Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

LEDVANCE SUPERSTAR LED Downlight Gen 2

Installation Instructions

PIL0478 ISSUE 01/ 07/16

DOWNLIGHTS DEDICATED LED DOWNLIGHTS 017. DEDICATED LED DOWNLIGHTS 035. DOWNLIGHT FITTINGS

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Recessed Downlights. Zas

DALI 650mA LED Driver

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

650mA Phase Dimmable LED Driver

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

CLA IPART APPROVED PRODUCTS 2017

1000mA - 650mA Phase Dimmable LED Driver

Interior Utility Lights

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Beams Spot (15 to 21.5 ) Narrow Flood (24 to 28.5 ) Flood (38 to 39 ) Wide (60 to 65 ) Reflectors Aluminum reflectors

Product highlights. Retrofit only E26 adaptor Indoor / outdoor applications. 2 installation options Surface mount

15 DOWNLIGHTS - dedicated LED. Downlights DEDICATED LED DOWNLIGHTS DOWNLIGHT FITTINGS

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Idaho Profile System - Trimless

Product highlights. Retrofit only E26 adaptor Indoor / outdoor applications 90+ CRI. 2 installation options Surface mount

Light Source User Guide

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

LED Driver + Dimmer 5YEAR. 40W, 60W or 100W Constant Voltage LED Driver with Integrated Dimmer for Single Gang Box Mount FEATURES & BENEFITS

Installation Instructions: Eco Linear High Bay

Max Load. Max. Load. 100W 3-50VDC mA > 90% < 20% > 0.95 RFID P/N: XXXXXXXXXX CERTIFIED TO CSA STD. C22.2 NO.

EMERY SKY SUSPENDED LED LUMINAIRE

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

Adjustable Adjustable Large Adjustable Deep. Deep / Deep IP44 / Deep Adjustable Deep Gold Deep Black Gold. IP44 Square Square Adjustable / 1-2-3


LEDVANCE Downlight L DALI

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Fire Rated Downlights Product Catalogue

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

Linear Line Voltage LED Engine

LED 2/3/4ft T8 Tube 120V

MUST HAVES. in Quality lighting trusted by sparkies all over the globe.

DL-FLEX (-UP, -UP-HO, -UP-ULTRA)

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

LIGHTING January - March 2018 SEE OUR EXTENSIVE RANGE OF LAMPS AND FITTINGS OFFERS INSIDE

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

INSTALLATION & MAINTENANCE MANUAL HBL

Quad. Indoor recessed. ø1.69" 3.11" 2.36" 2.36" IP40 IP44. max 6W - max 500mA. max 6W - max 500mA. QD1232 N Black. B White.

High Bay Luminaire Series

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

5 m. length high efficiency adhesive flexible LED strip from the TROLL family Flexiled.

ROOF. design: Laura Andreini

Ardito LED - A2RSF SPECIFICATION SHEET. 2-1/2" Series. Ultra-Thin Profile Round Regressed Shower Trim SPECIFICATIONS

LED PROFILE - FLEXILED

Measurements are expressed in millimeters.

PANELS STRIPS LAMPS DOWNLIGHTS DRIVERS

diode led BLAZE 12V LED Tape Light 12VDC FEATURES Most popular lighting solution Closet-safe Wide CCT collection Cuttable every 1 inch QUICK SPECS

ECO EXT (DIMMABLE)

Light is reliable LED Lamps and Luminaires

HPNLS-HO. Installation Manual

MaxLite LED UTILITY WRAP FIXTURES

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

2017 STANDARD Products Inc. All Rights Reserved. Rev. January 11, 2018.

Constant Voltage TRIAC Dimmable Driver---120W Series. Features

LED Recessed Troffer Retrofit Kit

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

TJT120023ACxxxB TJT120023ACxxxC

Vision Profile System - Surface

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

Linear Line Voltage LED Engine

E-CORE LED TUBE GX16T-5 DATA SHEET 1 /5

LED DOWNLIGHTS. Prime K L LED Downlights with Separate LED Driver HIGH QUALITY COB TECHNOLOGY LED DOWNLIGHTS WITH SEPARATE LED DRIVER

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

Housing. Mounting EPA. Warranty. Listing

Flex Strip. Features & Benefits

CASCADE LED LIGHT BAR

CFP-LED Contractor Select Flat Panel. Installation Instructions

HIGH BAY HIGH LUMEN LED INDUSTRIAL LUMINAIRE

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

TJT120034ACxxxB TJT120034ACxxxC 120V LED DirectAC Engine and Retrofit Kits

TJT120015ACxxxB TJT120015ACxxxC 120V LED DirectAC Engine and Retrofit Kits

The Power Behind Energy

Light Source User Guide

TRUET5 EXT (DIMMABLE)

Luminaires - LED High Bay

Utah Profile System - Recessed

T8 Retrofit. LED Tubes

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

GP Dimming Panels 230 Volt (CE)

Transcription:

LEDLUX INFINITY MINI MARINE GRADE DIMMABLE LED DOWNLIGHT SKU# 170310, 170311 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions carefully before assembly, installation and use. Please keep instructions for future reference. Warranty This light fitting is covered by a 5 year warranty. The warranty is from date of purchase, not the date of installation. Please retain proof of purchase. The use of non-tested dimmers may damage your LED light fitting and will void your warranty. Warranty will be void if there is any damage due to improper usage or modification to the fitting. Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void warranty. Installation Requirements Before installation, check the installation location in the ceiling has access to a socket outlet which is connected to a wall light switch and dimmer. If it does not, please contact a licensed electrician to arrange installation of the socket outlet, wall light switch and dimmer before continuing. All wiring and installation of the light fitting must adhere to local and national wiring rules. eg. AS/NZS 3000:2007/Amendment 2:2012 Electrical installations. If unsure, please contact a licensed electrician. The fitting is IP44 rated only after it is fully installed, this must be maintained during installation. NOTE: The LED driver and the back part of the fitting is IP20 rated. Select a suitable location for installation; - The mounting point must support 2 times the weight of the fitting. - This fitting is suitable for indoor or outdoor use, provided that it is installed under cover or under eaves. This fitting is dimmable and has been tested at the date of publication with the dimmers listed in the specification section. The use of a LED dimmer such as the Lucci LEDlux SKU# 290998 dimmer is highly recommended. NOTE: For the best dimming range, use with the Lucci LEDlux SKU# 290998 dimmer and adjust the variable resistor at minimum and maximum dimming positions on the dimmer during the installation. NOTE: Dimming may cause buzzing sounds or a slight flicker. There may be slight delays with the LED light start up or slight uneven light performance when more than one LED light fitting is linked together, switched ON or dimmed. This is not a product fault and as such is not covered under warranty. NOTE: Some dimmers have a minimum load of 20W. Ensure the dimmer position is on the maximum setting before turning on the LED light and adjust the dimmer down to your desired light level. NOTE: Testing cannot account for installation variables such as variation in mains supply voltage, cable capacitance, electrical noise, transients, surges and ripple control signals (commonly found in NSW & QLD). NOTE: The information provided is correct to the best of Beacon Lighting s knowledge at the date of publication. This fitting has an insulating ceiling type IC-4 rating. Building insulation material can safely be exposed to temperatures up to 90 C continuously and may abut and cover the luminaire. (Please refer to the Clearance Information section and the IC-4 Rating section in this instruction manual for further details.) If loose fill insulation or thermal insulation is not fixed into position or if there are loose combustible materials (e.g. leaves or combustible materials stored in the roof space), a barrier or guard is required as per the Clearance Information section in this instruction manual. The LED driver must be placed at least 50mm away from the LED downlight module to allow for cooling. The LED driver must be placed above the insulation, DO NOT cover the driver with insulation to allow for cooling. (Please refer to the Clearance Information section in this instruction manual for further details.) 1 P a g e P u b l i s h e d o n 0 9 2017 v 3.0

The LED downlight module is only suitable for use with Lucci LED Driver Model#: TD011GIL-D030. The fitting must not be used if the diffuser on the LED downlight module has been damaged or cracked. Take care not to pull any electrical wires during unpacking as this may damage the connection. Lay out all the components on a smooth surface and make sure there are no components missing before assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement. Check whether the fitting has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work. Installation Directions 1. Remove all packaging material from the product and be careful not to throw away accessories that may be hidden within the packaging material. NOTE: Before installation, plug the fitting into a socket outlet to ensure the LED downlight is working correctly. 2. Cut an installation hole of Ø 85mm into the ceiling. Fig. 1 3. Join the connectors together and connect the fitting plug to the socket outlet. Fig. 2 4. Push the springs up and put the LED downlight module up through the cut-out hole and into the ceiling. Fig. 3 5. Ensure all the clearance values are maintained during and after installation of the LED downlight module, LED driver, thermal insulation, loose fill insulation, loose combustible materials and any structural members. Fig. 4 Please refer to the Clearance Information section and the IC-4 section in this instruction manual for further details. 6. After the installation, switch on the fitting to test all the lighting functions and enjoy your new lighting product. 2 P a g e P u b l i s h e d o n 0 9 2017 v 3.0

Clearance Information AS/NZS 3000 Wiring Rules LOCATION DISTANCE DESCRIPTION A B C D 50 mm (Minimum) 50 mm (Minimum) 0 mm (Abutted) 50mm Clearance between the top of the recessed luminaire and any combustible materials, building elements or objects above it. Clearance between the side of the recessed luminaire and any combustible materials, building elements or objects. Insulation can be abutted against the side of recessed luminaire and covered as per IC-4 Rating. See IC-4 Rating section for more details. Auxiliary equipment/driver/transformer must be placed 50mm away from the luminaire. It must be placed on top of thermal insulation and ensure it is not covered. IC Rating AS/NZS 60598.2.2 : 2016 1. A closed luminaire that allows building insulation to come into contact with its sides and to cover it. 2. Type IC-4 recessed luminaire can be used together with building insulation that can safely be exposed continuously to temperatures up to 90 C may abut and cover the luminaire; 3. The declared IC-4 rating is based on the default testing ambient temperatures 25 C according to the standard. RISK OF FIRE Required clearance from structural members and building elements SCB = 50 mm HCB = 50 mm Safety tips Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning or making any adjustment to the fitting. To avoid injury or damage to the fitting, ensure that power leads and screws are secure before connecting the power. Select a suitable location away from liquids and hazards. Ensure that the fitting does not come in contact with corrosive chemicals, etc. To clean, wipe with a damp clean cloth. Never soak the fitting with water. 3 P a g e P u b l i s h e d o n 0 9 2017 v 3.0

Troubleshooting PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Check your circuit breaker/safety switch box and turn on power to your circuit. Does not work. (New installation) Does not work. (Existing installation) Wiring loose or no power to the downlight. No power to the downlight. Unplug the downlight and test in a functional socket outlet with power. If the downlight does not switch on then contact your nearest Beacon Lighting store. If the downlight is working, have your licensed electrician check the wiring or socket outlet to the downlight. Check your circuit breaker/safety switch box and turn on power to your circuit. Contact your nearest Beacon Lighting store. Flickers when dimming. (New installation) Flickers when dimming. (Existing installation) Buzzing sound. Uneven light start up. Non-tested dimmer used. Some dimmers have a variable loading adjustment function. eg. Lucci LEDlux SKU# 290998 dimmer. This may not have been adjusted during the installation of the dimmer. Dimmer position on low. Non-tested dimmer used. Dimmer position on low when switched on. Check the dimmer used. Ensure the dimmer used is on the list of tested dimmers in this manual. The variable resistor needs to be adjusted to suit the downlight load to reduce the flickering. Ensure the dimmer position is on the maximum setting before turning on the downlights and adjust the dimmer down to your desired light level. Check the dimmer used. Ensure the dimmer used is on the list of tested dimmers in this manual. Ensure the dimmer position is on the maximum setting before turning on the downlights and adjust the dimmer down to your desired light level. 4 P a g e P u b l i s h e d o n 0 9 2017 v 3.0

Specifications V3 SKU # 170310 170311 Colour 316 grade Stainless Steel 316 grade Stainless Steel Rated Voltage INPUT: 220-240V~ 50Hz, OUPUT: 29-34VDC, 0.3A, constant current, Rated Wattage 11W LED Specs Bridgelux LED, 3000K, 700 lumens Bridgelux LED, 4000K, 700 lumens Highly Recommended Dimmers Tested Dimmers Dimmer Information Lucci LEDlux SKU# 290998 DIGINET LED Smart MEDM; Clipsal 31E2RUDM, 32E450TM, 32E450UDM, 31E2PUDM and 32ELEDM; Lucci LEDlux SKU#290997 Weight Cut-out Size 0.32kg Φ85mm IP Rating Dimensions Serviceable Parts LED Driver Model # IP44 for LED downlight module D:105mm x H:37.5mm LED downlight module and LED driver are both serviceable. TD011GIL-D030 5 P a g e P u b l i s h e d o n 0 9 2017 v 3.0