KOLHAPUR FOUNDRY & ENGINEERING CLUSTER

Similar documents
DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

ONE STAGE GAS BURNERS RDBS SERIES

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

RS Series Two Stage Progressive Gas Burners

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

PRESS P/N - P/N ECO SERIES

RS/M SERIES. Modulating Gas Burners FIRING RATES

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

TWO STAGE PROGRESSIVE GAS BURNERS

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

TWO STAGE GAS BURNERS

Emprendimiento Fénix Product Catalogue

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

Oil - kerosene burner

Installation- and maintenance instruction B20KA/K

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

available in battery up to 4 units for a total of 560 kw

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

Installation- and maintenance instruction BENTOFLEX ST 108 PL

RS/E BLU Series. Technical Data Leaflet. Low NOx Modulating Gas Burners. Low NOx Gas TS0087UK00

Installation- and maintenance instruction ST120 S75/21

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

MULTIFIRE. High temperature dual fuel burner

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

Light oil - kerosene burner

Technical description CHP MODULE

Heater Parts. LXi Low NOx. See Detail on next page Zodiac Pool Systems, Inc. Product Catalog. Heater Parts. After. July Before.

Installation- and maintenance instruction BENTOFLEX ST120KAV

Price List 7. Manufacturer of Spray Guns

A SURVEY OF OUR KNOW-HOW : PETROLEUM GLASSWARE VISCOMETER TUBES

Installation- and maintenance instruction BENTOFLEX ST133KA/K

AMOUNT IN Rs After adding percentage above or at par or below In In words figures. ESTIMATED COST (IN Rupees) In figures. In words

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

Environmental/Analytical LabCivil Engineering Lab Equipment

Installation- and maintenance instruction B20KAV/KV

lubrication systems CME Electric pump for oil and soft grease volumetric

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Installation- and maintenance instruction B20K-2

Installation- and maintenance instruction B20KA/K

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

Rheem Spare Parts Manual. Parts List 740 series PC (before 23/6/2010), PC (before 19/7/2010)

Kerosene - oil burner

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

FIREPAK-E21 & FIREPAK-ED21

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

SPARE PARTS MANUAL VAL HEATERS

Rheem Spare Parts Manual /5F Manufactured from 01/06/2014

Doing more for clean environment and energy saving

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

INSTRUCTION MANUAL. Direct Drive Air Compressor 2320, REV A. 1.

Oil, Gas and Dual Fuel Burners

Secondary Coolant 301

Eclipse 2000 Service Parts

Interior Tankless Models

D M S 760 C01 A A 1 1

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

STAINLESS STEEL CONDENSING GENERATOR RANGE RATED. MODEL Heat thermal input 65,5. 62,0 Heat output (80 C/60 C) 14,0

Уверенная модернизация

Horizontal And Vertical Centrifugal Pumps

Installation- and maintenance instruction BENTOFLEX ST133K

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

SOAPP-CT.25 WorkStation 11/1/00. Equipment List Project: Sample Outputs Conceptual Design: Cogen, 1 x 27 MW, NG, Quarterly

Natural Gas Engine E 0836 E 302 Technical Data

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

General In-line four stroke diesel engine with direct injection. Rotation direction, counterclockwise viewed towards flywheel

Installation- and maintenance instruction B80-2/3

[Small diaphragm vacuum pumps]

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

IMMERSION FIRED HOT WATER BOILER

Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar

Cassia Siamia BLOOD BANK REFRIGERATED CENTRIFUGE MP 6000 R. Technical Data (MP 6000 R)

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

COS-8G & COS-8GDS COMBI OVENS BCS-G STEAMER CNV-8G CONVECTION OVEN REPLACEMENT PARTS LIST

JMC 320 GS-N.L. Technical Description. Cogeneration Unit-Container. with Island Operation no special Grid Code

LIST OF ASSETS FOR DISTRIBUTION TRANSFORMERS PROPOSED FOR TENDER SALE SR. NO. 1 No.

50Hz 1500 rev/min 1 / 2 TA Luft* Prime Power. Standby Max

KINEMAX. Medium velocity gas or oil burners

Infrared oil heater. Model. Type. KBE5S for 120V 60Hz KBE5L for 120V 60Hz KBE5L 2-step for 120V 60Hz KBE1S for 230V 50Hz

DR30D, DR30DI Range. 2 Door Assembly. 3 Control Panel Assembly. 4 Upper Cooktop Assembly. 5 Lower Cooktop Assembly. 6 Sub-Panel/Manifold Assembly

Metal tube variable area flowmeter for gases, liquids and steam

PRICE BID - PART: I I

Models. Save This Manual For Future Reference. International Comfort Products Corporation (USA) Lewisburg, TN USA LP1 5/16/

Transcription:

KOLHAPUR FOUNDRY & ENGINEERING CLUSTER With reference to 24 th April 2016 Tender Notice published in Maharashtra Times & Times of India for GSR, Water Tank, Screw Compressor, LPG system, Lab testing equipments etc. the technical specifications are as follow. For more technical assistance you may please contact to Mr. Narendra Patil, GM of Sand Reclamation Plant, GOSHIMA on cell no. + 91 9850007004. Technically Specification for Item A Sintex Water Tanks Storage tank Capacity- 5000 Ltrs-2Nos Over head mounted on office roof, Water piping from over head tank to unit as per attached water piping layout No- KFC02-100-303B along with Water piping DN40 / 1.1/2 & valve, vertical air Vent pipe, drain valve with piping for cleaning etc. Capacity 50,000 Liters Under ground near toilet block, Make up water piping dia.1 from regular Goshima water supply line to storage tank & overhead tanks with float valves in each tanks, Lifting water piping from storage underground tank to overhead tanks by 1 monoblock 1 H.P., 120lpm, 1 BSP connections, suction head 2-3meter with foot valve, suction hose, hose nipple, clamps, discharge head 8-12meter, with cut off starter by low / high sensors in mini control panel including low/high level sensors & its wiring. N0TE: After completion of piping to be measured at an actual on site. Technically Specification for Item B Screw compressor Capacity- 2.57 M3 /Min. / 90-100 CFM Pressure- 6-7 Kg/cm2, Kw / H.P. - Approximate. 15Kw /20H.P, Air cooled, Suitable Air tank along with safety valve, pressure gauge U pipe, With Drain valve with pipe, man hole etc. Exhaust air Duct as per compressor Exhaust port, along with Drawings Air piping: Air piping from compressor to units as per attached air piping-layout No- KFC02-100-302B NOTE: After completion of air piping to be measured at an actual on site. Technically Specification for Item C A) Providing LOT Cylinder Manifold Installation, L.P.G. system along with piping as per attached Layout No- KFC02-100-301B, B) Supplies of LPG in Cylinders, * After completion of Gas piping to be measured at an actual on site. Considering Recommended Diesel Consumption is 50 Litters /Hr. & above data, Please send your offer for the same along with technical details & drawings, running maintenance cost, comparison chart against Diesel. NOTE: After completion of air piping to be measured at an actual on site.

Lab Testing Equipment Technically Specification for Item D Sr. No Equipments Descriptions 01 SAND SIEVER USE: It is use to find out AFS [Fineness No.] of sand Specifications: Motor - 1/8 Hp Single Phase, Cycles 50, Sieve Set as per ISS No 53, 75, 106, 150, 212, 300, 425, 600, 850, 1700 Micron. Dia. 200 mm, OR (Sieves As Per Requirement) Timer 0-15 Min., A ELECTRONIC BALANCE (0.1 gm 1 kg) 03 SAND WASHER USE: It is use to find out clay % of raw sand. Specifications: Motor - 1/20 Hp Single Phase, Cycles 50, Speed Regulator, Timer, Glass Jar, Siphon, Wash Bottle, Sieve - 53 Micron Dia. 100 mm. 04 OVEN 05 HOT PLATE 06 DISTIL WATER PLANT 4 LITRE TYPE: Wall Mount Type Metallic Fitted With Safety with Ejection Type Immersion Heaters, Steam Baffle Is Provided To Take Steam Direct To The Condenser. A Constant Water Level Arrangement Is Also Provided. 07 MOC: Complete Heavy Gauge Stainless SAFETY: Low Water Cut-Off Automatic. HEATING ELEMENT: Immersion Type Heaters MOUNTING: Bracket POWER: 240 V AC ACCESSORIES: Power Cord with Standard 3-Pronge Plug, Bracket, CONNECTING TUBINGS MUFFLE FURNACE Muffle Furnace Rectangular- Specifications:- Max temp - UPTO 1160 0 C, Rating -3.5 K.W, Thermal Fuse for safety & is controlled by digital temp indicator cum controller. Complete with on/off switch, indicators to work on 230V Ac.50H2.Single Phase. Chamber Size- 12 x06 x06 A CRUCIBLE (25 CC) B PAINTING BRUSH C ANALYTICAL BALANCE 0.001 gm TO 200 gm 08 BURETTE STAND A BEAKER 1000ml B CONICAL 250 ml C GLASS ROD

Approval Emissions Electrical data Fuel air data TECHNICAL DATA BURNER Model RLS 190/M MZ Burner operation mode Modulation ratio at max. output Modulating gas side (with regulator and probes accessories) / two stage oil side 2 1 (oil) / 3 1 (gas) Servomotor type SQN 31 run time s 33 Heat output kw 550/1100 2150 Mcal/h 473/946 1849 Working temperature C min./max. 0/40 net calorific value kwh/kg 11,86 Oil viscosity mm 2 /s (cst) 4 6 delivery kg/h 46/93 181 Pump type J7 C delivery kg/h 230 (at 12 bar) Atomised pressure bar 12 Fuel temperature max. C 60 Fuel pre-heater net calorific value kwh/nm 3 10 / G20 density kg/nm3 0,71 gas delivery Nm 3 /h 55/110 215 net calorific value kwh/nm 3 8,6 G25 density kg/nm 3 0,78 gas delivery Nm 3 /h 64/128 250 net calorific value kwh/nm 3 25,8 NO LPG density kg/nm 3 2,02 gas delivery Nm 3 /h -- Fan type Centrifugal with straight blades Air temperature max C 60 Electrical supply Ph/Hz/V 3N/50/230-400~( 10%)3/50/230~( 10%) Auxiliary electrical supply Ph/Hz/V 1/50/230~(10%) Control box type LFL 1.333 Total electrical power kw 6,0 Auxiliary electrical power kw 1,5 Heaters electrical power kw -- Protection level IP 44 Pump motor electrical power kw 0,55 Rated pump motor current A 3,6 Pump motor start up current A 9,5 Pump motor protection level IP 54 Fan motor electrical power kw 4,5 Rated fan motor current A 15,8-9,1 Fan motor start up current A 126-72,8 Fan motor protection level IP 54 type -- Ignition transformer V1 - V2 230V - 2x5 kv I1 - I2 1,9A - 30mA Operation Intermittent (at least one stop every 24 h) Sound pressure db (A) 85 Sound power W -- CO emission mg/kwh < 10 Oil grade of smoke indicator N Bacharach < 2 CxHy emission mg/kwh < 2 NOx emission mg/kwh < 185 G20 CO emission mg/kwh < 10 NOx emission mg/kwh < 120 Directive 73/23-89/336-90/396 EEC Conforming to EN 267 - EN 676 Certification CE - 0085BP0439 Reference conditions: Temperature: 20 C - Pressure: 1013 mbar - Altitude: 100 m a.s.l. - Noise measured at a distance of 1 meter.