Pilot Operated Directional Valves

Similar documents
Directional Controls

Directional Controls

Directional Controls

Pilot Operated Directional Valves

Directional Controls

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Directional Controls

Sepehr Hydraulic Asia

Functional Symbols and Application Notes

Pilot Operated Directional Valves

Directional Controls

Proportional Valves. Proportional Two-Stage Directional Valves

D03 FluiDyne Valves. ENGINEERING DATA

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

Pressure Relief Valves

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Hydraulic Remote Control with STC Port Option Technical Focus

(F*) - DG5V -10- * - (R) - (B) - **(L) - (**) - (X) - (*) - (E) - (T) - (*) - (V)M - (S*) - * ** * * (L) - (*) ** - (***) (EN***)

Directional Control Valves. General Description. Operation. Features

Solenoid Operated Directional Valve

3/2 and 4/2 directional seat valves with solenoid actuation

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

3/2 and 4/2 directional seat valves with solenoid actuation

D05 Directional Control Valves

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Directional Control Valves. Features. Application. Operation

Solenoid Operated Directional Valve

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

Directional Control Valves. General Description. Operation. Features

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Controls

EManually Operated Directional Valves

EManually Operated Directional Valves

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

Directional Control Valves. General Description. Operation. Features

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Monoblock directional control valves DL - Directional control valve

3500 PSI Fixed Displacement Mobile Vane Pumps VQH Series (Supplement to Catalog 353)

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

Proportional Directional Valves with Feedback. K(B)FD/TG4V-5, 12 Series Pressures to 315 bar (4500 psi)

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

High Pressure, High Flow Rate Modular Valves

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Vickers TM Proportional Directional Valves without Feedback. h y d r a u l i c s

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Proportional Valves. Proportional solenoid valves for pressure and flow control

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

Pump Safety Block Model DBA... / DBAW, Series 1X

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description.

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Q max (see specifications table)

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

Directional Control Valves. Application. Features. Operation

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

3/2 and 4/2 directional poppet valve with solenoid actuation

Directional Controls

Proportional Valves. Proportional Directional and Throttle Valves Solenoid Operated

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045. Staffa Fixed Displacement Hydraulic Motor

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Proportional pressure reducing valve, in 3-way version

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

Pilot-Operated Directional Control Valves Series D3 - D11

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

Service Data Vickers. Directional Valves. Wet Armature Solenoid Operated Directional Control Valves DG4V4-01, 1* /EN/0799/S

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Monobloc and Sectional Directional Control Valves

2- and 3-way high-response cartridge valve

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

CONTINENTAL HYDRAULICS VED03MX

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Directional Seat Valve Series D4S (Denison)

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

Monobloc and Sectional Directional Control Valves

Chapter 6: Check Valves

COMPACT CATALOG MONOBLOCK DIRECTIONAL CONTROL VALVES

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

Transcription:

ilot Operated Directional Valves Catalog DG3V-7, 20 Series, ilot Operated DG5V-7, 40 Series, Solenoid Controlled, ilot Operated ISO 440 Size 07

able of Contents DG3V-7 20 Series, ilot Operated Directional Valves DG5V-7 40 Series, Solenoid Controlled ilot Operated Directional Valves Introduction...2 Functional Symbols DG3V-7 ilot Operated Directional Valves...3 DG5V-7 Solenoid Controlled, ilot Operated Models...4 Symbols on Nameplates...5 Spool ypes...5 Model Code...6 Application Notes...7 Operating Data...8 erformance Characteristics...0 Installation Instructions...2 Optional Features...3 Electrical Information...5 Valve for Safety Circuit Applications (35A Spool)...7 Released Assembly Numbers of Valve with Main Spool Monitoring Switch...20 2 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Introduction General Description DG*V-7 valves are used primarily for controlling the starting, stopping and direction of fluid flow. wo series of valves, DG5V solenoid controlled, pilot operated and DG3V pilot operated models are available with a choice of 8 different spools. hese include meter-in and meter-out spools and a regeneration type that can obviate extra valves essential in traditional circuit arrangements. All spools have been designed to provide good low shock, fast response characteristics which can be enhanced by optional stroke and/or pilot choke adjustments. Models include spring offset, spring centered, pressure centered and detented versions. All are available with the option of an integral - port pilot pressure generator. DG5V valves can be arranged for internal or external pilot pressure and/or drain connections. Features and Benefits High pressure and flow capability for maximum cost-effectiveness. Low headloss to minimize power wastage. Low shock characteristics to maximize machine life. Facility to change solenoid coils without disturbing the hydraulic envelope. he many optional features, particularly for DG5V valves, permit matching to virtually every application within the valve s power capacity. Optional mainstage spool position monitoring switch (CE marked) Functional Symbols DG3V-7 ilot Operated Models Comprehensive and simplified symbols. Spring Offset, End-to-End, DG3V-7-*A Spool types: 0, 2, 6, 9, 35, 52, 52, X2, Y2 b X Y B A B A X b a a Spring Centered, DG3V-7-*C Spool types: All Y Spring Offset, End-to-End, Opposite Hand, DG3V-7-*AL Spool types: 0, 2, 6, 9, 52, 52, X2, Y2 b a X Y B A B A X b a Y ressure Centered, DG3V-7-*D Spool types: All DG3V-7 Options he following are shown in a DG3V-7-*C example:. ilot choke module 2. Minimum pilot pressure generator 3. Stroke adjusters at either or at both ends (shown at both ends in example) One or more options can be built into any DG3 series valve. 3 3 2 X Y B A B A X b o a X Y B A B A X Y X L Y B A B A X Y L EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 3

Functional Symbols DG5V-7, Solenoid Controlled, ilot Operated Models Comprehensive and simplified symbols shown configured for external pilot supply and internal drain Spring Offset, End-to-End, DG5V-7-*A Spool types: 0, 2, 6, 9, 35, 52, 52, X2, Y2 X Y B A B A Spring Offset, End-to-End, Opposite Hand, DG5V-7-*AL b a Spool types: 0, 2, 6, 9, 52, 52, X2, Y2 Y X Y B A B A Spring Centered, DG5V-7-*C Spool types: All b a Y a and b interchanged for spool types 4 and 8. X and Y spools require a stroke adjuster at one or both ends, dependent on the application, to limit stroke towards a and/or b. b o a X Y B A B A b a X Y B A B A b a X Y B A A B Y Y Y Spring Offset, End-to-Center Models Spool types DG5V-7-*B 0, 2, 52, 52, X2, Y2 DG5V-7-*BL 4, 8 Spring Offset, End-to-Center, Opposite Hand Models Spool types DG5V-7-*B 4, 8 DG5V-7-*BL 0, 2, 52, 52, X2, Y2 X Y B A A B X Y B A A B b o o a ressure Centered, DG5V-7-*D Spool types: All X L Y B A A B L Y Y Detented, DG5V-7-*N Spool types: 0, 2, 6, 9, 52, 52, X2, Y2 X Y B A A B b a Y Y DG5V-7 Options he following are shown in a DG5V-7-*C example:. ilot choke module 2. Minimum pilot pressure generator 3. Stroke adjusters, at either or at both ends (shown at both ends in example) 4. External pilot connection 5. Internal drain One or more options can be built into any DG5 series valve, the only exception being that the internal drain option is not available with DG5V-7-*D (pressure centered) valves. 3 3 4 2 5 X Y B A A B X 4 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Functional Symbols A B A B L Y B A X Y B A Symbols on Nameplates A ypical illustrations B for: DG3V-7-2D- DG5V-7-3C-2-E--K A B A B 2 4 3 A B X Y B A X L Y B A A B X Y B A Spool ypes Shown in 3-position form, plus 2 transients. 0 2 3 6 9 3 33 & 34 35 52 52 X2 Y2 X33 Y33 a o b 4 8 Notes: a o b. In the detailed and simplified symbols on this and the previous pages, the transient positions are omitted for simplicity. 2. In certain 2-position valves, the o position becomes an additional transient, i.e. in DG5V-7-*A(L) and DG5V-7-*N valves. he performance of the 33 s and 34 spools differ only in the center position. Your Eaton representative can provide further details. Only 35A available. EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 5

Model Codes DG3V-7 20 Series, ilot Operated Directional Valves For pilot operated valves: (F3-) DG3V-7-* ** (-**) (-K)-2* 2 3 4 8 4 For solenoid controlled, pilot operated valves: ( F3-) DG5V-7-* ** (-**) (-**) (-E)(-)(-K) (-*)- (V) M-*****(L) -* 5-4* 2 3 4 5 6 7 8 9 0 2 3 4 Fluid Compatibility Blank = Antiwear hydraulic oil (class L-HM), invert emulsion (class L-HFB), or water glycol (class L-HFC) F3 = As above or phosphate ester (class L-HFD) Note: For further information see Hydraulic Fluids section on page A.2. 2 Spool ype See Functional Symbols section on pages 3-4. 3 Spool Spring Arrangement A = Spring offset, end-toend ( to B when operated) AL = As A but left-hand build ( to A when operated) B = Spring offset, end-tocenter ( to B when operated) BL = As B but left-hand build ( to A when operated) C = Spring centered D = ressure centered N = wo-position detented DG5V option. Same function from DG3V-7-*C valves by alternating pilot supply to one port (X or Y) and permanently draining the other. 4 Spool Control = Stroke adjustment at both ends 2 = ilot choke adjustment both ends 3 = and 2 combined 7 = Stroke adjustment, port A end only 8 = Stroke adjustment, port B end only 27= 2 and 7 combined 28= 2 and 8 combined Omit if not required Not applicable to DG5V-7-*B(L) models. Not applicable to models shown in the Spring offset, end-to-center, opposite hand section on page A.3. Not applicable to models shown in the Spring offset, end-to-center section on page A.3. 5 Main Stage Spool Monitoring Switch (Omit if not required.) CA - Center sensing switch on A port end CB - Center sensing switch on B port end DA - Double offset sensing switch on A port end DB - Double offset sensing switch on B port end CD - Center sensing switch on A port end and double offset sensing switch on B port end A - Offset sensing proximity switch A port end B - Offset sensing proximity swtich B port end D - Offset sensing proximity switch both ends * he spool position monitoring switch shown on this technical document is CE marked and certified and complies to European Standard EN 6000-6-4: 200 (Emissions) for Class A and European Standard EN 6000-6-2: 200 (Immunity). 6 External ilot Supply. DG5V Valve Option Omit for internal pilot supply 7 Internal ilot Drain, DG5V Valve Option Omit for external drain, which is also mandatory for, 4, 8 and 9 spool-type valves 8 Minimum-ilot-ressure Generator ( ort Option) K = 0,35 bar (5 psi) cracking pressure Omit if not required 9 Manual Override Option Blank = lain override in solenoid end(s) only H = Water-resistant manual override on solenoid end(s) Z = No override at either end No override in non-solenoid end of single-solenoid valves. 0 Solenoid Energization Indentity V = Solenoid A is at port A end of pilot valve and/or solenoid B at port B end independent of main-stage valve port locations or spool type; German practice. Omit (except as noted below) for US ANSI B93.9 standard whereby solenoid A is that which, when energized, connects to A in main-stage valve, and/or solenoid B connects to B. Note: Energization identities on valves with type 4 or 8 spools are identical under US and German practices. In such cases the V code is used. Solenoid ype/connection(s) U = ISO 4400 (DIN 43650) mounting FW = /2 N thread junction box FW = /2 N thread junction box and terminal strip FJ = M20 thread junction box FJ = M20 thread junction box and terminal strip FA3W= Junction box with 3-pin male connector to NFA 3.5.29-980 for single-solenoid valves FA5W= Junction box with 5-pin male connector to NFA 3.5.29-980 for single 6 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 or double-solenoid valves Some female plug connector options available separately from Vickers Systems (see lugs for ISO 4400 on page A.6). Others available from electrical stockists. Female connector to be supplied by user. 2 Indicator Lights, Option for Codes FJ, FW, FA3W and FA5W in item 0. L = Lights fitted Omit if lights not required For U-code solenoids use plug with integral light, see page A.6. 3 Coil Rating See Operating Data on page XX for further information. A = 0V AC 50 Hz B = 0V AC 50 Hz/ 20V AC 60 Hz C = 220V AC 50 Hz D = 220V AC 50 Hz/ 240V AC 60 Hz G = 2V DC H = 24V DC For 60 Hz or dual frequency. 4 Design Number 20 series for DG3V valves. 40 series for DG5V valves. Subject to change. Installation dimensions unaltered for design numbers *0 to *9 inclusive. For Mounting Subplate and Fastener Kit Options See Supporting products on page A.0. For ISO 4400 (DIN 43650) Electrical lugs to Suit DG5V---(V)M-U Valves See Installation Dimensions and Electrical lugs and Connectors on page A.3.

Application Notes ilot ressure a. ilot pressure must always exceed tank line pressure by at least the requisite minimum pilot pressure. his also applies when combining opencenter spools (0,, 4, 8, 9 and ) with internal pilot pressure, but they should be used only with externally drained valves. b. Internally drained valves may be used only when surges in the tank line cannot possibly overcome the minimum pilot pressure differential referred to above. When the possibility of pressure surges in the tank line exist, externally drained valves are recommended. c. When DG5V-7-*N valves are de-energized the pilot and main spools remain in the last selected position, provided that pilot pressure is maintained. If pilot pressure fails, or falls below the minimum, the main spool will spring center. Caution: Because of this in-built feature the flow conditions of the center position must be selected with care, for the effect on both the direction of flow and the pilot pressure. Minimum-ilot-ressure Generator Option Can be built into the -port to create a minimum pilot pressure differential of 0,35 bar (5 psi) where internal pilot pressure is required with open-centered spools, i.e. 0,, 4, 8, 9 and. Stroke Adjustment Options hese control the maximum opening of the main spool/body passages by adjusting the limits of spool stroke. By this means, the response time and the pressure drop across the valve for any particular flow rate can be controlled. Stroke adjusters can be fitted at either or both ends of the main-stage valve for adjusting the stroke in one or both directions. One use of stroke adjusters is for controlling the metering characteristics of X* or Y* - type spools. (See model code #4.) ilot Choke Adjustment Options hese provide a meter-out flow control system to the fluid in the pilot chambers of main-stage valves. It allows the velocity of the mainstage spool to be controlled, thereby reducing transient shock condition. For optimum results, a constant reduced pilot pressure is recommended. Control Data, General a. Dependent on the application and the system filtration, any sliding spool valve, if held shifted under pressure for long periods of time, may stick and not move readily due to fluid residue formation. It may therefore need to be cycled periodically to prevent this from happening. b. Surges of fluid in a common drain line serving two or more valves can be of sufficient magnitude to cause inadvertent shifting of the spools. It is recommended that circuit protection be used, such as separate drain lines. c. Control by stroke adjusters, pilot chokes and minimum-pilot-pressure generator options is described on this page. EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 7

Operating Data erformance data typical under standard test conditions which use antiwear hydraulic oil (Class L-HM) at 2 cst (02 SUS) and 50 C (22 F). MAXIMUM RESSURES: DG3V-7 valves; ports:, A, B,, X and Y 350 bar (5000 psi) L 0,5 bar (7 psi) DG5V-7-**(L)(-*)(-E)(-*) valves, (externally drained); ports:, A, B, and X 350 bar (5000 psi) Y 00 bar (500 psi) L 0,5 bar (7 psi) DG5V-7-**(L)(-*)(-E)-(-*) valves, (internally drained)u; ports:, A, B and X 350 bar (5000 psi) 00 bar (500 psi) Available for all except the DG5V-7-D pressure centered models he DG5V, 40 design two-stage valves have been designed to satisfy the needs of most applications. Consult your Eaton representative about an alternative model if: a) Valves are required to remain pressurized for long periods without frequent switching, and /or b) Back pressure on the drain port of externally drained models (or the tank port of internally drained models) is required to rise above 00 bar (500 psi). MAXIMUM FLOW RAES, L/MIN (USGM) A HE MINIMUM ILO RESSURES, AND WIH SOOL YE: See ilot ressures on page XX 70 (000) 40(2000) 20 (3000) 280 (4060) 350 (5000) 0, 2, 3, 6, 3, 33, 52 or 52 300 (80) 300 (80) 300 (80) 300 (80) 300 (80), 4, 9 or 260 (69) 220 (58) 20 (32) 00 (26) 90 (24) 8 300 (80) 300 (80) 250 (66) 65 (44) 40 (37) Higher flow rates possible at higher pilot pressures; consult your local Eaton sales engineer. Consult your local Eaton sales engineer regarding flow limits relative to the regenerative position of type 52 and 52 spools. ilot pressures See ilot ressures on page A.. Control (swept) volume(s), DG3V and main-stage of DG5V valves: Center-to-end 4,07 cm3 (0.25 in3) End-to-end 8,4 cm3 (0.50 in3) Voltage ratings, DG5V valves See 2 in Model Code on page A.7. Voltage limits, DG5V valves: Maximum voltage See emperature limits, on page A.9. Minimum voltage 90% of rated voltage ower consumption, DG5V valves with AC solenoids: Initial VA rms Holding VA rms Single-frequency coils, 50 Hz types A and C 225 39 Dual-frequency coils at 50 Hz, types B and D 265 49 Dual-frequency coils at 60 Hz, types B and D 260 48 ower consumption, DG5V valves with DC solenoids 30W at rated voltage and 20 C (68 F) Relative duty factor, DG5V valves Continuous; ED = 00% ype of protection, DG5V valves: ISO 4400 coils with plug fitted correctly IEC 44 class I65 Junction box IEC 44 class I65 (NEMA 4) Coil winding Class H Lead wires (coil types F**** ) Class H Coil encapsulation Class F 8 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Operating Data ressure drop characteristics See page A.. Response times, DG5V valves: See Response imes section on page A.2. ypical values for a DG5V-7-2C-E spring centered, externally piloted valve under standard test conditions and operating with 50 L/min (40 USgpm) at 350 bar (5000 psi). Coil rating: ilot pressure, bar (psi): Energizing ime, ms De-energizing 0V 50 Hz 5 (28) 20 55 50 (730) 45 55 50 (280) 25 55 20 (3000) 20 55 250 (3600) 8 55 24V DC 5 (28) 30 65 50 (730) 55 65 50 (280 35) 65 20 (3000) 30 65 250 (3600) 28 65 From applying a signal at the solenoid until the main-stage spool completes its travel. In pure switched circuit conditions, devoid of the effects of any suppression diodes and full-wave rectifiers. EMERAURE LIMIS: Fluid temperature limits See page XXX. Ambient temperature limits: See page XXX. Minimum ambient, all valves -20 C (-4 F) Maximum ambients, DG5V valves with coils listed in 2 in Model Code two pages back, and under conditions stated below: Dual-frequency coils: at 50 Hz and 07% of rated voltage 65 C (50 F) at 50 Hz and 0% of rated voltage 65 C (50 F) at 60 Hz and 07% of rated voltage 65 C (50 F) at 60 Hz and 0% of rated voltage 65 C (50 F) Single-frequency (50 Hz) coils at 50 Hz and 65 C (50 F) 0% of rated voltage DC coils at 0% of rated voltage 70 C (58 F) INSALLAION DIMENSIONS: Valves See page XXX Mounting Surface See catalog 2425 Mass (weight), basic models: kg (lb) approx. DG3V-7-*A(L) 0,0 (22.0) DG3V-7-*/*B(L)/*C 7,3 (6.) DG3V-7-*D 8,4 (8.5) DG5V-7-*A/B (AC voltages) 8,4 (8.5) DG5V-7-*A/B (DC voltages) 8,5 (8.7) DG5V-7-*C/N (AC voltages) 8,7 (9.2) DG5V-7-*C/N (DC voltages) 9, (20.0) DG5V-7-*D (AC voltages) 9,8 (2.6) DG5V-7-*D (DC voltages) 0,2 (22.5) Add, kg (2.4 lb) when pilot chock adjustment is fitted. Supporting products: Subplate See catalog 2425 Fastener kits See catalog 234 for available metric bolt kit options, i.e. BKDG7-85898and BKDG7-85899. Installation and start-up (commissioning): Mounting attitudes, DG3V series Optional for models shown. Mounting attitudes, DG5V series Optional for DG5V-7-*B(L)/C/D models, but horizontal mounting is recommended for DG5V-7-*A(L)/N models After-sales service: Spare-parts data for DG3 valves and main stages of DG5 valves, and pilot choke modules Spare-parts data for DG4V-3S pilot stages of DG5 models Consult your local Eaton representative Ask for spares leaflet I-3886-S (minimal text, in English). EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 9

erformance Characteristics ilot ressures Maximum: 350 bar (5000 psi). ypical minimum differential pilot pressure characteristics, shown below, are based on looped flow through to A to B to under standard test conditions. psi 200 bar Min. differential pilot pressure 60 20 80 40 0 2 0 8 6 4 2 0 0 3 2 00 200 300 L/min 20 40 60 80 USgpm Flow rate Spool 0 2 3 4 6 8 9 3 33 52 X* Y* ypes Curve 3 3 2 3 3 3 3 3 ref. Applicable to: Model Spool type Curve correction DG3V-7-*C All As drawn DG3V-7-*D All Add 5 bar (73 psi) DG5V-7-*A(L) 0, 2, 6, 9, 52, X2 &Y2 Subtract 3 bar (44 psi) DG5V-7-*B(L) 0, 2, 6, 52, X2& Y2 As drawn DG5V-7-*C All As drawn DG5V-7-*D All Add 5 bar (73 psi) DG5V-7-*N 0, 2, 6, 9, 52, X2 &Y2 As drawn DG5V-7-52BL models only. ressure Drop Characteristics he following typical pressure drops ( p) at flow rates (Q) are based on standard test conditions, using oil of 0,865 specific gravity. Except where otherwise stated, for any other flow rate (Q ) the pressure drop ( p ) will be approximately p = p (Q /Q) 2. FLOW-DIRECION CURVE REFERENCE SOOL YE A B B A 0 2 2 3 3 2 2 3 4 2 2 2 3 2 3 4 2 2 2 6 6 3 8 2 2 2 5 9 2 3 7 2 3 2 4 3 3 2 33 2 2 35 See page 7 52 2 3 52 3 3 orts A and B plugged. ort A plugged. Selected to A. ort B plugged. Selected to B. 0 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

erformance Characteristics Minimum-ilot-ressure Generator For valves fitted with this option, the to A or B pressure drop derived from the graph on the previous page is increased by 3,5 bar (5 psi) at 50 L/min (3 USgpm). At any other flow rate Q the total pressure drop becomes: a. For pressures in bar and flow rates in L/min: p = (Q /50) 2 b. For pressures in psi and flow rates in USgpm: p = 5(Q /3.2) 2 Hydraulic Fluids Materials and seals used in these valves are compatible with antiwear hydraulic oils, water-glycols, water-in-oil emulsions and non-alkylbased phosphate esters. he extreme operating range is 500 to 3 cst (2270 to 70 SUS) but the recommended running range is 54 to 3 cst (245 to 70 SUS). For further technical information about fluids see echnical Information leaflet B-920 or I-286S. Contamination Control Requirements Recommendations on contamination control methods and the selection of products to control fluid condition are included in Vickers publication 932 or 56, Vickers Guide to Systemic Contamination Control. he book also includes information on the Vickers concept of roactive Maintenance. he following recommendations are based on ISO cleanliness levels at 2 m, 5 m and 5 m. For products in this catalog the recommended levels are: Up to 20 bar (3000 psi) 20/8/5 Above 20 bar (3000 psi) 9/7/4 Fluid emperatures For petroleum oil: Min.......... 20 C ( 4 F) Max.*......+70 C (+58 F) * o obtain optimum service life from both fluid and hydraulic system, 65 C (50 F) normally is the maximum temperature. For other fluids where limits are outside those of petroleum oil, consult fluid manufacturer or Eaton representative. Whatever the actual temperature range, ensure that viscosities stay within those specified under Hydraulic Fluids. EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Installation Dimensions Millimeters (inches) Solenoid Controlled Models with ISO 4400 (DIN 43650) Electrical Connections and ilot Choke DG5V-7 **(L)(-2)(-E)(-)(-K)(-*)-(V)M U example For dimensions A, B, C, D and E see page A.5. For solenoid identification see page A.5. For stroke adjusters see page A.4. 3rd angle projection,6 (0.63) Main port 34. (.34) 0.6 (4.0) Main port 4 holes, Ø0,8 (0.42 dia) through, spotfaced Ø7,0 (0.67 dia). orque bolts to 49-59 Nm (36-43 lbf ft) 7,5 (2.85) 69,8 (2.75) 3 (0.5) min. for plug removal Main port A 50.0 (.97) 22.0 (4.8) C A B Main port B For coil removal: 2 holes, Ø6,5 (0.25 dia) through, spotfaced Ø,0 (0.43 dia). orque bolts to 9-4 Nm (6.6-0.3 lbf ft) AC models: 45 (.8) DC models: 6 (2.4) For plug options see page A.6. 48 (.9) With pilot choke fitted: 222,0 (8.74) Without pilot choke: 82,0 (7.7) 5 (2.0) 40 (.57) 95, (3.74) Locknut A B lain manual override or no manual override; for type H manual override see page A.5. 33,0 (.3) 33,0 (.3) 6 places ilot choke adjusters fitted when Model Code 4 = 2, 3, 27 or 28. o adjust, turn locknut counter-clockwise, then turn screw clockwise to slow down rate of spool travel, or counter-clockwise to increase the rate. Retighten locknut to 25-30 Nm (8-22 lbf ft). D Mounting surface. Sealing rings supplied. E 2 location pins Ø3.0 (0.2 dia.) May vary according to plug source. Alternative plug positions by loosening knurled nut counter-clockwise, turning coil and re-tightening nut. 4,0 (0.6) 46,4 (.83) 92,8 (3.65) 95,2 (3.65) Cable entry can be positioned at 90 either way from position shown, by re-assembling the contact holder into the appropriate position inside the plug connector housing. 2 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Optional Features Solenoid Controlled Models with Stroke Adjusters DG5V-7-***(L)(-2)(-E)(-)(-K)(-*)-(V)M-U example For solenoid identification see page A.5. Stroke adjuster fitted both ends when Model Code 4 = or 3 ilot choke adjusters, when fitted Stroke adjuster fitted this end when Stroke adjuster fitted this end Model Code 4 = 7 or 27 when Model Code 4 = 8 or 28 o adjust: urn locknut counter-clockwise, then Locknut turn screw clockwise to shorten stroke, or counter-clockwise to increase stroke. Re-tighten locknut. 48,0 (.89) max. 48,0 (.89) max. Solenoid Controlled Models with Junction Box having Optional erminal Strip and Indicator Lights DG5V-7-***(L)(-**)(-E)(-)(-K)(-*)-(V)MF**(L) example. For solenoid identification see page A.5. Available also with other options shown above and on previous page. 93 (3.7) Ground connection Ø4,0 (0.6) self-tapping screw 50 (2.0) max. over conduit box cover M20-6H x,5 thread for F()J options, or / 2 N for F()W options, at both ends. Closure plug fitted at one end. For other options see 0 & in Model Code, eight pages back, and under NFA Connector--- and erminal Strip and Lights sections, two pages on. 68,75 (2.7) Ref. Model Code 0: Codes FJ and FW : 2 lead wires for each solenoid, approx. 50 (6.0) long. M3 (#6) terminals provided for customer connection. Codes FJ and FW : Valve supplied with lead wires connected into terminal strip suitable for M3 (#6) terminals provided for customer connection. With pilot choke fitted: 227,0 (8.94) Without pilot choke: 87,0 (7.36) ilot Operated Models with Optional ilot Choke and/or Stroke Adjusters DG3V-7-**(-2)(-**) example For dimensions D and E see page A.5. ilot choke adjusters, when fitted 68 (6.6) Stroke adjuster fitted this end when Model Code 4 = 8 or 28 Stroke adjuster fitted both ends when Model Code 4 = or 3 Stroke adjuster fitted this end when Model Code 4 = 7 or 27 With pilot choke fitted: 60,0 (6.3) Without pilot choke: 20,0 (4.73) 48,0 (.89) max D E 48,0 (.89) max EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 3

Optional Features SOLENOID IDENIFICAION Model Spool types Solenoid identity at: Solenoid identity at: (see also in Model Code on page A.6) Main port A end Main port B end DG5V-7-*A/B(-**)(-E)(-)(-K)(-*)-M All except 4 & 8 B DG5V-7-*A/B(-**)(-E)(-)(-K)(-*)-VM All except 4 & 8 A 4 & 8 only B DG5V-7-*AL/BL(-**)(-E)(-)(-K)(-*)-M All except 4 & 8 A DG5V-7-*AL/BL(-**)(-E)(-)(-K)(-*)-VM All except 4 & 8 B 4 & 8 only A DG5V-7-*C/D/N(-**)(-E)(-)(-K)(-*)-M All except 4 & 8 A B DG5V-7-*C/D/N(-**)(-E)(-)(-K)(-*)-VM All spools B A DIMENSIONS Basic model designation AC models DC models A B C A B C D E DG3V-7-*C 97,0 (3.82) 97,0 (3.82) DG3V-7-*A 97,0 (3.82) 3,0 (5.6) DG3V-7-*A(L) 3,0 (5.6) 97,0 (3.82) DG3V-7-*D DG5V-7-*A 47 (5.8) 57 (6.2) 97,0 (3.82) 97,0 (3.82) DG5V-7-*B DG5V-7-4/8BL DG5V-7-*AL 47 (5.8) 57 (6.2) 97,0 (3.82) 97,0 (3.82) DG5V-7-*BL DG5V-7-4/8B DG5V-7-*C 200 (7.8) 220 (8.7) 97,0 (3.82) 97,0 (3.82) DG5V-7-*N DG5V-7-*D 200 (7.8) 220 (8.7) 3,0 (5.6) 97,0 (3.82) Not types 4 or 8 spools. Water-Resistant Manual Override on Solenoids DG5V-7---M-****(L)-H valves Application: General use where finger operation is required (standard manual overrides can only be operated by using a small tool). Manual actuation must be applied within this diameter: approximately 20 (0.8). Spacer prevents actuation by larger device. 5 (0.6) Dimension A, B or C (See page A.3) Spacer Note: H feature is not field convertible from other models; specify with order. 4 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Electrical Information DG5V-7 with Main Stage Spool Monitoring Switch A, B or D Models (roximity Switch) Millimeters (inches) 58.7 (2.3) 304.2 (.97) A ort Side 33.0 (.30) 02.0 (4.02) M2 hread Connection B ort Side 9.7 (7.55) SECIFICAIONS Supply Voltage (Vs) 0 to 30 Vdc Supply Current (ls) 8 ma at 24 Vdc (plus load current) Supply Over-voltage Rating: 35 Vdc continuous Supply Reverse olarity Rating -35 Vdc (with no shorts) Short Circuit olerance: Continuous short between any two pins High otential est, in to Case: 300 Vdc Electronmagnetic Compatiblity: ISO 7637 arts O and I worst case and Immunity to Radiated Electromagnetic Fields, 0 KHZ to GHZ per SAE J3/25 Sep 95 ins to Case Resistance 50 Megohms Load Dump olerance: 80 Vdc eak, 400 ms Decay, with.5 Ohm Source Impedance Switching Frequency: 0 to 3K Hz Ouput: Open collector N sourcing, normally open Sensing Distance (offset position):.27 ± 0.25 mm (.050 ±.00 ) Hysteresis: 0.25 mm (.00 ) Max. Rise/Fall ime: 6.5/.5 microsec R=820 Ohm, C=20 pf @ 8Vdc Ouput Leakage Current 0µa Max. Output Voltage High: +Vs 2.2 Vdc minimum Output Load Current: 200 ma Max. Operating ressure: 350 bar (5000 psi) Operating emperature: -40 to 0 C Humidity: 0 to 00% Electrical information shown in this window is for offset sensing, roximity Switch "A", "B" or "D" Models Functional Diagram - Spring Offset center condition (ref.) 0 0 -full spool stroke 0 +full spool stroke 0=voltage at pin 4 0.5V min. =voltage at pin 4 (Vs 2.2V) min. IN 4 sensor at "A" port side (if applicable) IN 4 sensor at "B" port side (if applicable).050.000 from full spool stroke typical Output Circuit Wiring Instructions IN ower Supply 0K IN 4 Signal Output IN 3 Common SENSOR IN #4 Signal Connector Detail IN # +24VDC±20% IN #3 Common IN #2 Not Used EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 5

Electrical Information DG5V-7 with Main Stage Spool Monitoring Switch CA, CB, DA, DB, CD Models (LVD style) Millimeters (inches) 220,0 (8.66) 425, (6.73) A ort Side 6,0 (6.34) 46,9 (5.78) M2 hread Connection B ort Side SECIFICAIONS Supply Voltage (Vs) 24VDC +/- 20% (Full Wave Bridge with Capacitor) Reverse olarity rotection Max. 300 V Installed Ripple Voltage 0% Current Consumption 40 ma Approx. Outputs NC Contact ositive Sensing Distance (offset position) 5.85 to 6.5 mm Sensing Distance (from center position) ± 0.35 to 0.65 mm Hysteresis 0.06mm Output Voltage (No Short Circuit rotection) Signal Vs 2.5 V Signal 0 <.8 V Output Current < 400 ma A INU + 20% Environmental rotection I65 (With Mounted lug) Operating emp Range -20 C to +85 C Operating ressure 35 bar (4500 psi) CE Declaration of Conformity No. 00 02 002 9 93 AENION: EMC ONLY ENSURED WHEN USING SCREENED CABLES AND SCREENED LUG CASING! YICAL "CA/CB" OUU (FOR SENSING CENER OSIION) Signal YICAL "DA/DB" OUU (FOR FULL SHIF SENSING) Signal 33,0 (.30) YICAL "CD" OUU (FOR CENER SENSING 'A' OR END, FULL SHIF SENSING 'B' OR END) Signal Signal 0 Signal 0 Signal 0 Signal 0 Signal 0 Signal 0 Full Stroke Switch oint Center Switch oint Full Stroke Signal 0 = Voltage at pin 2/4 <.8V Signal = Voltage at pin 2/4 > (Vs 2.5V) Electrical Schematic and Mating Connector Detail Switch oint Full Stroke Center Full Stroke Switch oint Signal 0 = Voltage at pin 2/4 <.8V Signal = Voltage at pin 2/4 > (Vs 2.5V) Full Stroke Switch oint (Full Shift Sensing) Switch oint (Center Sensing) Center Switch oint (Center Sensing) Switch oint (Full Shift Sensing) Full Stroke Signal 0 = Voltage at pin 2/4 <.8V Signal = Voltage at pin 2/4 > (Vs 2.5V) stab = 24V ±20% = = OSZILAOR = = DEMO- DULAOR OVERLOAD ROECED OUU Input Output Output Ground 4 2 3 R L R L2 R,R 2 = e.g. Coil Resistance of the switch relay >/= 60 OHMS L L = IN #3 Common IN #4 Signal Connector Detail IN #2 Signal IN # +24VDC±20% 6 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Valve for Safety Circuit Application (35A Spool) Main Stage Hydraulic Symbol A B A B C D DG5V with A Switch Option Shown MODEL A B C D LEAKAGE -A FLOW CURVE mm (in) mm (in) mm (in) mm (in) cc/min (in 3 /min) DG5V5-35A 8.5 (4.67) 234.7 (9.24) 262. (0.32) Available upon request Available upon request DG5V7-35A 52. (5.99) 252. (9.92) 286.6 (.28) Available upon request See below DG5V8-35A 5.7 (5.97) 346.0 (3.62) 380.5 (4.98) 56 (9.5) Available upon request DG5V0-35A 230.7 (9.0) 443.4 (7.46) 476.3 (8.8) Available upon request Available upon request DG5V7-35A Flow Curve 500 400 p SI 300 200 -A B- 00 0 0 0 20 30 40 50 60 70 80 Flow GM EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 7

Electrical Information lugs for ISO 4400 (DIN 43650) ype Coil Connection For valves with type U coils he cable entry on these plugs can be repositioned at 90 intervals by reassembly of the contact holder relative to the plug housing. LUGS WIHOU INDICAOR LIGHS art no. Color Use on solenoid coil 70775 Black Sol. B 70776 Gray Sol. A LUGS WIH INDICAOR LIGHS Voltage art no. Gray (sol. A) art no. Black (sol. B) 2-24V 977467 977466 00-25V 977469 977468 200-240V 97747 977470 he cable entry is g., for cable Ø 6-0 mm (0.24 to 0.39 dia). Order separately by part number. NFA Connector 3.5.29-980 Connection details and model type/model code references DG5V-7-***---FA3W(L) and DG5V-7-***---FA5W(L) models he receptacle is a standard three or five-pole connector with shortened leads and terminals added. he five-pole plug has four leads 0,6 mm (4.0 ) long and one of 77,8 mm (7.0 ) length. All wires have US Underwriters Laboratory-recognized nonsolder insulated eyelet terminals. he green wire is used for the ground (earth) connection (No. 8-size screw furnished). Valves are supplied prewired. 7 / 8-6 UN-2A thread 6,0 (0.62) 68,75 (2.7) Warning tag: Electrical power must be disconnected before removing or replacing electrical plug 3-pin connector When fitted in single-solenoid valves, e.g.: DG5V-7-*A(L)(-**)-(V)M-FA3W(L) DG5V-7-*B(L)(-**)-(V)M-FA3W(L) 5-pin connector When fitted in double-solenoid valves, e.g.: DG5V-7-*C(-**)-(V)M-FA5W(L) DG5V-7-*D(-**)-(V)M-FA5W(L) DG5V-7-*N(-**)-(V)M-FA5W(L) -lead (to solenoid B ) 2-lead (to solenoid A ) 5 2 4 3 5-lead (to solenoid B ) 4-lead (to solenoid A ) 3-green lead (ground) 5-pin connector When fitted in single-solenoid valves, e.g.: DG5V-7-*A(L)(-**)-(V)M-FA5W(L) DG5V-7-*B(L)(-**)-(V)M-FA5W(L) -green lead (ground) 3-lead (to solenoid) -lead (to solenoid) 5-lead (to solenoid) 2 3 5 2 4 3 25,4 (.0) hex. 4-lead (capped) 2-lead (to solenoid) 2-lead (capped) 3-green lead (ground) 8 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Electrical Information erminal Strip and Light Options When fitted in solenoid controlled valves DG5V-7-**(L)---F****(L). DG5V-7-**(L)---F****-* DG5V-7-**(L)---F****L-* erminal strip (part number 890345) clips to cover and can be field-fitted Conduit box cover and nameplate complete with sealing gasket and 4 screws Lights M3 x 0,5-6H screws (part number 86006) 2 each end 4 terminal screws M3 x 0,5-6H (part number 02-3355) Connections to solenoid A (or B, according to model type) 28,50 (.2) 30,00 (.8) Connections to solenoid B (or A, according to model type) Rubber gasket Anti-rotation tab ensures correct orientation of cover to junction box 2 lenses in cover. For DC coils the +ve lead(s) must be connected to the terminal(s) marked +. When using 3-wire incoming leads to double solenoid valves (i.e. common neutral) the inner pair of terminals must be linked. 2. For correct light indication of energized solenoid ensure that solenoid leads are correctly connected: light terminals are common with each outer pair of solenoid terminals according to the side with + mark. EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 9

Released Assembly Numbers of Valve with Main Spool Monitoring Switch Size D07/NG6 ASSEMBLY NUMBER MODEL CODE 02-396643 DG5V-7-0A-A--K-M-U-H7-30 02-396644 DG5V-7-0C-D--K-M-U-A6-30 5996907-00 DG5V-7-0C-D--K-M-U-A7-30 599694-00 DG5V-7-2A-CA--M-U-H7-30 599695-00 DG5V-7-2A-CD--M-U-H7-30 599696-00 DG5V-7-2A-DA--M-U-H7-30 599697-00 DG5V-7-2A-A--M-U-H7-30 599698-00 DG5V-7-2A-D--M-U-H7-30 599699-00 DG5V-7-2C-CA--M-U-H7-30 02-362980 DG5V-7-2C-CD--M-U-H7-30 02-362980 DG5V-7-2C-CD--M-U-H7-30 599692-00 DG5V-7-2C-DA--M-U-H7-30 5996922-00 DG5V-7-2C-A--M-U-H7-30 ASSEMBLY NUMBER MODEL CODE 5996923-00 DG5V-7-2C-D--M-U-H7-30 02-39795 DG5V-7-35A-A-E-Z-VM-U-H7-30 5996924-00 DG5V-7-6C-CA--M-U-H7-30 5996925-00 DG5V-7-6C-CD--M-U-H7-30 02-39774 DG5V-7-6C-DA-E-M-U-H7-30 5996926-00 DG5V-7-6C-DA--M-U-H7-30 5996927-00 DG5V-7-6C-A--M-U-H7-30 02-39773 DG5V-7-6C-D-E-M-U-H7-30 5996928-00 DG5V-7-6C-D--M-U-H7-30 20 EAON Vickers ilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007

Eaton 465 Lone Oak Road Eden rairie, MN 55344 USA el: 952 937-9800 Fax: 952 974-7722 www.hydraulics.eaton.com Eaton 20 Rosamond Road Footscray Victoria 30 Australia el: (6) 3 939 8222 Fax: (6) 3 938 574 Eaton Dr.-Reckeweg-Str. D-76532 Baden-Baden Germany el: (49) 722 682-0 Fax: (49) 722 682-788 2007 Eaton Corporation All Rights Reserved rinted in USA Document No. V-VLDI-MC007-E Supercedes GB-2326B March 2007