NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION

Similar documents
Self-Regulating Freeze Protection Heating Cable

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

Heating Cable. Cut to Length in Field. Description

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Introduction to Heat Trace Cable Systems

120/240 Volts 3 Watt Floor Heating Cable System

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Heating Cables. For Industry Tracing

Power Connection Kit installation instructions

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

Pipe Freeze Protection Design/Install Guide

3M Self Regulating Heating Cables

Heat Tracing Products

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath

Power-Limiting Cables

Self-Regulating Cables

SELF-REGULATING CABLES

Self-regulating cables

Heating Cable. Construction

Heating Cable. Construction

TSRT TSRT Tee Splice Kit Installation Instructions

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

In-Line / T-Splice Kit Installation Instructions. Terminator DS-L for use with RSX, TSX, VSX self-regulating heating cables

H900 WinterGard Power Connection Kit with End Seal Installation Instructions

Kompensator External Low Voltage Heating Cable System

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket

C A Heating Cable Gland Kit Installation Instructions

Heating Cable. Description

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

HWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES

PETK Power and End Termination Kit

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction

Self-Regulating Pipe Tracing Heating Cable Specification/Application Guide OPTIONAL JACKET. Performance and Rating Data. Catalog Service TSR31J

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

Installation Instructions

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

CAPABILITIES EXPERT TECHNICAL SUPPORT


Electric Heat Tracing INSTALLATION PROCEDURES

INDUSTRIAL HEAT TRACE

PETK Power and End Termination Kit

ET-PWR-END-KIT Installation Instructions (part #JSR00)

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Heating Cable. Description

C Power Connection Kit

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

Terminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Product Overview. Application

Snow Melting Mats Price Sheet

Battery Cables. Wire & Cable

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Heating Cable. Description

UPC Power Connection Kit

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

FREEZSTOP MICRO SYSTEM

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

SCTK Splice Connection Termination Kit

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Type MMV-WP Medium Voltage Wind Power Cable

Installation & Operating Manual

CABLED TWISTED PAIRS CONDUCTORS

Class H & K Fuse Holders - 250/600 Volt

SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1 for BSX, RSX, VSX SCTK-2 for KSX, HTSX SCTK-3 for HPT, FP

Installation Instructions Mineral Insulated (M.I.)

Industrial Control Transformers

CABLED SINGLE CONDUCTORS

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

DESIGN GUIDE FOR STEAM TRACING APPLICATIONS. THERMON The Heat Tracing Specialists

AV-W. Wind Speed and Wind Speed & Direction Sensors

WarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES

Product Instructions. Mixing Station. Features. Specifications. Materials

Terminal Blocks. Section 12. Control Catalog 12-1

Easier! Faster! Safer!

PVC motor cables unshielded

Terminator DP/FAK-5 and FAK-5L

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

FLEXTRACE. FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration. Applications. Characteristics

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Electric Heating Product Catalog

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

Transcription:

Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Industrial Grade, 16 AWG Buss Wire Standard Braid with Overjacket Circuit Lengths to 460 Feet 3, 5 and 8 Watts per Foot 120, 208-277 Volts Available From Stock Description Warmup NAMSR cable is ideal for keeping metal and plastic s warm in commercial construction, institutional buildings and some industrial freeze protection applications. NAMSR cable is constructed of a self-regulating polymer core that varies its output along its entire length, saving energy and eliminating hot spots along the. Parallel construction makes it easier to install than zone or series types of cable since it can be cut to length at any point on the. It can be single overlapped without overheating the cable. Applications Commercial Construction - Cooling Towers - Chilled Water and Plumbing Pipes - Sump Discharge Pipes - Exposed P-traps Industrial - Water Treatment Facilities - Vessel Freeze Protection - Safety Shower Lines Construction A. Buss Wires Twin 16 AWG copper buss wires provide good current capability. B. Matrix A semiconductive polymer core whose electrical resistance varies with temperature. When process temperature drops, the core s heat output increases; conversely, as process temperature rises, heat output decreases. C. Jacket The flame retardant insulation jacket is a thermoplastic rubber material with excellent water resistance. It resists certain mildly corrosive chemicals. D. Tinned Copper Braid The braid covering the jacket provides an effective ground path and mechanical protection. E. Overjacket The TPR overcoat protects the braid, and provides resistance to water and certain inorganic chemical solutions. Approvals CSA Certified for use in ordinary areas

Heating Cable Selection Guide 1. Determine AppIication Data Pipe Size/Type - Insulation Thickness - Minimum Ambient Temperature - Operating Voltage 2. Select Cable Rating Using the selection chart on the following pages and application data from Step 1, above, select the correct cable rating and number of runs needed. Example: Pipe Size / Type: 6 Metal Insulation: 1 Minimum Ambient Temperature: -10 F Operating Voltage: 120 Volts From the chart for 6 metal, 2 Runs of NAMSR5 (NAMSR5 x 2) are needed. To specify 120 volts, add 120V to the cable model number (NAMSR-5W-120V); to specify 208-277 volts add 240V to the cable model number. All product coatings protect against abrasion or inorganic chemical corrosion. 3. Calculate Heating Cable Quantity The total amount of heating cable is determined by adding the total footage of to be traced and an allowance for the components such as flanges, valves, supports, then multiplying by the total number of runs determined in Step 2 (above). (Total Feet of Traced Pipe + Cable Allowance for Components) x # of Runs = Total Cable Length Component Cable Allowances Component Cable Allowance (Ft.) # of Components Flange Pair 1.5 X Pipe Support 2.0 X Butterfly Valve 2.5 X Ball Valve 2.7 X Globe Valve 4.0 X Gate Valve 5.0 X Example: Pipe: 150 feet Valves: Pipe Supports: 2 Flanges: 2 1 globe valve Total Cable Length = [150 + (1 x 4.0) + (2 x 2.0) + (2 x 1.5)] x 2 Runs = 161 feet x 2 Runs = 322 feet

Heating Cable Selection Guide (cont d) 4. Determine Circuits/Circuit Protection Circuit protection depends on the breaker size being used and the start-up temperature. The Canadian Electrical Code, Part I in Canada and the National Electric Code (NEC 1999) in the USA require the use of ground fault protection breakers for heating cable. The following chart shows the maximum circuit length for a given breaker rating. To determine the number of circuits required for each, divide the total cable (circuit) length found in Step 3 by the maximum circuit length found in the chart. Round up to the next higher number. Number of Circuits = Heater Length Maximum Circuit Length Circuit breaker Cable rating Maximum Circuit Lengths (Ft.) 40 F Start-up 0 F Start-up 20 Amp 30 Amp 40 Amp 20 Amp 30 Amp 40 Amp NAMSR-3W-120V 350 360 N/R 270 360 N/R NAMSR-3W-240V 660 N/R N/R 555 660 N/R NAMSR-5W-120V 230 270 N/R 180 270 N/R NAMSR-5W-240V 450 540 N/R 360 540 N/R NAMSR-8W-120V 180 215 N/R 145 215 N/R NAMSR-8W-240V 330 420 420 265 395 420 N/R = Not Required. Maximum circuit length has been reached in a smaller breaker size. Example: Using 20 Amp circuit breakers, how many circuits are needed for the 322 foot circuit shown in Step 3 in a 40 F start-up environment? From the chart: NAMSR-5W-120V maximum circuit length is 180 feet. Number of circuits = 322 feet 180 feet = 2 Circuits

NAMSR Cable Selection Chart Selections suitable for 120V and 208-277V applications. Design based on straight runs of cable or. Spiralling is not required. Heat loss is based on 40 F maintenance temperature and fiberglass insulation K = 0.25 at 50 F Non-metallic heat losses are based on using NAM-TAPE aluminum tape for improving heat transfer. All our products are designated for a ground path for non-metallic applications. Each cell specifies cable rating and # of runs for both metal and plastic s (unless specified). 0.50 0.5 1.0 1.5 2.0 3.0 0.75 0.5 * 1.0 * 1.5 2.0 3.0 1.00 0.5 * 1.0 1.5 * 2.0 3.0 1.25 0.5 1.0 1.5 * 2.0 3.0 *for plastic s

1.50 0.5 1.0 * 1.5 2.0 3.0 2.00 0.5 1.0 * 1.5 2.0 3.0 2.50 * 0.5 1.0 1.5 2.0 3.0 * 3.00 0.5 1.0 1.5 * 2.0 * 3.0 *for plastic s

3.50 0.5 * * 1.0 1.5 2.0 3.0 * 4.00 0.5 1.0 * 1.5 2.0 * 3.0 5.00 0.5 * 1.0 1.5 2.0 3.0 * 6.00 0.5 * 1.0 1.5 2.0 3.0 *for plastic s * *

8.00 1.0 1.5 2.0 * 3.0 10.00 1.0 * 1.5 2.0 3.0 * 12.00 1.0 * 1.5 2.0 3.0 * 14.00 1.0 1.5 2.0 * 3.0 * * 16.00 1.0 * n/a* 1.5 2.0 3.0 *for plastic s

18.00 1.0 1.5 2.0 * 3.0 n/a* n/a 20.00 1.0 n/a* 1.5 2.0 * n/a n/a 3.0 24.00 1.0 1.5 * n/a n/a n/a 2.0 n/a* 3.0 *for plastic s

Cable ratings Systems (500ft) Output @ 50 F (W/Ft.) Max. Circuit Length (Ft.) Weight (lbs.) 1000 120 Volts 208-277 Volts NAMSR-3W-120V 3 360 64 NAMSR-5W-120V 5 270 64 NAMSR-8W-120V 8 215 64 NAMSR-3W-240V 3 660 64 NAMSR-5W-240V 5 540 64 NAMSR-8W-240V 8 420 64 *See chart on page 4 for maximum circuit lengths by start-up temperature and circuit breaker size. Accessories Warmup has a complete line of accessories specifically designed for use with NAMSR cable. Use only Warmup accessories to ensure the performance of the heat trace system. Code Description MSRP NAM-AT-1 Aluminum Foil Tape for Self-Regulating Cable. Sold in 180 ft. roll. $56.00 NAM-POWER-KIT Power Connection Kit for Self-Regulated Cable. Includes 2 warning labels. $56.00 NAM-SPLICE-KIT Splice/Tee Kit for Self-Regulated Cable. $37.00 NAM-HANGER-KIT Downspout Hanger for Self-Regulating Cable and Roof/Gutter heaters. $19.00 NAM-ROOF-CLIP Roof Clips. Sold 10/pkg. $21.00