Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

Similar documents
Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

ELECTRICAL. Contents - Wiring Diagrams

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

Coleman Air Diversion Controller Model C40

Coleman Air Diversion Controller Model C40

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

BASIC ELECTRICAL MEASUREMENTS By David Navone

17429X.00 SERIES MODELS:

Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace

Electrical Systems. Introduction

Which one? All are capable of doing the job

ST Charger. Industrial Battery Charger

WORKSHOP MANUAL ELECTRICITY

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

1) READ THE M500 INSTRUCTIONS CAREFULLY TO GET A FULL UNDERSTANDING OF THE M500 AND HOW IT OPERATES.

GENERAL <ELECTRICAL>

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

Troubleshooting Guide for N1225-1/N1237-1/N Alternators

STARTER SYSTEM TESTING 5.6

IMPORTANT SAFETY INSTRUCTIONS

MODEL No s: PP3, PP3K

DYNAMO & ALTERNATOR - B FIELD LOGIC PROBE.

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

Coleman Air C440-HVM 440 Amp Diversion Controller Version 3.2

TRAIL CHARGER with EXTENDER and COMBO NOSE BOX

CHAPTER 2. Current and Voltage

with lcd display 12-42v

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

GENERAL <ELECTRICAL>

ENGINE ELECTRICAL Click on the applicable bookmark to selected the required model year

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

N1233 Series Troubleshooting Guide for N Alternator

Electromagnetic Induction (approx. 1.5 h) (11/9/15)

Models: SP3, SPSS3 Automatic Battery Charger

Chrysler Electronic Ignition System

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Just what is an alternator?

STARTER SYSTEM TESTING 5.6

DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO SRM 294

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

MBCM-24 MULTIPLE BATTERY CHARGING MODULE (FOR MARINE APPLICATIONS) FEATURES SPECIFICATIONS APPLICATIONS DESCRIPTION & OPERATION ORDERING INFORMATION

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

TABLE OF CONTENTS STANDARD FEATURES

Sentry Battery Charger. Installation and Operations Manual Section 75

STARTING SYSTEM (1ZZ FE) (April, 2003)

LAB 7. SERIES AND PARALLEL RESISTORS

SBC / 2140 / Stage Battery Charger User Manual

Devices installed in a race car should be divided into two categories: power devices and control devices.

Troubleshooting Bosch Proportional Valves

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

DC motor theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

Unit 10 Measuring Instruments

Electricity. Chapter 20

Experiment 3. The Direct Current Motor Part II OBJECTIVE. To locate the neutral brush position. To learn the basic motor wiring connections.

BELT-DRIVEN ALTERNATORS

User s Manual. Automatic Switch-Mode Battery Charger

ELECTRICAL. CDTA Technical Training Center

Electrical Testing in the Operating Room; Part 6

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831)

34.5 Electric Current: Ohm s Law OHM, OHM ON THE RANGE. Purpose. Required Equipment and Supplies. Discussion. Procedure

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

DC POWER SUPPLY ALIMENTATION C.C.

600 Series Troubleshooting Guide for C651 and C654 Alternators

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

700B CONTROL SERIES. Instruction Manual Low Voltage DC Brushless Control CONTROLS. Phone (317) Fax (317)

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Manual Installation & Operation

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

LV2000. revision 1.5. Low Voltage Power Supply Retrofit Kit for Wells-Gardner Color XY Monitor, model 19K6100. Installation Instructions ! WARNING!

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

PHOENIX HV Features of the Phoenix HV-45 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

Euclid Full Voltage Magnet Controller

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

C TROUBLESHOOTING SIENNA (EWD613U) VOLTAGE CHECK CONTINUITY AND RESISTANCE CHECK

Duo Battery Charge Controller

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

730 CONTROL SERIES. Instruction Manual CONTROLS. Low Voltage DC Brushless Control. Phone (317) Fax (317)

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

ALTERNATOR - CHRYSLER 40/90-AMP & 50/120 AMP

Battery. Charger Model: Save Important Safety Instructions

Coleman Air Diversion Controller Model C160M Version 4.3 With Extended Diversion Mode

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

A3Z OPERATING MANUAL

A6Z OPERATING MANUAL

CURTIS TRANSISTOR MOTOR CONTROLLER

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

SP6. Automatic Battery Charger. Model

HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

Transcription:

DR310 TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

INTRODUCTION The Clover Systems DR310 is an allelectronic voltage and current regulator for dynamos used in vintage cars, trucks, tractors, motorcycles, and boats. It is designed to be used with Lucas dynamos, although it can work with other dynamos as well. INSTALLATION Figure 1 With Lucas Cover Figure 2 - Connections 1) First, be sure that you have the correct model DR310 for your vehicle (Positive or Negative Earth, 6 or 12 volts, and correct current limit to match your dynamo). Although DR310 is protected against most every possible problem, it is possible to damage the unit and/or your generator if for instance, the battery is hooked up backward (see below). 2) Disconnect the battery ground cable to prevent any mishaps. 3) Next, label all wires connected to your existing regulator. With RB340, the wires are (left to right, viewed from the front) D (Dynamo Armature), WL (Warning Light), F (Field Coil), B (Battery1), and B (Battery2). The two B terminals are connected together. One goes to the battery, and the other goes to the vehicle s ignition switch and lights. Since they are connected together, it doesn t matter which wire goes on which terminal DR310 Instruction Manual Pg. 1

If you do not already have a regulator connected, you may need to trace the wires to see exactly where they go. 4) The WL terminal is connected directly to the D terminal. If your vehicle doesn t have a warning light connection, it can be left open. On the Lucas regulator, the WL terminal is to the left of the D terminal, but on ours, it is to the right. 5) The DR310 (like the Lucas RB 310) is grounded to the chassis via the single mounting bolt. Be sure that the right hand mounting bolt is making good connection to the chassis. Ideally, you should check the connection with an ohmmeter. If the DR310 is not grounded, the dynamo output will not be properly regulated. 6) If you are installing a new generator, or your existing one is in unknown condition, you should perform some simple tests to verify that it is workable: a. With an ohm-meter, you should measure resistance of ~ 2 ohms from terminal D to ground. If the resistance is infinite, then either the wire from D to the generator is not connected, or the generator s armature is open. b. Similarly, you should measure resistance of ~ 5-6 ohms from terminal F to ground. Infinite resistance indicates the wire from terminal F to the generator s field coil is not connected, or the field coils are open. A low resistance indicates partial shorting of the field coils to ground. 7) Attach the wires to the DR310, and mount the DR310 using the three stainless steel hex cap screws provided. 8) Reconnect the battery ground. If there is excessive sparking, there may be a wiring mistake. 9) If everything seems to be in order, start the engine and observe the ammeter and ignition warning light. If everything is working correctly, the warning light should go out at around 900 RPM (depending on generator model). You should also be able to see charging of the battery on the ammeter. 10) If there is no output from the generator, and it passed the above tests, see the troubleshooting section in the appendix. 11) Installing the cover. DR310 does not include the Lucas cover. You can however, use your existing cover, or find a used one. There are two styles of RB 310 cover: One has a flange and is held by two short screws. The other has no flange and is held by two long screws. In the case of the cover with the flange, use the two #8-32 machine screws included. If yours uses the long screws, you will have to use your original screws, or let us know DR310 Instruction Manual Pg. 2

and we can send appropriate screws. DR310 has mounting holes for both styles of cover. 12) DR310 with screw terminals comes with the screws and wire clamps, but you can also use your originals if you prefer. Caution Although the DR310 is protected against most everything that can go wrong, there are some things that can damage the DR310 and/or your dynamo: 1) Connecting the battery backward. Be sure that you have the correct polarity regulator. If there is any doubt, check the battery connections to see which battery terminal is connected to the vehicle s chassis. 2) Reversing the D and B wires will create a direct path from the battery to the dynamo s armature, which could damage your dynamo. 3) If the F wire is shorted to the D wire (dynamo armature), the dynamo will run at full output without any voltage or current limiting. Lucas regulators and wiring are made so that you cannot connect the F wire to the WL terminal (which is connected to the D terminal). We have copied this scheme, but if your wiring is not original, it may be possible to accidentally connect the F wire to the WL terminal. 4) If the DR310 is not connected to chassis ground with the right-hand mounting bolt, the regulator will not work properly. TESTING & CALIBRATION Figure 3- DR310 with Screw Terminals The DR310 voltage and current limits are set at the factory to match your dynamo, so normally, no adjustment is required. Test and calibration results are printed at the back of this manual. You may however, wish to confirm that everything is working properly, or change the settings to accommodate your needs. Both voltage and current limit are user adjustable. In the standard configuration, Voltage limit is adjustable from 5v to 17v, and current limit is adjustable from 7A to 30A. In other configurations, current limit can be up to 55A. Adjustment to the voltage or current limit must be carried out on the car. For these adjustments, you will need an analog moving-coil voltmeter (0-20V) DR310 Instruction Manual Pg. 3

and/or analog moving-coil ammeter (0-40A) plus a very small flat-blade screwdriver. Note: Use only analog moving-coil voltage and current meters for these tests. Digital meters will not read correctly because of rapid variations and noise in the dynamo output. Voltage Limit Test (open circuit): 1) Remove the die-cast cover by removing the three screws from the back of the unit: Figure 4 - Cover Mounting Screws 2) Remove both wires from the B terminals, and connect them together with a clip lead. This will provide power from the battery to the vehicles electrical system so the engine can run. 3) Connect an analog voltmeter capable of measuring 0-20 volts between the B terminal of the regulator and ground. 4) Now start the engine. As you increase the engine speed, you should see an increase in the voltage on the meter. Run up the engine speed, and you should see the voltage rise with engine RPM, until it reaches it s preset limit (See the Final Test Sheet at the end of this manual for the proper voltage). 5) If necessary, adjust the voltage limit control to get the desired output voltage limit. Turn the pot clockwise to increase the limit, and counter- DR310 Instruction Manual Pg. 4

clockwise to lower the voltage limit. You should be able to reach the voltage limit at no more than 3000 or 4000 RPM. 6) When finished, remove the voltmeter and re-attach the wires to the B terminals. Voltage Adjust Current Adjust Figure 5 Location of Pots The correct voltage limit also depends on they type of battery. The requirements for flooded type batteries, where you can add water are different than for sealed, Maintenance Free batteries, also known as VRLA, AGM, or Gel batteries, which require a lower charging voltage. The chart below shows optimal settings for the two types of batteries. We normally set the voltage at 14.3V at 25 C for 12v dynamos, and 7.2v for 6v dynamos, which is safe for all batteries. Since there are many types and models of batteries, you may wish to consult the battery specs for the optimum charging voltage. Voltage vs. Temperature 16 15.5 15 Volts 14.5 14 Flooded VRLA 13.5 13 12.5 10 15 20 25 30 35 40 C Figure 6 - Voltage vs. Temperature DR310 Instruction Manual Pg. 5

If the car has been running with substantial electrical load, the regulator will be hotter than ambient temperature. Therefore, it is best to perform the test with the regulator at ambient temperature. Current Limit Test: 1) With the two B wires disconnected from the DR310, and connected together, connect a 0-40A ammeter between the B terminal of the regulator and the two B wires connected together. If your vehicle is negative ground, then connect the + terminal of the ammeter to the B terminal of the regulator, and the terminal of the ammeter to the two wires. For positive ground, reverse these connections. Figure 7 - Ammeter Hookup 2) Start the engine and turn on all loads such as headlights, fans, etc. As you increase the engine RPM, you should see the current flow increase until it reaches the preset limit. You may need to add additional loads to reach the desired limit. 3) Turning clockwise increases the limit, and counter-clockwise decreases the limit. 4) When finished, remove the ammeter and re-attach the wires to the B terminals. Warning: Do not adjust the current limit higher than the rated output of your dynamo, as this may overload the generator and reduce it s life. Note: Typically, the ammeter in your vehicle only measures current to and from the battery. It does not measure the total output of the generator, which could be more. To measure total generator output, you need to connect an ammeter as described above. DR310 Instruction Manual Pg. 6

APPENDIX History Previous to the 1970 s, vehicles used DC generators rather than the AC alternators used today. This was due to the lack of high-power semiconductor rectifiers at the time. In order to provide adequate power without destroying the battery, some means of controlling the generator s output voltage and current is required. This was accomplished using mechanical relays. When the output voltage reaches a predetermined value, a relay opens to cut off the current to the field coils. As the voltage now drops below the threshold, the relay closes, restoring current to the field coils. The rapid opening and closing of the relay regulates the output to a preset limit. Current can be controlled in the same way, but now determined by the current draw from the generator. Regulators previous to the 60s typically did not have any current regulation. Furthermore, power is supplied only when the output of the generator is greater than a preset value (the cut-in voltage ). This prevents the battery from discharging through the armature of the generator when the output of the generator is less than the battery voltage. Although this scheme can do the job, there are some drawbacks: 1) The contacts of the relays become dirty, corroded, and burned, causing unreliable operation and failure. The contacts must periodically be cleaned, and adjusted. 2) The cut-in voltage is fixed, so that the generator must reach a fairly high voltage before it can supply any power to the battery or electrical systems. The Clover Systems DR310 works in the same way, but substitutes transistor switches for the mechanical relays. As a result, switching is cleaner and more reliable, and no cleaning or adjustment is ever required. With the DR310, power is output whenever the generator voltage is higher than the battery voltage. This typically means that useful power can be supplied at a lower RPM. DR310 also includes current limiting, which is not included in most mechanical regulators. How the regulator works All generators work by rotating a loop of wire in a magnetic field. In a dynamo, the magnetic field is created by electromagnets (field coils). Voltage and current are controlled by controlling the current to the field coils. The current through the field coils determines the strength of the magnetic field that the DR310 Instruction Manual Pg. 7

armature rotates in, and thus the output of the generator. In the DR310, the output voltage of the generator is compared to a precision voltage reference. When the generator output exceeds this reference, the current to the field coils is cut off. This causes the generator output to fall. When the output falls below the reference voltage, the field current is turned back on. In this way, the field current is modulated at a rate of 50 125 Hz. These rapid changes are smoothed out by the inductance of the field coils, thus maintaining a constant output voltage. Current limiting is accomplished in the same way. Output current is sensed with a Hall-Effect device that detects the magnetic field created by the output current. When the output current exceeds a preset limit, the field current is turned off. Just as with the voltage regulation, the field current is modulated to maintain a constant output current. Instead of a cut-out relay, DR310 uses a MOSFET ideal diode, which is much more efficient than Schottky diodes. Power is supplied whenever the dynamo output voltage is greater than the battery voltage, rather than a pre-set voltage as in the mechanical regulator. How to polarize a new generator A dynamo uses electromagnets to generate the magnetic field for the armature to rotate in. But when starting up, there is no field current to create this magnetic field. In order to get the process started, some permanent magnetism is required to provide this field. This is provided by iron pole pieces that can be permanently magnetized. A new generator may not have the pole pieces magnetized, so there will be no output, and no field current. Also, a dynamo that has been used with a different polarity (i.e., pos gnd instead of neg gnd) will be polarized backward, and will produce a voltage of the wrong polarity. Magnetizing the pole pieces is easy: While the car is not running, connect a lead from the battery (or B terminal) to the dynamo s field coil (F) terminal for one or two seconds. Connecting them for a long period could overheat and damage the field coils. The pole pieces will now be permanently magnetized, and the dynamo will start up. If the dynamo is properly polarized, it will produce ~3 volts with the field coils disconnected. DR310 Instruction Manual Pg. 8

Troubleshooting In case there is no output from the dynamo, check the following: 1) D terminal is not connected to the dynamo output terminal 2) F terminal is not connected to the dynamo field terminal 3) Dynamo armature is shorted or open 4) Dynamo field coils are shorted or open 5) D, F, or WL are shorted to ground 6) Dynamo is not polarized Service If you need service or have questions, you can contact us at +1 949-598-0700 or support@cloversystems.com. Warranty All Clover Systems products are guaranteed against original defects for two years. Any products returned within the warranty period will be repaired or replaced at no charge except for return shipping. DR310 Instruction Manual Pg. 9