Access Riser Fits PRO370 and PRO380 Series

Similar documents
2460 / 2472 / Series Simplex Grinder Systems

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Installation Manual. Engineered Pump Systems (EPS) Common Components: Manual Contents:

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

PRE-PLUMBED SEWAGE SYSTEM

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

PUMP VAULT S.T.E.P. SYSTEM

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

BioSTEP Screened Pumping System Installation & Service Manual

XLE100/150 Series Explosion-proof Submersible Sewage Pumps

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

ESE Series Cast Iron Sewage Pumps

ON-SITE WASTEWATER PRODUCTS

Pump Specifications Series. Pre-assembled Duplex Sewage System 30 x 36, 110 Gallon

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

SUBMERSIBLE SUMP PUMPS

HALLMARK INDUSTRIES INC

SUBMERSIBLE SUMP PUMPS

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Artesian2 Owners Manual

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

SUBMERSIBLE MINI-PUMP

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

INSTALLATION MANUAL. CNH 5088, 6088, 7088 and 5130, 6130, 7130

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

INSTALLATION AND OPERATION MANUAL

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

MODEL 5120 Tire Repair Station

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

AEROMOTIVE Part # & ½ L DOHC Return Style Fuel System Kit INSTALLATION INSTRUCTIONS

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Users Manual Certified Series Direct Drive Pump 1-7 LPM

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Pump Specifications 250 Series Submersible Sump / Effluent Pump

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

Owners Manual. LifeGuard Power Lift Model # Rev. 2/1/13

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

ONBOARD AIR HOOKUP KIT

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Xtreme Air Command. Step 1 Prepare the components. Step 2 Select a mounting location. Parts list

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Scale Feeder Manifold Water Filtration System Instruction Manual

LifeGuardLift. LifeGuard Power Lift Model #100287A OWNERS MANUAL. Rev: 2/14/11

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

SHALLOW WELL JET PUMP

Installation Instructions

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ArtesianPro Owners Manual

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL

25 GALLON PORTABLE OIL LIFT

SPECIFICATIONS CONTENTS:

Powerful & Intelligent Submersible Pumps

Product Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

Artesian2 Owners Manual

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

SPECIFICATIONS CONTENTS:

LOUDSPEAKER OWNER'S MANUAL

STAR STOP SHALLOW WELL JET PUMP

StormPro BA Series Sump Pump

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Instruction Manual. Fudge Puppy Display Case

Level One Electric Vehicle Charging Station Wall Mount Product Guide

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

LITERS PER MINUTE GALLONS PER MINUTE

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Installation Precautions. Use Precautions. Specifications

StormPro BCV400 Sewage Ejector Pump

GARDEN HOSE UTILITY PUMP

OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

360 Watt Charge Controller

12 Volt Utility Controller for 4, 6, or 8 Brakes No

PR 20/20. WARNING Buyer/User assumes all responsability for safety and proper use not in accordance with the directions and sately labels.

Transcription:

Installation Manual 7171000D Access Riser Fits PRO370 and PRO380 Series Contents 1.) General Information 2.) Installation 3.) Optional 2 Installation Kits 4.) Typical Installation Diagram 5.) Junction Box Template Part Numbers and Descriptions AR18 AC18 ARC18 IKIT2-115 IKIT2-230 ARCKIT115 ARCKIT230 Riser only Cover only Riser and cover kit 2 installation accessories, 115 volt hook-up 2 installation accessories, 230 volt hook-up Complete kit riser, cover and installation accessories, 115 volt Complete kit riser, cover and installation accessories, 230 volt 7000 Apple Tree Avenue Bergen, NY 14416 Phone: (800) 543-2550 Fax: (585) 494-1839 Website: www.libertypumps.com Copyright 2012 Liberty Pumps Inc. All rights reserved

1. General Information IMPORTANT: This unit is designed to allow a PRO370 or 380 simplex ejector system to be installed up to 18 inches below grade in an outdoor installation. It is not a gas or water tight tank extension that increases the capacity of the basin. The riser provides a convenient underground chamber for the electrical and pipe connections to exit underground and out-of-sight. A green twist-lock cover can be removed to provide access to plumbing connections, valves and the electrical junction box. The riser is sold by itself or as a kit with all the necessary components for a professional installation including elbows, electrical fittings and a junction box. Check with your distributor if you purchased only the riser and would like the optional 2 installation kit. NOTE: Due to size constraints, only 2 discharge installation kits are available. 3 discharge systems may require that some components be mounted outside of the riser. 2. Installation &hgjhjhgj&troubleshootingtroubleshooting&troublesh 1. Install the PRO370 or PRO380 sewage system per the instructions included with it. Determine the overall height of the system and riser when excavating and setting the basin. The cover of the access riser should be at ground level when backfilling is complete. Burial depth of the system should not exceed 18 below finished grade. Determine the discharge, electrical, and vent positions relative to the system. The access riser slides over the PRO370/380 tank and can be rotated in any direction to simplify plumbing. The riser will rest on the concrete splash lip of the basin. 2. Installation of sidewall pipe seal grommets. Once exit positions have been determined for both the vent and discharge, a 2 pipe seal grommet can be installed by drilling a 3 hole in the sidewall of the riser. The riser has four flat areas as well as a large ring that runs around the riser to which the discharge pipe or vent can exit. If both a check and ball valve are required, the discharge needs to exit on the opposite side as illustrated on page 4. To ease installation of the pipe through the pipe seal grommet, grease the pipe or use liquid soap as a lubricant. 3. Install the discharge. A short pipe can be threaded into the discharge port of the PRO-Series cover and a 90 elbow attached. A check valve is recommended to prevent water from back flowing and filling the basin. NOTE: In northern climates where frost may be a concern, pipes exiting from the side of the system may be exposed to freezing conditions. If this unit is installed in a frost zone, do not use a check valve. Substitute a union to facilitate cover removal and pump access. If a check valve is not used, the vertical lift should be minimized to reduce the amount of back flow after each cycle. A maximum length of 30 of 2 pipe can be pitched to drain back into the system. Beyond 30, discharge piping should be pitched down towards the final discharge destination. A ball valve is recommended so that back flow can be prevented in the event that the pump or check valve must be removed for service. When connecting the check valve, ball valve, etc. take care to position items as close to the sidewall of the riser as possible to allow room for removal of the system cover. Use unions and couplings as necessary to allow for this. 4. Connection of vent. To maintain hidden pipes, the vent pipe can be routed underground to an existing household vent. For a 2 vent, a 3 hole should be drilled in the sidewall of the riser where the vent pipe is to exit. Install the pipe seal grommet, which is included in the kit. The pipe should be lubricated with liquid soap or grease to ease pipe installation. A 90 elbow with male threads should be threaded into the vent flange of the system. A rubber slip coupler is provided and should be installed in the vent piping as illustrated on page 4 to allow easy removal of the system cover and pump if service is required. 5. Connection of electrical. A NEMA 4X weatherproof pump station junction box (Liberty model JB120 or JB230) is recommended. It can be mounted inside or outside of the access riser. If mounting inside, a template is included in this manual to drill the four mounting holes. If nonmetallic conduit is used it must be mounted in such a fashion as to be at least 18 inches below grade. Consult the National Electrical Code (NEC) and local codes for further information. Additional instructions are included with the JB120 or JB230 box. A qualified electrician should perform all electrical connections. Copyright 2012 Liberty Pumps Inc. All rights reserved - 2 -

6. Backfilling. Use only fine, 1/8" to 3/4" pea gravel or 1/8" to 1/2" washed, crushed stone as backfill around the access riser. Do not use sand or native soil as backfill. Tamp backfill lightly. Avoid running heavy equipment next to the riser. A light layer of topsoil can be used at cover level. 7. Installation of cover. The cover features a twist-lock design and 4 stainless steel screws to secure it. When installing the cover, line up the four tabs with the four receptacles and locking tongue which fits into a cut recess in the under side of the cover. Push down and rotate the cover in a clockwise direction until the tongue bottoms in the slot. Install the four stainless steel bolts to secure the cover. A padlock can be placed through a hole in the tongue to deter unwanted entry. The cover is designed to handle light traffic loads such as walking or light lawn and garden equipment. DO NOT RUN HEAVY TRACTORS OR OTHER EQUIPMENT OVER THE COVER. MAXIMUM LOAD RATING IS 250 LBS. 3. Optional 2 Installation Kits Kit Number IKIT2-115 IKIT2-230 Description Installation accessories Kit, 2 discharge, 115V wiring box Installation accessories Kit, 2 discharge, 230V wiring box (1-phase) Liberty risers are sold independently or as a kit with all of the necessary installation accessories. If your riser did not include the installation kit, contact your distributor for pricing and availability or call the factory at 1-800-543-2550. See Liberty PRO-series literature for complete information on installation kits. *Installation kits include: Full flow 2 union-type check valve PVC Ball Valve (2) 90 degree PVC elbows (2) 2 rubber pipe seal grommets (2) SCH 80 PVC toe nipple ( Threaded pipe) 2 rubber coupler with clamps Model JB120 or JB230 pump station wiring box with: Terminal strip with separate alarm and pump control circuit Receptacle for pump (115 volt or 230 volt depending on model) Riser extension coupling and washers Custom-engineered liquid tight cable seal for pump, switch and alarm cords Electrical conduit hub *Please note that installation kits do not include Schedule 40 PVC pipe. JB120 or 230 Pump Station Wiring Box (NEMA 4X) Copyright 2012 Liberty Pumps Inc. All rights reserved - 3 -

4. Typical Installation Diagram (PRO380 shown) PP(ProInstalla&hgjhjhgj&TroubleshootingTroubleshooting Installation components from IKIT2-115 or IKIT2-230 shown. Liberty installation kits are available in 2 only. Due to size constraints, certain component of 3 discharge systems may need to be mounted outside of the riser. 5. 3 Year Limited Warranty Liberty Pumps, Inc. warrants that pumps of its manufacture are free from all factory defects in material and workmanship for a period of 3 years from the date of purchase. The date of purchase shall be determined by a dated sales receipt noting the model and serial number of the pump. The dated sales receipt must accompany the returned pump if the date of return is more than 3 years from the "CODE" (date of manufacture) number noted on the pump nameplate. The manufacturer's obligation under this Warranty shall be limited to the repair or replacement of any parts found by the manufacturer to be defective, provided the part or assembly is returned freight prepaid to the manufacturer or its authorized service center, and provided that none of the following warranty-voiding characteristics are evident. The manufacturer shall not be liable under this Warranty if the product has not been properly installed; if it has been disassembled, modified, abused or tampered with; if the electrical cord has been cut, damaged or spliced; if the pump discharge has been reduced in size; if the pump has been used in water temperatures above the advertised rating, or water containing sand, lime, cement, gravel or other abrasives; if the product has been used to pump chemicals or hydrocarbons; if a non-submersible motor has been subjected to excessive moisture; or if the label bearing the serial, model and code number has been removed. Liberty Pumps, Inc. shall not be liable for any loss, damage or expenses resulting from installation or use of its products, or for consequential damages, including costs of removal, reinstallation or transportation. There is no other express warranty. All implied warranties, including those of merchantability and fitness for a particular purpose, are limited to three years from the date of purchase. This Warranty contains the exclusive remedy of the purchaser, and, where permitted, liability for consequential or incidental damages under any and all warranties are excluded. Copyright 2012 Liberty Pumps Inc. All rights reserved - 4 -

6. Junction Box Template Copyright 2012 Liberty Pumps Inc. All rights reserved - 5 -