PFA Eddysonic flowmeter

Similar documents
Digital Flow Switch (Sensor Part) Operation Manual

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

SIGNET 7002 Vortex Flow Sensor ENGLISH

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

Differential Pressure Transmitter

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

Helical Flow. HF-GC/GP Series

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?

Read and understand this manual for safely usage.

2-Color Display High-Precision Digital Pressure Switch

Inline Ultrasonic Flowmeter

An Innovative Flow Sensor

A Member of the. Integrated Metering Technologies

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

A Member of the. Integrated Metering Technologies

Direct Coupled Damper Actuator Model MY6050A1001

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Positive displacement flowmeter for continuous flow measurement

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Vortex Eggs Delta Flowmeter

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

Fundamental Training. Flow Con t

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540

Digital display Pressure range ON/OFF output Linear output Model

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Paddle-wheel flow controller with optical principle for On/Off control

2-Color Display High-Precision Digital Pressure Switch

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

General Specifications

Magnetic Inductive Flow

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

INSERTION flowmeter with paddle wheel, ELEMENT design

MODEL 1100 TURBINE FLOW METER

Series 8000 Vortex Flow Meter

RCM - Direct Reading Flowmeters

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

EX Series. Electric Actuators for Ball and Butterfly Valves

TOWA SEIDEN INDUSTRIAL CO., LTD.

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Series 10-ZSE40A(F)/10-ISE40A

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Model Pressure range ON/OFF output Linear output

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Model 1100 Turbine Flow Meter

Digital Flow Switch for Deionized Water and Chemicals

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

CATALOG KTLU. Vortex Flowmeter

Differential Pressure Sensor


Hydro-Flow Model 2200 Installation and Operation Guide B

Pressure Transmitters

PRODUCT SPECIFICATION. Stack Lights. Series.

F-2600 SERIES INLINE VORTEX FLOW METER

Vacuum pump system type

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Paddle-wheel flow controller for On/Off control

INSERTION flow sensor for continuous flow measurement

Direct Coupled Damper Actuator Model MY9050A1001

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Technical information for LFU20-Z07-3A-X2

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

NIDEC COPAL ELECTRONICS CORP. 1 / 7. Model No. Issuing Date

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Cylindrical Inductive Proximity Sensor GX-M SERIES

35 35A 50 50A 1 Single phase. Solid state power controller

Vortex Flow Meter Model DVH

Read and understand this manual for safely usage.

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Multivariable Vortex Flow Meter

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

Magnetic Inductive Flowmeter EP / UMF2 (B)

SRT1000 Series THERMAL FLOWMETER

DIGITAL RCD(ELCB) TESTER

CATALOG KVFN. Vortex Flowmeter

Diaphragm Valves Type 15

유량계전문제조업체. Electro Magnetic FLOWMETER

MAIN FUNCTION FEATURES. . D = v t /2

Large flow rate with compact body

Model Pressure range ON/OFF output Linear output

Transcription:

PFA Eddysonic flowmeter CE marking Approval Conforms to the CE marking The Eddysonic Flowmeter is a flowmeter for fluids that detects the vortex street using the ultrasonic sensor mounted on the outside of it. Its part in contact with fluids is entirely molded with PFA to provide no movable part. Features Because PFA Flowmeters measure Karman Vortexes using a non-contact ultrasonic sensor method,they contain no moving parts such as flippers & floats, thus eliminating particle generation. High and Low alarm boundaries can be set to any level using selector keys. Lightweight and compact, Flowmeters can be mounted directly onto your existing piping systems. Monitor attached series (ESF) and monitor unattached series (ESL) are available depending on customer's application. Operation principle If a fluid flows past a shedder body, a regular pattern of vortices called Karman Vortex street alternately trails aft in the wake. The ultrasonic wave oscillating time varies proportional to the vortex shedding frequency. We can obtain the measured flow by detecting any changes in ultrasonic wave oscillating time. Flow Housing Receiver Ultrasonic Waves Shedder Body Karman Vortex Transmitter Caution Pressure at downstream side To prevent the occurrence of cavitations, the pressure value at the downstream side should be more than one obtained from the following formula. Pd2.7P.3P 0 Pd Pressure values at the downstream side.kpa abs PPressure loss values.kpa P 0 Vapor pressure values of fluids.kpa abs *Cavitations Phenomenon that the liquid evaporates, generating air bubbles, when the liquid pressure drops to the saturated vapor pressure or below.

ESF Series CE marking Approval Conforms to the CE marking Ordering Information ESF- stube Diameter 0Ø9.3Ø6.3 Ø2.7Ø9.3 ESF-0ESF- Specifications Available fluid Model Flowmeter Range Indicating Flow Rate Measurement Accuracy Operating Environmental Temperature Operating Fluid Temperature Fluid Pressure Tube Diameter Wetted Parts Mounting Positions Analog Load Resistance Excitation Voltage/Current Pulse Pulse Unit Pulse Range High&Low Excitation Voltage/Current boundary LED indication Power Supply Current Consumption Cable CE marking approval ESF-0 ESF- Fluids not corrosive or permeable against fluorocarbon resin. (Please contact us for your operating fluids.) 0.3.r/min 0.04.0r/min % F.S 60 C 8 C Ø9.3Ø6.3 PFA Horizontal, Vertical or Diagonal (Not vertical in drop position) DC420mA 00Ω or Less NPN Open collector Max.DC30V/80mA 0mr/P ms NPN Open collector Max.DC30V/80mA LO turns off : less than Low boundaryhi, LO turns on : within High & Low boundary HI turns off : more than High boundary Max.800kPa2 C DC240% 20mA or Less 6r/min 0.08.0r/min 2.% F.S 60 C 8 C Ø2.7Ø9.3 Instructions on Wiring * When wiring, be sure to make the appropriate connection in reference to below figure. Main Circuit Gray F.G Recorder High/Low Boundary Shielding DC24V Power Supply Integrating Flowmeter (Counter) Name of Signal DC24V Power Supply 0V Power Supply 420mA (+) 420mA (-) Pulse (+) High / Low Boundary (+) Color Gray * and blue leads are connected each other within the circuit.

Dimensions ESF-0 : DC24V Power Supply : 420mA () : 420mA () : Pulse () Gray : High/Low Boundary () 9. Indicating 3/8 PFA tube flow rate Ø9.3Ø6.3 62 2-M3 P0. 33. 2. 2 Low Alarm Selector Mode/Down key High Alarm Selector Mode/Up key High Alarm Indicator Lamp Low Alarm Indicator Lamp 6.6 9 ESF- : DC24V Power Supply : 420mA () : 420mA () : Pulse () Gray : High/Low Boundary () 9. Indicating flow rate /2 PFA tube Ø2.7Ø9.3 62 2-M3 P0. 33. 2. 2 Low Alarm Selector Mode/Down key High Alarm Selector Mode/Up key High Alarm Indicator Lamp Low Alarm Indicator Lamp 6.6 20 Flow characteristic To prevent the occurrence of cavitations, the pressure value at the downstream side should be more than one obtained from the following formula. Pd2.7P.3P 0 Pd Pressure values at the downstream side.kpa abs PPressure loss values.kpa P 0 Vapor pressure values of fluids. kpa abs Pressure LossPkPa 00 0 ESF-0 ESF- * Cavitations Phenomenon that the liquid evaporates, generating air bubbles, when the liquid pressure drops to the saturated vapor pressure or below. 0 Flow Rater/min 00 2

ESF Series CE marking Approval Conforms to the CE marking Ordering Information ESF-20- ESF-2 NonBase unattached B Base attached stube DiameterØ9Ø6 stube DiameterØ2.4Ø22.2 ESF-20ESF-2 Specifications Available fluid Model Flowmeter Range Indicating Flow Rate Measurement Accuracy Operating Environmental Temperature Operating Fluid Temperature Fluid Pressure Tube Diameter Wetted Parts Mounting Positions Analog Load Resistance Excitation Voltage/Current Pulse Pulse Unit Pulse Range High&Low Excitation Voltage/Current boundary LED indication Power Supply Current Consumption Cable CE marking approval ESF-20- ESF-2 Fluids not corrosive or permeable against fluorocarbon resin. (Please contact us for your operating fluids.) 240r/min 0.044r/min.%F.S 60 C 8 C* Max.600kPa2 C Ø9Ø6 PFA Horizontal, Vertical or Diagonal (Not vertical in drop position) DC420mA 00Ω or Less 0mr/P NPN Open collector Max.DC30V/80mA ms NPN Open collector Max.DC30V/80mA LO turns off : less than Low boundaryhi, LO turns on : within High & Low boundary HI turns off : more than High boundary DC240% 20mA or Less 30r/min 0.04r/min 2.%F.S 60 C 8 C Max.40kPa2 C Ø2.4Ø22.2 00mr/P * ESF-20 : When fluid temperature more then 70 C, flow range comes to 640r/min. Instructions on Wiring * When wiring, be sure to make the appropriate connection in reference to below figure. Main Circuit Gray F.G Recorder High/Low Boundary Shielding DC24V Power Supply Integrating Flowmeter (Counter) Name of Signal DC24V Power Supply 0V Power Supply 420mA (+) 420mA (-) Pulse (+) High / Low Boundary (+) Color Gray * and blue leads are connected each other within the circuit. 3

Dimensions ESF-20- : DC24V Power Supply : 420mA () : 420mA () : Pulse () Gray : High/Low Boundary () 9. D E 4-Ø 3/4 PFA tube Indicating flow rate Ø9.0Ø.9 High Alarm Indicator Lamp 62 G F Low Alarm Selector Mode/Down key High Alarm Selector Mode/Up key Low Alarm Indicator Lamp Model A B ESF-20 6 6.6 ESF-20-B 6 6.6 C 8 228 A B C Mounting dimension table Model D E F G Ø ESF-20-B 34 26 78 70 4. ESF-2 : DC24V Power Supply : 420mA () : 420mA () : Pulse () Gray : High/Low Boundary () Low Alarm Selector Mode/Down key High Alarm Selector Mode/Up key 9. Indicating flow rate PFA tube Ø2.4Ø22.2 62 High Alarm Indicator Lamp Low Alarm Indicator Lamp 26 7.6 32 2-M4 P0.7 44 24 0 Flow characteristic To prevent the occurrence of cavitations, the pressure value at the downstream side should be more than one obtained from the following formula. Pd2.7P.3P 0 Pd Pressure values at the downstream side.kpa abs PPressure loss values.kpa P0 Vapor pressure values of fluids. kpa abs Pressure LossPkPa 00 0 ESF-20 ESF-2 * Cavitations Phenomenon that the liquid evaporates, generating air bubbles, when the liquid pressure drops to the saturated vapor pressure or below. 0 Flow Rater/min 00 4

ESL Series Ordering Information CE marking Approval Conforms to the CE marking ESL- stube Diameter 6-2.Ø6.3Ø3.9 0 Ø9.3Ø6.3 Ø2.7Ø9.3 ESL-0ESL- Features This series is no monitor, lightweight and compact, so it can be parallel piping in closely-spaced, and it is appropriate for equipment compact design. ESF is simple structure to povide cleanliness and no-moving parts such as flipper because Karman vortex is detected by ultrasonic sensor. Specifications Model Available fluid Flowmeter Range Measurement Accuracy Operating Environmental Temperature Operating Fluid Temperature Fluid Pressure Tube Diameter Wetted Parts Mounting Positions Analog Load Resistance Excitation Voltage/Current Pulse Pulse Unit Pulse Range Power Supply Current Consumption Cable CE marking approval ESL-6-2. ESL-0 ESL- Fluids not corrosive or permeable against fluorocarbon resin. (Please contact us for your operating fluids.) 0.42.r/min 0.3.r/min 2.6r/min 2% F.S 60 C 8 C Max.800kPa2 C Ø6.3Ø3.9 Ø9.3Ø6.3 PFA Horizontal, Vertical or Diagonal (Not vertical in drop position) DC420mA 00Ω or Less NPN Open collector Max.DC30V/80mA 0mr/P ms DC240% 0mA or Less Ø2.7Ø9.3 Instructions on Wiring * When wiring, be sure to make the appropriate connection in reference to below figure. Main Circuit F.G Recorder Shielding Integrating Flowmeter (Counter) DC24V Power Supply * and blue leads are connected each other within the circuit. Name of Signal DC24V Power Supply 0V Power Supply 420mA (+) 420mA (-) Pulse (+) Color

Dimensions ESL-6-2. 74 6. 4-Ø4. 94 ESL-0 4-Ø4. 74 6. 9. 28 29.6 2. 6 Ø9.3Ø6.3 20 42. 43.3 9 ESL- 74 6. 9. 28 29.6 9. 28 29.6 : DC24V Power Supply : 420mA () : 420mA () : Pulse () 2. 6 Ø6.3Ø3.96 20 42. 43.3 : DC24V Power Supply : 420mA () : 420mA () : Pulse () 4-Ø4. : DC24V Power Supply : 420mA () : 420mA () : Pulse () 2. 6 Ø2.7Ø9.3 20 42. 43.3 20 Flow characteristic To prevent the occurrence of cavitations, the pressure value at the downstream side should be more than one obtained from the following formula. Pd2.7P.3P 0 Pd Pressure values at the downstream side.kpa abs PPressure loss values.kpa P0 Vapor pressure values of fluids. kpa abs Pressure LossPkPa 200 00 0 ESL-0 ESL- * Cavitations Phenomenon that the liquid evaporates, generating air bubbles, when the liquid pressure drops to the saturated vapor pressure or below. 0 Flow Rater/min 00 6

Kinetic viscosity of fluids - Minimum flow rate Kinetic viscosity of fluids 0-6 m 2 /s Minimum flow rate of ESL-6-2.r/min Minimum flow rate of ESF-0.ESL-0r/min Minimum flow rate of ESF-r/min Minimum flow rate of ESL-r/min Minimum flow rate of ESF-20-r/min Minimum flow rate of ESF-2r/min 0.4 0. 2. 2 2 0.8 2 4 0 * The minimum flow rates of the fluids,of which kinetic viscosity are more than 20-6 m 2 /s, are the theoretical values and may be different from the actual values. 3.2. 3 7. 6 4.6 2 4 0 8 20 2.0 2. 2. 0 2 6 2.4 3 6 2 30 7 7 4 3 Maximum flow rate r/min 2. 3. 6 6 40 30 Safety Instructions Before you use this product,carefully read this manual for safety operation. We are not liable to any accident caused by neglect of our instructions. Use this product in accordance with its specification. Confirm the compatibility of the type of fluid to be used and the material of the part in contact with fluid before using this product. Eddysonic Flowmeter is designed for indoor-only use. Do not apply this product to outdoor use. Before wiring, be sure to turn off the power supply. Neglecting this may result in electric shock. Whenever using a commercial switching regulator as power supply, ground it to the frame ground (F.G.) terminal. Any noise-generating equipment (such as switching regulators or inverter motors) used close to the Flowmeter should be grounded to an F.G. terminal. Avoid the parallel wiring or the sharing of wiring tube with any high-voltage cable and power cable. Doing so may cause induction, resulting in malfunction of the product. Always use Eddysonic Folwmeter within the rated flow meter range. Make sure that power input does not exceed the rated supply limit. Before tubing, confirm the correct flow direction by checking the arrow direction of "-" marked on the side of flowmeter unit. Incorrect tubing system may result in personal injury due to liquid leakage caused by damage of flowmeter unit. Never disassemble this product. Neglecting this caution may result in abnormal operation. Before mounting, align the axes of tubes on both sides to avoid excessive stress to the flowmeter. The or side's tube of which bore diameter is smaller than that of flowmeter may generate an error in measurement. The tube can be mounted in horizontal, vertical and diagonal. However, in any case, the tubing system must be filled with the fluid at all times. We recommend the vertical tubing system. To prevent gas-liquid two-phase flows, design the tubing system in which the measured fluids flow to the upward direction. (bottom-top) The flowmeter may be disable to measure the flow mixed with gas-liquid two-phase flows or air bubbles. Install the flowmeter so that air bubbles do not flow into it or get trapped inside its tube. When using flowmeter, be sure to release the air inside its tube. Design straight-tube parts on both sides of flowmeter. The straight-tube length of side must be at least 7 times longer than the inner bore diameter, and that of side must be at least times longer than the inner bore diameter. Do not mount the flowmeter in the places that may provide high temperature gradients or sharp temperature changes. Large ripples of bellows the ripples by using dampers or similar devices may result in errors in measurement. Minimize the ripples by using dampers or similar devices. Do not use this product for liquid containing foreign substances. Such usage may degrade the performance of the product. Please handle abrasive and coagulable fluids with care not to cleave. Such fluids may degrade the system performance. ESF, ESL series are not applicable with ozone water. 7

Digital Flow Monitor DV-4000 Series Features Flowmeters DV-40 It is possible to be remote display using with Karman flowmeter (ESF, ESL) Panel mounting type : Size D 4824 Face of operating parts : IP 66 acquired Analog output : DC 420mA High & Low limit output and Relay contact contained. Specifications Power Supply Input High/Low Limit Analog Accuracy Operating/strage temperature DC24V0%, Current consumption 80mA DC420mA HI.LO limit setting points (Configurable) Relay contact AC220V/DC30V, A (Resistive load) DC420mA, supports 0 (-00) to the rated flow Allowable load resistance 0000Ω 0.3%F.S (At ambient temperature 23 C) -0 C0 C, 90%RH or less (No condensing) -0 C4 C (When closely-attached) -20 C60 C (Storage temperature) Corresponding Monitor Table Eddysonic Flowmeter Corresponding Monitor Model Model Indicating Flow Rate ESL-6-2. DV-20A 0.02.r/min ESF-0 ESF- ESF-20 ESF-2 ESL-0 ESL- DV-400 DV-40 DV-4200 DV-420 0.03.r/min 0.06.0r/min 0.040.0r/min 0.030.0r/min Terminal Description and Connection Dimensions 02 4 Packing 34.2 24 22 Power Unit 48 4 98 Fixing Flame 22.2 0.3 0 4 0. 0 Panel Cutout Dimensions Panel Thickness8 8

Notes on product warranty This product is warranted for a period of one () year from the date of delivery by Surpass Industry Co.,Ltd. Within this period, we will replace the product with any defect that is undoubtedly due to design or workmanship. This warranty does not apply to the followings. Any defective products due to mishandling or improper usage. Any defective products due to alteration or improper repair by other than Surpass Industry. Any defective products due to a natural disaster, riot or accident that we are not liable to. This product is not designed for use with any equipment or in the system that is operated under conditions that could be critical to human life. The data described in the catalog is a reference value, not a guarantee value. Description of marks used in this manual Caution Indicates a potential hazardous situation that, if not avoided, could result in personal injury or damage to the property. Indicates proper procedures and instructions to avoid any damage to the product and use it properly. We take an order for customizing the product according to your specific needs. For more information, please contact us. The contents of this manual may subject to future modifications without prior notice. We made best efforts in completing this manual. However, if you find any questionable areas, mistakes or omissions, please contact us. We are not liable to any consequential influence due to usage of this product. We are not liable to any damage due to incorrect usage or unauthorized usage of product. Using inappropriate O-ring material may cause leakage. Before specifying your O-ring material, make sure that it is compliant with your fluid type and corrosion resistance. Surpass Industry Co., Ltd. Head office 2203 Shimooshi, Gyoda-City, Saitama-Pref. Zip 36-0037 Tel.+8-48-4-9767 Fax.+8-48-4-9906 Distributor EF-CN-0703-000