY LIQUIDS (up to 30 cp) HIGH TEMPERATURE RESISTANT (Up to ºC) and PRESSURES (Up to 300 bar) AVAILABLE HIGH ACCURACY (error lesser than 1%) HIGHER ACCURACY AT SPECIFIC FLOWS (CC4 Certificate) MAIN APPLICATIONS FOOD LIQUIDS WINE, VINEGAR and ALCOHOL RON, WHISKY, GIN, etc HORCHATA (tigernut drink) MILK AND WHEY BEER SOME JUICES WATER AND MINERAL WATER NON-FOOD LIQUIDS LIQUID FERTILISERS DE-MINERALISED WATER PEROXIDE STEAM CONDENSATE SOLVENTS ISOCYANATE, FORMOL DIESEL OIL, GASOLINE and QUEROSENE CUTTING OIL WEAK ACIDS

10 OPERATING PRINCIPLE Turbine flow meters are provided with a rotor which rotates when the fluid applies a force to the rotor's blade. Rotational speed is proportional to the flow, so volume of fluid will de determined by rotor's speed. In order to know speed of rotor, a sensor detects each pass of the blade. The frequency of pulses of the sensor determines the flow passing through. METER ASSEMBLY Better use a straight pipe for meter assembly with the same internal diameter than the meter and no less than 5 times the diameter at outlet point, and 10 times at inlet. The placement of the meter in the pipe is indicated by means of an arrow printed on meter's body. The arrow also indicates the direction of the fluid. OPTIONS Liquid temperature up to 90ºC, 120ºC, 150ºC and ºC. Liquid pressure up to 300 Bar AISI 3 material and turbine casing by HALAR Reading head: CEB09 self-powered CEB09/SI with pulse output selfpowered CEB09/SIA with pulse output and analogic. Power supply 24v (ac-dc). CEB09 Eexd flame proof. CEB09/SIA Eexd with pulse outlet and analogical, flame proof. CEB07 flame proof Pipe connection: flange DIN and ANSI The meter can be assemble horizontal or vertically. However, it is recommended a vertical position as shown in figure below. RIGHT ASSEMBLIES RIGHT ASSEMBLY MODEL TC-15 TEMPERATURE (ºC) Standard 55 Maximum (optional) up to PRESSURE (Bar) Standard Maximum (optional) up to 300 TECHNICAL SPECIFICATIONS FLOW (l/h) (1) MATERIALS Body Minimum Maximum Turbines Standard Option 300 5.000 AISI 420 AISI 304 AISI 3 Thread Standard CONNECTIONS Clamp Connection DN 15 Flanges DIN DN 15 PN 40 Options Flanges ANSI 1/2" DIMENSIONS A B C D 144 110 DN 15 140 TC-32 55 300 1.000 10.000 AISI 420 AISI 304 AISI 3 1 1/4" DN 15 PN 40 1 1/4" 110,5 DN 32 142 TC-50 55 300 3.000 30.000 AISI 420 AISI 304 AISI 3 2" DN 15 PN 40 2" 119 DN 50 150,5 TC-80 55 300 5.000 100.000 AISI 420 AISI 304 AISI 3 3" DN 15 PN 40 3" 135 DN 80 5,5 (1) Suitable for water. For liquids with other viscosity, please consult G-Flow

11 Electromagnetic Meters and Flow Meters AFE series FEATURES SPECIALLY INDICATED FOR CLEAN CONDUCTIVE LIQUIDS OR WITH SUSPENDED SOLIDS. STRONG AND SIMPLE UNIT WITHOUT INTERNAL MOBILE COMPONENTS INTERNAL TUBE MADE OF TEFLON PFA: FOOD PROCESSING industry (specific connection optional) High resistance against CHEMICAL AND ABRASIVE PRODUCTS MAIN APPLICATIONS FOOD-PROCESSING INDUSTRY MILK and MILK PRODUCTS BEER WINE, VINASSE and non-filtered MUST. FRUIT JUICE CHOPPED OR FRIED TOMATO SAUCE AND JELLY DRINKABLE WATER LIQUIDS containing WATER OTHER APPLICATIONS SULPHURIC ACID SODA and CITRIC ACID SYNTHETIC RESINS CALCIUM CARBONATE DETERGENTS AND SURFACTANTS SEWAGE etc.

12 MAIN FEATURES No mobile components which means low pressure drop Internal tube TEFLON PFA and electrodes by Hastelloy C4 Suitable for food-processing industry with optional specified connections Chemical products resistant High resistant against abrasion OPERATING PRINCIPLE The conductive liquid passes through the metering tube applying electric voltage between two electrodes ( sandwich connection ) as an electromagnetic field has been created across the tube. This voltage is proportional to speed and therefore, proportional to the flow. Easy installation Power supply: 220Vca Pulse outlet and 4-20 ma IP67 protection Current and total flow indication Waffer connection (between flanges) TECHNICAL SPECIFICATIONS MODEL PRESSURE MAX (Bar) AFE-10 AFE-25 AFE-50 AFE-80 AFE-100 TEMPERATURE (ºC) Min -25-25 -25-25 -25 Max 120 120 120 120 120 FLOW (l/h) (1) Min 35 600 2. 5.500 8.500 Max 3.350 31.000 84.000 217.000 339.000 MATERIALS Standard CONNECTION Option Internal Tube Electrodes External Tube Sandwich Flange Clamp Teflon reinforces with stainless steel mesh Teflon reinforces with stainless steel mesh Teflon reinforces with stainless steel mesh Teflon reinforces with stainless steel mesh Teflon reinforces with stainless steel mesh Hastelloy Hastelloy Hastelloy Hastelloy Hastelloy Steel with epoxi Steel with epoxi Steel with epoxi Steel with epoxi Steel with epoxi DN-10 DN-25 DN-50 DN-80 DN-100 DN-10 DN-25 DN-50 DN-80 DN-100 DN-10 DN-25 DN-50 DN-80 DN-100 DIMENSIONS (mm) A B C 68 54 100 150 242 252 256 285 312 140 140 140 140 140

13 Turbine-TX Flow Meter Corrosive Liquids series

14 Turbine meters MAIN ADVANTAGES MODEL TX FEATURES The TX flow meter is G-FLOW s answer to the market demands, asking for a reliable, accurate and inexpensive flow meter for the measuring of corrosive liquids. It s a paddle turbine flow meter. The flow sensor consists of a transducer and an open-cell paddle wheel. When immersed in the flow, the rotating paddle-wheel produces a frequency modulated measuring signal proportional to the flow. The TX model offers an effect Hall pulse output. Optionally it can provide a display and a 4-20 maoutput. Flow range varies from 500 L/h in the smallest sized models up to more than 3000 m3/h in the largest. Materials have been carefully chosen in order to provide an appropriate solution for corrosive liquid measuring (HCl, i.e.) Max. working pressure: 6 bar Max. working temperature: Three-wire sensor: 80ºC Accuracy: Output: ± 1% of measured value Three wire sensor : rectangular 0.. Hz pulse output Voltage supply: Three wire sensor: 12...30 VDC Protection Index: IP 65 Materials Rotor: PVDF Sensor housing: PVDF Axis and bearings: ceramic Fittings: PVC standard PVDF on request DIMENSIONS Fittings: Socket union (up to DN 50) Collar (diameters DN 65... DN ) DN External Diameter PVC (SOCKET UNION) mm in d (mm) A B 15 20 25 32 40 50 1/2 3/4 1 1 1/4 1 1/2 2 20 25 32 40 50 63 128 144 0 8 188 212 96 106 1 1 126 136 DN PVC WITH COLLAR mm in d A (mm) C D 65 80 100 150 2 1/2 3 4 6 8 75 90 110 0 225 124 138 2 210 278 105 105 105 102 102

15 FLOW RATE INDICATOR - CEBO9 Total, partial and flow Pulse input: NAMUR, reed, PNP, NPN, ENCODER Total, partial, flow Pulse input: NAMUR, reed, PNP, NPN, ENCODER Protection against hits Flame-proof (optional) Total, partial, flow Pulse input: NAMUR, reed, PNP, NPN, ENCODER Pulse output Total, partial, flow Pulse input: NAMUR, HALL, reed, PNP, NPN, ENCODER Pulse output 4-20 ma output

CEB09 indicates in the display volume and flow rates. It is compatible with the following pulse emitters: CEB09, CEB09/SI, SCEB9 and SCEB09/SI: NAMUR, REED, PNP, NPN, ENCODER CEB09/SIA and SCEB09/SIA: NAMUR, HALL, REED, PNP, NPN, ENCODER Sensor sends pulses out to the flow rate indicator. By means of the constant pulses/liter (number of pulses per liter), the reading device indicates: TOTAL VOLUME of liters measured from the beginning of the operation. LCD and 8 digits display show the measurements. PARTIAL VOLUME of liters and reset to zero (partial meter). LCD display for 5 10mm digits. INSTANTANEOUS FLOW RATE (liters per unit of time). LCD display for 5 10mm digits. PLC available for a remote control of meter. Models CEB09/SIA and SCEB09/SI (optional). 4-20 ma OUTPUT proportional to flow rate (optional). Models CEB09/SIA and SCEB09/SIA available. One of the main features of CEB09, SCEB09, CEB09/SI and SCEB09/SI models is the 5-7 years autonomous battery. This features easies the installation and makes possible the use of this readings units in places where is difficult to find power supply. 1 - PARTIAL METER 2 - FLOW FLOW INDICATION RATE OR PARTIAL MEASUREMENT UNITS INDICATION FLOW LITERS LITER INDICATOR or m3 TOTAL MULTIPLIER TOTAL VOLUME RATE LOW BATTERY CHARGE INDICATOR CONTACESA LOGO

17 Frequency 4/20mA Converter MAIC PULSE GENERATOR FLOWMETERS PULSES pulses with opto-isolator

18 Multifunction Frequency Converter The new M.A.I.C lets turn any pulse input generated by flowmeters, encoders, etc- into a current or voltage output which is proportional to the input pulses. It also divides the input pulses by a factor K. TECHNICAL SPECIFICATIONS Voltage: 220 Vac, 50/60 Hz Power: 3,2 VA Pulse input: Namur, NPN Maximum pulse input frequency: 1000 Hz Minimum pulse input frequency: 0.09 Hz Analogic output: 4 20 ma / 0 10 V Pulse divider: litres per 0.01, 0.1, 1, 10, 100 y 1000. Pulse output: Relay and open collector. Alphanumeric display. 2 lines and characters Working temperature range: 0 40 º C Mounting: DIN rail. Protection : IP 20 Dimensions: 125 x 75 x 55 mm FUNCTIONS Pulse divider Frequency / current converter Pulse indicator Frequency meter (pusle/s) Totalizer (total liters) Flow-rate indication (L/hr) Batch controller CONFIGURABLE PARAMETERS Password Function Type (flowrate/volume; frequency/pulses;batch) Output Type (4-20 ma, 0-10 V, 0-20 ma) Flowrate units (L/min., L/h, m3/h) Display data refreshment time Reading stability (manual or automatic) Pulse waiting limit time Reading decimal digits Gain of temperature sensor amplifier Pulse/litre rate at pulse output Output pulse width Batched volume Analogic output offset Analogic output scan ELECTRICAL CONNECTIONS POWER SUPPLY PULSE INPUT PULSE OUTLET (COLLECTOR) PULSE OUTLET (RELAY) 0-10V ANALOGIC OUTPUT 4-20mA ANALOGIC OUTPUT

19 TWO STAGE METER CE0-P AUTOMATON PRINTER ENTER MODE ZERO ON OFF SENSOR PULSES PRE-CUT VALVE FLOWMETERS PULSES SHUT-OFF VALVE

20 TWO STAGES PROGRAMMABLE METER CE0-P INTRODUCTION This series is specially designed to perform the most of the packaging processes, dosage, mixtures, loading and unloading of tanks... for chemical or petrochemical industry, food industry etc. They have been strongly built so they are resistant to those extreme conditions of industry. They are easy to use and they can be read from long distance. They are compatible with different type pulses inputs: REED, NAMUR, NPN, HALL, ENCODER etc. They can also work with turbine flowmeters, oval gear meters or electromagnetic flowmeters. SPECIFICATIONS 5 digits 12mm high Two stage batching 6 led to indicate work mode and state Partial totalizar 15 digits totalizar On/off from keyboard External starting Programming, pre-contact and pulse factor performance from keypad Data protection against electrical supply failures TTL output for printer. 2.400 bauds Pulse output open collector Maximum frequency input: 500Hz ELECTRICAL FEATURES AND CONNECTIONS Voltage: 220V dc, consumption 10W Auxiliar voltage: 12V ac Output: Output 1: 220 V DC, 100 W inductive load Output 2: 220 V DC, 100W (optional) PULSE INPUT TWO WIRES SENSORS (NAMUR-REED) 1. NEGATIVE 2. POSITIVE SENSORS POWER SUPPLY: 12V 20 MA 1. NEGATIVE 2. INLET 3. POSITIVE EXTERNAL STARTING OUTPUT 2 220 V DC OUTPUT 1 220 V DC EARTHING NET 220 V DC Input: NAMUR, REED, TRANSISTOR, NPN Ambient operating temperature: 0 55ºC 12 poles connector PRECONTACT (OPTIONAL) INDUCTOR CONTACTOR PUMP DESCRIPTION OF FRONTAL SIDE 5 DIGITS DISPLAY KEYPAD PULSE INPUT INDICATOR ON/OFF INDICATOR PROGRAM MODE INDICATOR MANUAL MODE INDICATOR TOTALIZER VALUE INDICATOR PRE-CONTACT VALUE INDICATOR CONSTANT VALUE PULSES KEYPAD DESCRIPTION ENTER Key to confirm data input and select commands ZERO To reset partial totalizer to zero Cursor movement along digits (left and right) ON OFF Key to start and stop manual or program mode Keys to change values (up to increase; down decrease) MODE Key to select mode

21 TWO STAGE METER CE0-P FLOWMETERS PULSES CONVERTER PULSES AUTOMATON PRE-CUT VALVE (Optional) SHUT-OFF PUMP SHUT-OFF VALVE