East Central College

Similar documents
SECTION WIRING DEVICES

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

SNAPConnect. Savings and Productivity......Are Just a SNAP Away!

SECTION PANELBOARDS

IN2 Enclosed Switches and Circuit Breakers

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

SNAPConnect. Savings and Productivity Are Just a SNAP Away!

Quik-Spec Coordination Panelboard Specifications

Switches. AC-Quiet Commercial Specification Grade Switches. Commercial Grade

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

BUSWAY Low Voltage (Pow-R-Flex)

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. Submit manufacturer's literature and technical data before starting work.

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

University of Houston Master Construction Specifications Insert Project Name

VERTICAL LIFT FIRE/BLAST DOORS

Publication No.: PSG

SECTION MOTOR REQUIREMENTS for HVAC

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Permit for Charging Equipment Installation Electric Vehicle Supply Equipment (EVSE)

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Hospital Products HBL Extra Heavy Duty Hospital Grade Duplex Receptacles

TRBR20WBXSP 20A TR Comm WH Dup Rec. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight.

500 Ocean Electrical Device Submittals

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

STRAIGHT BLADE PLUGS & CONNECTORS

Premium industrial grade isolated ground straight blade receptacles

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SECTION MOTOR CONTROL

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

7. Residential Single-Family and Duplex Buildings (Dwellings)

Weather Protective Devices

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Weatherproof Boxes, Covers, Lampholders and Lighting Fixtures

Arrow Hart hospital grade GFCI modular receptacles

SW Tog DP 30A 120/277V Autogrd B&S WH

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Floor Boxes. Flush Power and Communications. FPT4 Series Poke-Through: 4 Power and Communications. FPT4 Series Poke-Through: Covers

Premium industrial grade straight blade receptacles

SECTION HVAC POWER VENTILATORS

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC/NYLON

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

Three-Phase Pole Mounted Recloser

Non-Metallic Weatherproof Boxes, Covers and Lampholders

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

1. Field verify measurements and circuiting arrangements as shown on as-built drawings.

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

STRAIGHT BLADE PLUGS & CONNECTORS

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

Generator Fire Safety: Generator assemblies should be located outside the building.

5.2. Power Pedestals. Contents Description

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Open-Style Power Distribution Blocks

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

A. This section includes unit capacitors for power factor correction.

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Plugs and Receptacles: Hazardous Location

Covers for Cast Iron or Aluminum Device Boxes

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Wallplates & Weather Protective Covers

PDI PowerWave 2 Bus System

X1PB: Explosionproof Panelboards

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

SECTION DISTRIBUTION AND GROUNDING

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

Special Specification 6058 Battery Back-Up System for Signal Cabinets

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

INSULGRIP Plugs and Connectors

Spring-loaded cover seats against neoprene gasket.

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

SECTION MOTOR CONTROLLERS

General Specifications for Lighthouse Power Pedestal

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Lighting and Power Distribution Panelboards

Transcription:

SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Wall switches. b. Receptacles c. Device plates and decorative box covers. 1.2 RELATED SECTIONS A. Division 1 Submittal Procedures. B. Section 260534 - Boxes. 1.3 REFERENCES A. NEMA WD 1 - General Requirements for Wiring Devices. B. NEMA WD 6 - Wiring Device -- Dimensional Requirements. C. NFPA 70 - National Electrical Code, 2008 edition. 1.4 SUBMITTALS A. Submit under provisions of Division 1. B. Product Data: Provide manufacturer's catalog information showing dimensions, colors, and configurations. C. Submit manufacturer's installation instructions. 1.5 QUALIFICATIONS A. Manufacturer: Company specializing in manufacturing the Products specified in this section with minimum 3 years experience. 1.6 REGULATORY REQUIREMENTS A. Conform to requirements of NFPA 70. B. Furnish products listed and classified by a NRTL as suitable for purpose specified and shown. WIRING DEVICES 262726-1

PART 2 - PRODUCTS 2.1 WALL SWITCHES A. Manufacturers: 1. Hubbell. 2. Leviton. 3. P&S. B. Description: NEMA WD 1, heavy-duty AC only general-use snap switch. If using stranded conductor provide device suitable for that use. C. Device Body: White plastic with toggle handle. D. Ratings: 1. Dielectric Withstand Voltage: 1500V minimum. 2. Overload; Minimum 4.8 times rated current for 100 cycles. 3. Temperature Rise: 30 Deg. C maximum at rated current. 4. Endurance: 50,000 cycles minimum, resistive, inductive, tungsten filament lamp load. 5. Voltage: 120-277 volts, AC. 6. Current: 20 amperes. E. Certification: UL Listed to UL Standard 20; Federal Specification WS896E listed; NEMA WD-1. F. Provide switches as indicated on the drawings. 2.2 RECEPTACLES A. Duplex Receptacle 1. Hubbell. 2. Leviton. 3. P&S B. Description: NEMA WD 1; industrial specification grade general-use receptacle. If using stranded conductor provide device suitable for that use. 1. Color: General Purpose white, unless noted otherwise. 2. Ratings: a. NEMA Type 5-20R b. Dielectric Withstand Voltage: 2000V minimum. c. Overload; Minimum 4.8 times rated current for 100 cycles. d. Temperature Rise: 30 Deg. C maximum at rated current after 50 cycles of overload at 150% of rated current with direct current. e. Voltage: 250 volts, AC. f. Current Interrupting: Certified for current interrupting at full rated current, 20 amperes. C. GFCI Receptacle: Convenience receptacle with integral ground fault circuit interrupter to meet regulatory requirements. 1. Color: White. 2. Ratings: WIRING DEVICES 262726-2

a. Dielectric Withstand Voltage: 2000V minimum. b. Overload; Minimum 4.8 times rated current for 100 cycles. c. Temperature Rise: 30 Deg. C maximum at rated current after 50 cycles of overload at 150% of rated current with direct current. d. Voltage: 250 volts, AC. e. Current Interrupting: Certified for current interrupting at full rated current, 20 amperes. D. Combination AC/USB duplex receptacle 1. Color: White. 2. Provide with (2) USB charging ports. 3. Ratings: a. Dielectric Withstand Voltage: 2000V minimum. b. Overload; Minimum 4.8 times rated current for 100 cycles. c. Temperature Rise: 30 Deg. C maximum at rated current after 50 cycles of overload at 150% of rated current with direct current. d. Voltage: 250 volts, AC. e. Current Interrupting: Certified for current interrupting at full rated current, 20 amperes. f. USB ports: 1) 5V. 2) USB 2.0 and 3.0 compatible. 3) 3.1A charging capability 2.3 WALL PLATES A. Decorative Cover Plate: Nylon beveled type with smooth rolled outer edge. 1. Acceptable Manufacturers: a. Cooper Wiring Devices b. Leviton c. P & S 2. Color to match device color. 3. For devices fed from a Computer Power Panel ( C in the circuit number), permanently emboss cover plate with Computer Use. B. Jumbo Cover Plate: Nylon beveled type with smooth rolled outer edge. Acceptable Manufacturers: 1. Cooper Wiring Devices 2. Leviton 3. P & S C. Weatherproof Cover Plate: Weatherproof In-Use Cover: Polycarbonate or impact resistant thermoplastic covers with stainless steel springs. Gray in color. Cover shall be listed as weatherproof with plug inserted into the receptacle. Cover shall be lockable by padlock. Provide for each exterior receptacle and as indicated on the plans. Cover shall be configured for horizontal mounting of receptacle. Acceptable Manufacturers: 1. Cooper Wiring Devices 2. Leviton 3. P&S 4. Raco PART 3 - EXECUTION WIRING DEVICES 262726-3

3.1 EXAMINATION A. Verify that outlet boxes are installed at proper height. B. Verify that wall openings are neatly cut and will be completely covered by wall plates. C. Verify that boxes are adjusted properly. D. Verify that branch circuit wiring installation is completed, tested, and ready for connection to wiring devices. 3.2 PREPARATION A. Provide extension rings to bring outlet boxes flush with finished surface. B. Clean debris from outlet boxes. 3.3 INSTALLATION A. Install devices plumb and level. B. Install switches with OFF position down. C. Install receptacles with grounding pole on bottom. D. Connect wiring device grounding terminal to branch circuit equipment grounding conductor per NEC. E. Install decorative plates on switch, receptacle, and blank outlets in finished areas. F. Connect wiring devices by wrapping conductor around screw terminal. Specification grade heavy duty screw clamps may be used. Do not wire through devices. G. Use jumbo size plates for outlets installed in masonry walls. H. Install galvanized steel plates on outlet boxes and junction boxes in unfinished areas, above accessible ceilings, and on surface mounted outlets. I. Install hinged cover and flanges on concealed service floor boxes. J. Ceiling mounted receptacles shall be mounted within the ceiling pad. No receptacles are to be installed above the ceiling. Provide a 10 foot flexible conduit from the junction box to the device to allow for relocation. K. Clearly write the panel name and circuit number serving each wiring device with indelible marker on the back of each coverplate. 3.4 COORDINATION WIRING DEVICES 262726-4

A. Coordinate locations of outlet boxes provided under Section 260534 to obtain mounting heights specified and indicated on drawings. B. Coordinate location of outlet with furniture layouts. C. Install wall switch at 48 inches above finished floor. D. Install convenience receptacle 18 inches above finished floor unless indicated otherwise. E. Install convenience receptacle 6 inches above counter or backsplash of counter. 3.5 FIELD QUALITY CONTROL A. Inspect each wiring device for defects. B. Operate each wall switch with circuit energized and verify proper operation. C. Verify that each receptacle device is energized. D. Test each receptacle device for proper polarity. E. Test each GFCI receptacle device for proper operation. 3.6 ADJUSTING A. Adjust devices and wall plates to be flush and level. 3.7 CLEANING A. Clean exposed surfaces to remove splatters and restore finish. END OF SECTION 262726 WIRING DEVICES 262726-5