BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

Similar documents
TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale

WP Series Hydraulic & Pneumatic Flow Monitors Illustrated Price List

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

EZ-View. Flow Meters ISO CERTIFIED 9001

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

COMPANY. Flow Rate Alarms Installation, Operating & Maintenance Manual

Flow Measurement Technology Training

KEL DIFFERENTIAL PRESSURE FLOWMETERS

Flow-Alert Flow Switches (Micro Switch)

PSF50 Paddle flow switch

Installation, Operation & Maintenance Manual

DPT TARGET TYPE FLOWMETERS

2100 Turbine Flow Sensor

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

PISTON STYLE GAUGE. Mid-West Instrument

ELECTRONIC CONTROLLER

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Dissolved Oxygen Measurement System with Air Blast Cleaner

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

1100 Series Piston Type Differential Pressure Gauges

O.E.M GAUGES. For Installation and Operation Manuals Please Visit: Mid-West Instrument

RCM. Direct Reading Flowmeter. for Liquids or Gases

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

KEL. Heavy Duty Differential Pressure Flowmeters

Low Profile Insertion Vortex

COMPANY. Liquid Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:FLOWLIQUIDMETERMAN082516

Table of Contents. Proportional & Precision Regulator Instrumentation

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

THE INSIDE STORY OF THE QPV OR MPV:

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122

MODEL 106F TEFLON LIQUID FLOW SENSOR

Flow Monitors Excess Flow Valves Flow Meters. ChemTec.com

Model FVP General Specification. Flanged Vortex Plate. Product Features

1000 Series Piston Type Differential Pressure Gauges

Hot Tap Insertion Vortex

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

RCM - Direct Reading Flowmeters

Product Summary. Flow Meters. Hydraulic Diagnostic Products

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Variable Area Flowmeters Ori-Flowrator TM Meters

Flow Meters. Installation, Operation & Maintenance Manual.

G2 Industrial Grade Meters

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

Signet 2551 Magmeter Flow Sensor

Variable Area Flow Meters Improve productivity and reduce maintenance costs through reliable flow metering and process control technology.

M Series. Feature rich flow meter and switch with in-line. flow

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

NBK-M - Economical Level Indicator

King Instrument Company opened its doors in 1983 with one major goal:

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

LTX RF LEVEL SENSOR. Instruction Manual

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Model DFX Doppler ultrasonic flow meter

Model 124 Filter Minder & Model 124

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

INDUSTRIAL DYNAMICS CO

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Vortex Plate. Model VP General Specification. Product Features

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

UNIVERSAL Flow Meters

CAUTION CAUTION IN-LINE LIQUID FLOW METER INSTALLATION & MAINTENANCE INSTRUCTIONS FORM # HLIT205-2G

M-200 Series. High flow, Adjustable flow switch with right-angle flow

TYPE MP OSCILLATING PISTON FLOWMETER

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

mass flowmeter for compressed air

Precision Regulators.

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT

Flow meters, Flow switches and Flow transmitters

Flowmeters & Monitors

Type Type 1001 Transducers. I/P & E/P Transducers

TELEDYNE HASTINGS INSTRUMENTS

MINI-NBK ECONOMICAL LEVEL INDICATOR

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

BULLETIN NO.ELEC IM240/11A Supersedes IM240/10A

Model Q45H/ Residual Chlorine Monitor...

NT ELECTRONIC FLOWMETER, MODEL 4400

General Design Features

Ultra Compact UHP Liquid Flow Controllers

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

Miniature I/P, E/P Transducer

digital flow meters BW Digi-Meter F-1000

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

DTK. OEM Pelton Wheel Flow Sensor

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT

Numatics 2003 Rev. 11/03 PDFPRECISION-1

Transcription:

BASIC Data Sheet No. B-699 IN-LINE LIQUID FLOW RATE MONITORS CHOICE OF THREE MATERIALS OF CONSTRUCTION Select from aluminum, brass or stainless steel to meet system and liquid requirements. UNRESTRICTED MOUNTING Allows the designer to install the monitor in any orientation horizontal, vertical or inverted. SUPERIOR EXTERIOR DESIGN Weather-tight for use outdoors and/or on systems where wash downs are required. GOOD VISCOSITY STABILITY A sharp-edged orifice provides excellent measurement stability to a minimum of 5 SSU. RUGGED AND RELIABLE Designed as a hydraulic service tool, this monitor will provide years of maintenance-free performance. FOR 1/ INCH PIPE SIZES HIGH PRESSURE OPERATION The magnetically coupled follower design allows operation to 6 PSIG and use with opaque liquids. TWENTY-THREE DIFFERENT PORTS AVAILABLE Standard selection of NPT, SAE and BSP ports reduces the amount of adapters required for installation. LOW COST PRECISION Mid-scale measuring accuracy within ±.5%. Full-scale accuracy within ±%. ENGINEERING SPECIFICATION THE IN-LINE FLOW RATE MONITOR SHALL: use the variable annular orifice technique with compression spring recovery. not require inlet or outlet straight plumbing, or require vertical pipe mounting. have a measuring accuracy of ±.5% of full scale in the center third of the measuring range, and ±% of full scale accuracy over the entire flow measuring range. have a stainless steel sharp-edged orifice. have a weather-tight external construction. be Lake Monitors No. B _

IN-LINE LIQUID FLOW RATE MONITORS PRESSURE DIFFERENTIAL VS FLOW RATE 3 5 SERIES 5 MONITORS (1-1/ - ) -99 15-88 1-75 5-5 -5 6 8 1 1 1 16 MATERIALS OF CONSTRUCTION (WETTED COMPONENTS) High-pressure casing, Aluminum Brass #3 Stainless Steel end ports and tapered shaft Seals Buna-N (STD), EPR, Buna-N (STD), EPR, Viton with Teflon backup Viton or Kalrez Viton or Kalrez (STD), Buna-N, EPR or Kalrez Transfer Magnet Teflon coated Alnico Teflon coated Alnico Teflon coated Alnico Floating Orifice Disk Stainless Steel Stainless Steel Stainless Steel All other internal parts Stainless Steel Stainless Steel Stainless Steel MATERIALS OF CONSTRUCTION (NON-WETTED COMPONENTS) Window Tube Polycarbonate (STD), Polycarbonate (STD), Polycarbonate (STD), Pyrex Pyrex Pyrex Window Seals Buna-N (STD), Teflon Buna-N (STD), Teflon Buna-N (STD), Teflon Teflon is a registered trademark of dupont de Nemours & Co. Viton and Kalrez are registered trademarks of Dow DuPont Elastomers. SERIES MONITORS (3/ - 1 ) 16 1 1 1 8 6-5 - -3-15 -5 1 3 - -1 Measuring accuracy: Repeatability: Flow measuring range: Maximum operating pressure: ±.5% of full-scale in the center third of the measuring range; ±% of full-scale over the entire scale range. ±1% of full-scale.5-15 GPM (.-56 LPM) aluminum and brass monitors: 35 PSIG ( Bar) stainless steel monitors: 6 PSIG (1 Bar) Maximum operating temperature: ºF (116ºC) Note: for operation to 6ºF (316ºC), see our High Temperature Data sheet. Pressure differential: see graphs Standard calibration fluids: PERFORMANCE Oil monitors: DTE 5 @ 11ºF (3ºC),.873 sg Water monitors: tap water @ 7ºF (1ºC), 1. sg SERIES 3 MONITORS (1/ - 1/ ) MECHANICAL 1 1 1 8 6-15 -1-5 - -1 6 8 1 1 1 16 A SIZE CODE DIM SERIES 3 SERIES B SERIES 5 SERIES 5 A 1-7/8-3/8 (8mm) (6mm) 3-1/ (9mm) 3-1/ (9mm) B 6-9/16 7-5/3 (167MM) (18mm) 1-1/8 (58mm) 1-5/8 (3mm) PORT NPTF: 1/, 3/8, 1/ NPTF: 3/, 1 SIZES SAE: #6, #8, #1 SAE: #1, #16 BSP: 3/8, 1/ BSP: 3/, 1 NPTF: 1-1/, 1-1/ SAE: # BSP: 1-1/ NPTF: SAE: #3 BSP: 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com Note: Consult factory for SAE brass monitor requirements.

PNEUMATIC Data Sheet No. G-699 PNEUMATIC FLOW RATE MONITORS FOR 1/ INCH PIPE SIZES CHOICE OF THREE MATERIALS OF CONSTRUCTION Select from aluminum, brass or stainless steel to meet system and media requirements. UNRESTRICTED MOUNTING Allows the designer to install the monitor in any orientation horizontal, vertical or inverted. SUPERIOR EXTERIOR DESIGN Weather-tight for use outdoors and/or on systems where wash downs are required. MULTI-USE These versatile monitors are used to verify air compressor outputs and to test pneumatic machinery and tools for proper air consumption. RUGGED AND RELIABLE These monitors are constructed with all metal pressure vessels, allowing safe, permanent, installation in industrial systems. HIGH PRESSURE OPERATION The magnetically coupled follower design allows operation to 1 PSIG. TWENTY-THREE DIFFERENT PORTS AVAILABLE Standard selection of NPT, SAE and BSP ports reduces the amount of adapters required for installation. LOW COST PRECISION Mid-scale measuring accuracy: within ±.5%. Full-scale accuracy: within ±%. ENGINEERING SPECIFICATION THE PNEUMATIC IN-LINE FLOW RATE MONITOR SHALL: use the variable annular orifice technique with compression spring recovery. not require inlet or outlet straight plumbing, or require vertical pipe mounting. have a measuring accuracy of ±.5% of full scale in the center third of the measuring range, and ±% of full scale accuracy over the entire flow measuring range. have a stainless steel sharp-edged orifice. have a weather-tight external construction. be Lake Monitors No. G _.

PRESSURE DIFFERENTIAL VS FLOW RATE Lake Monitors Order Number: (see guide to standard monitor numbers) G3A - AB - 5 Series 3 Flow rate: 5-5 SCFM PNEUMATIC FLOW RATE MONITORS MATERIALS OF CONSTRUCTION (WETTED COMPONENTS) High-pressure casing, Aluminum Brass #3 Stainless Steel end ports and tapered shaft Seals Buna-N (STD), EPR, Buna-N (STD), EPR, Viton with Teflon backup Viton or Kalrez Viton or Kalrez (STD), Buna-N, EPR or Kalrez Transfer Magnet Teflon coated Alnico Teflon coated Alnico Teflon coated Alnico Floating Orifice Disk Stainless Steel Stainless Steel Stainless Steel All other internal parts Stainless Steel Stainless Steel Stainless Steel SERIES 5 MONITORS (1-1/ - ) 3 35 5 3 5 15-75 -88 1 15-5 -88 1-75 5 5-5 -5 6 8 1 1 1 6 8 1 1 1 5 5 15 15 FLOW RATE: SCFM@1 PSIG SERIES MONITORS (3/ - 1 ) -3-3 - -5 - FLOW RATE: SCFM@1 PSIG -99-5 1-15 1-15 -1-5 5 5 - -5-5 - - - -1-5 1 1 3 3 5 6 5-99 MATERIALS OF CONSTRUCTION (NON-WETTED COMPONENTS) Measuring accuracy: Repeatability: Flow measuring range: Pressure differential: Maximum operating pressure: Window Tube Polycarbonate (STD), Polycarbonate (STD), Polycarbonate (STD), Pyrex Pyrex Pyrex Window Seals Buna-N (STD), Teflon Buna-N (STD), Teflon Buna-N (STD), Teflon Teflon is a registered trademark of dupont de Nemours & Co. Viton and Kalrez are registered trademarks of Dow DuPont Elastomers. PERFORMANCE ±.5% of full-scale in the center third of the measuring range; ±% of full-scale over the entire scale range ±1% of full-scale.-1 SCFM (1.-7 LPS) see graphs aluminum and brass monitors: 6 PSIG ( Bar) stainless steel monitors: 1 PSIG (7 Bar) Maximum operating temperature: ºF (116ºC) Note: for operation to 6ºF (316ºC), see our High Temperature Data sheet. Standard calibration fluids: air @ 7ºF (1ºC), 1. sg and 1 PSIG (6.8 Bar) MECHANICAL SERIES 3 MONITORS (1/ - 1/ ) 3 55-1 -15 153 1-5 -1 - -5 5-1-1 1 6 831 1 1 5 16 FLOW RATE: SCFM@1 PSIG 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com A SIZE CODE DIM SERIES 3 SERIES A 1-7/8-3/8 (8mm) (6mm) B 6-9/16 7-5/3 (167MM) (18mm) PORT NPTF: 1/, 3/8, 1/ NPTF: 3/, 1 SIZES SAE: #6, #8, #1 SAE: #1, #16 BSP: 3/8, 1/ BSP: 3/, 1 Note: Consult factory for SAE brass monitor requirements. For specific pneumatic application information, please see our Pneumatic Sizing Guide. B SERIES 5 3-1/ (9mm) 1-1/8 (58mm) NPTF: 1-1/, 1-1/ SAE: # BSP: 1-1/ SERIES 5 3-1/ (9mm) 1-5/8 (3mm) NPTF: SAE: #3 BSP:

HIGH TEMPERATURE Data Sheet No. H-699 HIGH TEMPERATURE FLOW RATE MONITORS MULTI-APPLICATION Uses include: barrel heating fluids, thermal transfer fluids and non-steam water monitoring. THREE MATERIALS AVAILABLE Select from aluminum, brass or stainless steel construction to meet system requirements. UNRESTRICTED MOUNTING Allows the designer to install the monitor in any orientation horizontal, vertical or inverted. GOOD VISCOSITY STABILITY A sharp-edged orifice provides excellent measurement stability to a minimum of 5 SSU. RUGGED AND RELIABLE Designed as a hydraulic service tool, this monitor will provide years of maintenance-free performance. FOR 1/ INCH PIPE SIZES HIGH PRESSURE OPERATION The magnetically coupled follower design allows operation to 6 PSIG and use with opaque liquids. TWENTY-THREE DIFFERENT PORTS AVAILABLE Standard selection of NPT, SAE and BSP ports reduces the amount of adapters required for installation. LOW COST PRECISION Mid-scale measuring accuracy within ±.5%. Full-scale accuracy within ±%. ENGINEERING SPECIFICATION THE HIGH TEMPERATURE IN-LINE FLOW RATE MONITOR SHALL: use the variable annular orifice technique with compression spring recovery. not require inlet or outlet straight plumbing, or require vertical pipe mounting. have a measuring accuracy of ±.5% of full scale in the center third of the measuring range, and ±% of full scale accuracy over the entire flow measuring range. have a stainless steel sharp-edged orifice. have a minimum temperature rating of: H-series ºF (ºC) or J-series 6ºF (315ºC). be Lake Monitors No. H _ for ºF (ºC) applications or J _ for 6ºF (315ºC) applications.

PRESSURE DIFFERENTIAL VS FLOW RATE 3 5 SERIES 5 MONITORS (1-1/ - ) 15-88 1-75 5-5 -5 6 8 1 1 1 16 1 1 1 16 1 1 1 8 6-5 - -3-15 -5-99 SERIES MONITORS (3/ - 1 ) - -1 1 3 SERIES 3 MONITORS (1/ - 1/ ) 8 6-15 -1-5 - -1 6 8 1 1 1 16 MATERIALS OF CONSTRUCTION (WETTED COMPONENTS) Measuring accuracy: Repeatability: Flow measuring range: Pressure differential: Maximum operating pressure 1 : ±.5% of full-scale in the center third of the measuring range; ±% of full-scale over the entire scale range. ±1% of full-scale.5-15 GPM (.-56 LPM) see graphs Maximum operating temperature: H-series: ºF (ºC) J-series: 6ºF (315ºC) Standard calibration fluids: HIGH TEMPERATURE FLOW RATE MONITORS High-pressure casing, Aluminum Brass #3 Stainless Steel end ports and tapered shaft Seals H-series (º) Viton w/teflon backup Viton w/teflon backup Viton w/teflon backup J-series (6º) Kalrez w/teflon backup Kalrez w/teflon backup Kalrez w/teflon backup Transfer Magnet Teflon coated Alnico Teflon coated Alnico Teflon coated Alnico Floating Orifice Disk Stainless Steel Stainless Steel Stainless Steel All other internal parts Stainless Steel Stainless Steel Stainless Steel MATERIALS OF CONSTRUCTION (NON-WETTED COMPONENTS) Window Tube Pyrex Pyrex Pyrex Window Seals Teflon Teflon Teflon Teflon is a registered trademark of dupont de Nemours & Co. Viton and Kalrez are registered trademarks of Dow DuPont Elastomers. 1 Note: see Temperature/Pressure De-rating chart PERFORMANCE aluminum and brass monitors: 35 PSIG ( Bar) stainless steel monitors: 6 PSIG (1 Bar) Oil monitors: DTE 5 @ 11ºF (3ºC),.873 sg Water monitors: tap water @ 7ºF (1ºC), 1. sg Air monitors: air @ 7ºF (1ºC), 1. sg and 1 PSIG (6.8 Bar) MECHANICAL TEMPERATURE DERATING FOR ALUMINUM & BRASS MONITORS MAXIMUM SYSTEM PRESSURE 35 3 5 15 1 SAFE OPERATING AREA 3 5 6 SYSTEM TEMPERATURE A SIZE CODE DIM SERIES 3 SERIES A 1-7/8-3/8 (8mm) (6mm) B 6-9/16 7-5/3 (167MM) (18mm) PORT NPTF: 1/, 3/8, 1/ NPTF: 3/, 1 SIZES SAE: #6, #8, #1 SAE: #1, #16 BSP: 3/8, 1/ BSP: 3/, 1 B SERIES 5 3-1/ (9mm) 1-1/8 (58mm) NPTF: 1-1/, 1-1/ SAE: # BSP: 1-1/ SERIES 5 3-1/ (9mm) 1-5/8 (3mm) NPTF: SAE: #3 BSP: Note: Consult factory for SAE brass monitor requirements. 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com

FLOW ALARM Data Sheet No. A-699 FLOW RATE ALARMS FOR 1/ INCH PIPE SIZES FIELD ADJUSTABLE ALARM SETTING Only a screwdriver is required to change the flow alarm setting. WEATHER-TIGHT CONSTRUCTION The sealed, corrosion-resistant, enclosure allows installation in environments where liquid-tight seals are required. SIMPLE ON/OFF LOGIC Positive alarm points using 1 A., dry-contact, SPDT switches, reduce the complexity found in standard rotameter OFF/ON/OFF circuits. PRE-WIRED WITH CABLE DISCONNECT The standard Hirschmann interconnection provides easy installation and maintenance of the FLOW ALARM and the system it is a part of. UNRESTRICTED MOUNTING Allows the designer to install the monitor in any orientation horizontal, vertical or inverted. ECONOMICAL PROTECTION This monitor rapidly pays for itself as it sounds the alarm on incorrect lubrication or cooling volumes, protecting expensive equipment and reducing downtime. QUALITY ASSURANCE Can be an integral part of a quality control system, yielding consistent system operation. ENGINEERING SPECIFICATION THE IN-LINE FLOW RATE MONITOR/ALARM SHALL: have field adjustable, dry-contact, alarm setting(s). use the variable annular orifice technique with compression spring recovery. not require inlet or outlet straight plumbing, or require vertical pipe mounting. have a measuring accuracy of ±.5% of full scale in the center third of the measuring range, and ±% of full scale accuracy over the entire flow measuring range. have a stainless steel sharp-edged orifice. have a weather-tight external construction. be Lake Monitors No. M _ for single alarm applications, or N _ for dual alarm applications.

PRESSURE DIFFERENTIAL VS FLOW RATE 3 5 SERIES 5 MONITORS (1-1/ - ) 15-88 1-75 5-5 -5 6 8 1 1 1 16-99 SERIES MONITORS (3/ - 1 ) FLOW RATE ALARMS MATERIALS OF CONSTRUCTION (WETTED COMPONENTS) High-pressure casing, Aluminum Brass #3 Stainless Steel end ports and tapered shaft Seals Buna-N (STD), EPR, Buna-N (STD), EPR, Viton with Teflon backup Viton or Kalrez Viton or Kalrez (STD), Buna-N, EPR or Kalrez Transfer Magnet Teflon coated Alnico Teflon coated Alnico Teflon coated Alnico Floating Orifice Disk Stainless Steel Stainless Steel Stainless Steel All other internal parts Stainless Steel Stainless Steel Stainless Steel MATERIALS OF CONSTRUCTION (NON-WETTED COMPONENTS) Enclosure Series 3: Series 3: Series 3: polycarbonate polycarbonate polycarbonate Series : polyester Series : polyester Series : polyester Series 5: polycarbonate Series 5: polycarbonate Series 5: polycarbonate and aluminum and aluminum and aluminum Window Seals Buna-N Buna-N Buna-N Teflon is a registered trademark of dupont de Nemours & Co. Viton and Kalrez are registered trademarks of Dow DuPont Elastomers. PERFORMANCE 16 1 1 1 8 6-5 - -3-15 -5 1 3 - -1 SERIES 3 MONITORS (1/ - 1/ ) Measuring accuracy: Repeatability: Flow measuring range: Maximum operating pressure: ±.5% of full-scale in the center third of the measuring range; ±% of full-scale over the entire scale range ±1% of full-scale.5-15 GPM (.-56 LPM); -1 SCFM (1-7 LPS) aluminum and brass monitors: 35 PSIG ( Bar) stainless steel monitors: 6 PSIG (1 Bar) Maximum operating temperature: media: ºF (116ºC) ambient: 18ºF (8ºC) Pressure differential: Liquid: see graphs. Gases: see Pneumatic data sheet Standard calibration media: Oil monitors: DTE 5 @ 11ºF (3ºC),.873 sg Water monitors: tap water @ 7ºF (1ºC), 1. sg Air monitors: air @ 7ºF (1ºC), 1. sg and 1 PSIG (6.8 Bar) Alarm switch dead-band: % of full scale Alarm switch contacts: SPDT (dry contact), UL/CSA rating: 1 amps and 1/ hp, 15 or 5 vac. 1/ amp, 15 vdc; 1/ amp, 5 vdc; 3 amps, 15 vac L (lamp load) Double-Break Switch: Consult factory 1 1 1 8 6-15 -1-5 - -1 6 8 1 1 1 16 MECHANICAL 1.13 A 5.35 3.5 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com DIM SERIES 3 SERIES SERIES 5 SERIES 5 A 6-9/16 (167mm) 7-5/3 (18mm) 1-1/8 (58mm) 1-5/8 (3mm) B 3-11/3 (85mm) 3-9/16 (9mm) 3-1/ (9mm) 3-1/ (9mm) C 3-5/3 (8mm) 3-9/16 (9mm) D 1-7/8 (7mm) 1-7/8 (7mm) PORT NPTF: 1/, 3/8, 1/ NPTF: 3/, 1 NPTF: 1-1/, 1-1/ NPTF: SIZES SAE: #6, #8, #1 SAE: #1, #16 SAE: # SAE: #3 BSP: 3/8, 1/ BSP: 3/, 1 BSP: 1-1/ BSP: Note: Consult factory for SAE brass monitor requirements.

PHOSPHATE ESTER Data Sheet No. P-699 PHOSPHATE ESTER FLOW RATE MONITORS THREE MATERIALS AVAILABLE Select from aluminum, brass or stainless steel construction to meet system requirements. UNRESTRICTED MOUNTING Allows the designer to install the monitor in any orientation horizontal, vertical or inverted. MULTI-USE Factory calibrated for phosphate ester, these versatile monitors can be used to verify hydraulic power unit outputs and to test machinery and tools for proper fluid flow rates. RUGGED AND RELIABLE These monitors are constructed with all metal pressure vessels that allow safe, permanent, installation in industrial systems. FOR 1/ INCH PIPE SIZES HIGH PRESSURE OPERATION The magnetically coupled follower design allows operation to 6 PSIG. TWENTY-THREE DIFFERENT PORTS AVAILABLE Standard selection of NPT, SAE and BSP ports reduces the amount of adapters required for installation. LOW COST PRECISION Mid-scale measuring accuracy within ±.5%. Full-scale accuracy within ±%. ENGINEERING SPECIFICATION THE PHOSPHATE ESTER IN-LINE FLOW RATE MONITOR SHALL: be factory calibrated for phosphate ester measurements. use the variable annular orifice technique with compression spring recovery. not require inlet or outlet straight plumbing, or require vertical pipe mounting. have a measuring accuracy of ±.5% of full scale in the center third of the measuring range, and ±% of full scale accuracy over the entire flow measuring range. have a stainless steel sharp-edged orifice. be Lake Monitors No. P _.

PHOSPHATE ESTER FLOW RATE MONITORS PRESSURE DIFFERENTIAL VS FLOW RATE 3 5 SERIES 5 MONITORS (1-1/ - ) 15-88 1-75 5-5 -5 6 8 1 1 1 16-99 MATERIALS OF CONSTRUCTION (WETTED COMPONENTS) High-pressure casing, Aluminum Brass #3 Stainless Steel end ports and tapered shaft Seals EPR w/teflon backup EPR w/teflon backup EPR w/teflon backup (STD), Viton or Kalrez (STD), Viton or Kalrez (STD), Viton or Kalrez Transfer Magnet Teflon coated Alnico Teflon coated Alnico Teflon coated Alnico Floating Orifice Disk Stainless Steel Stainless Steel Stainless Steel All other internal parts Stainless Steel Stainless Steel Stainless Steel MATERIALS OF CONSTRUCTION (NON-WETTED COMPONENTS) Window Tube Pyrex Pyrex Pyrex Window Seals Teflon Teflon Teflon Teflon is a registered trademark of dupont de Nemours & Co. Viton and Kalrez are registered trademarks of Dow DuPont Elastomers. SERIES MONITORS (3/ - 1 ) 16 1 1 1 8 6-5 - -3-15 -5 1 3 - -1 Measuring accuracy: Repeatability: Flow measuring range 1 : Pressure differential: Maximum operating pressure: PERFORMANCE ±.5% of full-scale in the center third of the measuring range; ±% of full-scale over the entire scale range. ±1% of full-scale.1-13 GPM (.-9 LPM) see graphs at left aluminum and brass monitors: 35 PSIG ( Bar) stainless steel monitors: 6 PSIG (1 Bar) Maximum operating temperature: ºF (116ºC) Note: for operation to 6ºF (316ºC) alternate o-ring material will be required. Standard calibration fluids: DTE 5 @ 11ºF (3ºC),.873 sg. Monitors are density corrected to 1.16 sg. 1 To determine approximate measuring ranges multiply the range listed in the Liquid Flow Rate section of Lake s Guide to standard monitor numbers by.93. For example, a P3A6WB1 would have a scale range to 1 GPM *.93 = 9.3 GPM at full scale. SERIES 3 MONITORS (1/ - 1/ ) MECHANICAL 1 1 1 8 6-15 -1-5 - -1 6 8 1 1 1 16 A SIZE CODE B DIM SERIES 3 SERIES SERIES 5 SERIES 5 A 1-7/8-3/8 (8mm) (6mm) 3-1/ (9mm) 3-1/ (9mm) B 6-9/16 7-5/3 (167MM) (18mm) 1-1/8 (58mm) 1-5/8 (3mm) 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com PORT NPTF: 1/, 3/8, 1/ NPTF: 3/, 1 SIZES SAE: #6, #8, #1 SAE: #1, #16 BSP: 3/8, 1/ BSP: 3/, 1 Note: Consult factory for SAE brass monitor requirements. NPTF: 1-1/, 1-1/ SAE: # BSP: 1-1/ NPTF: SAE: #3 BSP:

FLOW TRANSMITTER Data Sheet No. T-699 FLOW RATE TRANSMITTERS SIMPLE TO INSTALL All transmitters are factory calibrated and ship fully assembled. Simply install the transmitter into your system and apply power. FOR 1/ INCH PIPE SIZES INDUSTRY STANDARD OUTPUTS Transmitters provide proportional analog outputs of -ma, -5 Vdc and 1-5 Vdc 1. These outputs will drive popular data acquisition devices, meters and analog input cards. DIRECT READING OR OPTIONAL DIGITAL DISPLAY All transmitters provide a visual indication of flow rate integral to the transmitted output. For improved readability, an integral digital display is available. WEATHER-TIGHT CONSTRUCTION The sealed, corrosion-resistant, enclosure allows installation in environments where liquid-tight seals are required. RUGGED AND RELIABLE Without delicate internal components to break, abrade or corrode, the Lake flow transmitter will provide many years of low maintenance service. COMPATIBLE WITH LAKE MONITOR S R/T1 AND R1 This Lake flow rate transmitter combines with these Lake analyzers to make a powerful flow instrument capable of remote monitoring of rate and total flows. ENGINEERING SPECIFICATION THE IN-LINE FLOW RATE MONITOR/TRANSMITTER SHALL: be factory calibrated for -ma, -5Vdc and 1-5Vdc outputs. use the variable annular orifice technique with compression spring recovery. not require inlet or outlet straight plumbing, or require vertical pipe mounting. have a measuring accuracy of ±.5% of full scale in the center third of the measuring range, and ±% of full scale accuracy over the entire flow measuring range. have a stainless steel sharp-edged orifice. have a weather-tight external construction. be Lake Monitors No. R _. 1 The 1-5Vdc output requires an external 5 ohm resistor to be wired at the receiving device.

PRESSURE DIFFERENTIAL VS FLOW RATE 3 5 SERIES 5 MONITORS (1-1/ - ) 15-88 1-75 5-5 -5 6 8 1 1 1 16 1 1 1 16 1 1 1 1 3 8 6 8 6-5 - -3-15 -5-15 -1-5 - -1 6 8 1 1 1 16-99 SERIES MONITORS (3/ - 1 ) - -1 SERIES 3 MONITORS (1/ - 1/ ) MATERIALS OF CONSTRUCTION (WETTED COMPONENTS) High-pressure casing, Aluminum Brass #3 Stainless Steel end ports and tapered shaft Seals Buna-N (STD), EPR, Buna-N (STD), EPR, Viton with Teflon backup Viton or Kalrez Viton or Kalrez (STD), Buna-N, EPR or Kalrez Transfer Magnet Teflon coated Alnico Teflon coated Alnico Teflon coated Alnico Floating Orifice Disk Stainless Steel Stainless Steel Stainless Steel All other internal parts Stainless Steel Stainless Steel Stainless Steel MATERIALS OF CONSTRUCTION (NON-WETTED COMPONENTS) Enclosure Series 3: Series 3: Series 3: polycarbonate polycarbonate polycarbonate Series : polyester Series : polyester Series : polyester Series 5: polycarbonate Series 5: polycarbonate Series 5: polycarbonate and aluminum and aluminum and aluminum Window Seals Buna-N Buna-N Buna-N Teflon is a registered trademark of dupont de Nemours & Co. Viton and Kalrez are registered trademarks of Dow DuPont Elastomers. MONITOR PERFORMANCE Measuring accuracy: ±.5% of full-scale in the center third of the measuring range; ±% of full-scale over the entire scale range Repeatability: ±1% of full-scale Flow measuring range:.5-15 GPM (.-56 LPM); -1 SCFM (1-7 LPS) Maximum operating pressure: aluminum and brass monitors: 35 PSIG ( Bar) stainless steel monitors: 6 PSIG (1 Bar) Maximum operating temperature: media: ºF (116ºC) ambient: 18ºF (8ºC) Pressure differential: Liquid: see graphs. Gases: see Pneumatic data sheet Standard calibration media: Oil monitors: DTE 5 @ 11ºF (3ºC),.873 sg Water monitors: tap water @ 7ºF (1ºC), 1. sg Air monitors: air @ 7ºF (1ºC), 1. sg and 1 PSIG (6.8 Bar) Power requirements: Load driving capacity: Transmission distance: Digital Display: LED Indicator: Over-current protection: Resolution: Isolation: Response time: FLOW RATE TRANSMITTERS ELECTRONIC TRANSMITTER PERFORMANCE 1-35 Vdc, connections via screw terminal -ma: Load resistance is dependent on power supply voltage. Use the following equation to calculate maximum load resistance: Max Loop Load (ohms) = 5(Power supply volts - 1). -5Vdc: Minimum load resistance 1 ohms -1mA: Maximum load resistance 1 ohms 1-5Vdc: Minimum load resistance 5K ohms -ma, -1mA and 1-5Vdc: limited only by wire resistance and power supply voltage. -5Vdc: < feet recommended 3.5 digits,.5 digit height, LCD provides power indication, intensity increases with flow rate self limiting at 35mA infinite Inherently isolated from the process <.1 seconds MECHANICAL 1.13 A 5.35 3.5 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com DIM SERIES 3 SERIES A 6-9/16 (167mm) 7-5/3 (18mm) B 3-11/3 (85mm) 3-9/16 (9mm) C 3-5/3 (8mm) 3-9/16 (9mm) D 1-7/8 (7mm) 1-7/8 (7mm) PORT NPTF: 1/, 3/8, 1/ NPTF: 3/, 1 SIZES SAE: #6, #8, #1 SAE: #1, #16 BSP: 3/8, 1/ BSP: 3/, 1 Note: Consult factory for SAE brass monitor requirements. SERIES 5 1-1/8 (58mm) 3-1/ (9mm) NPTF: 1-1/, 1-1/ SAE: # BSP: 1-1/ SERIES 5 1-5/8 (3mm) 3-1/ (9mm) NPTF: SAE: #3 BSP:

R1 AND R/T1 Data Sheet No. RT-699 R1 AND R/T1 FLOW ANALYZERS FLEXIBLE Integrates with Lake Monitor s flow rate transmitters to form a powerful flow control and measurement system. SIMPLE TO USE Every unit ships with easy to use, step by step instructions regarding programming and system setup. EASY TO READ Features 6 digits of bright red 7-segment LED displays that are.55 inches high. TWO PROGRAMMABLE RELAYS The standard 1 Amp form C relays allow precise flow rate and batch control. DUAL POWER OPERATION Units are designed to operate on 11 VAC or 15- VDC. USER SELECTABLE ANALOG INPUT The R1 and R/T1 permit standard analog inputs of -5V, -1V, 1-5V, -ma and -ma. RATE FUNCTION: R1 AND R/T1 Displays.5 digits of user scalable flow rate information. ENGINEERING SPECIFICATION THE DIGITAL TOTALIZER/RATE METER SHALL: interface directly with Lake Monitor s flow rate transmitters. provide.5 digits of rate information and 6 digits of totalized information. have two programmable 1A relays. have user scalable units of measure. have a NEMA /IP 65 front panel. have EEPROM memory backup. have a 1/8 DIN panel cutout. be Lake Monitors Number R1 for rate only measurements or R/T1 for rate and totalized measurements. TOTALIZER FUNCTION: R/T1 Accumulates up to 6 digits of information. A totalizer divider allows total division by 1, 1, 1 or 1.

R1 AND R/T1 FLOW ANALYZERS MECHANICAL PERFORMANCE Enclosure size: 1/8 DIN, 3.63 x 1.78 cutout Construction: high impact ABS Temperatures: Operating +1ºF (5ºC) to +13ºF (5ºC) Storage -ºF (-ºC) to +ºF (93ºC) Humidity: -9% non-condensing Weight: lbs. Connections: via terminal blocks ELECTRONIC PERFORMANCE Measuring accuracy: Temperature stability: Input power: Display: Analog inputs: Input impedence: Resolution: Input protection: Relays: ±.5% maximum measuring error. < ppm over operating range 11VAC ±15% (8VA) or 15-VDC (3mA) 6 digit red LED,,.55 high digits -ma, -ma, -5VDC, 1-5VDC or -1VDC Selectable from the front panel. current inputs: 1 Ohms voltage inputs: 115K Ohms 1.5 bits over voltage: 5V over current: 5mA two SPDT, 1A @1/VAC or 3VDC. DIMENSIONS 3.95 (99.7).37 (11.7).587.5 (17.8) 3.6 (9).65 (66.68) BEZEL GASKET CUSTOMER PANEL PANEL THICKNESS.6" (1.5) TO.187" (.7) MAX. 1.77 (5) APPLICATION RESET IN 1 SIGNAL GND (-DC) 3 (CURRENT) +IN (VOLTAGE) +V IN 5 NOT USED 6 + OUT 7 PRESET B COLLECTOR 8 PRESET A COLLECTOR 9 +DC IN 1 11/ VAC 11 11/ VAC 1 I V GND ANALOG +V 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com RELAY A RELAY B COMMON 13 N.C. 1 N.O. 15 COMMON 16 N.C. 17 N.O. 18 ALARM-A ALARM-B

HYDRAULIC ANALYZER Data Sheet No. HSA-699 HYDRAULIC SYSTEM ANALYZER FOR 1/ 1-1/ INCH PIPE SIZES A COMPLETE TROUBLESHOOTING SYSTEM The analyzer consists of a flowmeter, silicone filled pressure gauge, bi-metal temperature gauge and a precision needle load valve. A comprehensive operator's manual describes testing of various system components. PLAN COMPONENT REPAIRS This system analyzer can be part of a predictive maintenance program, allowing strategized pump, valve, motor and cylinder rebuilding. COMPACT AND RUGGED The complete hydraulic system analyzer is small enough to fit in a tool box and built to withstand tough industrial use. NON-ELECTRICAL Without batteries to fail or other electrical power connections to make, this system will provide a lifetime of simple and reliable operation. METRIC AND SAE MEASURING RANGES These multi-measurement analyzers simultaneously measure flow in GPM and LPM, pressure in PSIG and Bar, and temperature in degrees F and C. UNRESTRICTED MOUNTING Accurate measurements can be taken in any mounting orientation, without the straight pipe required with other analyzer systems. PIN-POINT SYSTEM PROBLEMS The hydraulic system analyzer and comprehensive troubleshooting manual will save time and money by testing discrete components within the system, eliminating trial and error approaches. Test hydraulic pump horsepower developed ANALYZER APPLICATIONS Verify relief valve settings Test cylinder leakage rates Measure directional control valve leakage

3 1-1 - 6 7 8 9 1 11 1 HYDRAULIC SYSTEM ANALYZER MATERIALS OF CONSTRUCTION WETTED COMPONENTS COMPONENT High-pressure casing, end ports and tapered shaft Seals Transfer Magnet Floating Orifice Disk All other internal parts MATERIALS Aluminum and steel Buna-N (STD) Teflon coated Alnico Stainless Steel Stainless Steel NON-WETTED COMPONENTS COMPONENT Windows Window Seals MATERIALS polycarbonate and glass Buna-N PERFORMANCE Measuring Accuracy: Repeatability: Measuring range: Maximum operating pressure: Maximum operating temperature: Standard calibration fluids: flow; ±% of full-scale (±.5% in center third of measuring range) pressure; ±% of full-scale temperature; ±1% of full-scale ±1% of full-scale all measurements Flow:.5-15 GPM (.-56 LPM) see our Guide to Standard Monitors for specific ranges Pressure: -3 PSIG (- Bar) Temperature: -5ºF (--1ºC) aluminum monitors: 3 PSIG ( Bar) ºF (116ºC) Oil monitors: DTE 5 @ 11ºF (3ºC),.873 sg MECHANICAL 1 15 5 1 15 5 C 1 1 1 16 3 5 6 8 5 18 8 1 1-1 - 3 1 5. C. F 1 16 6 7 8 9 1 11 1 5 18 3 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com 5. C. F 5 A SIZE CODE DIM SERIES 3 SERIES SERIES SERIES 5 1 NPTF 3 NPTF 1 NPTF 1 1 NPTF A 1 1 11 1 13 16 1 (66mm) (9mm) (33mm) (mm) B 1 5 1 (1mm) (1mm) (18mm) (133mm) C 5 1 6 1 6 1 8 (1mm) (165mm) 165mm) (mm) PORT NPTF: 1 NPTF: 3 / NPTF: 1 NPTF: 1 1 SIZES B

FLOWSTAT Data Sheet No. FS- CHOICE OF THREE PORT SIZES Select from 1/", 3/" or 1" porting to meet system requirements. EASY MAINTENANCE AND CLEANING Has only one moving component, the impeller. Cleaning and maintenance may be performed without removing the sensor from the piping. HERMETICALLY ENCAPSULATED CIRCUITRY Stands up to the harshest environments. TRANSMIT SEVERAL THOUSAND FEET The standard interface is a -wire, -ma current loop. Sensor signal may be transmitted on a low cost wire without degradation. CONNECTS DIRECTLY TO YOUR FLOW MONITORING INSTRUMENTS Can be connected directly to analog acquisition cards, chart recorders, or other monitoring instruments, without external signal conditioning. SIMPLY PLUMB AND APPLY POWER Comes factory calibrated to your flow range specifications. VALUE PRICING Combined with low cost operation and maintenance, equals better bottom line savings for your operation ENGINEERING SPECIFICATION THE FLOWSTAT SENSOR SHALL: have only one moving component. be calibrated to user specified flow range. have a measuring accuracy of % of full scale. have hermetically encapsulated circuitry. be Lake Monitors Number C - - for the Current output, and No. P - - for the pulse Output version

PRESSURE DIFFERENTIAL VS FLOW RATE φ1/ NPT Port Size WETTED COMPONENTS: Casing Cover MATERIALS OF CONSTRUCTION Seal Turbine Bearing iglide 5 Shaft Stainless steel Stainless Steel Stainless Steel (optional clear polycarbonate) Buna-N (other options available) Acetal copolymer NON-WETTED COMPONENTS: Encapsulant Epoxy Strain relief Nylon Lock Ring Stainless steel Wire insulation High temperature PVC Note: iglide 5 is a registered trademark of igus PERFORMANCE Measuring accuracy: ±% of full-scale Repeatability: ±.5% of full-scale Flow Measuring Range: 1/" porting.5-15 GPM [-6 LPM] 3/" - 1" porting 15-5 GPM [6- LPM] Temperature range: -5º F [ 7 to 17ºC] Pressure Range: to 5 PSIG [3 bar] w/optional clear cover to PSIG [1 bar] Pressure Differential: See graphs φ3/ NPT Port Size φ1 NPT Port Size ELECTRONIC SPECIFICATIONS - MA CIRCUIT: Power Requirements 1-35 Vdc Load driving capacity: 115 Ohms max Maximum transmitting distance: Limited only by wire resistance & supply voltage Response time: seconds to 9% (step change in flow rate) Connections: Via 1 ft. (3m.) awg pigtail Controls: ma (offset): ma (span) factory set Resolution: Infinite Over-current limit: Self limiting at 3mA Other protection: Reverse polarity Fail-safe indication: ma PULSE OUTPUT VERSION: Type: 3 wire, hall effect Voltage: 5V minimum / V maximum Maximum current: 5mADC MECHANICAL DIM 1/ NPTF 3/ NPTF - 1 NPTF 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com A 1.9 (9 mm) 3.6 (78 mm) B 1.13 (9 mm) 1.33 (3 mm) C. (51 mm).6 (6 mm) D.5 (6 mm).78 (71 mm) D*.6 (66 mm).88 (73 mm) E 3.7 (9 mm) 5.5 (133 mm) F.63 (67 mm) 3.8 (97 mm) * Dimension with optional clear polycarbonate cover installed

VISI RATE Data Sheet No. VR- CHOICE OF TWO MATERIALS OF CONSTRUCTION Select from brass or stainless steel to meet system and liquid requirements. UNRESTRICTED MOUNTING Allows the designer to install the monitor in any direction horizontal, vertical or inverted. Two scale positions available for scale reading ease. COMPACT AND RUGGED DESIGN Measures less than 5" long and 1 1 /" diameter with a tough polysulphone body of construction. VISUAL INSPECTION OF FLUID The transparent body allows for visual inspection of fluid conditions. Diagnose problems at a glance. PATENTED SENSING METHOD ASSURES ACCURACY The Helical-Torque sensing method assures accuracy of better than 95% of actual flow rates, even with variable fluid parameters. SUPERIOR READABILITY Extra long 3 1 /" scale, provides excellent flow rate measuring resolution along with dual units of GPM and LPM. FOURTEEN PORT SIZES AVAILABLE Standard selection of NPT, SAE and BSP ports reduces the amount of adapters required for installation. LOW COST PRECISION Measuring accuracy of ±5% and repeatability of ±1%. ENGINEERING SPECIFICATION THE VISI-RATE METER SHALL: use the mass axial turbine rotation to measure flow rate. not require inlet or outlet straight plumbing, or require vertical pipe mounting. have a measuring accuracy of ±5% of full scale with ±1% repeatability. use the helical-torque sensing method to measure flow. be Lake Monitor No VRB - - for flow measuring or for a flow indicator be a VRI -

PRESSURE DIFFERENTIAL VS FLOW RATE MATERIALS OF CONSTRUCTION (WETTED COMPONENTS) BRASS STAINLESS STEEL End Ports Brass Stainless Steel Seals Buna-N Viton Spring (VRB Series) Stainless Steel Stainless Steel Turbine and Casing Polysulphone Polysulphone Measuring Accuracy: Repeatability: Flow Measuring Range: (VRB flow meters) Minimum flow detection: (VRI flow meters) Maximum operating temerpature Maximum operating pressure: Pressure Differential: Filtration requirements: PERFORMANCE ±5% of full-scale ±1 % of full-scale 1-3 GPM [5-11 LPM]. GPM [.8 LPM] 5ºF [11ºC] PSIG [1 bar] See graphs 37 Micron ( U.S. mesh) minimum MECHANICAL DIM 1/ - 1/ SIZES 3/ - 1 SIZES A 1-3/ (5 mm) 1-3/ (5 mm) B 3/ (87 mm) 5-3/8 (137 mm) 388 West Mitchell St. Milwaukee, WI 5315 Phone: 1/671-3577 FAX: 1/671-LAKE (553) Toll Free: 8-85-611 (U.S. & Canada only) www.lakemonitors.com Port NPTF: 1/, 3/8, 1/ NPTF: 3/, 1 Sizes SAE: #6, #8, #1 SAE: #1, #16 BSPP: 3/8, 1/ BSPP: 3/, 1