430 PHOENIX CONTACT Courtesy of Steven Engineering, Inc. - (800)

Insertion / withdrawal force. Rated current See page 20 and 22. Rated voltage See page 20 and 22. Contact resistance. Insulation resistance

AMPHENOL PCD SHENZHEN. EXCEL MATE CC (Charging Coupler)

AMPHENOL PCD SHENZHEN. EXCEL MATE CC (Charging Coupler)

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

Charging cables mode 3 case B

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION. General details: Main circuit: Product brand name. Size of the contactor

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Servo solenoid valves with on-board electronics (OBE)

Essential equipment for all your requirements

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Electronic Limit Switch Type

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Servo solenoid valves with on-board electronics (OBE)

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

2-way proportional throttle valve for block installation

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

JUMO ecotrans Lf 01/02

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

CMK Metallized polycarbonate CECC approval, detail specification According to CECC 30500, IEC 384-6

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Intelligent Positioner

Pilot-Operated Directional Control Valves Series D3 - D11

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

AZM 161SK 12/12RKED/TU 024

Thermal Overcurrent Circuit Breaker 3120-F...

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Power Panel 6 W Potentiometer

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Temperature sensor type T.3., Construction type 3, plug-in sensor for protection tube with lateral cable outlet (Pt100/Pt1000, NTC)

Thermal Circuit Breaker 3120-F...

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Emergency lighting units EM powerled

SMD High Power Precision Resistors

High-voltage high-breaking capacity VV fuse-links

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Temperature sensors. Fluidcontrol

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

3NP1 Fuse Switch Disconnectors up to 630 A

Paddle-wheel flow controller for On/Off control

DC/DC converters - MINI-PS DC/ 5-15DC/

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

8710 EN. Potentiometric Displacement Sensors. Models 8710, 8711

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

Plug-in relays Mini ISO relays

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

Moving Coil Indicators with direct temperature sensor input

Emergency lighting units EM powerled

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

EV Charge Control Standard-compliant control of the Control Pilot and Proximity Plug interfaces between the electric vehicle and charging station

INSERTION flow sensor for continuous flow measurement

In-line Plug-in Design 3NJ6

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure relief valve

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Platinum-chip Temperature Sensors in SMD Design Type According to DIN EN 60751

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

According to IEC , grade 1.1

Proportional pressure reducing valve, pilot operated

Safety door-handle system STS

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Directional Control Valve Series 4D01 (DENISON)

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Servo solenoid valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

Thermal Overcurrent Circuit Breaker 3130

Proportional pressure relief valve, pilot operated

Servo solenoid valves with positive overlap and on-board electronics

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Technical Datasheet P-30/P-31. Standard transmitter.

HM...TC-R. Turbine Flow Meters for Solvents and Di-Water. Technical Datasheet

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Radial Aluminium Electrolytic Capacitors 105 C

Industrial Hydraulics FAQs

Directional Controls

Thermal Overcurrent Circuit Breaker 3130

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

K12 High Performance Key Switches

Proportional pressure reducing valve, pilot operated, with inductive position transducer

PERFORMANCE IP67 (IEC60529, JIS C 0920) Silver contact: Max.50 mω (6 to 8 Vdc, energizing current 1A, measured by voltage drop method) Gold alloy cros

BETA Switching Switches and Light Indicators

Automotive Grade Thin Film Chip Resistors

Proportional pressure reducing valve, pilot operated

Transcription:

Vehicle Inlet for charging with alternating current (AC) and direct current (DC), for installation in electric vehicles (EV), CCS type 2, Combined Charging System, IEC 62196-3, 125 A / 850 V (DC), 20 A / 250 V (AC), 12 V Locking actuator, length: 2 m, Front and rear mounting, This product cannot be ordered online. Should you have any questions, please contact our sales team at PHOENIX CONTACT E-Mobility GmbH, emobility@phoenixcontact.com, phone: + 49 5235 3-43890. Article description Vehicle Inlet for charging with alternating current (AC) and direct current (DC), compatible with type 2 AC and CCS Vehicle Connectors (EVSE), for installation in electric vehicles for E-Mobility (EV). This product cannot be ordered online. Should you have any questions, please contact our sales team at PHOENIX CONTACT E-Mobility GmbH, emobility@phoenixcontact.com, phone: + 49 5235 3-43890. Your advantages Uniform, space-saving dimensions for the installation space and the screw connection points of all Phoenix Contact Vehicle Inlets Silver-plated surface of the power and signal contacts Certified in accordance with IATF 16949:2016 and ISO 9001:2015 Material data available in the IMDS (International Material Data System of the automotive industry) Tested in accordance with selected tests of automotive standards LV124, LV214, LV215-2 Manual emergency release of the locking actuator Integrated interlock during charging Integrated temperature sensors for monitoring the temperature at the power contacts Key commercial data package_quantity 1 GTIN 4055626240558 Technical data Product definition Product type Standards/regulations IEC 62196-3 Charging standard CCS type 2 Charging mode Mode 2, 3, 4 Note Note on the connection method Vehicle Inlet for charging with alternating current (AC) and direct current (DC), for installation in electric vehicles (EV) Combined Charging System This product cannot be ordered online. Should you have any questions, please contact our sales team at PHOENIX CONTACT E-Mobility GmbH, emobility@phoenixcontact.com, phone: + 49 5235 3-43890. A protective cap is supplied as standard for the DC contacts. Crimp connection, cannot be disconnected May 29, 2018 1 / 11

Technical data Dimensions Height Width Depth Bore dimensions Conductor length Cable structure 130.4 mm 111 mm 107.4 mm 94.8 mm x 82.4 mm, 94.8 mm x 111.0 mm 2 m (AC cables) 2 m (DC cables) 2 m (Locking actuator cables) 2 m (PE cable) 1.8 m (Temperature sensors cables) 2 m (Communications cables) 2 x 35 mm² + 1 x 25 mm² + 2 x 2.5 mm² + 3 x 2 x 0.5 mm² Ambient conditions Ambient temperature (operation) -30 C... 50 C Ambient temperature (storage/transport) -40 C... 80 C Max. altitude Degree of protection Electrical properties Maximum charging power Type of charging current Number of phases 1 Number of power contacts Rated current of power contacts Rated voltage for power contacts Number of signal contacts Rated current for signal contacts Rated voltage for signal contacts Type of signal transmission Insulation resistance of neighboring contacts Resistor coding 5000 m (above sea level) IP55 (plugged in) IP55 (with protective cap) 125 kw DC, AC 1-phase 5 (L1, N, PE, DC+, DC-) 125 A DC 20 A AC 250 V AC 850 V DC 2 (CP, PP) 2 A 30 V AC Pulse width modulation with modulated Powerline communication according to ISO/IEC 15118 / DIN SPEC 70121 > 5 MΩ 4.7 kω (between PE and PP) Temperature measurement DC contacts: Pt 1000 (DIN EN 60751) Temperature monitoring AC contacts: PTC chain (DIN EN 60738-1) Mechanical properties Insertion/withdrawal cycles > 10000 Insertion force Withdrawal force < 100 N < 100 N May 29, 2018 2 / 11

Technical data Mounting Possible mounting positions Restrictions to mounting position Mounting position of the locking actuator Mounting hole diameter Front and rear mounting Only 0 to 90 degree frontal inclination possible, see figure Right-side 6.80 mm (ø) Design Design line Generation 2 Housing color black Customer variations On request Material Material Material surface of contacts Plastic Ag Locking Locking type Locking voltage Locking detection Mechanical emergency release Locking in the inserted state with a locking mechanism 12 V available available Locking actuator Typical power supply at the motor Possible power supply range at the motor Max. dwell time with reverse current Recommended adaptation time Pause time after entry or exit path Maximum voltage for locking detection Service life 12 V 9 V... 16 V 1000 ms 600 ms 3 s 30 V > 100000 load cycles Ambient temperature (operation) -30 C... 50 C Length of cable Temperature sensors Type of sensor Pt 1000 Standards/regulations DIN EN 60751 Recommended measured current Tolerance at the sensor with the recommended measured current 2 m 1 ma (1 V at 0 C) Temperature range -50 C... 130 C Temperature coefficient (TCR) Long-term stability (max. R0-Drift) Shutdown temperature ±1K 3850 ppm/k 0.06 % (After 1000 hours at 130 C) 90 C equivalent to a Pt 1000 value of 1346.5 Ω May 29, 2018 3 / 11

Technical data Temperature monitoring Type of sensor PTC chain Standards/regulations DIN EN 60738-1 Recommended measured current < 1 ma Maximum permitted power dissipation 20 mw Temperature range -40 C... 125 C Resistance range 200 Ω... 2200 Ω Switch-off threshold 1500.00 Ω Diagnostic capability Short circuit, cable break Accessories DC charging cable EV-T2M4CC-DC125A-5,0M50ESBK00-1409060 DC charging cable with vehicle connector, open cable end, CCS type 2, Combined Charging System, IEC 62196-3, 125 A / 1000 V (DC), design line Standard, cable: 5 m, black, straight, mating face: black, handle area: gray AC charging cable EV-T2M3PC-1AC20A-5,0M2,5ESBK00-1622118 Mobile AC charging cable with vehicle connector and infrastructure plug, with protective cap, Type 2, IEC 62196-2, 20 A / 250 V (AC), design line D-Line, cable: 5 m, black, straight, mating face: gray, handle area: gray EV-T2G3PC-1AC20A-5,0M2,5ESBK01-1627982 Mobile AC charging cable with vehicle connector and infrastructure plug, with protective cap, Type 2, IEC 62196-2, 20 A / 250 V (AC), design line C-Line, cable: 5 m, black, straight, mating face: black, handle area: gray Drawings May 29, 2018 4 / 11

Diagram Drawings Locking states of the locking actuator May 29, 2018 5 / 11

Diagram Drawings PTC characteristic curve at an ambient temperature of 25 C for temperature monitoring at the AC contacts May 29, 2018 6 / 11

Diagram Pt 1000 characteristic curve at an ambient temperature of 25 C for temperature measurement at the DC contacts Connection diagram Pin assignment of Vehicle Inlet Dimensional drawing Dimensional drawing May 29, 2018 7 / 11

The Combined Charging System (CCS) principle - standard-compliant charging system for electric vehicles, which supports both conventional AC charging and fast DC charging. Both Vehicle Connectors fit into the CCS Vehicle Inlet. May 29, 2018 8 / 11

Operating instructions Detection for Vehicle Connector May 29, 2018 9 / 11

Installation positions Emergency unlocking of the 12 V locking actuator May 29, 2018 10 / 11

Phoenix Contact 2017 - all rights reserved http://www.phoenixcontact.com Block diagram of the locking actuator May 29, 2018 11 / 11