Model 14 Sound Level Meter User Manual Page 1. User Manual for the Model 14 Sound Level Meter

Similar documents
CR:306 Sound Level Meter User Manual Page 1. User Manual for the CR:306 Sound Level Meter

INVICTUS NOISE MONITOR WINDSHIELD TECHNICAL INFORMATION

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

Adam Equipment CPW COMPACT SCALE

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

2 TONNE TROLLEY JACK

TESTER SET SOCKET & VOLTAGE

ETHOS Digital Sound Level Meter. Operating Manual

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

User's Manual. Earth Ground Resistance Tester. Model Introduction

CASTLE GROUP USER MANUAL FOR ACOUSTIC CALIBRATORS: GA601, 607, AND GA609

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

CONTACTS RELAY TESTER 66249

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Electric actuators for small valves

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Issue 2.0 December EPAS Midi User Manual EPAS35

Indoor Air Quality Meter

Rental Industry Safety Tester Safe Check 5s

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

PRODUCT SPECIFICATION. Stack Lights. Series.

3 TONNE TROLLEY JACK

Quickstart Guide to Operating Instructions IVECO Daily: 1-Way Bison Tipper

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

Megohmmeter Test Probe

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

Operating instructions

owner s MANUAL TFX MANUAL_01

APPLICATION GUIDE FOR: CAMSHAFT DRIVE CHAIN WEAR INDICATOR

User s Manual Power Supply IM E. 5th Edition

DIAGNOSTIC TOOL BATTERY

Phase Sequence Tester

CONTACTS EGR VALVE TESTER 66248

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

ILED Dorado. User Manual

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

PolyStat Immersion Circulators

HD18F2M1.

RF DIRECTIONAL THRULINE POWER SENSOR MODEL 5010

This manual covers the following model:

Technical Documentation

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

55 KW / 70 KVA POWERED by

ANALOG SOUND LEVEL METER

P U L S A R point 210

DEEP SEA ELECTRONICS PLC

IAQ-CALC TM Indoor Air Quality Meter

SSP-Series Portable Balances Operation Manual

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

EPAS Desktop Pro Software User Manual

Autoranging Industrial Multimeter

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Time Electronics DC Voltage Calibrator. Technical Manual

PTS SERIES With AE402 Indicator

5-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

Tire Pressure Monitoring System (TPMS) Introduction

DEEP SEA ELECTRONICS PLC

EC200 ELECTRONIC CONTROL SYSTEM

DEEP SEA ELECTRONICS PLC

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

LHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1

1ZSE en, Rev. 4. On-load tap-changers, type UC User s manual

COAXIAL SPEAKERS FI4-F3, FI5-F3, FI57-F3, FI6-F3, FI69-F3

LRX LRX. TemperatureTransmitter. Low-Power. April B. Low-Power. Temperature Transmitter

Melody 1 Platform Lift

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

PNEUTORQUE STANDARD & SMALL DIAMETER SERIES STALL TOOLS

POWERWARE User s Guide VA.

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

EV100. Electric Vehicle Supply Equipment Tester. Operating Instructions

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

ABB component drives ACS150, 0.5 to 5 Hp

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

Declaration of Conformity

Electromotoric Actuators

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

3-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

OPW Fluid Transfer Group Europe BV

Series A Electric Linear Actuators

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

DigiTemp. Digital Thermometer

701S/R. Watson-Marlow manual control high flow pump Installation and operating instructions. Publication PB 0142 Issue 2.

Transcription:

Model 14 Sound Level Meter User Manual Page 1 User Manual for the Model 14 Sound Level Meter This manual, the software to which it relates, the program code and drawings are all: Copyright Pulsar Instruments Plc 1989-2015

Model 14 Sound Level Meter User Manual Page 2 The content of this manual, any illustrations, technical information and descriptions within this document were correct at the time of going to print. Pulsar Instruments Plc reserves the right to make any changes necessary, without notice, in line with the policy of continuing product development and improvement. No part of this publication may be duplicated, reprinted, stored in a data processing system or transmitted by electronic, mechanical, photographic or other means, or recorded, translated, edited, abridged or expanded without the prior written consent of Pulsar Instruments Plc. No liability is accepted for any inaccuracies or omissions in this manual, although due care has been taken to ensure that is it complete and accurate as possible. Accessories supplied by Pulsar Instruments Plc have been designed for use with the instrumentation manufactured by Pulsar Instruments Plc. No responsibility is accepted for damage caused by the use of any other parts or accessories. In order to take account of a policy of continual development, Pulsar Instruments Plc reserves the right to change any of the information contained in this publication without prior notice. Produced by Pulsar Instruments Plc, The Evron Centre, John Street, Filey, North Yorkshire, YO14 9DQ. Copyright Pulsar Instruments Plc Reference Number 06/07/Model 14/01 Document Printing Date Thursday, 26 November 2015

Model 14 Sound Level Meter User Manual Page 3 Overview.... 4 First time use.... 4 Model 14 Instrument Check List... 4 Instrument Controls... 5 Taking Measurements... 7 Fundamental precautions.... 7 Display and Indicators... 8 Display... 8 Indicator... 8 Fitting a New Battery... 9 Field Calibration... 10 Calibration Procedure... 10 Technical Specification... 11 Appendix 1 - CE Declaration of Conformity... 12 Guarantee... 13 Pulsar Instruments Offices... 13

Model 14 Sound Level Meter User Manual Page 4 Overview. Thank you for purchasing the Model 14 sound level meter from Pulsar Instruments plc. This entry level meter is designed to be quick and simple to use when taking basic sound measurements and we are sure it will meet your requirements. The Model 14 is a general purpose digital sound level meter which meets the full requirements of IEC 61672 to Class 2. The instrument has 'F' (Fast) response and has both 'A' and 'C' frequency weightings. In addition facilities are provided to hold the maximum reading occurring throughout the measurement period. First time use. The Model 14 should be inspected for any signs of damage and also to ensure that all relevant accessories are present. Your Model 14 will have been supplied either as a single unit or as part of a full measurement kit, Model 14-K. Model 14 Instrument Check List The Model 14 Sound Level Meter is supplied with the following accessories as standard: Model 14 Class 2 Sound Level Meter 50mm windshield Calibration Screwdriver User Manual Certificate of Calibration 1 x 9V Battery The Model 14 Sound Level Meter can also be supplied as a complete measurement kit, the Model14-K, which includes a Model 106 Class 2 Acoustic Calibrator and a carrying pouch. For further details of the options and accessories for the Model 14 Sound Level Meter, please contact your local representative.

Instrument Controls Model 14 Sound Level Meter User Manual Page 5

Model 14 Sound Level Meter User Manual Page 6

Model 14 Sound Level Meter User Manual Page 7 Taking Measurements Before taking measurements, ensure the instrument has a new or highly charged battery fitted. The instrument is supplied with a battery but it is not fitted for transit. See page 9 for details of fitting and changing the battery. Turn the instrument on by moving the OFF/F slide switch to the F position: > OFF = Instrument is powered off. > F = Fast Time Weighting Allow the instrument to settle for 10 seconds before calibrating or taking measurements. Ensure the instrument is calibrated (see page 10 for details of calibration) Select the required Frequency Weighting using the A/C slide switch: > A = A-Weighting or db(a) > C = C-Weighting or db(c) Select the most appropriate range for the acoustic environment using the H/L slide switch: > L = Low Range (suitable for levels up to 100dBA) > H = High Range (suitable for levels over 65dBA) If the maximum exceeded level is required then press the MAX HOLD button for at least ½ second. Once released the text HOLD is illuminated in the top left of the instrument display. In this mode the highest measured sound pressure level is displayed. To turn off the maximum hold facility either press the MAX HOLD button again or turn the unit off. Fundamental precautions This section contains some simple points that should be considered when using the Model 14 instrument: a) Allow the instrument to settle for 10 seconds after switching on before calibrating or taking measurements. b) Always check the battery before and after each measurement. The Model 14 monitors the battery continuously while operating. c) Ensure that the white MAX HOLD function is turned off when not required. If this is not done, the display will freeze the last reading and the word HOLD will be displayed on the top left of the LCD.

Model 14 Sound Level Meter User Manual Page 8 d) Wherever possible, always check the instrument calibration before and after each measurement. e) Whenever the instrument is not to be used for a long period of time (> one month) then remove the battery completely. This action will prevent leakage damage. Display and Indicators Display The LCD display of the Model 14 is scaled in decibels, either 'A' or 'C' weighted, depending on the position of the A/C slide switch. There are indicators in the display as follows:- Function Indicator Cause and Possible Action Low Battery LOWBAT Battery capacity low, replace battery Maximum Hold MAX HOLD The display is MAX, push MAX HOLD to reset Indicator There are also two status indications above the instrument display, these have the following functions: Function Indication Cause and Possible Action Under Range Green Light The sound level is below the current measurement range. Move the L/H slide to the L position. Overload Red Light The sound level is above the current measurement range. Move the L/H slide switch to the H position.

Model 14 Sound Level Meter User Manual Page 9 Fitting a New Battery 1. Ensure the instrument is turned off before removing the battery cover. 2. Remove the battery cover. 3. The battery is made accessible by pressing the left hand side of the battery cover down slightly and then sliding it to the right. The spent battery can then be removed and disposed of safely. 4. A new battery, IEC 6F22 (NEDA 1604, PP3) can then be fitted. The battery can only be fitted in one orientation. 5. Replace the battery cover by sliding it back into place from right to left.

Model 14 Sound Level Meter User Manual Page 10 Field Calibration It is vital that the calibration of ANY sound level meter is checked before and after each measurement. If this is done, it is reasonable to assume that the calibration during the measurement was correct. If this is NOT done, you will not subsequently be able to be certain that the instrument calibration was correct and you can never be certain the sound level was as measured. This process is commonly referred to as field calibration. The sound level meter is calibrated acoustically using an external reference, e.g the Sound Level Calibrator Model 106, which is placed over the microphone. The calibrator generates a stabilised Sound Pressure Level of 94dB (+- 0.3dB) at a frequency of 1kHz. Calibration Procedure 1. Ensure the batteries are fitted correctly and have sufficient power left. 2. Ensure the MK:268 microphone capsule is fitted correctly 3. Turn the instrument on with the following settings: OFF/F in the F position L/H in the L position A/C in the A position (This relates to Fast Time Weighting, Low Measurement Range and db(a) Frequency) 4. Ensure the MAX HOLD function is not active. (The word HOLD is not displayed in the top left hand corner of the instrument display) 5. Attach the acoustic calibrator and turn it onto the 94dB output setting. An acoustic calibrator such as the Model 106 is suitable. 6. Using the provided calibration screwdriver, slowly adjust the CAL potentiometer until the instrument display reads 93.7dB(A). (Turning the CAL potentiometer clockwise increases the displayed level whereas anti-clockwise reduces the displayed level) Note: Although the Model 106 Acoustic Calibrator has an output of 94dB, the pressure correction of the microphone capsule is 0.3dBA. For this reason the Model 14 must be adjusted to give a reading of 93.7dBA. 7. The instrument is now calibrated. For details of the operation of the Model 105 and Model 106 Acoustic Calibrators, please refer to the user manuals supplied with these units.

Technical Specification Model 14 Sound Level Meter User Manual Page 11 A full technical user manual, including mandated rating plate information is available upon request. Standardisation: IEC 61672-1:2002 Class 2 IEC 60651:1979 Type 2 I Measurement Range: Range Information: 35dB(A) to 130dB(A) 40dB(C) to 130dB(C) L (Low) = 35dB(A) to 100dB(A) > 100dB(A) = over range indicator H (High) = 65dB(A) to 130dB(A) < 65dB(A) = down range indicator > 130dB(A) = over load indicator Frequency Weighting: A & C Weighting to IEC 61672-1:2002 Class 2 Time Weighting: Fast to IEC 61672-1:2002 Class 2 Time constant 125mS Display Functions: Measurement Functions: Display Flags: Reference Point: Display: Resolution: Electrical Outputs: Power: Microphone: Operating Temperature: Storage Temperature: Dimensions: Weight: Normal (Sound Level), Maximum Hold LAF, LCF, LAFMax, LCFMax Over Load (Red Light) Under range (Green Light) Maximum Hold (HOLD) Low battery (LOWBAT) 94dB(A), 1000Hz on Low Range (L) 3 ½ digit LCD Update rate of 1Hz 0.1dB AC Out Max output = 2V, output impedance 600Ohm 1 x 9V (6F22, PP3) External DC Power, 7V to 10V ½ pre-polarised electret condenser type MK:268-10 C to +50 C -20 C to +60 C Length 248mm, Width 66mm, Depth 30mm 227gms (8oz) with battery

Model 14 Sound Level Meter User Manual Page 12 Appendix 1 - CE Declaration of Conformity Pulsar Instruments plc Hunmanby UK CE Certificate of Conformity Manufacturer: Pulsar Instruments Plc Unit 2, Bridlington Road Industrial Estate Hunmanby, Noise Yorkshire United Kingdom Telephone +44 1723 518011 Equipment Description The following equipment manufactured after 1 st January 2007: Model 14 Sound Level Meter Along with their standard accessories According to EMC Directives 89/336/EEC and 93/98/EEC meet the following standards EN 61000-6-3 (2001) EMC: Generic emission standard for residential, commercial and light industrial environments. EN 61000-6-1 (2001) EMC: Generic immunity standard for residential, commercial and light industrial environments. Signed Dated 1 st January 2007 S. O Rourke Director

Model 106 & Model 105 Acoustic Calibrator Page 13 Guarantee Pulsar Instruments Plc offers a 12 month guarantee on all of their units. This covers all parts and labour excepting only damage caused by the user. Because of the unique fragility of microphones, only internal short or open circuits are accepted as faults and not accident damage. The guarantee requires the user to return the unit to their nearest authorised Pulsar Instruments Plc Agent. This guarantee is in addition to any statutory rights in your country. Pulsar Instruments Offices The addresses given below are the Pulsar Instruments Plc offices. Pulsar Instruments Plc also have approved distributors and agents is many countries worldwide. For details of your local representative, please contact Pulsar Instruments Plc at the address below. Contact details for Pulsar Instruments authorised distributors and agents are also available from the Internet Website at the address shown below. Pulsar Instruments Plc The Evron Centre John Street Filey North Yorkshire United Kingdom YO14 9DQ Telephone: 01723 518011 Fax: 01723 518043 e-mail: sales@pulsarinstruments.com Website: www.pulsarinstruments.com