EX Series. Electric Actuators for Ball and Butterfly Valves

Similar documents
EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves

Electric Actuator Driven Compact Ball Valves

Actuator Driven Compact Ball Valves

Actuator Driven Compact Ball Valves

Two neck designs for your choice : Easy valve-to-flange centering : Wide range of service applications : Stabilized operating torque :

E-232=04 PROVIDED BY: PT. SINAR MAS SAKTI

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

DJ Series Butterfly Valves

Standard Product Range

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd.

AE Installation Operation & Maintenance Instructions

Installation, Maintenance and Operation Manual

26 Series Stainless Steel 2-way Ball Valves

E Series Electric Actuators

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

HS1C Interlock Switches with Solenoid

VALVES WITH NA ELECTRIC ACTUATOR

VALVES WITH SA ELECTRIC ACTUATOR

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

SG-B1 SERIES / SG-A1 SERIES

Direct Coupled Damper Actuator Model MY6050A1001

HS5E Miniature Interlock Switches with Solenoid

Direct Coupled Damper Actuator Model MY9050A1001

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

VALVES WITH UM ELECTRIC ACTUATOR

Quarter Master Chief Series 92 Actuator

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

Performance. Type NA006 NA009 NA015 NA019 NA028 NA038 NA050 NA060 NA080 NA100 NA150 NA200 NA250

Operation Manual For KITZ B Series Pneumatic Valve Actuators

VALVES WITH SA03 ELECTRIC ACTUATOR

The Belimo Butterfly Valves

Linear Valve Electric Actuator

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

MAQ Series Electric Actuator

ELECTRONIC CONTROL ACTUATOR

HS1C-P Interlock Plug Unit with Door Lock

Surepowr Series Sure 150

VALVES WITH UV ELECTRIC ACTUATOR

ELECTRONIC CONTROL ACTUATOR

VALVE WITH SA ELECTRIC ACTUATOR

PD3/PDV3-20A/25A/40A Series

ELECTRONIC CONTROL ACTUATOR

POWER REGULATOR LD -40PSU

Installation, Operation and Maintenance Manual

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe

Installation and Operating Manual

Surepowr Series 100 Installation Manual

ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

EW 350 ELECTRIC ACTUATOR INSTALLATION, MAINTENANCE AND OPERATION MANUAL

Motorized Two-Way Ball Valve with Screwed-End Connection

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A)

Motorized Butterfly Valve

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Series Village Lane Easley, SC Ph: (864) Fax: (864) Worm and Spur Gear Electric Actuators

BUTTERFLY VALVES + NA ELECTRIC ACTUATOR

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

RS ACTUATO RS ACTUATO

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Series Electric Actuators

Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve. Steam Solenoid Valve. 1 of 32

Vacuum pump system type

HN B G1/US B G2/US B G3

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

25% reduction in volume * PB1013A/Air-operated type without foot

Mounting and Operating Instructions EB 5868/5869 EN

TURQUOISE STROKE SWITCHES

F6300L, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Ready for outdoor use too!

Quarter Master Series 94 Actuator

Series ISA. Air Catch Sensor. For Detection of Work Presence

Door Interlock Switches

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

High Pressure Coolant Valve

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Compact electric actuators for 90 operation of 1/4 turn valves providing a range of torque outputs up to 1645 Nm.

V4(V7)-ABFW-EPN16 Actuated Wafer type butterfly valves

Motorized Butterfly Valve Actuated Wafer type butterfly valves

VALVE WITH UV ELECTRIC ACTUATOR

3-Way Ball Valve Type 23 Electric Actuated Type T

Motorized Butterfly Valve

AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems

HS6B Series Subminiature Interlock Switch

Pressure sensor with built-in amplification and temperature compensation circuit

HS1L Interlock Switches with Solenoid

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Transcription:

EX Series Electric Actuators for Ball and Butterfly Valves

Next Generation Electrical Actuator Realization of Upgraded General-Purpose Actuators The modularization and the adoption of common parts have brought significant advantage to EXS and EXH series, such as: Better Cost Performance Compared with other equivalent actuators, EXS and EXH are superior in specification and performance. Instant Option Availability EXS and EXH can be used for various applications just by instant replacement of the modules of parts and exchangeable extension circuit boards. Improvement of Operability and Maintenance Easiness In addition to modulation and adoption of common parts, the highly visible position indicator and manual handle also contribute to speedy maintenance. Manual Override An actuator can be manually operated by the easy-to-use round handle. Auxiliary hexagonal wrenches will make operation easier. Position Indicator The actuators come with the highly visible position indicator with a transparent cover as standard. 4 5 EXH: High speed actuator for ball valves. 4 Precision Adjustable Cam / Standard Auxiliary Limit Switch Cams are adjustable to precise position. Two auxiliary limit switches, in addition to two standard limit switches, are provided, which can be used for output signal with the voltage that users select. Two more auxiliary limit switches or a potentiometer can be added as an option. Special limit switches are available for extremely small ampere. (50mA or smaller) Interlock Switch The Interlock switch will cut off power supply by being pulled it up, which will ensure safe manual operation. The manual mode can be indicated by output signal. 4 5 Steel Exterior Bolting All bolts used outside the actuator are made of stainless steel. Combined with the adoption of the fall-off-proof bolts, the actuator features high durability and reliability suitable for long service. 5 EXS: Standard speed actuator for ball valves and butterfly valves. Adoption of Planetary Gear A planetary gear is used in the output reduction gear system, which enables to achieve high reduction ratio with compact design.

The adoption of common parts and part modularization have enabled flexible modification, which will widen the applications of the actuator. Various capacitors for different f voltages Circuit board Extension circuit board Limit switch unit with the potentiometer Terminal box Optional specification Power supply AC0V 50/0Hz AC5V 50/0Hz AC0V 0Hz AC0V 50/0Hz AC0V 50/0Hz AC40V 50Hz AC5V 50Hz, AC0V 0Hz, AC0V 0Hz, AC40V EXH EXS Allowable fluctuation of supply voltage is limited within between minus 0% and plus 5% for 50Hz. Relays EXH EXS Relays (on/off by a-contact) can be provided in the actuator by using extension circuit boards Limit switch specification Contact for Micro load (Minute electrical current) EXH EXS Two standard limit switches can be replaced by optional limit switches for micro load (minute electrical current) Potentio-meter output EXH 5Ω (Coil type) 500Ω (Coil type) The valve opening degree is indicated by resistance value. EXS Auxiliary limit switch specification Two more additional limit switches can be added. Switches for micro load application are also available. Including four standard limit switches, total six switches can be used. ( In case the potentionmeter is used, four limit switches in total can be used at maximum.) Terminal box EXH G/ two conduit ports G/4 one conduit port NPT/ two conduit ports NPT/4 one conduit port M0 one conduit port Terminal box with two G/ conduit port is equipped as standard for EXS type. For EXH type, the use of the terminal box will enable the actuator to connect cables without removing the cover and to extend the actuator functions by using optional circuit boards. Conduit port G/4, NPT/, NPT/4, M0 EXH EXH EXS EXS

Specification High-speed type For ball valve Standard-speed type For butterfly valve and ball valve Power Supply EXH00/00- EXH00/00- EXS00/00- EXH00/00- EXS00/00-00/00V AC ±0% 50/0Hz EXH00/00-4 EXS00/00-4 EXH00/00-5 EXS00/00-5 Output Torque (Nm) 9.8 49 9 588 000 Rated Current (A) * 00V AC 0.5 0.5..8.8 Motor Type 00V AC 0.5 0.5 0..5.5 Reversible Motor Output (W) (Rating) 85 85 Rotating Direction * Tuning clockwise to close and counterclockwise to open valves Duty Factor [%ED] 0 0 0 0 0 Valve Closing Time [SEC] * EXH 50Hz 9 4 8 49 EXH 0Hz 8 7 4 EXS 50Hz 5 5 49 49 EXS 0Hz 0 4 4 Space Heater Volume [W] 00V AC 5 5 5 5 5 Position Limit Switch* 4 Switch Contact Voltage Insulation Class Overload Protection Service Environment Water, Dust Proof Ambient Temperature 00V AC 5 5 5 5 5 Two switches with voltage and two without voltage supplied 50V AC A least resistance load JIS Class E, Strength: 500V AC min. or 800V sec., Resistance: 00Ω minimum at 500V DC Thermal protection Indoor / Outdoor (Submergence and direct sunlight must be avoided.) Equivalent to IP-7-0 C ~ +50 C Conduit Port EXH One G/ Mounting Position EXS Two G/ From Vertical position to Horizontal position (No downward position) Manual Operation Pull up the manual override handle knob for manual operation, which will activate the built-in interlock switch to cut off power supply. For the restoration of electrical operation, push down the handle knob Mechanical Stopper EXH Mechanical stoppers are equipped in open and closed position. The stoppers are adjustable by 7 degrees in the both positions EXS Mechanical stoppers, which can be adjusted in the closed position, are equipped in open and closed position Position Indicator Position indicator, covered by transparent cover, is equipped on the top of the actuator cover Mounting Flange In accordance with ISO5 * As the actuator is subjected to approx. tenfold rated current at startup, the contacts of electrical devices connected to the actuator must have enough capacity to handle this large electrical current. * Refer to Operation manual for way valves. * Valve closing time is calculated based on an unloaded condition without the valve being mounted. The closing time will be 0% slower, when the valve is mounted. *4 In case load current is 50 ma or smaller, use limit switches for micro load (minute current). Circuit Diagram Product Code AC Power supply 00/00V 50/0Hz Scope of supply Switch 0/0V 50/0Hz 5V 0Hz 0V 50Hz (4) Load Choose the desired voltage (Close) (Open) FG 7 Space heater 5 () 4 () COM () SLS COM () OLS COM Interlock Switch () M4 set screw (for grounding) Capacitor Motor () (4) COM SLS () (4) COM OLS () () 5 () 4 () () 0 9 8 EX Series Product Code EX Actuator size EXS: 4 5 EXH: 4 5 Power supply 00 : AC00V 00 : AC00V Type EXS: Standard speed actuator for ball valves and butterfly valves. EXH: High speed actuator for ball valves. Action of Interlock Switch The handle knob is pulled up for manual operation. COM The handle knob is pushed down for electrical operation. COM Note () Limit switches activate OLS: on full open position SLS : on full closed position OLS : on full open position for transmission of signal with micro load current SLS : on full closed position for transmission of signal with micro load current () Thermal protector built-in motor () The motor and space heater will be de-energized, when the actuator is manually operated or the actuator cover is removed. (4) Allowable load for limit switch contact: AC50V A (Resistance load). Use special limit switches for micro load application. (5) The above circuit diagram indicates the pattern of full open position for two way ball valves or butterfly valves. () Pin number 4, 5 and to 5 are extra terminals.

Dimensions Type EXH W EXH00/00-5 Space for removing a cover t l E D4 E E Position of handle on manual operation mode. E5 H Ground H t H H4 G with conduit plug H5 D5 E EXH00/00-4 EXH00/00- D EXH00/00-, D Type E E E E 4 E 5 E W H H H H 4 H 5 D D D D 4 D 5 l t t EXH00/00-9 54 0.4.5 99.5 8.5 8 7 0 07.5 50 70 5 40 EXH00/00-9 54 0.4.5 99.5 8.5 8 7 0 07.5 50 70 5 40 EXH00/00-5 9 45. 4 8.5 58 0.5 44 9 0 7.5 50 70 0 55 0 5 EXH00/00-4 8 7 5. 50 8.5 8.5 88 7 78 5 0 5 70 0 5 55 0 4 EXH00/00-5 8 7 5. 50 8.5 8.5 88 57 59 4 0 5 40 00 0 5 unit: mm Type EXS W E4 E E E Position of handle on manual operation mode. H H H5 W H D5 Space for removing a cover EXS00/00-5 EXS00/00-4 H Ground EXS00/00- D D H H4 H H4 t t l D4 E5 E EXS00/00- In case of EXS-4 G with conduit plug Type E E E E 4 E 5 E W W H H H H 4 H 5 H D D D D 4 D 5 l t t EXS00/00-0.5 54 0.4.5 98 40 8 04 7 0 07.5 50 70 5 40 EXS00/00-0 9 45. 4.5 40 58 0.5.5 44 0 7.5 50 70 0 55 0 5 EXS00/00-4 45.5 7 5. 50 7 40 88 7 58 78 8 0 5 70 0 5 55 0 4 EXS00/00-5 45.5 7 5. 50 7 40 88 57 58 59 99 0 5 40 00 0 5 unit: mm 4

Actuator Sizing Sizing condition: Ball valve Service condition Fluid Clean fluid Highly viscous fluid * Foreign particles included * Fluid type Water, Lubricant Standard sizing Service temperature * Contact KITZ for actuator sizing, where mark is indicated. * Solvents, such as Kerosene, naphtha or alcohol. * Viscosity ranges from 0000 CP to 50000 CP. * Inclusion of powder and slurry. Sizing condition: Butterfly valve Fluid type Velocity (Liquid) Air, gas or steam, 0.9 MPa or lower Standard sizing Solvents * Vacuum or Oil free service Smooth fluid (Clean water, lubricant, etc) m/sec or slower *Contact KITZ for advice when: Service conditions do not meet those specified above. Valve operation is interrupted for more than months. Service temperature shall be limited by the seat material of the valve Type / Bore Ball Valve / Full Bore Shell materials Class Connection Product code Size mm 0 5 0 5 40 50 5 80 00 5 50 00 50 00 50 400 inch /8 / /4 /4 / / 4 5 8 0 4 Threaded 0FCT Cast Iron 0FCTB JIS 0K Flanged EXH-4 (EXS-4) Ductile Iron 0STBF Steel Threaded 0UT Steel /Carbon Steel Class 50 JIS 0K Class 00 Flanged 50UTDZ 50SCTDZ EXH- EXH- EXH- (EXS-) (EXS-) 0UTDZ EXH-4 (EXS-4) 0SCTDZ 00UTDZ 00SCTDZ EXH-5 (EXS-5) 0UTDZ JIS 0K 0SCTDZ JIS 0K Class 50 50UTR EXH- EXH- Steel JIS 0K (EXS-) (EXS-) Ball Valve Class 00 00UTR EXH-4 / Reduced Port Flanged JIS 0K (EXS-4) Carbon Class 50 50SCTR Steel JIS 0K Class 00 00SCTR Ball Valve / Full Bore way 0UTB4T(L)A EXH- EXH- EXH-4 JIS 0K Flanged Ball valve Steel / Full Bore PFA Lining 0UTBLN EXH- EXH- EXH- Butterfly Valve Aluminum Ductile Iron Steel 0XJME Note JIS 0K 0XJSME Note EXS- 0DJ Wafer EXS- JIS K BS PN DJ, PNDJ JIS 0K 0UB EXS-4 JIS K UB EXS-4 EXH-5 (EXS-5) * Max. differential pressure: 0.5 MPa (Note ) Consult KITZ, when the actuator is mounted on -way ball valves. The pattern of flow directional form is limited. (Note ) Consult KITZ, when the actuator is mounted on manual operation valves. Special parts are needed to mount the actuator. Dimensions of flange Actuator ISO Flange Diameter of raised face Axis side length Axis depth EXH- F05 + F07 5 9 EXH- EXS- F05 + F07 5 EXH- EXS- F05 + F07 + F0 55 7 5 EXH-4 EXS-4 F07 + F0 + F 55 7 4 EXH-5 EXS-5 F4 00 φ8 key way (0 x 8) 5 5

Precautions CAUTION Ensure to read and follow instructions of operation manual when handling the actuator introduced in this catalog. Handle the product carefully so that it may not fall or drop on the ground. Any extraordinary mechanical impact should be avoided. Indoor storage of the product in a dust-free, low humidity and wellventilated place is recommended. DO T remove protective cover until installation. DO T apply excessive load or step on the product, which may damage the product or cause personal injury. Allow sufficient room for manual operation or the removal of the actuator cover, when the valve is installed in the pipeline. Where the actuator is exposed to sunlight or rainwater while in service, use appropriate protection for trouble-free operation. Also use insulation boards for heat generated from the equipment around the actuator. Take some appropriate measures, if the possibilities of damage by briny atmosphere, snow or freezing are expected. Avoid installing the valve where the actuator may be hampered by vibration caused by equipment such as pumps or engines. Before installation, the connecting pipes should be cleaned to remove any foreign objects such as sand, dust or welding spatters. When threaded valves are screwed into pipes, apply a spanner to the ends of valves on the side of the connecting pipe being inserted. For flanged valves, alternately tighten bolts of the end flanges in a star pattern to ensure to fasten the flanges properly. The actuator should not be mounted downward in any piping orientation. The pipeline should be flushed to remove foreign particles from pipes. If cast iron or cast carbon steel valves are used in the water line, be aware that rust may develop in the valves, which may damage the ball seats, leading to operation failure. Pay extra attention on valve selection and protection from rust. Connect cables correctly in accordance with the circuit diagram. Ensure to use a terminal base when connecting cables. After connecting cables, conduct an insulation resistance test to ensure its insulation. Ensure the housing is securely sealed with such sealing materials as O-rings to prevent dust or water from entering the housing. DO T try to operate two or more actuators at the same time with only one operation switch. Other electrical equipment should not also be operated at the same time with one operation switch. Ensure the space heater to be activated all the time to keep the inside of the actuator warm for the prevention of due condensation, which may result in operational malfunction. Ensure the actuator is powered off, when it is used for manual operation. Place at least one-second interval, when the direction of operation is reversed. Failure to follow this instruction may result in operation malfunction. DO T make any unauthorized modifications. Such modifications may result in causing a troubled operation or accidents. We shall not be responsible for any troubles or accidents caused by improper use of the products. Refer to our catalogs for more details on valve information. WARNING This product is not designed for explosion-proof. DO T use it in any inflammable or corrosive gaseous environment. Also DO T use it for handling inflammable fluid. DO T disassemble the actuator while the unit is being energized. DO T put your fingers or insert any foreign objects within the valve core before or during valve operation.

05 ITP