MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

Similar documents
MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

MAR SERIES Fluorescent Lighting for Hazardous Locations

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

SXPJ SERIES S X azz.com/rigalite

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

FPF LED SERIES F P F L E D. Linear Non-Metallic Fixture for Food Processing

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

DuraPro Hazardous Area Fluorescent

Applications. Illustrated Features

MagnaPro Hazardous Area Drop Lens Fluorescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

Rig-A-Lite LED Luminaire Guide. Superior LED Technology for Hazardous and Severe Environments. Five-Year Warranty

AFL FLOODLIGHT SERIES

Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

Fluorescent Lighting: Enclosed and Gasketed

Applications. Standard Materials

Areamaster LED Flood/High Bay Luminaires

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Lighting: Explosionproof Area HID. Applications. Standard Materials

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Vaporproof Strip - 4 Foot 1-3 Lamps

Haz. HazMax Intrepid/nm TECHNICAL SPECIFICATIONS

Applications. Standard Materials. Certifications and Compliances

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

Applications. Standard Materials. Certifications and Compliances

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Haz. HazMax Summit/ss TECHNICAL SPECIFICATIONS


Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

L1L Series. LED Luminaire for Harsh and Hazardous Environments

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style (fluorescent replacement)

003 3 foot foot RUN Nominal Length* * For actual lengths see

Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L

Champ MLL LED luminaires

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

COMPACT FLUORESCENT EMERGENCY FIXTURES

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

N2MV Series W Non-metallic

KH Series Kemlux III Enclosed/Gasketed

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

LED Flat Panel Luminaires

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

Class I Division 2 LED Pivoting Light - 4 foot 3 lamp - LED Oil Rig Fluorescent Replacement

VSL4 Series. Description. Specifications. 2.13in. 2.03in. 3.50in

72-P-SD. MOD 72 Pendant Semi-Direct. Ordering Guide. Key Features 72-P-SD. Fixture Type: Project Name: Quick Find litecontrol.com

LED Flat Panel Luminaires

Example: DWAE51L840-4-UNV-MD360W. Lumen Package Color Temp. Length Voltage Driver Options Installed

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety


Lighting Systems Argus-7

Seem mm 4.50" 4.00" 101.6mm. Narrow 4" linear fluorescent allows for both individual or continuous runs.

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Sealtight LED Luminaire

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

apollo 8 patient bed light with LED options features dimensional data performance

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description

Nera. detail. fixture information. Unique aesthetic inspired by the visual void design philosophy. Luminaire sizes available in 2 x2, 3 x3 and 4 x4.

Apollo 8. lamping. patient bed pair example. 8" wide recessed patient bed light with exam function available in 2', 3' & 4' lengths.

LED Flat Panel Luminaires

WASHDOWN SERIES 2 LED MODULES v 1.0 FIXTURE SPECIFICATION SHEET TYPE

LED lighting for hazardous areas Champ MLL LED Luminaires. Champ MLL. LED luminaires for hazardous areas

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

2 LED Designer Series

MOGUL BASE HID FIXTURES

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100

Seem 6. Narrow 6 aperture slot fluorescent luminaire that integrates with the ceiling for a clean unobtrusive aesthetic.

LightWave Lighting Technology

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

LEN Series 2x2 / 2x4 LED

Bionic Perimeter Standard C o v e & P e r i m e t e r

4" (10cm) 15H1-250W 18F1/F1E - 62W K 18H1-300W. Standard 120V (leave blank) 2 230V 50Hz 3 277V 60Hz. 14" (36cm)

DURA BAY LINEAR SERIES

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview

Class 1 Division 2 - Class 2 Division 1&2 - Explosion Proof Low Profile LED Light Fixture

C4X4L10DL Calculite LED 4 1/2" x 4 1/2" downlight

Transcription:

MHD2/MHDO SERIES Marine Heavy Duty Outdoor Non-Metallic Fluorescent Non-metallic, glass reinforced polyester housing. 3/4 in. NPT aluminum hub. Captive stainless steel latches. Stainless steel mounting brackets. Heavy duty aluminum ballast tray. Heavy duty injection molded lens with reinforced corners. Housing: Corrosion free high impact fiberglass housing Water tight gasket attached to the lens Captive SS latches Heavy duty aluminum ballast tray 3/4 in. NPT aluminum conduit hubs 4 ft. models with 1, 2, or 3 lamp versions Diffuser: High Impact DR acrylic diffuserpolycarbonate option available Mounting: Stainless steel mounting brackets standard (T) 8.282.56 evan@thelightsource.co (F) 888.3.457

Catalog Number Logic MHD2 1 2 3 4 5 6 1 BASIC SERIES MHD2 Non-Metallic Fluorescent Fixture Class I, Division 2, Groups A, B, C and D Class II, Division 2, Groups F & G Class III Zone 2, Groups IIA, IIB & IIC UL 1598A Marine Outside Type UL 844 Hazardous Locations UL 924 Emergency Lighting CUL 55 C Ambient Temperature MHDO Non-Metallic Fluorescent Fixture Marine Rated Only 2 LAMP CURRENT/LAMP WATTAGE 8 = 8mA, 6 Watt 2 43 = 43mA, 34/2 Watt (export only) 425 = 425mA, 4/2 Watt (Slimline) 265 = 265mA, 32/17 Watt (T8 Lamps) T5HO = 54 Watt T5HO T5 = 28 Watt T5 T8HO = 44 Watt T8HO (4 foot only) 3 NOMINAL FIXTURE LENGTH 2 = 2 Foot 1 4 = 4 Foot 4 NUMBER OF LAMPS 1 = 1 Lamp 2 = 2 Lamps 3 = 3 Lamps 2 5 VOLTAGE/FREQUENCY E = 12V DC F = 24V DC G = 32V DC H = 347V 6 HZ N = 347 thru 48V 5/6 HZ U = 12 thru 277V 5/6 HZ 6 OPTIONS 4 P = Polycarbonate Lens EM = Emergency Battery Backup EM NON = Non-Hazardous Emergency Battery Backup. Marine Only F = Single Fuse 3 FB = Fuse Block 3 TB = Terminal Block TW = Thru Wire Cable Installations Only L = Lamps HL = Hi-Lumen Ballast (T8 Only) PM = Pendant Mount OB = Out Board Option 12 ft. fixture not available in 3 lamp versions. 28, 43, 425mA & T8HO fixtures not available in 1 or 3 lamp versions. 3Fuse option not available for marine listed fixtures. 4Consult factory for pricing. Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts. (T) 8.282.56 evan@thelightsource.co (F) 888.3.457

Class I, Division 2, Groups A, B, C and D Class II, Division 2, Groups F and G Zone 2, Groups IIA, IIB and IIC UL 1598A Marine Outside Type UL 844 Hazardous Locations IP66 Suitable for indoor use Non-metallic, impact resistant fiberglass housing Water tight gasket attached to lens High impact acrylic lens with stainless steel lens tethers Captive SS latches Heavy duty aluminum ballast tray Non-metallic terminal tube Stainless steel mounting brackets 2 ft. and 4 ft. models (Lamps not included) Description Voltage Catalog Number Two Foot Fixture Four Foot Fixture 2 Watt, Rapid Start, F2T12 Medium Bi-Pin, 43mA Lamps, 24" (export only) 17 Watt, Instant Start, F17T8 Medium Bi-Pin, 265mA Lamps, 24" 2 Watt, Instant Start, F24T12 Slimline, Single Pin, 425mA, 24" 34 Watt, Rapid Start F4T12, Medium Bi-Pin 43mA Lamps, 48" (export only) 2 Watt, Instant Start, F24T12 Slimline, Single Pin, 425mA, 48" 32 Watt, Instant Start F32T8, Medium Bi-Pin 265mA Lamps, 48" 54 Watt, T5HO Miniature Bi-Pin 2 Lamp, 48" 12-277V 5/6 HZ MHD243-2-2-U 12-277V 5/6 HZ MHD2265-2-2-U 12V DC MHD2425-2-2-E 24V DC MHD2425-2-2-F 32V DC MHD2425-2-2-G 12-277V 5/6 HZ MHD243-4-2-U 12V DC MHD2425-2-2-E 24V DC MHD2425-2-2-F 32V DC MHD2425-2-2-G 12-277V 5/6 HZ MHD2265-4-2-U 12-277V 5/6 HZ MHD2T5HO-4-2-U (T) 8.282.56 evan@thelightsource.co (F) 888.3.457

Fixture Dimension (inches) A D B C E Nominal Fixture Boxed Shipping Volume Length A B C D E Weight (Boxed Fixture) Two Foot Fixture 7.625 4.98 7.625 12.438 29 13.44 lbs. 1.1 cu. ft. Four Foot Fixture 6.88 5. 7.88 36.63 53.13 25.2 lbs. 2. cu. ft. Certification Guide Model Ambient Temperature ( C) Class I, Div. 2 Groups A, B, C & D Class II, Div. 2, Groups F & G, Supply Wire Suitable Temp Class III C MHD2 425, 43, 8 4 T4 T3C 9 MHD2 265 4 T4 T3C 9 MHD2 265 55 T4A - 9 MHD2 T5, T5HO 4 T4 T3C 9 MHD2 T5, T5HO 55 T3C - 9 MHD2 T8HO 4 T4 T3C 9 MHD2 T8HO 55 T4A - 9 (T) 8.282.56 evan@thelightsource.co (F) 888.3.457

Candlepower Distribution MHD2265-4-2 Coefficients of Utilization PhotometricData Deg. Parl. 22.5 45. 67.5 Norm % Effective Ceiling Cavity Reflectance rcc 8 5 1 5 15 25 35 45 55 65 75 85 9 95 15 115 125 135 145 155 5 194 194 157 978 867 718 531 3 14 38 1 4 194 192 3 13 912 789 632 44 268 147 12 78 41 2 194 192 177 14 991 96 78 61 463 314 261 159 7 2 7 194 188 19 185 6 11 899 747 598 432 365 331 249 134 37 14 5 194 19 198 113 193 143 932 781 631 458 42 373 292 172 57 8 1 % Wall Reflectance rw Room Cavity Ratio RCR 5 3 1 5 3 1 5 3 1 Effective Floor Cavity Reflectance 2%.93.93.93.84.84.84.74.74.74 1.76.71.66.68.64.61.59.57.54 2.64.57.51.57.52.47.49.46.43 3.55.47.41.49.43.38.42.38.34 4.48.39.33.43.36.31.37.32.28 5.42.34.28.38.31.26.33.28.24 6.37.29..34.27.22.29.24.2 7.33.26.2.3.24.19.26.21.18 8.3..17.27.21.17.24.19.15 9.27.2.15.25.19.15.22.17.13 1.25.18.14..17.13.2.15.12 Candlepower Distribution MHD2265-4-3 Coefficients of Utilization PhotometricData Deg. 5 15 25 35 45 55 65 75 85 9 95 15 115 125 135 145 155 5 Parl. 1585 1466 131 176 797 474 211 58 6 22.5 38 1594 154 1368 1184 948 66 42 22 153 117 61 3 45. 38 156 1487 1359 117 9 694 471 392 345 9 15 3 11 3 67.5 32 35 27 1599 1515 1348 112 987 647 548 496 373 21 56 2 8 Norm 35 47 55 4 1565 1398 1172 947 686 64 56 438 257 86 12 2 % Effective Ceiling Cavity Reflectance rcc % Wall Reflectance rw Room Cavity Ratio RCR 8 5 1 5 3 1 5 3 1 5 3 1 Effective Floor Cavity Reflectance 2%.93.93.93.84.84.84.74.74.74 1.76.71.66.68.64.61.59.57.54 2.64.57.51.57.52.47.49.46.43 3.55.47.41.49.43.38.42.38.34 4.48.39.33.43.36.31.37.32.28 5.42.34.28.38.31.26.33.28.24 6.37.29..34.27.22.29.24.2 7.33.26.2.3.24.19.26.21.18 8.3..17.27.21.17.24.19.15 9.27.2.15.25.19.15.22.17.13 1.25.18.14..17.13.2.15.12 (T) 8.282.56 evan@thelightsource.co (F) 888.3.457 RIG-A-LITE

Accessories Fixed Mounting Kit Stainless Steel Fixed 45 Catalog Number: 537 Shipping Weight: 2 lbs. (T) 8.282.56 evan@thelightsource.co (F) 888.3.457