Limitor -G General Purpose Fuses

Similar documents
NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

Protistor size 70 gr 690VAC (IEC)

NEOZED D0 fuse-links gg 400/440VAC

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

High-voltage high-breaking capacity VV fuse-links

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

High-voltage high-breaking capacity VV fuse-links

FUSES. Safety through quality

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

Protistor size 120 gr 750VDC (IEC)

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

High voltage high-breaking capacity VV fuse-links

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Medium voltage fuses Medium voltage fuses

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

Medium voltage fuses - European Fuses

High-Voltage Fuse Links according to IEC

Medium Voltage current limiting Fuse links

Medium Voltage current limiting Fuse links

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

MEDIUM VOLTAGE DIN Fuse-Links

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

High voltage current limiting Fuse links type CEF

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

Low voltage NH knife-blade fuse-links

RAPIDPLUS. high speed fuse links for semiconductors

IEC Standard Back-Up Fuse-Links

RAPIDPLUS. high speed fuse links for semiconductors

MEDIUM VOLTAGE DIN Fuse-Links

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

General information on current-limiting fuse-links. The main characteristics of the CNC fuse-links. Construction. Operating.

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

MEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Semiconductor Fuses European Fuses

onlinecomponents.com

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

Standardized fuse characteristics

X-Limiter full-range current-limiting fuse

UL 508 Non-Fusible Disconnect Switches

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

UL 508 Non-Fusible Disconnect Switches

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

Voltage and Auxiliary Transformer Fuse Links

NH DIN Dual Indication Fuse Links

fuse-links & fuse holders PHOTOVOLTAIC

Select 700V/ ysuk.com. The. Current limiting. acceptance. protection of. within a single. recognised (10 38 fuses) October 2013

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

FUSE BASES NH FUSE BASES 690V 160A 160A

INDUSTRIAL CYLINDRICAL FUSE LINKS

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

LINOCUR Size D02 63A 230VAC/440VAC

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Low-Peak 600V Class RK1

fuses fuse holders CYLINDRICAL

LG HRC Power Fuses ISO 9001 ISO 14001

3 - Protection components Motor circuit-breakers

Medium voltage products. Fuses

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

34-SDMS-02 SPECIFICATIONS FOR

Essential equipment for all your requirements

3.6kV 36kV High Voltage DIN Distribution Fuses

Semiconductor (AC) fuses

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

Applications. Fuse range selection. Motors Power transformers. Voltage (kv)

Product Catalog Medium Voltage Fuses. Circuit Protection

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

MANUALLY OPERATED CHANGEOVER SWITCHES

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Medium voltage products. Fuses

NH Solid Blades 690 VAC sizes 000 to 3

HHBO-B. High Voltage Fuses to British Standards. Fuses for protection of oil insulated transformer mains

FMotor Circuit Controllers

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

1489-M Circuit Breakers

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Mica Element Support. Compacted Quartz Sand. Length B

Transcription:

Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor -G HV fuses are general purpose fuses as defined in the IEC 60282-1 standard and dedicated to protect transformers against effects of short-circuit currents and low overcurrents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. TECHNICAL DATA /24kV 442mm 6/12kV 292mm Rated current 4... 25 A 6.3... 50 A Rated voltage range U n /24 kv 6/12kV Rated voltage of transformer 20 kv kv Package 1 1 High breaking capacity High current limitation Low switching voltage Quick breaking Non-ageing Energy efficency New cap design for a better compatibility with all types of clips and easier assembly Coordination with IEC 60787, IEC 62271-5 and VDE 0670 T303 APPLICATIONS HV Transformer protection STANDARDS IEC 60282-1 VDE 0670 part 4 DIN 43625 EP.MERSEN.COM 1

PRODUCT RANGE Rated voltage / 24 kv, length 442mm with striker Catalog number Item number Rated current In Clearing I²t at Rated Voltage Breaking capacity I1 Cold resistance R20 (+/-%) Power dissipation at In Ø78mm 45DG240VP E00159 A 3.6 ka²s 40 ka 135 mω 15 W 45DG240V16P F00160 16 A 14 ka²s 40 ka 70.3 mω 21 W Ø88mm 45DG240V25P G00161 25 A 39 ka²s 40 ka 41.2 mω 31 W Ø78mm 45DG240V4P C00157 4 A 1.8 ka²s 40 ka 280 mω 5 W 45DG240V6,3P D00158 6.3 A 2 ka²s 40 ka 256 mω 11 W Rated voltage 6 /12 kv, length 292mm with striker Catalog number Item number Rated current In Clearing I²t at Rated Voltage Breaking capacity I1 Cold resistance R20 (+/-%) Power dissipation at In Ø65mm 45DG120VP X00152 A 3.8 ka²s 40 ka 70 mω 8 W 45DG120V16P Y00153 16 A 14 ka²s 40 ka 35 mω W 45DG120V25P Z00154 25 A 36 ka²s 40 ka 20.5 mω 15 W Ø78mm 45DG120V40P A00155 40 A 1 ka²s 40 ka 12.2 mω 24 W Ø88mm 45DG120V50P B00156 50 A 150 ka²s 40 ka 9.9 mω 31 W Ø65mm 45DG120V6,3P W00151 6.3 A 2 ka²s 40 ka 128 mω 6 W EP.MERSEN.COM 2

TIME CURRENT CHARACTERISTIC CURVES Limitor G 6-12kV 000 t[s] 6.3 16 25 40 50 Actual pre-arcing time (s) 00 0 1 0,1 0,01 0,001 6,3 16 25 40 50 0 00 000 I [A] RMS value of prospective current (A) +/- 8% EP.MERSEN.COM 3

TIME CURRENT CHARACTERISTIC CURVES Limitor G -24kV 000 t[s] 4 6,3 16 25 Actual pre-arcing time (s) 00 0 1 0,1 0,01 0,001 6,3 0 00 000 I [A] RMS value of prospective current (A) +/- 8% 4 16 25 EP.MERSEN.COM 4

CUT-OFF CURRENT CHARACTERISTIC Limitor G 6-12kV Maximum peak let thru current Ic (A) 50 Hz RMS symmetrical prospective current Ip (A) EP.MERSEN.COM 5

CUT-OFF CURRENT CHARACTERISTIC Limitor G -24kV 0000 i d [A] prospective current 1.8 2 Ik 1.0 2 Ik I r [A] Maximum peak let thru current Ic (A) 000 00 25 16 6,3 4 0 0 00 000 I K '' [A] 0000 50 Hz RMS symmetrical prospective current Ip (A) EP.MERSEN.COM 6

DIMENSIONS Ø d 30 +2 33 0 e +2 33 0 Ø 45 ± 1 Ø 15 Ø d e = length see Product range table Dimensions in mm Rated voltage Article Number 6 / 12kV W00151 292 65 6 / 12kV X00152 292 65 6 / 12kV Y00153 292 65 6 / 12kV Z00154 292 65 6 / 12kV A00155 292 78 6 / 12kV B00156 292 88 / 24kV C00157 442 78 / 24kV D00158 442 78 / 24kV E00159 442 78 / 24kV F00160 442 78 / 24kV G00161 442 88 e d EP.MERSEN.COM 7

SELECTION TABLE Relative short-circuit voltage Uk = 4% Uk = 5% Rated voltage range of fuse-link [kv] Service voltage of transformer [kv] Transformer output [kva] Transformer rated current [A] 6 / 12 / 24 20 Rated current of fuse-link [A] Transformer rated current [A] Rated current of fuse-link [A] 50 2.9 6.3 1.5-0 5.8 6.3-2.9 4 125 7.2 3.6 4-6.3 160 9.2 16 4.6 6.3 200 11.5 16 5.8 6.3-250 14.4 16-25 7.2 315 18.2 25 9.1 16 400 23.1 25-40 11.5 16 500 28.9 40 14.4 16 630 36.4 40-50 18.2 25 800 46.2 50 23.1 25 00 57.7 50 28.9 25 EP.MERSEN.COM 8