SKORPION Trapped Key Interlocking with Key Exchange THE SKORPION RANGE - AVAILABLE IN STAINLESS STEEL 316 OR DIE CAST:

Similar documents
SKORPION Trapped Key Interlocking with Key Exchange THE SKORPION RANGE - AVAILABLE IN STAINLESS STEEL 316 OR DIE CAST:

IP69K Stainless Steel Safety Interlock Switches

Providing Machine Safety for YOU at Work. Designed and Manufactured in the United Kingdom

Door Locks Overview of new products now available in the mgard range

Position Switches Series 8070/2

Position Switches Series 8060/2

Position Switches Series 8074/2

D o o r I n t e r l o c k s

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing

F3S-TGR-KHL1/-KHL3/-KHL3R

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Sensor boxes SRBE Key features and product range overview

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

Valve Position Monitors

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Terminal Boxes in Stainless Steel SLS**.T

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Metal Position Switch Series 8074

IDEM Solenoid Interlock Safety Switches

explosive environments Lighting

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

EStrong-series Emergency Stop

CEN/TC 198. EN :2005/FprA1:2010. Date: CEN/TC 198. Secretariat: DIN

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

INTERNATIONAL METAL ENGINEERING

Explosion and flame-proof single phase electric motors

Hi-Cyclic Magna-Cycle Valves

DMR & DMSR. Product Data Sheet. Modular Door Lock with Rotary Switch. Description

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Leading the way in hazardous areas Features EATON

Explosion and flame-proof cast iron electric motors

M-0. M-0... series control, monitoring and signalling devices. Ex e

Safety Interlock Switch with Guard Door Locking. Narrow profile enables mounting to 2 in. square tubing or in applications with space restrictions

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

Operating Instructions

c. Electric hoists and low headrooms

XMR & XMSR Modular Key Exchange Units with Rotary Switches

STAINLESS STEEL PANEL MOUNT

EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

proat Head Options & Ordering Information Part Number Item No. Description T6 ITM proat Head

Pneumatic control unit for decentralized automation of ELEMENT process valves

Motors and drives for applications in explosive atmospheres

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Protecting People, Industry and Productivity

NHP SAFETY REFERENCE GUIDE

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Mechanical features. Spring-loaded elastic terminals: resist vibrations

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

EX-D ENCLOSURES AND DISTRIBUTIONS

K: bracket type. L: pole type

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

INSTRUCTION MANUAL (ATEX / IECEx)

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

INSTRUCTION MANUAL (ATEX / IECEx)

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Certificate of Compliance

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT

Data Sheet. AmLok.

Type Electronic Limit Switch

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Integrated Control modules

Zone 1 Linear Range - Installation Guide

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

An important type of protective

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Safety interlock switch MKey

Pneumatic valves VUWS/valve manifold VTUS

Quarter turn actuators DFPD

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

Resistance thermometer Without thermowell Model TR10-H

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Electrical actuator for industrial applications

FHL. Ex d. Body in aluminium

Safety. Detection. Control. EOS4 - EOS2. Type 4 - Type 2 Safety Light Curtains. Product catalogue. Issue 1

COMBUSTION AND ENERGY

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

A good connection. International approvals.

Sense7-series Non-contact coded safety switch

BMR & BMSR. Product Data Sheet. Modular Bolt Lock with Rotary Switch

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Spring loaded resistance thermometer

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Actuator (DM-F Shown) DM1-CLIN-F

F3S-TGR-KM15/-KM16/-KH16

Load Cell A special beam load cell has been developed by METTLER TOLEDO to meet hygienic criteria. Self draining and a mirror polish make it unique.

ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK

Unused flameproof threads for cable glands have to be closed with certified plugs.

3/2 and 4/2 directional seat valves with solenoid actuation

ATEX II 2G Ex ib IIC T4 Gb. ATEX II 2D Ex ib IIIC T150 C Db ATEXBEAM

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

AZM 161SK 12/12RKED/TU 024

Explosion protected hydraulic products. Product overview industrial and mobile hydraulics

Pneumatic valves VUWS/valve manifold VTUS

Transcription:

THE SKORPION RANGE - AVAILABLE IN STAINLESS STEEL 316 OR DIE CAST: ISOLATION KEY EXCHANGE INTERLOCKING 254 ISB1 PRODUCT OVERVIEW: The SKORPION Trapped Key System has been developed to provide extremely robust mechanical coded key safeguarding and interlocking for hazardous machinery. The system works on the principle of releasing factory coded mechanical keys in a predetermined sequence to ensure machine power is isolated before any access can be gained to hazardous or dangerous machinery. After the machine control has been isolated (first key turned in the system) the key from the isolator can then be used to release other trapped keys to enable access to the guarded areas. After release of the first key (power isolation) safeguarding can be achieved without the need for electrical wiring, this makes the system ideal for use in harsh environments. When used in conjunction with interlock sensing they can be used to achieve up to PLe/Cat4 to ISO13849-1. APPLICATION: A trapped-key guarding system relies upon the transfer of keys between a power isolation switch (or control switch) and a locking mechanism fixed on a guard. The essential feature of the system is that a removable key is trapped either in the guard lock, or in the power isolation switch. The lock on the guard is arranged so that the key can be released only when the guard has been closed and locked. This allows transfer of the key from the guard to the power isolation switch. Closing the switch traps the key, so that it cannot be removed while the switch is in the ON position. If there is more than one source of power, and therefore more than one circuit breaking element to be actuated, then a key-exchange box is necessary, to which all keys have to be transferred and locked in before the access key, which is of a different coding, can be released for transfer to the guard lock. Where there is more than one guard, the exchange box will accommodate an equivalent number of access keys. Where a number of operations have to be carried out in a pre-determined definite sequence, then the transferable key is locked in and exchanged for a different one at each stage. ADVANTAGES: SS-KE-NS5 shown above Available with up to 10 Keys No reduction of integrity due to the distance between movable guard and control system. High mechanical integrity, robust fixings and holdings suitable for all types of guards. Eliminates the need for electrical wiring to each movable guard. Fully Stainless Steel 316 version is suitable when the movable guard is placed in harsh or hostile environments. Suitable for CIP and SIP cleaning processes and can be high pressure hosed with detergents at high temperatures. Can be used where the movable guard requires to be removed completely. All keys are coded in the factory and it is virtually impossible to override the system. A trapped key system provides a quick yet safe and reliable access to machinery. Use of a trapped key system can also prevent shortcuts and enforce a logical set of procedures that need to be satisfied. Until the isolator key is returned to its original position within the lock, there is no way to enable the machinery to be re-started. SS-TS SS-HS SS-BS

KEY EXCHANGE DIE CAST METAL ORDERING: M-KE-NS4 BOLT INTERLOCKS (not suitable for guard access) DIE CAST METAL ORDERING: M-BS M-BD-11 2 x KEY EXCHANGE - M-KE-NS2 2 Key M-KE-NS3 3 Key M-KE-NS4 4 Key First key TRAPPED All remaining keys can be released non-sequentially. M-KE-NS5 5 Key M-KE-S6 6 Key M-KE-S7 7 Key M-KE-S8 8 Key M-KE-S9 9 Key M-KE-S10 10 Key M-BS BOLT INTERLOCK SINGLE KEY Key trapped - bolt retracted First key TRAPPED All remaining keys are then released sequentially. AVAILABLE WITH UP 10 KEYS (First key trapped - 9 released) BOLT INTERLOCK DUAL KEY M-BD-11 2 keys - 1 key trapped 1 key free - bolt retracted BOLT INTERLOCK DUAL KEY M-BD-20 2 keys trapped - bolt retracted 261

HANDLE INTERLOCKS DIE CAST METAL ORDERING: M-HS HANDLE INTERLOCK SINGLE KEY DIE CAST METAIL (Mirror Finish) M-HS Key trapped - actuator unlocked (spring action handle) M-HS-C Key trapped - actuator unlocked (chain fixed to handle) M-HD-11 M-HD-C-11 M-HS-C M-HD-11 M-HD-C-11 HANDLE INTERLOCK DUAL KEY (spring action handle) (chain fixed to handle) 262

TONGUE INTERLOCKS (Single Key) DIE CAST METAL ORDERING: M-TS M-TS M-TD-11 TONGUE INTERLOCKS (Dual Key) DIE CAST METAL ORDERING: M-TD-11 TONGUE INTERLOCK SINGLE KEY Key trapped - actuator unlocked TONGUE INTERLOCK DUAL KEY ACTUATORS FOR TONGUE INTERLOCK SWITCHES SELECTION CHART: SALES NUMBER ACTUATOR TYPE 140107 A = Standard Actuator Stainless Steel 316 140108 F = Flat Actuator Stainless Steel 316 with Plastic Cover 140110 HF = Heavy Duty Flexible Actuator Stainless Steel 316 and Die Cast 140111 HFH = Heavy Duty Flexible Actuator fully Stainless Steel 316 263

ACTUATORS FOR TONGUE INTERLOCK SWITCHES SELECTION CHART: INTERLOCKING WITH CONTROL ISOLATION DIE CAST METAL ORDERING: M-TS-CB 264 EXPLOSION PROOF INTERLOCKING WITH CONTROL ISOLATION DIE CAST METAL ORDERING: M-TS-CB EX M-TS-CB-22-N M-TS-CB-31-N M-TS-CB-22-M M-TS-CB-31-M M-TSR-CB-22-N M-TSR-CB-31-N M-TSR-CB-22-M M-TSR-CB-31-M Trapped Key with ATEX EExd IIC T6 certified explosion proof contact blocks. The explosion proof contact blocks conform to European harmonized standard EN60079-0 and EN60079-1 and can be used in European Zone 1, 2, 21, 22 environments. (Gas and Dust). Designed for use in oil, petro-chemical, pharmaceutical, food processing and packaging applications where the potential for explosive atmospheres are present. M-TS-CB-22-EX M-TS-CB-11-EX TONGUE INTERLOCK SINGLE KEY WITH CONTACT BLOCK Key Trapped - Actuator Unlocked - NC safety Contacts Open Single Tongue Interlock with 2NC 2NO Contact Block - 1/2" NPT Single Tongue Interlock with 3NC 1NO Contact Block - 1/2" NPT Single Tongue Interlock with 2NC 2NO Contact Block - M20 Single Tongue Interlock with 3NC 1NO Contact Block - M20 TONGUE INTERLOCK SINGLE KEY WITH CONTACT BLOCK Key Free - Actuator Unlocked - NC Safety Contacts Open Single Tongue Interlock with 2NC 2NO Contact Block - 1/2" NPT Single Tongue Interlock with 3NC 1NO Contact Block - 1/2" NPT Single Tongue Interlock with 2NC 2NO Contact Block - M20 Single Tongue Interlock with 3NC 1NO Contact Block - M20 Exd IIC T6 (-20 Ta +60C) KEY TRAPPED Ex tb IIIC T85C (-20 Ta +60C) Db TONGUE INTERLOCK SINGLE KEY WITH EXPLOSION PROOF CONTACT BLOCK DIE CAST (Mirror Finish) Single Tongue Interlock with 2NC 2NO Pre-wired EX Block Single Tongue Interlock with 1NC 1NO Pre-wired EX Block SALES NUMBER ACTUATOR TYPE 140107 A = Standard Actuator Stainless Steel 316 140108 F = Flat Actuator Stainless Steel 316 with Plastic Cover 140110 HF = Heavy Duty Flexible Actuator Stainless Steel 316 and Die Cast 140111 HFH = Heavy Duty Flexible Actuator fully Stainless Steel 316