Digital ph transmitter

Similar documents
Digital ph transmitter

Paddle-wheel flow controller for On/Off control

Inductive conductivity meter

Paddle-wheel flow controller for On/Off control

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Inductive conductivity meter

Insertion magnetic inductive flowmeter

INSERTION flow sensor for continuous flow measurement

Positive displacement batch controller

INSERTION Adaptor for analysis

Paddle-wheel flow controller with optical principle for On/Off control

INSERTION flowmeter with paddle wheel, ELEMENT design

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Probe holders for analytical probes

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Positive displacement flowmeter

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Positive displacement flowmeter for continuous flow measurement

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

MAGNETIC INDUCTIVE FLOW TRANSMITTER

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

INSERTION Adapter/Fitting for analytical devices

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Electrical position feedback for actuator sizes Ø mm

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Conductivity Measuring Cells ConduMax W CLS 19

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Temperature Sensor without thread

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Plastic tube variable area flowmeter for liquids and gases

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

2/2-way Solenoid Valve with servo diaphragm

INLINE fitting with paddle-wheel for flow measurement

Inline Paddle Wheel Flow Switch

2/2 or 3/2 way direct acting rocker solenoid valve

INSERTION fitting for flow measurement or analysis

3/2-way Solenoid Valve, direct-acting, NC or NO

Pneumatic control unit for decentralized automation of ELEMENT process valves

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Level Measurement Point level measurement - RF Capacitance switches

Signet 2551 Magmeter Flow Sensor

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Continuous level sensor NSK

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Fluid Control System with Diaphragm Valve For Polluted, Dirty, Aggressive and Ultra-Pure Fluids

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Direct-acting 3/2 way plunger valve

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

SATRON VTe pressure transmitter

Pressure transmitter COMPACT ECOnomic

JUMO ecotrans Lf 01/02

Simple float switch TCL001/8181

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Operating Instructions (from serial number 3000)

Flow switches Series AD/VH

Differential Pressure Sensors

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Signet 3719 ph/orp Wet-Tap Assembly

Electromagnetic Flow Monitor magphant

Differential Pressure Sensors

3/2-way Solenoid Valve for pneumatics

2/2- and 3/2-way solenoid valve for aggressive fluids

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

EXNER PROCESS EQUIPMENT

Metal tube variable area flowmeter for gases, liquids and steam

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

SATRON VDt Differential Pressure Transmitter

AirLINE and AirLINE Quick electrical/pneumatic Automation System

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

ph-kompaktelektrodensystem sensopac CPA 320

mass flowmeter for compressed air

Solenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Continuous level sensor NSK

Electromagnetic Flow Monitor magphant

Technical Features Flow Monitor Part No. Wire Associated Sensor 4-20 ma Digital Relay Power Tech. Sensor Input Output Output Output F9.00.L 2 wire Hal

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

Model Q45H/ Residual Chlorine Monitor...

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Transcription:

Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings Multi language, menu-guided operation Type 8205 can be combined with... Type S020 Type 6642 Type 2731 Type 2030 Type 8644 PLC INSERTION fitting Solenoid valve Diaphragm valve for continuous control On/Off Diaphragm valve Valve islands The ph transmitter is available in different models: Compact ph transmitter with integrated ph electrode Remote ph transmitter, for panel or wall mounting, to connect to the Bürkert Type 8200 ph sensor (max. 10m). The ph transmitter or sensor can be installed into pipes by using INSERTION Type S020 fittings or other suitable installation materials. It can also be installed in tanks or containers by using an industrial immersion fitting. Technical data (common to the various versions) General data Display Electrical connections Environment Relative humidity Standards and approvals Standard EMC Security Vibration Shock 15 x 60 mm, 8-digit LCD, alphanumeric, 15 segments, 9 mm high shielded cable with 1.5 mm 2 max. cross-section 80 %, non condensated EN 61000-6-2, EN 61000-6-3 EN 61010-1 EN 60068-2-6 EN 60068-2-27 www.burkert.com p. 1/12

System versions The compact version combines a ph sensor and an electronic module with a display in an IP65 enclosure. The access to the output terminals are provided via two cable glands or a cable plug EN175301-803. The panel-mounted version consists of an electronic module 8205 integrated in a front-cover. The associated separate ph sensor is Type 8200. The output signals are provided on a terminal strip. The wall-mounted version consists of an electronic module 8205 in an IP65 enclosure. The associated separate ph sensor is Type 8200. The output signals are provided on a terminal strip via cable gland. Bürkert designed fitting ensures simple direct installation of the Bürkert transmitter into pipes from DN 15 to DN 200. Operation and display Customized adjustments, such as measuring range, engineering units can be carried out menu-supported on site via a multi-lingual display. The operation is classified according to three levels. Main Menu - ph - temperature - output current - electrode voltage - HOLD function - ph electrode calibration Calibration Menu - language - temperature unit - measuring range 4-20 ma - relay parameter definition - selection of temperature compensation (Pt1000 or manual) - display or not of electrode voltage in main menu - filter selection Direction upwards in menu Choice of digit values Steps from 0 to 9 Accept of chosen parameter or adjusted value Test Menu - Offset - Span - temperature adjustment - simulation of ph Direction downwards in menu or sideways for digit selection Relay 2 LED (contact closed) Relay 1 LED (contact closed) p. 2/12

Compact ph transmitter Type 8205 The sensor component consists of a replaceable combination ph-electrode, screwed into the sensor housing. The measured signal is conveyed to the transmitter via a coax plug. The Pt1000 for automatic temperature compensation is a standard feature in the sensor housing. The transmitter component converts the measured signal, displays the actual value and computes the output signals. Pressure / temperature chart Pressure (bar) 7 PVDF Metal 6 5 4 3 2 1 0 PVC + PP PVC +10 +30 +50 +70 Temperature ( C) Principle of operation PVDF PP The most important part of the ph transmitter is the ph electrode with its ph selective glass membrane. When the electrode is immersed into the solution, an electrical charge caused by ions (H+) generates a cell voltage between the glass membrane and the solution. This electrical voltage is measured with reference to a reference electrode, located around the ph glass electrode. The cell voltage of the combination electrode is directly proportional to the ph value. The transmitter functions in a two wire circuit (without relay) or three wire circuit (with relays - limits values freely adjustable) and requires a power supply of 12... 30 V DC. A 4... 20 ma standard signal proportional to the ph or to the temperature ( C) is available as output signal. General data Compatibility Materials Housing, cover, lid, nut Front panel foil / Screws Cable plug, glands Wetted parts materials Fitting Sensor holder / Pt1000 Seal Electrode with fittings S020 (see corresp. datasheet) PC Polyester / Stainless steel PA Brass, stainless steel 1.4404/316L, PVC, PP or PVDF PVDF / Stainless steel 1.4571 (316Ti) FKM (EPDM included in delivery) UNITRODE ph Electrical connections Cable plug EN 175301-803 or cable glands M20 x 1.5 Complete device data (Fitting + Electronics) Pipe diameter DN 15 to 200 ph measurement Measuring range Resolution Accuracy Minimal range Temperature measurement Measuring range Resolution Accuracy Temperature compensation 0...14 ph 0.01 ph ±0.02 ph, after proper electrode calibration 0.5 ph unit (i.e 6.7 to 7.2 corresponding to 4-20 ma) -30 to +140 C 0.1 C ± 1 C automatic (integrated Pt1000) or manual (user programmed) - reference temperature 25 C Medium temperature max. with fitting in PVC: 50 C - PP: 80 C - PVDF: 100 C - stainless steel, brass: 130 C Fluid pressure max PN6 (see pressure / temperature chart) Electrical data Power supply Current consumption with sensor Output Relays (option) Environment Ambient temperature Operation Storage Standard Protection class 12-30 V DC, filtered and regulated 80 ma - transmitter with relays 20 ma - transmitter without relay 4-20 ma programmable, proportional to ph or T C max. loop impedance: 1000 Ω at 30 V DC; 750 Ω at 24 V DC; 250 Ω at 15 V DC 2 relays, freely programmable, 3A, 230 V AC 0 to +60 C 4 to 30 C (limited through the electrode) IP65 with cable gland mounted and tightened or with obturator locked if not used. Specific technical data: Electrode UNITRODE ph Fluid - Clean (drinking water, aquarium, swimming pool...) - Contamined (effluent rinse water, cooling water, electroplating, paints, cosmetics...) - with low conductivity (pure and rainwater...) - containing sulfides/proteins (tannery, animal breeding, effluent, foodstuffs, cosmetics, biotechnology...) Measuring range 0... 14 ph Min. conductivity 2 μs/cm (200 kω.cm) Housing glass shaft Medium pressure 0-6 bar Medium temperature 0-130 C Max. pressure at max. temperature 4 bar Diaphragm Two clogging free Single pores Reference electrolyte polymer p. 3/12

Installation The 8205 ph transmitter can easily be installed into any Bürkert INSERTION fitting system (S020) by just fixing the main nut. Mount the compact ph transmitter in vertical position (max. ±75 ) into a horizontal pipe. The electrode must continuously be immersed into the measuring fluid in order to protect it from drying out. 75 75 The transmitter must be protected from constant heat radiation and other environmental influences, such as direct exposure to sunlight. An industrial immersion kit allows installation of this transmitter into tanks or containers. The following lengths are available: 500, 1000, 1500, 2000 mm. Special lengths on request. Dimensions [mm] 180 Compact version Immersion kit Ø 145 Ø 91 L 123 110 113 L [mm] 500 1000 1500 2000 88 88 85.5 21 (190) 91 88 116 88 90 126 200 H DN H [mm] [mm] T-Fitting Plastic St. St. spigot spigot 15 187 20 185 25 185 32 188 40 192 50 198 193 65 198 206 199 80 212 204 100 219 214 110 125 254 225 150 261 236 180 200 282 257 L Ø 75 Ø 104 Ø 145 * using fusion spigot ( 418652, 418660 or 418644 in PP, PVDF or PE) for orifice DN 65-200 p. 4/12

Remote ph transmitter Type 8205 (for connection to Bürkert sensor Type 8200) The remote ph transmitter Type 8205 is available in 2 versions: - Panel-mounted ph transmitter General data Compatibility Bürkert ph sensor Type 8200 Materials Housing, cover Front panel foil Screws Cable plug, glands Electrical connections PC (panel-mounted version); ABS (wall-mounted version) Polyester Stainless steel PA Terminals (panel-mounted version) or terminals via 5 cable glands M16 x 1.5 (wall-mounted version) - Wall-mounted ph transmitter A separate compact ph sensor 8200 from Bürkert must be associated with this remote ph transmitter. This sensor Type 8200 must be ordered separately. Technical specifications 115/230 VAC Voltage supply 27 V DC regulated, max. current: 250 ma integrated protection: fuse 250 ma temporised power: 6 VA Electrical data Power supply Panel-mounted version Wall-mounted version Current consumption with sensor Sensor input Cable length Output Relays (option) Environment Ambient temperature Operation and storage Standard Protection class 12-30 V DC, filtered and regulated 12-30 V DC, filtered and regulated or 115/230 V AC - 50/60 Hz (see technical specifications 115/230 VAC) 80 ma - transmitter with relays 20 ma - transmitter without relay Analog signal from ph electrode and Pt1000 max. 10 m (distance between sensor and transmitter) 4-20 ma programmable, proportional to ph or T C max. loop impedance: 1000 Ω at 30 V DC; 750 Ω at 24 V DC; 250 Ω at 15 V DC 2 relays, freely programmable, 3A, 230 V AC 0 to +60 C IP65 (panel-mounted and wall-mounted version) IP20 (panel-mounted version, inside the cabinet) Dimensions [mm] Panel-mounted version Wall-mounted version 88 76 41 25 126 23 23 24 48 120 140 90 88 25.5 p. 5/12

Remote ph sensor Type 8200 (for connection to Bürkert transmitter Type 8205) A wide range of ph holders enable ph measurement in various applications. General data Compatibility Materials Fitting Sensor holder G2 connection G1 connection Sanitary Triclamp Pt1000 Seal with all fittings S020 (see corresp. datasheet) Brass, Stainless steel 1.4404/316L, PVC, PP or PVDF Stainless steel, PVC, PP, PVDF PVC Stainlesss steel (316Ti / 1.4571), DN40, 50 Stainless steel (316L / DIN 1.4404) Stainless steel 1.4571 (316 Ti) FKM (EPDM option) Electrode Type UNITRODE ph 120 Type LOGOTRODE ph 120 Type MECOTRODE Electrical connections Coaxial shielded cables with connector for ph and 4-wire cable for Pt1000 A complete ph sensor system consists of (see installation example of Type 8200): A. complete armature with seals installed on: 1. Bürkert Fitting (G2 connection) 2. G1 connection 3. Tri-Clamp connection 4. Sanitary connection (according to DIN11851) B. ph-electrode C. Pt1000 (option) D. ph+pt1000 shielded cable (2, 5 or 10 m) Complete device data (fitting + sensor) Pipe diameter DN 15 to 200 Measuring range 0... 14 ph (depends on electrode) Medium temperature max. Temperature compensation with UNITRODE ph 120 or MECOTRODE and fitting in PVC: 50 C - PP: 80 C - PVDF: 100 C - stainless steel, brass: 130 C with LOGOTRODE ph 120: 50 C automatic (integrated Pt1000) or manual compensation reference temperature 25 C Tri-Clamp is a registered Trademark of Alfa Laval Inc. Electrical data Output Analog signal, to be connected to remote electronic module Type 8205 Specific technical data Electrode LOGOTRODE ph 120 UNITRODE ph 120 MECOTRODE Fluids - Clean like drinking water, aquarium, swimming-pool - Contamined like effluent rinse water, cooling water, electroplating, paints, cosmetics - containing sulfides/proteins like tannery, animal breeding, effluent, foodstuffs, cosmetics, biotechnology - Higher pressure applications Measuring range 2... 14 ph 0... 14 ph 0... 14 ph Fluid pressure 0-2 bar 0-6 bar 1) 0-16 bar 1) Temperature -10 to +60 C 0 to +130 C 0 to +130 C Ambient temperature Operation Storage 0 to +60 C 4 to +30 C 0 to +60 C 4 to +30 C 0 to +60 C 4 to +30 C Minimal conductivity 2 μs/cm 2 μs/cm 50 μs/cm Max. pressure at max. temperature 2 bar 4 bar 3 bar Number of diaphragms 1 2 3 Diaphragm single pore single pore HP ceramics Reference electrolyte polymer polymer gel 1) only 0-3 bar if used with holder Type 8200 with Tri-Clamp or sanitary connection and with protection tube p. 6/12

Installation of Type 8200 Holder for Type S020 horizontal mounting Holder for connection 1 horizontal mounting C D A B A. complete armature with seals installed on: 1. Bürkert Fitting S020 (G2 connection) 2. G1 connection 3. Tri-Clamp connection 4. Sanitary connection (according to DIN11851) B. ph-electrode C. Pt1000 (option) D. ph + Pt1000 shielded cable (2, 5 or 10 m) (option) E. PVC adapter piece 1) Holder long version 2) Holder short version A 1) D A 2) E* 1 * With standard PVC connection. Not in Bürkert program C 2 B 2 C B 75 75 First select and install the required fitting into a horizontal pipe, according to specific requirements of the sensor and material (temperature and pressure). After having connected the ph sensor to the Type 8205 transmitter and having calibrated the unit, cautiously install the complete ph sensor in vertical position (max. ±75 ) on the fitting. The electrode must continuously be immersed into the measuring fluid in order to protect it from drying out. The sensor must be protected from constant heat radiation and other environmental influences, such as direct exposure to sunlight. Dimensions [mm] ph holder Type 8200 for installation on Bürkert Fitting S020 (G2 connection) - PVC, PP, PVDF, Stainless steel Ø 56 154 30 133 53 (71) Ø 76 Ø 26 p. 7/12

117 18 39.5 8205 Transmitter / Dimensions [mm] ph holder Type 8200 for G 1 connection - PVC short version long version 64 44 Ø 42 Ø 42 154 133 G1 84 104 133 154 G1 Ø 26 Ø 26 ph holder Type 8200 for Tri-Clamp connection - Stainless steel 316L ø A ø B ø A ø B 1 1/2 42.4 50.5 2 53 64 ø 17.2 ø 5 ø 30.1 ph holder Type 8200 for sanitary connection (according to DIN 11851) - Stainless steel 316Ti Ø C E 18 39.5 Ø D 117 DN ø C ø D E 40 48 56 10 50 61 68.5 11 Ø 17.2 Ø 5 Ø 30.1 p. 8/12

Measuring chamber for ph transmitter Type 8205 The specially designed measuring chamber enables to install all ph-transmitters or electrodes in all pipe systems, either directly in the main stream or in a by-pass line. Additionnaly it enables to keep the electrode always wet and isolate it easily from the main stream for calibration purposes. ø 60.3 17.6 ø 60 B-B ø 33.6 ø 27 2.70 80.2 41 62.6 B B Combining the ph transmitter Type 8205 with fittings Type S020 Available fitting DN T-fitting S020 Welding tab S020 Fusion spigot S020 DN 15 DN50 DN65 DN65 DN200 DN200 ph measurement 8200-8205 compact DN 15 DN200 ph measurement 8205 remote version DN15 Note A DN32 DN200 Note A: Use only with plastic fitting with true union acc. to DIN 8063 p. 9/12

Ordering chart for compact transmitter Type 8205 A compact ph transmitter Type 8205 consists of: - an INSERTION ph transmitter 8205 - an INSERTION fitting Type S020 (DN15 - DN 200) (Refer to corresponding datasheet - has to be ordered separately) Specifications Voltage supply Output Relays Sensor version Electrical connection Compact 12-30 V DC 4-20 ma None UNITRODE ph EN 175301-803 418 834 2 cable glands 418 843 2 UNITRODE ph 2 cable glands 418 835 1) FKM gasket in standard; 1 Kit including a black EPDM gasket for the sensor, an obturator for an M20 x 1.5 cable gland, a 2 x 6 mm multiway seal and a mounting instruction sheet is supplied with each transmitter with cable glands or 1 Kit including a green FKM and a black EPDM gaskets is supplied with each transmitter with connection EN175301-803. Ordering chart for accessories for compact ph transmitter Type 8205 Description Set with 2 cable glands M20 x 1.5 + 2 neoprene flat seals for cable gland or plug + 2 screw-plugs M20 x 1.5 + 449 755 2 multiway seals 2 x 6 mm Set with 2 reductions M20 x 1.5 / NPT1/2 + 2 neoprene flat seals for cable gland or plug + 2 screw-plugs M20 x 1.5 551 782 Set with 1 stopper for unused cable gland M20 x 1.5 + 1 multiway seal 2 x 6 mm for cable gland + 1 black EPDM 551 775 gasket for the sensor + 1 mounting instruction sheet Ring 619 205 PC - nut 619 204 Set with 1 green FKM + 1 black EPDM gasket 552 111 Electrode holder with stainless steel Pt1000 418 889 Electrode holder with titanium Pt1000 418 890 ph electrode 0... 130 C, 0... 6 bar - UNITRODE ph 552 041 Cable plug EN 175301-803 with cable gland (Type 2508) 438 811 Cable plug EN 175301-803 with NPT1/2 reduction (Type 2509) - UR and UL approval 162 673 Compact ph transmitter for tank installation consists of: - an INSERTION ph transmitter - an extension cable for immersion fitting - an immersion fitting - a fixing kit - Flange DN65 with stainless steel screws Description Immersion fitting - PP - 0.5 m 419 567 Immersion fitting - PP - 1.0 m 419 568 Immersion fitting - PP - 1.5 m 419 569 Immersion fitting - PP - 2.0 m 419 570 Extension cable for immersion fitting - PP - 0.5 m 416 632 Extension cable for immersion fitting - PP - 1.0 m 416 633 Extension cable for immersion fitting - PP - 1.5 m 416 634 Extension cable for immersion fitting - PP - 2.0 m 416 635 Fixing kit - Flange DN 65 with stainless steel screws 413 615 p. 10/12

Ordering chart for remote transmitter Type 8205 A complete remote transmitter Type 8205 consists of: - a ph-transmitter Type 8205 (wall-mounted or panel-mounted version) - a ph- holder Type 8200 - a ph-electrode Type 8200 (see accessories) - a shielded connection cable (ph and Pt1000 signal) (see Accessories) - a Pt1000 temperature sensor (see Accessories) - an INSERTION fitting S020 (DN15 - DN 200) (Refer to corresponding datasheet - has to be ordered separately) ph transmitter Type 8205 panel or wall-mounted version Specifications Voltage supply Output Relays Sensor version Electrical connection Panel-mounted 12-30 V DC 4-20 ma None 8200 Terminal strip 427 937 2 8200 Terminal strip 427 938 Wall-mounted 12-30 V DC 4-20 ma None 8200 cable glands 427 944 2 8200 cable glands 427 945 115-230 V AC 4-20 ma None 8200 cable glands 427 949 2 8200 cable glands 427 950 Ordering chart - ph holder for remote transmitter Type 8205 Specifications Sensor version Material Boring for temperature sensor Pt1000 Protection tube ph-holder 8200 for installation on Bürkert fitting S020 standard PVC Yes Yes 429 228 (G2 connection) PP Yes Yes 429 229 PVDF Yes Yes 429 230 Stainless steel Yes Yes 429 231 ph-holder 8200 for G1 connection thread short PVC Yes - 429 221 long PVC Yes - 429 223 ph-holder 8200 for Tri-Clamp 1 1/2 - (dia. 50.5 mm) standard Stainless steel 316L Yes - 429 235 ph-holder 8200 for Tri-Clamp 2 - (dia. 64 mm) standard Stainless steel 316L Yes - 429 239 ph-holder 8200 for sanitary connection DN40 - (DIN 11851) standard Stainless steel 316Ti Yes - 429 247 ph-holder 8200 for sanitary connection DN50 - (DIN 11851) standard Stainless steel 316Ti Yes - 429 255 Ordering chart for accessories for remote ph transmitter Type 8205, ph sensor Type 8200 Description ph electrode 0... 50 C, 0... 2 bar, ph 2... 14 - LOGOTRODE ph 120 mm 427 114 ph electrode 0... 130 C, 0... 16 bar, ph 0... 14 - MECOTRODE ph 120 mm 418 319 ph electrode 0... 130 C, 0... 6 bar, ph 0... 14 - UNITRODE ph 120 mm 448 685 Temperature probe -Stainless steel sensor Pt1000 427 023 ph coaxial cable with standard electrode plug - 2 m (for connection between 8205 controller and 8200 sensor) 427 024 ph coaxial cable with standard electrode plug - 5 m (for connection between 8205 controller and 8200 sensor) 427 025 ph coaxial cable with standard electrode plug - 10 m (for connection between 8205 controller and 8200 sensor) 432 660 pt1000 4-wire cable with M8 connector - 2 m (for connection between 8205 controller and 8200 sensor) 427 110 pt1000 4-wire cable with M8 connector - 5 m (for connection between 8205 controller and 8200 sensor) 427 113 pt1000 4-wire cable with M8 connector - 10 m (for connection between 8205 controller and 8200 sensor) 554 822 FKM gasket for all holders Type 8200 429 264 EPDM gasket for all holders Type 8200 429 265 p. 11/12

Ordering chart for accessories for all version of Type 8205, Type 8200 Description Storage solution for electrodes (KCl 3M), 500 ml 418 557 Buffer solution, 500 ml, ph = 4 418 540 Buffer solution, 500 ml, ph = 7 418 541 Buffer solution, 500 ml, ph = 10 418 543 Factory 2-point ph calibration certificate 550 673 Measuring chamber stainless steel 316L (1.4404) 1) with G 1/2 connection thread 553 611 1) other materials on request Note: Compact ph transmitter 8205, remote (Wall-mounted or Panel-mounted versions) ph electronic module 8205, ph holder 8200, ph electrode, Pt1000 sensor, connection cable, INSERTION fitting S020, have to be ordered separately. Interconnection possibilities with other Bürkert devices Type 2030 - Diaphragm- Valve with pilot valve Type 2031 - Process Valve with positioner Printer - Type 8205 - Wall-mounted or panel-mounted Type 8205 - Compact ph transmitter Type 8200 - ph sensor Type S020 - INSERTION Fitting (see corresp. datasheet) Measuring chamber To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. We reserve the right to make technical changes without notice. 0705/4_EU-en_00891800 p. 12/12