BCFS Belt Driven Centrifugal Filtered Supply Fans

Similar documents
HA/HAB Fiberglass Wall Mount Ventilators

Installation. Check, Test & Start Procedure

BCRFS Belt Driven Centrifugal Filtered Supply Fans

Backward Inclined Hinged Restaurant Exhaust Fan

Upblast Propeller Roof Fans

Electronically Commutated Motors

Centrifugal Square Inline Fans

INSTALLATION, OPERATION & MAINTENANCE MANUAL Hooded Propeller & Tubeaxial Roof Fans. Models: LHB, LHD, LHBF, LHDF, THB, THD, THBF, THDF

INSTALLATION, OPERATION & MAINTENANCE MANUAL. Centrifugal Square Inline Fans

Centrifugal Square Inline Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

Axial Roof Ventilators & Tubeaxial Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

Propeller Wall Fans INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

48" and 52" Hyflo Fans Installation and Operators Instruction Manual

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INSTALLATION, OPERATION & MAINTENANCE MANUAL Propeller Wall Fans. Models: TCPE, WPB, WPD

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

FADE Series Wall Axial Fans

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

ADI-125/750 ADI-125/1500 ADI-125/2500

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

HP190SL Series Slimline Radon Fans

48" Vanguard Slant Wall and Cone Belt Drive Fans Installation & Operator s Instruction Manual

2SHE Series Direct-Drive Shutter Fans

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

MIL-24/2600Q MIL-24/3200DQ

TSL and QSL Inline Centrifugal and Mixed Flow Fans

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

8-12 INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS

OWNERS MANUAL JANUARY 2007 ISO

SUPERPLUS WATER FILTRATION SYSTEM

Operating and Installation Instructions

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

ECONOMIZER FAN. Receiving and Inspection

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

MODEL 7400 STRUT SPRING COMPRESSOR

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

DeZURIK 2 20" BOS BUTTERFLY VALVES

MODEL G300 BRAKE BLEEDER

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

Model 7500 OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS. Terrco, Inc.

ered Installation, Operation, and Maintenance Manual Direct Drive sizes 6-15 Nonoverloading B.I. Wheel

ESE Series Cast Iron Sewage Pumps

Centrifugal Filtered Supply Fans

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Installation Power Management Unit Battery Cables and Battery Harness

IM Centrifugal Power Roof & Wall Ventilators. Introduction. Shipment and Receiving. Handling. Storage. Issue Date: 4-97 Rev.

SDBDe, STXDe, ered* Installation, Operation, and Maintenance Manual INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

MODEL CLS Centrifugal Filtered Supply Fans

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

Raydot LLC 24 Actuator (115 VOLT)

Air Curtain. Installation, Operating and Maintenance Instructions

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Model CWD Installation, Operation, and Maintenance Manual

DC to AC Power Inverters

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

HQZ & RBM MODEL LIFT & TRANSFERS

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

DC to AC Power Inverters

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

MODEL 7600 STRUT SPRING COMPRESSOR

Pack-Master Air, Spark Resistant Product Manual

Model C230 Pump Controller

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

User s Manual and Operating Instructions

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

DAP-625S and DAP-875S

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

VANGUARD Series 36" Slant Wall and Cone Direct Drive Fans Installation & Operator s Instruction Manual

ZRF-P 2040 TIMING BELT CONVEYOR

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Owner s Manual & Safety Instructions

II DISTRIBUTION & SUBSTATION TYPE C

VersaHitch Bike Rack

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

StormPro BA Series Sump Pump

Positive Displacement Pump

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

Compressor Clutch Replacement Procedure

Electromagnetic Particle Brakes Model: PRB-H

General Guidelines. Instructions for Part # SC-SWING-AWAY-V2. Safety

Installation Instructions

54" Galvanized Hyflo Fan Installation & Operator s Instruction Manual

Transcription:

BCFS Belt Driven Centrifugal Filtered Supply Fans INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-4300 August 2014 Throughout this manual, there are a number of HAZARD S that must be read and adhered to in order to prevent possible personal injury and/or damage to equipment. Two signal words "" and "CAUTION" are used to indicate the severity of a hazard and are preceded by the safety alert symbol. Used when serious injury or death MAY result from misuse or failure to follow specific instructions. CAUTION Used when minor or moderate injury or product / equipment damage MAY result from misuse or failure to follow specific instructions. NOTICE Indicates information considered important, but not hazard-related. It is the responsibility of all personnel involved in installation, operation and maintenance to fully understand the Warning and Caution procedures by which hazards are to be avoided. Model BCFS 140A through 240A Receiving, Inspection & Unpacking When the equipment is received all items should be carefully checked against the bill of lading to be sure all crates and cartons have been received. Before accepting delivery, carefully inspect each carton or crate for visible shipping damage. If any damage is noticed, the carrier should make the proper notation on the delivery receipt acknowledging the damage. Make notations of all damage on all copies of the bill of lading and have all copies countersigned by the delivering carrier. The carrier should also fill out a Carrier Inspection Report. The factory Traffic Department should then be contacted. File claim for damage with the carrier. Physical damage to the unit after acceptance is not the responsibility of Twin City Fan Companies, Ltd. Unpack each carton or crate and verify that all required parts and proper quantities of each item have been received. Refer to drawings for part descriptions. Report shortages or missing items to your local representative to arrange for replacement parts. Due to availability of carriers and truck space, it is not possible to guarantee that all items will be shipped together. Verification of shipments must be limited to only those items on the bill of lading. The unit nameplate must be checked to make sure the voltage agrees with the power supply available. 2006 2018 Twin City Fan Companies, Ltd.

CAUTION Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution. The installation of this equipment shall be in accordance with the regulations of authorities having jurisdiction and with all applicable codes. This equipment is to be installed by an experienced installation company and fully trained personnel. The mechanical installation of the exhaust ventilator consists of making final connections between the unit, building services, and duct connections. 1. Before setting unit on curb (if damper is to be used), make sure that the damper is installed correctly and that it is operative. See diagram, page 4. Installation 2. Position unit on roof curb so that the wiring can be run through one of the knockouts provided. Wiring to the unit may be run through knockouts provided in the curb cap or the side of the unit. Provide enough slack in the wiring to the unit to allow lifting, and removal for cleaning, and inspection. 3. Connect supply leads to the disconnect switch. 4. Check line voltage with the motor nameplate and the attached instruction cards. 5. Determine if wheel is free to rotate and has not been subject to misalignment in shipping or installation. 6. Apply power and check rotation of wheel with directional label in motor compartment. 7. Lag bolt the unit to the roof curb using a minimum of four bolts, one at each corner. Replace unit top panel and fasten all latches securely. Check, Test and Start Procedure Electric shock hazard. Could cause severe injury or death. Failure to bond the frame of this equipment to the building electrical ground by use of the grounding terminal provided or other acceptable means may result in electrical shock. Disconnect electric power before servicing equipment. Service to be performed only by qualified personnel. Make sure power is turned off and locked in the OFF position. 1. Check to verify that the wheel is free to rotate. 2. Verify that supply voltage on the line side of disconnect agrees with voltage on unit identification plate and is within the utilization voltage range as indicated in Table 1. 3. On three-phase units check and calculate phase unbalance as follows: % Voltage Unbalance = 100 x max. voltage deviation from avg. voltage avg. voltage Example: Determine the percent voltage unbalance given voltages of 220, 216 and 213. How To Use The Formula: a. Avg. Voltage = 220 + 216 + 213 = 649 3 = 216 b. Max. Voltage Deviation From Avg. Voltage = 220 216 = 4 c. % Voltage Unbalance = 100 x (4 216) = 1.8% Voltage unbalance should not exceed 2%. 4. Apply power to unit and check rotation of wheel with the directional arrow on the unit. Especially check three-phase units for rotation. For three-phase, rotation can be changed by interchanging any two of the three line leads. If the unit is checked on temporary wiring, it should be rechecked when permanently installed. Motor burn-out or tripped overload protection devices are usually the result of wrong rotation. Motor overloading is usually the result of incorrect rotation, high voltage, or low voltage. The NEC states that motors used in devices such as filtered roof supply units must be protected by a separate overload device that is responsive to motor current or a thermal protector integral with the motor. Refer to Sections 430-22 of the NEC for additional information. 5. Electrical Input Check: Perform check of fan ampere draw and verify that motor nameplate amps are not exceeded. Take account of the service factor range if motor is nameplated above a 1.0 service factor. 6. Fan RPM Check: Fan RPM should be checked and verified with a tachometer. Refer to Table 2 for maximum fan RPM values. Running fan at an RPM greater than the maximum RPM value in Table 2 will overload the fan motor and lead to premature motor failure. The BCFS centrifugal wheels run in a counterclockwise direction when viewed opposite the air intake. If the wheel is run in the wrong direction, the motor will overload and burn out. 2 Twin City Installation and Maintenance Manual IM-4300

Table 1. Utilization Voltage Ranges SYSTEM VOLTAGE/ UTILIZATION VOLTAGE UNIT NAMEPLATE MIN. MAX. 115/60/1 104 127 208-230/60/1 or 208-230/60/3 187 253 230/60/1 or 230/60/3 207 253 277/60/1 249 305 200/60/3 180 220 380/60/3 342 418 460/60/3 414 506 575/60/3 517 633 110/50/1 99 121 220/50/1 198 242 380-415/50/3 342 456 440/50/3 396 484 Table 2. Maximum Fan RPM BCFS MODEL 140 MOTOR HP MAXIMUM FAN RPM 1/6 1100 1/4 1250 1/3 1380 1/2 1590 3/4 1810 1.0 2000 1/6 730 1/4 840 1/3 930 180 1/2 1060 3/4 1220 1.0 1300 1.5 1530 1/3 580 1/2 660 3/4 760 240 1.0 840 1.5 960 2.0 1060 3.0 1180 5.0 1350 FILTERS: To gain access to filters, unlatch top panel and slide top back approximately 2 inches. Lift filters out from top. Filters may be cleaned with soap and water or replaced. Filters should be cleaned regularly, as dirty filters will cause performance to be reduced. Frequency of cleaning depends upon the local environment and frequency of use of the fan. 1. The motors in these units are equipped with prelubricated ball bearings which are considered to be permanently lubricated. 2. Fan shaft pillow block bearings are equipped with grease gun fittings. These bearings are factory lubricated and, with normal operation, will need no lubrication for 3 to 6 months. 3. For pillow block bearings, use a low pressure grease gun with Shell Gadus S2 V100 2 grease or equivalent. Only a few strokes of the gun are required. Excess grease will be forced out through the bearing pressure relief holes. Use of a high pressure gun, however, is liable to blow the bearing seals. 4. Belt tension is adjusted at the factory. It should be readjusted after a break-in period of 24 hours of actual operation. 5. To adjust belt tension, loosen the hex head screw in the tab of the motor plate. Snug belts by pulling on the motor until the belt is tight. Tension is correct if the belt can be twisted from 1 4 to 1 2 turn with moderate pressure at a point midway between sheaves. Maintenance 6. Belt condition and tension should be checked every 3 to 6 months depending on service. If belt tension is too tight, there is a possibility of overloading the motor as well as causing undue belt wear. If the belt tension is too slack, then the wheel will fall off in RPM, air delivery will decrease and the belts will wear quite rapidly. 7. If the air handled by the unit is dust or grease laden, a regular inspection and cleaning of the backdraft damper and the wheel will ensure smooth, efficient operation. Do not replace motor sheave with one larger in diameter. Do not replace fan sheave with one smaller in diameter. The sheave ratios are set so that the motor will not be overloaded within the range of the adjustable sheave. CHECK: Belt tension is adjusted at the factory, but it should be readjusted after a break-in period of approximately 24 hours of actual operation. Twin City Installation and Maintenance Manual IM-4300 3

Figure 1. Typical Installation Figure 2. Opening Location of Duct Adapter Accessory Apply foam tape to seal duct to unit to prevent leakage Duct (Customer Supplied) Damper* X L Duct Adapter (Align this side with inlet side of curb) W Y Duct Flange By Customer Nailer Strip Roof Curb Position duct adapter as shown and secure to nailer strip with nails in holes provided in duct adapter. *For a standard gravity (spring return) damper, recess the damper a minimum of 2" inside the duct in order to clear the fan outlet. For an optional motorized damper, the damper must be recessed 12" to allow for clearance between the actuator and fan outlet. MODEL DIMENSION (IN.) BCFS W L X Y 140A 8 1 2 19 1 2 2 1 4 7 180A 10 1 2 22 1 2 1 7 8 9 240A 13 11 16 29 1 2 1 3 4 11 1 2 Figure 3. Location of Fan Outlet Top View of Roof Curb Showing Duct Location X Curb Sq. L Fan Outlet W MODEL DIMENSION (IN.) CURB SUPPLY BCFS W L X Y SQ. DAMPER 140A 8 19 2 1 2 7 1 4 30 x 30 8 x 19 180A 10 22 2 1 8 9 1 4 36 x 36 10 x 22 240A 13 3 16 29 2 11 3 4 47 x 47 13 x 29 Y DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. Inlet Side of Fan (Provide a min. of 15" between inlet side and nearest obstruction) 4 Twin City Installation and Maintenance Manual IM-4300

To prevent damage during shipment, the motor of this unit has been installed at the factory, tested, then removed and shipped separately. Please follow the instructions below to reinstall the motor. 1. Fasten the motor plate to the bearing plate by inserting the hinge pin in the holes and then putting a hitch pin in the hole of the hinge pin. See Figure 4. 2. Install the belts on the sheaves, apply tension and tighten the bolt at the top of the motor plate or the nut on the jacking bolt to maintain tension. The ideal belt tension is to be enough so that the belt does not slip under peak load. Do not over-tighten the belt as it will severely reduce the life of the bearings. Motor Installation 3. Check the sheave alignment as shown in Figure 5 below and align sheaves with a straightedge if necessary. Be sure the belt tension is rechecked if the sheave alignment is changed. NOTICE The belt tension will need to be rechecked after the fan has been operating for a few days. There is an initial break-in period for the belts in which they may stretch. Figure 4. Motor Plate Assembly Figure 5. Sheave Alignment HINGE PIN TENSION HOLD BOLT HITCH PIN Twin City Installation and Maintenance Manual IM-4300 5

Seller warrants to the original purchaser that the goods sold hereunder shall be free from defects in workmanship and material under normal use and service (except in those cases where the materials are supplied by the buyer) for a period of one year from the date of original installation or eighteen (18) months from the date of shipment, whichever occurs first. The liability of seller under this warranty is limited to replacing, repairing, or issuing credit (at cost, F.O.B. factory and at seller s discretion) for any part or parts which are returned by buyer during such period provided that: a. seller is notified in writing within ten (10) days following discovery of such defects by buyer, or within ten (10) days after such defects should reasonably have been discovered, whichever is less; b. the defective unit is returned to seller, transportation charges prepaid by buyer. c. payment in full has been received by seller for said products; and d. seller s examination of such unit shall disclose to its satisfaction that such defects have not been caused by misuse, neglect, improper installation, repair, alteration, act of God, or accident. Limitation of Warranties and Claims No warranty made hereunder shall extend to any seller product whose serial number is altered, effaced or removed. Seller makes no warranty, express or implied, with respect to motors, switches, controls, or other components of seller s product, where such components are warranted separately by their respective manufacturers. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHETHER STATUTORY OR OTHERWISE, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no event shall seller be liable to buyer for indirect, incidental collateral, or consequential damages of any kind. (BUYER S FAILURE TO PAY THE FULL AMOUNT DUE WITHIN SIXTY (60) DAYS OF DATE OF INVOICE SHALL OPERATE TO RELEASE SELLER FROM ANY AND ALL LIABILITY OR OBLIGATION ARISING PURSUANT TO ANY WARRANTY, EXPRESS OR IMPLIED, WHETHER STATUTORY OR OTHERWISE, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE IN CONNECTION WITH ANY CONTRACT FORMED HEREUNDER. BUYER AGREES THAT SUCH FAILURE TO PAY SHALL CONSTITUTE A VOLUNTARY WAIVER OF ANY AND ALL SUCH WARRANTIES ARISING PURSUANT TO SUCH CONTACT.) TWIN CITY FAN & BLOWER WWW.TCF.COM 5959 Trenton Lane N Minneapolis, MN 55442 Phone: 763-551-7600 Fax: 763-551-7601