Sanitary RTDs and Temperature Transmitters

Similar documents
Sanitary RTDs and Temperature Transmitters

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

Mini Pressure Transmitter HA7

Instruction Manual HMP TURBINE FLOWMETER. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

Tel: SEMITORR GROUP INC.

Modular Pharma Pressure Transmitter MPP

DIGI-TEL THERMOMETERS

Special Purpose Transmitters

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Continuous level sensor NSK

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Continuous level sensor NSL-F-00, -01, -02

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Model DFX Doppler ultrasonic flow meter

Smart Pressure Transmitter

OEM Pressure Transmitters

Type Type 1001 Transducers. I/P & E/P Transducers

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

Sensors and Accessories

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

FasTrak High Capacity Smart Positioner

Continuous level sensor NSK

Pressure Transmitter JUMO dtrans p30 Type

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Smart Pressure Transmitter

Industrial Pressure Transmitters

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

G2 Industrial Grade Meters

Smart Pressure Transmitter

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Temperature Measurement Solutions. Dial Indicating Electronic Industrial RTDs Thermowells Accessories

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

TEL-TRU MANUFACTURING COMPANY DIGITAL THERMOMETERS

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

SANITARY PRESSURE GAUGES

L E V E L P L U S M - S E R I E S ANALOG

SATRON VTe pressure transmitter

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

PIT, PIF & PIX Pressure-to-Current Transmitters

Masoneilan Series

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

7330 Pro-Stik II Magnetostrictive Level System

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

Smart Pressure Transmitter

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Screw-in resistance thermometers with plug connector

M3500 Industrial Pressure Transmitter

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

JUMO MIDAS S05 Pressure transmitter Type

Industrial Meter Catalog

Level Measurement Point level measurement - RF Capacitance switches

Type A-10 General Purpose Pressure Transmitter

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Resistance thermometer with digital indicator Model TR75, battery operation

Pressure Transmitter

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Type A-10 General Purpose Pressure Transmitters

N I S T traceable calibration equipment conforms to MIL-STD-45662A.

Smart Products. Maxon Workshop Richard Reyes

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

HUMIDITY / TEMPERATURE TRANSMITTER

Micro Motion F-Series Coriolis Flow and Density Meters

DIGITAL REFERENCE THERMOMETER (DART)

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

STEEMCO Flowmeter for Steam

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Product Data Sheet , Rev GA Catalog Content

Ultrasonic Two-Wire Point Level Control

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

DIGITAL REFERENCE THERMOMETER (DART)

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Compact Pressure Transmitter DAN-HH

PIT, PIF & PIX. Features. Pressure-to-Current Transmitters

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

Micro Motion Model D and DL Coriolis Flow and Density Meters

Pressure transmitter JUMO dtrans p02

Pressure Transmitters for Sanitary Applications Model SA-11

AGW Life Sciences Series Guided Wave Radar

Installation and Operation Instructions DLP Series

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

Low Profile Insertion Vortex

Transcription:

Sanitary RTDs and Temperature Transmitters Modular components provide maximum configuration flexibility Unique element-to-housing design eliminates exposed threads, lowers profile All stainless steel construction with O-ring seals for maximum corrosion and moisture protection Custom lengths (up to 6") available at no extra charge Dual Output Options Quick Disconnect Options Anderson Instrument's electronic temperature sensors combine our industry proven, all stainless steel construction with modular components. Interchangeable RTD elements, wiring heads, transmitter modules and digital displays can be individually selected. Components can be factory or field assembled in the optimum configuration for any application. To further facilitate adaptability, our RTD's are offered with the widest selection of sanitary clamp, thermowell and flush-mount fittings; and with sealed cable, quick disconnect, or wiring heads options. Our temperature transmitters are available in analog and HART "SMART" versions. These modules can be factory or field installed in any standard (CT) wiring head or panel mounted remotely from the RTD element allowing for greater flexibility. New Dual Output options provide two signals in virtually any combinations. Ordering information, technical specifications and dimensional drawings are included herein, or for more information please visit our Web Site at www.andinst.com, or contact your local Authorized Anderson Distributor. ANDERSON INSTRUMENT CO., INC 156 AURIESVILLE RD. FULTONVILLE, NY 12072 USA 800-833-0081 FAX 518-922-8997 ANDERSON INSTRUMENT CO. LP 400 BRITANNIA RD. EAST, UNIT 1 MISSISSAUGA, ONTARIO L4Z 1X9 CANADA 905-603-4358 FAX 905-568-1652 NEGELE MESSTECHNIK GmbH Raiffeisenweg 7 D-87743 Egg a. d. Günz GERMANY +49 (0) 8333/9204-0 FAX +49 (0) 8333/9204-49 www.andinst.com

Sanitary RTD's Anderson SA-Series RTD sensors are 100 ohm, 3-wire, DIN standard elements designed for direct immersion in sanitary applications or in any of a wide variety of thermowells. Sensors are available in single or dual element configurations. Single element styles may be specified with factory sealed, shielded cables up to 200 feet in length, or in our unique modular design or with our new water-tight quick disconnect. The modular elements can be mated with either the "mini" head for stand-alone RTD applications or our transmitter head for analog or "SMART" transmitter applications. All dual element sensors are supplied in the modular configuration, now available with dual output wiring heads as well. All sensors feature completely sealed internals for maximum moisture and vibration resistance. They provide the fastest possible response characteristics due to our unique method of internal element attachment which eliminates all air and nonmetallic materials between the element and the process material being monitored. These sensors are constructed entirely of 316L grade stainless steel. All stainless steel with no exposed threads Compact, low in profile Field serviceable - replaceable elements Multiple wiring options Specifications RTD Elements General: 100 ohm, 3-wire* sensors which conform to DIN standards. Single element standard; dual element optional Response: Span: Low End: 2.5 to 3 seconds for 63% step change 400 F (221 C) maximum -50 F (-45 C) minimum Coefficient:.00385 ohms/ohm/deg. C High End: 350 F (176 C) maximum Accuracy:.1% at 0 C (Band 1) Standard Material: 316 "L" Stainless Steel wettable parts Probe Diameters: 1/4" standard for sanitary clamp styles (1"-4") single or dual element. Other diameters available for thermowell installation Surface Finish: Fitting Styles: 25 micro-inch R a 32 micro-inch R a (thermowell fittings) All standard sanitary clamp styles, including fractional clamps and mini thermowell styles; Refer to ordering matrix for details * RTD s with quick disconnect are configured for 4-wire connection to minimize output errors from connection resistance. Wiring Heads General: Material: The wiring heads are designed to accept any type of RTD element, but offers the cleanest package when coupled with Anderson "no exposed thread" RTD's, which provide an O-ring seal against the housing. 304 Stainless Steel Surface Finish: Dimensions: Penetrations: 32 micro-inch R a max. Transmitter: 3.15" O.D. X 2.75" L Mini RTD: 2.0" O.D. X 2.3 L (2) at 1/2" - 14 NPT female; (1) centered in bottom plate; (1) in side beneath cap rim. Cable Connections: Standard NEMA 4X "Hubbell" style cable "grip", or Optional Quick Disconnect with Field Wireable Connector Ratings: NEMA 4X; IP66

Temperature Transmitters Any single element RTD can be used with our 4-20 ma transmitters. Our standard 4-20mA transmitter module can be mounted in our transmitter wiring head or in a remote panel. The module not only provides an accurate signal (0.1% of calibrated span) but is also completely sealed in urethane for protection against vibration and moisture. An optional digital display can be mounted in the cap providing local indication of temperature, signal level, or percent output. This option can be factory installed or added in the field. The housing can be oriented vertically or horizontally to simplify wiring and optimize viewing angle. Any of the above may be specified in single (standard) or dual (any combination) outputs. The result is a competitively priced transmitter which is: Modular - field replaceable/upgradeable components. All stainless steel with no exposed threads Compact, low in profile Specifications Analog Transmitter Module Input: 3-wire, 100 ohm, DIN standard curve (385 coefficient) Output: 2-wire, 4-20 ma analog Power Supply: 12 to 40 Volts d.c. loop power required Accuracy: 0.1% of calibrated span, linearized Minimum Span: 50 F or C Maximum Span: 300 F, 180 C Minimum Low End: 0 F or C Maximum Low End: 100 F or C Minimum High End: 50 F or C Maximum High End: 350 F, 180 C Wiring Connections: Isolation: Burn-Out: Zero Adjustment: Span Adjustment: Screw terminals with #3 screws Non-isolated Upscale (factory standard) downscale (consult factory) "Pot" adjustable to ±25 F (±15 C) typical "Pot" adjustable over a 25 F (15 C) range minimum SMART Transmitter Module Input: 3-wire, 100 ohm, DIN standard (.00385 ohms/ohm/ C) Output: 4-20 ma, linear with temperature; Digital output signal superimposed on 4-20mA signal; "HART" compliant Isolation: Input/Output isolated to 500V rms (707V p-p) Accuracy: ± 0.1% of upper range limit (URL); includes non-linearity, and hysteresis Stability: 0.1 C per 6 months Minimum Span: 10:1 turndown (23 C) Maximum Span: 230 C Maximum Range: -50 to 180 C Power Required: 14-40 VDC external loop power (unregulated) Power Supply Effect: Less than 0.005% of span per Volt Max. Loop Resistance: (Supply Voltage - 14) X 40 = Ohms AGENCY APPROVALS Electromagnetic Compatibility (EMC): CE Compliant (for optional LCD only, display accuracy de-rated up to 2% in 150-180 MHz and 230-350MHz, 10V/M RF Field). Hazardous Locations: Meets UL requirements for Class 1, Div. 1&2; Groups A-D for intrinsically safe apparatus when installed with barrier as required in control drawing provided Ambient Limits: -18 to 50 C Ambient Effects: ±0.13 C per 28 C temperature change Storage Temperature: -40 to 65 C Humidity: 0-100% RH Vibration Effects: Withstands 2g at 10-60 Hz Failure Mode: Field selectable, High or Low Warranty: Two Years Display Module General: The display module provides a local display of temperature ( F or C) or output value (milliamps or percent). It mounts in the cap and is powered by the loop power supply. It is designed to be easily added to any unit in the field or can be specified initially with any unit or transmitter. Digits: 3-1/2 digits Digit Size:.5" High Type: LCD Mounting: Integral to cap; field replaceable/upgradeable Units of Display: 4-20mA; 0-100%; Degrees C; Degrees F (0-199.9 F max) factory set, or 0-300 F. Accuracy: ±0.2% of scale Loop Resistance: Adds less than 250 ohms

Dimensional Drawings Modular Wiring Heads 3.50 MAX. 2.30 3.49 3.15 DIA. 2.00 3.14 1.00 2.70 2.75 3.14 1.95 2.30 4.75 4.27 DUAL CABLE LIQUID-TIGHT CONNECTOR TRANSMITTER HEAD RTD Fitting Styles and Sizes "MINI" RTD HEAD DUAL OUTPUT WIRING HEAD 1-1/2" - 4" TRI-CLAMP STYLE DESCRIPTION "A" DIM. "B" DIM. DESCRIPTION WELL STYLES "A" DIM. 1-1/2" TRI-CLAMP 2-3/4" 1/4" DIA. 2" TRI-CLAMP 3-1/2" 1/4" DIA. 2-1/2" TRI-CLAMP 3-1/2" 1/4" DIA. 3" TRI-CLAMP 3-3/4" 1/4" DIA. 4" TRI-CLAMP 4-1/2" 1/4" DIA. Tapered to fit 41247 WELL 9-1/8" 41279 WELL 12-1/8" SPRING LOADED STYLES DESCRIPTION "A" DIM. "B" DIM. 1/2" NPT 6" 1/4" DIA. 1/2" NPT 9" 1/4" DIA. E-1 & E-3 STYLES DESCRIPTION "A" DIM. "B" DIM. E-1* 12" 1/4 DIA. E-1* 18" 3/8 DIA. E-3 12" 1/4 DIA. E-3 18" 3/8" DIA. * NO UNION "B "A" AIC FLUSH MOUNT DESCRIPTION "A" DIM. LONG 6.50 SHORT 2.19 Special "A" diameter available upon request. Note: A dimensions of less than 1.5" de-rates accuracies by 0.1%/50 C at temperatures exceeding 212 F (100 C)

Dimensional Drawings RTD Styles QDR RTD "A" 1 13/16" 1/4" M12 QDR VARIES W/ FITTING Sealed Cable RTD "A" 4-1/2 MAX. 1/4" VARIES W/ FITTING Ordering Examples 1. Sanitary Series RTD, single element, 50' sealed cable with strain relief, 1.5" Tri-Clamp fitting. Model #: SA110040370110 2. Sanitary Series RTD, dual element, with wiring head, 2" Tri-Clamp fitting. Model #'s: SA520050490000 (RTD) CT320000001100 (wiring head) 3. Analog (4-20mA) temperature transmitter, 0-150 C range, 0-100% display, with pre-wired RTD, with thermowell fitting for 6" insertion, 1/4" diameter, 1/2" NPT. Horizontal mount wiring head. Model #'s: SA510840890000 (RTD) CT13073C022100 (wiring head with transmitter) 4. Smart (4-20mA with HART) temperature transmitter, field programmable range, no display, with pre-wired RTD, with 1.5" Tri-Clamp fitting. Vertical mount wiring head with 25' pre-wired cable. Model #'s: SA510040370000 (RTD) CT14999P001105 (wiring head with transmitter)

Ordering Information RTD's S A WIRING STYLE 1 Sealed Cable w/strain Relief 2 Sealed Cable w/male 1/2 NPT & Strain Relief 5 6 leads for use with wiring head (see CT matrix) 7 Quick Disconnect (see Quick Disconnect Connection/Cable) ELEMENT TYPE 1 100 ohm Single (DIN stnd.) 2 100 ohm Dual (DIN stnd.) (available w/wiring style #5 only) FITTING INSERTION LENGTH 2 004-037 1-1/2 Tri-Clamp 2-3/4 005-049 2 Tri-Clamp 3-1/2 006-049 2-1/2 Tri-Clamp 3-1/2 007-053 3 Tri-Clamp 3-3/4 008-065 4 Tri-Clamp 4-1/2 010-031 1-1/2 APC K 3 2-3/8 011-730 2 APC K 3 2-25/32 016-031 1-1/2 Cherry-Burrell I 2-3/8 017-730 2 Cherry-Burrell I 2-25/32 027-044 1-1/2 G&H H Line (male) 3-3/16 028-056 2 G&H H Line (male) 3-15/16 032-033 1-1/2 Cherry Q 2-1/2 033-049 2 Cherry Q 3-1/2 034-028 1-1/2 #14 APC-PV (w/nut) 3 2-3/16 035-729 2 #14 APC-PV (w/ nut) 3 2-17/32 038-028 1-1/2 #14 APC-PV (w/o nut) 3 2-3/16 039-729 2 #14 APC-PV (w/o nut) 3 2-17/32 044-731 1-1/2 #14 Bevel seat (w/nut) 3 2-15/64 045-035 2 #14 Bevel Seat (w/nut) 3 2-5/8 046-731 1-1/2 #14 Bevel St. (w/o nut) 3 2-15/64 047-035 2 #14 Bevel Seat (w/o nut) 3 2-5/8 051-029 1-1/2 APC K15WXF (female) 3 self aligning 2-1/4 052-036 2 APC K15WXF (female) 3 self aligning 2-11/16 060-221 Umbrella 14-1/4 060-360 Umbrella 22-15/16 060-435 Umbrella 27-5/8 060-532 Umbrella 33-11/16 060-680 Umbrella 42-15/16 061-077 Split Ferrule (button) 5-1/4 062-139 Projectile Well (41247) 5 9-1/8 063-161 Projectile Well (41280) 3, 5 10-1/2 064-187 Projectile Well (41279) 3, 5 12-1/8 074-185 E1 Style - 1/4 Dia. (plain) 5 12 075-185 E1 Style - 3/8 Dia. (plain) 5 12 079-185 E3 Style - 1/4 Dia (with adjustable union) 4, 5 12 080-185 E3 Style - 3/8 Dia. 4, 5 (w/adjustable union) 12 083-137 Bi-Metal Well - 1/4 NPT 5 9 084-089 Bi-Metal Well - 1/2 NPT 5 6 084-137 Bi-Metal Well - 1/2 NPT 5 9 088-000 Anderson Flush Mt. (short) 3 089-000 Anderson Flush Mt. (long) 3 098-000 Taylor Flush Mount 3, 6 100-049 Industrial well(41070) 6 3-1/2 101-091 Industrial well(41074) 6 6-1/8 174-089 Spring Loaded 1/4" Dia. - 1/2" NPT 5 6" 174-137 Spring Loaded 1/4" Dia. - 1/2" NPT 5 9" CONNECTION/CABLE 00 No Cable (wiring style #5) 01 5 (Standard w/wiring style #2) 05 25 (Standard w/wiring style #1) 10 50 15 75 20 100 21 125 22 150 23 175 24 200 A0 A1 A2 A3 A5 QUICK DISCONNECT OPTIONS Quick Disconnect Receptacle(QDR) w/no cable QDR & Field Wireable Connector(FWC) w/ no cable QDR w/25 ft 5-Conductor Molded Cordset QDR w/50 ft 5-Conductor Molded Cordset QDR w/100 ft 5-Conductor Molded Cordset CABLE TYPE 0 No Cable Required (Std. w/wiring style #5, available for wiring style #7) 1 Multiple conductor PVC (Std. w/wiring style #1 or #2, available for wiring style #7) PROBE 0 Standard probe (choose for well fittings) 1 Heavy duty probe 1 (recommended for lengths over 6") 1 Heavy Duty Probes with 3/4 Dia., insertion lengths from 3-1/2 to 43-1/2 available for standard fittings, Tri-Clamp, Cherry I, Bevel Seat and Umbrella Consult factory for other fittings. 2 Custom lengths (up to 6") available at no extra charge, but are non-cancellable/non-returnable for credit. 3 Sensors with these fittings are non-cancellable/nonreturnable for credit. 4 Requires bushing: 29057A0001 1/2 14NPT 29057A0002 3/4 14NPT 5 Meets 3-A when used with a 3-A compliant well 6 Not 3-A compliant ACCESSORIES Anderson Weld-In Shells for Flush Mount Fittings 71060A0003 Insulated Vessel (089 fitting) Standard Flange - 316L 71060A0004 Uninsulated Vessel (088 fitting) Standard Flange - 316L

Ordering Information Modular Wiring Heads for RTD's and Transmitters C T 1 PRODUCT CODE STYLE 1 Standard 2 Standard (with health authority seal provision) 3 Mini (for RTD and analog transmitter) 4 Mini (with health authority seal provision) 7 Standard, Dual Output 8 Standard, Dual Output (with health authority seal provision) MODULE* Single Output Options 0 No Module 1 Single RTD 2 Dual RTD 3 4-20mA Analog transmitter (head style 1 or 2 only) 4 SMART Module with 4-20 ma and HART (head style 1 or 2 only) 5 4-20mA Mini transmitter (head style 3 or 4 only) 6 4-20mA Mini transmitter (head style 3 or 4 only) (for use with probe lengths of 1.25 or less) A B C D E Dual Output Options Dual 4-20mA Temperature Transmitter Dual Smart with 4-20mA with "HART" 4-20mA Temperature Transmitter & RTD Smart 4-20mA with "HART" & RTD 4-20mA Temp. Transmitter & Smart 4-20mA with "HART" Transmitter OUTPUT RANGE 000 None (RTD only) 069 0-60 (C only) 071 0-100 (F or C) 073 0-150 (F or C) 075 0-200 (F only) 076 0-250 (F only) 077 0-300 (F only) 119 30-230 (F only)** 132 50-250 (F only)** 160 100-300 (F only) 255 0-180 (C only) 999 Programmable (Module Style 4, B, and D only) ENGINEERING UNITS 0 None - RTD Only (Module 1 & 2 above) F Fahrenheit C Celsius P Programmable (Module Style 4, B, and D only) DISPLAY/UNITS (Not available w/ Mini styles or RTD modules) 00 None 01 4-20mA 02 0-100% 03 F (same range as output) 04 C (same range as output) CONNECTION / CABLE (Includes water tight cord grip) 00 No cable (Std.) 05 25ft 10 50ft 15 75ft 20 100ft (Quick Disconnect Options)*** A0 QDR only A1 QDR & Field Wireable Connector (FWC) A2 QDR / FWC w/ 25ft A3 QDR / FWC w/ 50ft A4 QDR / FWC w/ 75 ft A5 QDR / FWC w/ 100ft 1 FIXED CHARACTER PRE-WIRED ELEMENT (refer to picture below for orientation) 0 None 1 Vertical Orientation (option A ) 2 Horizontal Orientation (option B ) * To order only the output module, consult our Customer Service Department. SMART Module Part Number: 5610100003 ** This range available with display options 00, 01, 02 only. *** Not available with output range 000. Not available with Dual Output Figure 1 - Probe Orientation B A

Form No. AIC5001 3/99 Revised: March 2013 Supersedes: November 2012