DISTRIBUTION DESIGN CATALOGUE

Similar documents
DISTRIBUTION DESIGN CATALOGUE

DISTRIBUTION DESIGN CATALOGUE

DISTRIBUTION DESIGN CATALOGUE

Distribution Design Catalogue

Distribution Design Catalogue

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS

Heavy Duty 3500/5000. psi rating. series. hydraulic cylinders. bulletin 0207XH

Locating Ground Mounted Equipment

EDS FUSE RATINGS AT DISTRIBUTION SUBSTATIONS

Rapid Response. Lineside Signal Spacing. Railway Group Standard GK/RT0034 Issue Three Date September 1998

Director P. O. Box 1904 Service Engineering Operations Dearborn, Michigan Ford Customer Service Division

SERVICE PROCEDURE. Revision 1 updated Table 1 to include old / new part number combination C91 / C92.

Construction and Connection of Street Light Assets

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Structural Requirements For Drawgear And Buffers On Railway Vehicles

SUBSTATION TEMPORARY PORTABLE EARTHING Super Standard List

Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D

Municipality Generator Interconnection Application Single Meter Application Part I

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION

Installation Manual Installation Kit. for EPG 1712/1724 Electric Actuator on the Caterpillar D3406 Engine. Manual 54086

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

Mechanical Trainstop Systems

Controlling the Speed of Tilting Trains Through Curves

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

026-2 : 1996 CEB STANDARD

Item Code Description Unit Qty Total

LIST OF EFFECTIVE PAGES Insert latest changed pages ; dispose of superseded pages in accordance with applicable regulations. NOTE : On a changed page,

SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION

AS/NZS 3112:2004 AS/NZS

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

Senior Swing Control Box. Table of Contents

EOS HAWKER SIDDELEY SWITCHGEAR ECLIPSE - ACTUATOR FUSE

Product capability list

Risk Management of Rail Vehicle Axle Bearings

CO P P E R C A B LES A N D C O N N E C TO R S (P TY)

EDS ELECTRIC VEHICLE CONNECTIONS

HYDRAULIC CRIMPING TOOL HT51

URD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail

Sconce INSTALLATION INSTRUCTIONS P C

12-SDMS-02 REV. 05 ( )

Submission on the Wellington Town Belt Bill. Local Government and Environment Select Committee Parliament Buildings Wellington

Permissible Track Forces for Railway Vehicles

This page is intentionally left blank.

QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL

Guidelines when working near TasNetworks electrical assets

EARTH WIRE FITTINGS 08

MP ES/ED. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Meter Box - Queensland

TECHNICAL SUPPORT MANUAL Fan Coils FSM4X6000AT

Australian/New Zealand Standard

Control, Safe Use and Operation of Road-Rail Plant

San Joaquin Valley Unified Air Pollution Control District Permit Services Division

Status Date Prepared Reviewed Endorsed Approved

Expansion Signal (XSIG) Card Installation Instructions

---:...-- Environmental Health & Safety RADIATION PROCEDURES MANUAL. Procedure Cover Sheet. Procedure Number: EHS REV 2

Sconce INSTALLATION INSTRUCTIONS P34024W

All Dealer Principals, General Managers, Service Managers, and Parts Managers

Guideline for Parallel Grid Exit Point Connection 28/10/2010

IRISH COAST GUARD. ADMINISTRATION OF IRCG VEHICLES Procedure No. VS&T04 IRCG Division: VS&T

Plumas County Record of Surveys

Interface between Rail Vehicle Weights and Underline Bridges

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Technical Specification 43-8 Issue Amendment

2017 PETROLIAM NASIONAL BERHAD (PETRONAS)

HST ANTI-SPALL WINDSCREENS (0071/070042)

Installation Manual Installation Kit. for EPG 1712/1724 Electric Actuator on the Caterpillar 3208 Engine. Manual (Revision A)

2312G Turbine Temperature Indicating System Test Set

*70954* 240V Senior Swing Control Box Installation Instructions CAUTION WARNINGS. Table of Contents

S. K. Industrial Corporation

Installation Kit. Product Manual (Revision NEW) Original Instructions

CATALOG. Blackburn Flexible braids

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

Product Manual (Revision NEW) Original Instructions. Synchronous Motor Operated Potentiometer Operation Manual

Hydraulic Fittings. Design, Manufacture, Distribution

Department of Electrical and Computer Engineering

DATE: February 24, 2014 Service Instruction No. 1009AW (Supersedes Service Instruction No. 1009AV) Engineering Aspects are FAA Approved

November 8, 2004 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION

Compatibility Between Electric Trains and Electrification Systems

Civil Works Construction Cost Index System (CWCCIS)

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR ECONOMIC AND FINANCIAL AFFAIRS BUSINESS AND CONSUMER SURVEY RESULTS. April 2011

18V CORDLESS HYDRAULIC CRIMPING TOOL B500

American Champion Aircraft Corp. Rochester, WI 53167

Airworthiness Directive

Adjustable Pneumatic Time Delay Switch

Director P. O. Box 1904 Service Engineering Operations Dearborn, Michigan Ford Customer Service Division

Illustrated Parts Catalogue Woodward Diesel Systems. Illustrated Parts Catalogue. Perkins Engines (formerly Perkins Dorman) Pumps & Injectors

TECHNICAL SPECIFICATION

DISCUSSION DOCUMENT. New standards for off-road small spark-ignition engines under consideration

MECHANICAL CYLINDERS Operating Instructions

Director P. O. Box 1904 Service Engineering Operations Dearborn, Michigan Ford Customer Service Division

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

TORQUE TESTERS FLEXIBLE-BEAM AND TORSION-BAR TYPES 5 OZ-IN TO 1000 LB-FT THIS PUBLICATION SUPERSEDES NAVAIR 17-20MU-03 DATED 1 MAY 1994

VALIDITY AND INFORMING OF CHANGES...

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

TECHNICAL SPECIFICATION

Installation and Maintenance Manual for SPANCO A Series Aluminum Gantry Cranes

Transcription:

DISTRIBUTION DESIGN CATALOGUE Section 02 PO Poles HPC-1DC-07-0002-2014 For application to Horizon Power Electricity Distribution Networks

Document Control Author Name: Paul Savig Position: Senior Standards Engineer Document Owner (May also be the Process Owner) Name: Position: Paul Savig Senior Standards Engineer Approved By * Name: Jose Duarte Position: Engineering Services Manager Date Created/Last Updated March 2018 Review Frequency ** Annually Next Review Date ** March 2019 * Shall be the Process Owner and is the person assigned authority and responsibility for managing the whole process, end-to-end, which may extend across more than one division and/or functions, in order to deliver agreed business results. ** Frequency period is dependent upon circumstances maximum is 5 years from last issue, review, or revision whichever is the latest. If left blank, the default shall be 1 year unless otherwise specified. Revision Control Revision Date Description 5 21/01/2014 Minor Drawing and Stock additions 6 30/01/2015 PO12 to PO14 A-Frame added 7 26/03/2018 Addition of Hayman poles PO21 to PO25, removal of A-Frame PO12 to PO14 and Round PO17 STAKEHOLDERS The following positions shall be consulted if an update or review is required: District Managers Manager Asset Management Services NOTIFICATION LIST The following positions shall be notified of any authorised change: Project Director, Major Projects Project Director, Engineering & Project Services All Other Key Groups outside of Operations Document Title: Distribution Design Catalogue Page 2 of 14 Issue Date: 27/03/2018

POLES LIST PO15 PO16 PO19C PO21 PO22 PO23 PO24 PO25 DESCRIPTION Regional Tubular steel pole 9.5 m, 10 kn (Ultimate Load) Regional Tubular steel pole 11 m, 10 kn (Ultimate Load) Earthing of Conductive Pole 12 sided steel pole 9.5 m, 20 kn (Ultimate Load) 12 sided steel pole 11 m, 20 kn (Ultimate Load) Non-cyclonic 12 sided steel pole 11 m, 30 kn (Ultimate Load) Cyclonic 12 sided steel pole 12 m, 40 kn (Ultimate Load) 12 sided steel pole 14 m, 35 kn (Ultimate Load) Note Description No. 1 Only applicable for construction with overhead earthwire or running earthwire. Document Title: Distribution Design Catalogue Page 3 of 14 Issue Date: 27/03/2018

Document Title: Distribution Design Catalogue Page 4 of 14 Issue Date: 27/03/2018

Document Title: Distribution Design Catalogue Page 5 of 14 Issue Date: 27/03/2018

DESCRIPTION PO15 Regional Tubular steel pole 9.5 m, 10 kn (Ultimate Load) 1 CW0455 Tubular Steel pole 9.5 m, 10 kn (Ultimate Load) 1 ea 2 CZ0230 Danger label 1 ea 3 CE0058 Earthing clamp 1 ea 4 CE0078 Coupling Tube ALM NO OCT15 1 ea 5 CE0135 Rod section 1.4 m long 15 mm diam ALM CTE 2 ea 6 CE0201 Earth terminal box 1 ea 7 EE1264 wire 70 sq mm 19/2.14 stranded copper 1 mtr 8 FL1465 terminal lug eye 1 ea 9 AB2959 Screw M12 40 mm long 1 ea 10 AW2429 washer spring M12 1 ea 11 AW2607 washer flat 1/2IN 1 ea DESCRIPTION PO16 Regional Tubular steel pole 11 m, 10 kn (Ultimate Load) 1 CW0451 Tubular Steel pole 11 m, 10 kn (Ultimate Load) 1 ea 2 CZ0230 Danger label 1 ea 3 CE0058 Earthing clamp 1 ea 4 CE0078 Coupling Tube ALM NO OCT15 1 ea 5 CE0135 Rod section 1.4 m long 15 mm diam ALM CTE 2 ea 6 CE0201 Earth terminal box 1 ea 7 EE1264 wire 70 sq mm 19/2.14 stranded copper 1 mtr 8 FL1465 terminal lug eye 1 ea 9 AB2959 Screw M12 40 mm long 1 ea 10 AW2429 washer spring M12 1 ea 11 AW2607 washer flat 1/2IN 1 ea Document Title: Distribution Design Catalogue Page 6 of 14 Issue Date: 27/03/2018

Document Title: Distribution Design Catalogue Page 7 of 14 Issue Date: 27/03/2018

DESCRIPTION PO19C Earthing of Conductive Poles 1 CC0125 Bi metal parallel grove clamp 3/2.75; 7/2.50 1 ea Note 1 2 CE0058 Earthing clamp 1 ea 3 CE0078 Coupling Tube ALM NO OCT15 1 ea 4 CE0135 Rod section 1.4 m long 15 mm diam ALM CTE 2 ea 5 CE0201 Earth terminal box 1 ea 6 EE1264 wire 70 sq mm 19/2.14 stranded copper 2 mtr 7 FL1465 terminal lug eye 2 ea 9 AB2959 Screw M12 x 40 mm long 2 ea 10 AW2429 washer spring M12 2 ea 11 AW2607 washer flat 1/2IN 2 ea Document Title: Distribution Design Catalogue Page 8 of 14 Issue Date: 27/03/2018

Document Title: Distribution Design Catalogue Page 9 of 14 Issue Date: 27/03/2018

DESCRIPTION PO21 12 sided steel pole 9.5 m, 20 kn (Ultimate Load) 1 CWH0461 12 sided pole 9.5 m, 20 kn (Ultimate Load) 1 ea 2 CZ0230 Danger label 1 ea 3 CE0058 Earthing clamp 1 ea 4 CE0078 Coupling Tube ALM NO OCT15 1 ea 5 CE0135 Rod section 1.4 m long 15 mm diam ALM CTE 2 ea 6 CE0201 Earth terminal box 1 ea 7 EE1264 wire 70 sq mm 19/2.14 stranded copper 1 mtr 8 FL1465 terminal lug eye 1 ea 9 AB2959 Screw M12 40 mm long 1 ea 10 AW2429 washer spring M12 1 ea 11 AW2607 washer flat 1/2IN 1 ea DESCRIPTION PO22 12 sided steel pole 11 m, 20 kn (Ultimate Load) Non-cyclonic 1 CWH0464 12 sided pole 11 m, 20 kn (Ultimate Load) 1 ea 2 CZ0230 Danger label 1 ea 3 CE0058 Earthing clamp 1 ea 4 CE0078 Coupling Tube ALM NO OCT15 1 ea 5 CE0135 Rod section 1.4 m long 15 mm diam ALM CTE 2 ea 6 CE0201 Earth terminal box 1 ea 7 EE1264 wire 70 sq mm 19/2.14 stranded copper 1 mtr 8 FL1465 terminal lug eye 1 ea 9 AB2959 Screw M12 40 mm long 1 ea 10 AW2429 washer spring M12 1 ea 11 AW2607 washer flat 1/2IN 1 ea Document Title: Distribution Design Catalogue Page 10 of 14 Issue Date: 27/03/2018

DESCRIPTION PO23 12 sided steel pole 11 m, 30 kn (Ultimate Load) Cyclonic 1 CWH0465 12 sided pole 11 m, 30 kn (Ultimate Load) 1 ea 2 CZ0230 Danger label 1 ea 3 CE0058 Earthing clamp 1 ea 4 CE0078 Coupling Tube ALM NO OCT15 1 ea 5 CE0135 Rod section 1.4 m long 15 mm diam ALM CTE 2 ea 6 CE0201 Earth terminal box 1 ea 7 EE1264 wire 70 sq mm 19/2.14 stranded copper 1 mtr 8 FL1465 terminal lug eye 1 ea 9 AB2959 Screw M12 40 mm long 1 ea 10 AW2429 washer spring M12 1 ea 11 AW2607 washer flat 1/2IN 1 ea DESCRIPTION PO24 12 sided steel pole 12.5 m, 40 kn (Ultimate Load) 1 CWH0472 12 sided pole 12.5 m, 40 kn (Ultimate Load) 1 ea 2 CZ0230 Danger label 1 ea 3 CE0058 Earthing clamp 1 ea 4 CE0078 Coupling Tube ALM NO OCT15 1 ea 5 CE0135 Rod section 1.4 m long 15 mm diam ALM CTE 2 ea 6 CE0201 Earth terminal box 1 ea 7 EE1264 wire 70 sq mm 19/2.14 stranded copper 1 mtr 8 FL1465 terminal lug eye 1 ea 9 AB2959 Screw M12 40 mm long 1 ea 10 AW2429 washer spring M12 1 ea 11 AW2607 washer flat 1/2IN 1 ea Document Title: Distribution Design Catalogue Page 11 of 14 Issue Date: 27/03/2018

DESCRIPTION PO25 12 sided steel pole 14 m, 35 kn (Ultimate Load) 1 CWH0476 12 sided pole 14 m, 35 kn (Ultimate Load) 1 ea 2 CZ0230 Danger label 1 ea 3 CE0058 Earthing clamp 1 ea 4 CE0078 Coupling Tube ALM NO OCT15 1 ea 5 CE0135 Rod section 1.4 m long 15 mm diam ALM CTE 2 ea 6 CE0201 Earth terminal box 1 ea 7 EE1264 wire 70 sq mm 19/2.14 stranded copper 1 mtr 8 FL1465 terminal lug eye 1 ea 9 AB2959 Screw M12 40 mm long 1 ea 10 AW2429 washer spring M12 1 ea 11 AW2607 washer flat 1/2IN 1 ea Document Title: Distribution Design Catalogue Page 12 of 14 Issue Date: 27/03/2018

APPENDIX A REVISION INFORMATION (Informative) Horizon Power has endeavoured to provide standards of the highest quality and would appreciate notification if any errors are found or even queries raised. Each Standard makes use of its own comment sheet which is maintained throughout the life of the standard, which lists all comments made by stakeholders regarding the standard. The document HPC-1DC-07-0002-COMM can be used to record any errors or queries found in or pertaining to this standard, which can then be addressed whenever the standard gets reviewed. Date 26/03/2018 Rev No. 7 Notes Index List PO12, PO13 PO14 & PO17 removed PO21, PO22, PO23, PO24 & PO25 added PO12 to PO14 Drawing removed PO12 to PO14 and PO17 List removed PO21, PO22 to PO25 Drawing added PO21 to PO25 List added Stock code CE0055 replaced with CE0058 30/01/2015 6 Index List PO12, PO13 & PO14 added PO12 to PO14 Drawing added PO12 to PO14 List added 21/01/2014 5 Index List PO12, PO13 & PO14 removed PO12 to PO14 Drawing removed PO12 to PO14 List removed PO15 to PO17 Drawing Items (9), (10) and (11) added PO15 to PO17 List Items (9), (10) and (11) added PO19C Drawing Items (9), (10) and (11) added PO19C Lists Items (9), (10) and (11) added 07/09/2013 4 Pole earthing added to PO12-PO17, PO18 renamed to PO19C 11/01/2012 3 Update document owners 09/10/2010 2 Review and update pole earthing Document Title: Distribution Design Catalogue Page 13 of 14 Issue Date: 27/03/2018

Date Rev No. Notes 01/07/2009 1 Original Horizon Power issue 0 Western Power Supplied Document Title: Distribution Design Catalogue Page 14 of 14 Issue Date: 27/03/2018