CRegulatory. Compliance: UL and CE APPENDIX C IN THIS CHAPTER. Installation Instructions Installation Guidelines System Installation Techniques

Similar documents
APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

Compliance with CE Marking and UL Standard

Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC

MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER or TIMER

o o Parker Automation

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

MODEL IRMA - INTELLIGENT RTD MODULE WITH ANALOG OUTPUT

199.9 µa to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges.

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Solid State Relays contactor with Integrated Fuse Type RGC1F

Packing Data Installation Instructions

EMC INSTALLATION INFORMATION

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

TRAC-Station BT Installation Instructions

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Installation Instructions

Compact Circuit Protector

USB3.0 for Active Optical Cable

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

Compact Circuit Protector

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

MS Application. Features. Proportional Valve Actuator General Instructions

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Features. Description. Table of Contents

INDUSTRIAL POWER SUPPLIES SFL-SERIES

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

GB60S 60W Single Output General Purpose Series

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

GK-600. Product Classification. Dimensions. Electrical Specifications. Environmental Specifications. General Specifications

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

199.9 A to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges (104.1)

MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER/TIMER

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Ensuring the Safety Of Medical Electronics

MF /MS Series

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

ALTIVAR 58 AC Drives

OICA proposal for amendments to GRE/2013/3 (Regulation No. 10)

Power Supplies. SDN-C Compact DIN Rail Series

DRB-1 Series Instruction Manual

Industrial Control Transformers

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

USB3.0 For Active Optical Cable SPECIFICATIONS

Elmdene International Ltd

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Products :: Circuit Protection :: Thermal Circuit Breakers

DC POWER SUPPLY ALIMENTATION C.C.

channel bracket 1.50 (38) flat strap shaded area is useable space

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

SMT-BM 20 A BMM 05 F BMM 05 AF

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

USB3.0 For Active Optical Cable SPECIFICATIONS

CPS2000 Cabinet Power System

Section 6 Electric Metering: Residential

3 Uninterruptible Power Systems

Single Cable Motion Solution Kinetix 5500 Servo Drive and VP Low Inertia Motor

LS200 Series Instruction Manual

CAN and Serial Instrumentation

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

Single & Three-Phase Soft Starters

Uninterruptible Power Systems

Versatile Power Entry Module with Small Footprint. PS non-filtered

ABB component drives ACS150, 0.5 to 5 Hp

Power Supplies POWER SUPPLIES TRANSIENT VOLTAGE SUPPRESSORS POWER LINE FILTERS. AC to DC Power Supply Units. AC to 24VDC Regulated Primary Switching

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Open Chassis Star-Delta Starter User Guide

L5000 Plus. Installation & Setup Guide

ACS800. Hardware Manual ACS Drives (0.55 to 110 kw) ACS800-U1 Drives (0.75 to 150 HP)

Trane Liqui-Flo Addendum. Instruction Manual D2-3415

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

3 Uninterruptible Power Systems

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

Mounting and Installation Guidelines

Security Plus Online Uninterruptible Power Supply

INTECH Micro 2300-RTD6

ACS800. Hardware Manual ACS Drives (5.5 to 110 kw) ACS800-U31 Drives (7.5 to 125 HP)

INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS

Pneumatic Isolation Module

Description 1/8-7.5HP

Electrical Installation

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

DRL-1 Series Instruction Manual

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

MAXIMUM OUTPUT AC SUPPLY INPUT SPEED RANGE USER ADJUSTMENT EXTERNAL CONTROL CONTROL ACTION INSTALLATION

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Transcription:

APPENDIX C CRegulatory Compliance: UL and CE IN THIS CHAPTER Installation Instructions Installation Guidelines System Installation Techniques Appendix C Regulatory Compliance: UL and CE 81

Regulatory Agencies The Gemini family of products is designed to meet the requirements of global regulatory agencies. Gemini products have shown compliance with the regulatory agencies in the following list. The list also shows additional steps users must take to ensure compliance. Agency UL, cul CE (LVD) CE (EMC) Additional Steps User Must Take fuses fuses; earth connection for drive and motor (if applicable), proper installation Varistors, mains filter, EMC cabling, EMC ready motor, proper installation Installation Instructions Although Gemini drives are technically considered motion control components and are therefore not within the scope of the European union s CE (Conformité Européenne) directives, Compumotor has taken the initiative to provide its customers with easy to integrate motion control products that meet global requirements. The following constitutes what is typically required to install Gemini drives into a CE compliant system. Additional installation measures may be required at some locations. The machine builder has ultimate responsibility for machine compliance. Low Voltage Directive (LVD) Installation Requirements: fuses Drive safety earth conductor safety earth (for motor voltages greater than 75 volts) Drive must be installed such that the hazardous live terminals (barrier strip) are not accessible under normal operation Electromagnetic Compatibility (EMC) Installation Requirements: Product does not need to be placed within an enclosure filter (see filter recommendations) Transient suppressors (mains surge test) Compumotor EMC cabling (requires no special cable preparation) EMC ready motor, or motor with EMC installation information Additional installation hardware as shown in drawings in this appendix Additional Steps to Ensure Compliance To meet the requirements of regulatory agencies, you must follow the installation guidelines presented below. Fuses Instructions for installing mains fuses were presented in Connecting AC Power in Chapter 2 Installation. 82 Gemini GV6 Hardware Installation Guide

EMC Electromagnetic Compatibility Directive 89/336/EEC In order to meet the requirements of the Electromagnetic Compatibility Directive 89/336/EEC, the entire system must comply: motor, drive, cabling, and peripherals. The installation of the product must include the following items. EMC Cabling For electromagnetic compatibility, you must use Parker Compumotor CE cables. EMC For system CE compliance, you must use an EMC-ready motor, or a motor that has demonstrated acceptable EMC performance. NOTE: s may bear the CE mark. This mark indicates the motor meets the requirements of construction and safety not EMC compliance. s with shielded cabling or pipe thread style cabling options allow the easiest integration into machines required to bear the CE mark for EMC. Varistors You must install varistors or other voltage surge limiting devices in order to meet the requirements of EN61000-4-5. Place a Littelfuse V275LA2Ø or equivalent varistor from line to line, and from lines to earth before the mains filter, as shown in the EMC Installation drawings later in this appendix. (Intersil, General Electric and Littelfuse manufacture equivalent varistors.) You must install a mains filter. The next table lists recommended filters. Continuous GV6-L3 : Current (amps) GV6-U3 GV6-U6 GV6-U12 GV6-H20 GV6-H40 3EP1 1 3 X 6EP1 1 9 X X 10EP1 1, 3 10 X X FN2070-10-06 2 10 X X X FN2070-12-06 2 12 X X X FN2070-16-06 2, 3 16 X X X 16FCD10 1 16 X FN351-16/29 2 16 X FN351-25/29 2 25 X 25FCD10 1 25 X 36FCD10 1 36 X FN351-36/29 2 36 X Product with applicable mains filter denoted by X 1 Corcom; 2 Schaffner; 3 Available from Compumotor: 10 amp filter part number 47-016140-01 16 amp filter part number 47-017900-01 +24VDC Power Supply If you use the +24VDC power supply Parker Compumotor offers for sale (PS-60W), no additional filter is required on the +24VDC mains. If you use another manufacturer s +24VDC power supply, it should be CE marked for safety and electromagnetic compatibility. Appendix C Regulatory Compliance: UL and CE 83

Installation Guidelines Gemini products are made available under Restricted Distribution for use in the Second Environment as described in EN 61800-3: 1996, page 9. Cabinet Mounting For Electromagnetic Compatibility, cabinet mounting is not required. However, Gemini drives have high voltage terminals for safety purposes, the drive must not be user accessible during normal operation. Drive Mounting The Gemini drive is designed to be mounted to an earthed metal panel. For EMC performance, mount the mains filter to the same panel, as close to the drive as possible. See the EMC Installation drawing at the end of this appendix. Routing Route high power cables (motor and mains) at right angles to low power cables (communications and inputs/outputs). Never route high and low power cables parallel to each other. Shielding All cables must maintain high integrity 360 degree shielding. Compumotor CE cables are fully shielded and provide the required screening. When you install limit switches and other inputs/outputs, you must observe proper noise immunity standards. See the EMC Installation drawing at the end of this appendix. Ferrite Absorbers Some installations may require that you take additional EMC measures. To further increase product immunity and reduce product emissions, you may add clip-on ferrite absorbers to all cables. Compumotor recommends a ferrite with at least 200 ohm impedance at 100 MHz, such as: Steward Ferrite part number 28A2024 Fair-Rite part number 0443164151 (These ferrites are available from Compumotor, part number 47-015956-01) Enclosure Mounting the Gemini Drive The enclosure must be properly earthed and paint must be removed from drive mounting and RF earth bonding locations. Proper shield termination of all cables entering and exiting the enclosure is required. The motor shield (braid) must be fastened to the drive using the included saddle clamp or R-Clamp. The shield must not make contact with other conductors, as this will cause common mode drive generated PWM current to flow where not expected. The shields of all other cables that enter or exit the enclosure must be RF bonded to the enclosure entrance point via R-Clamp, bulkhead clamshell clamp, or other 360 bonding technique. This ensures that no stray noise will enter or exit the enclosure. The next drawing illustrates 360 bonding techniques. 84 Gemini GV6 Hardware Installation Guide

R-Clamp Remove outer jacket only. Do not cut braid. Bulkheak Clamshell Clamp Bulkheak Clamshell Clamp Enclosure Panel Enclosure Panel 360 Bonding Techniques The following clamps and clamp kits are available from Compumotor. Clamp Type: Compumotor Part Number: R-Clamp 58-016050-01 R-Clamp Kit (10 per) R CLAMP KIT Bulkhead Clamshell Clamp 53-016131-01 Clamshell Clamp Kit (2 per) CLAMSHELL KIT Saddle Clamp 53-017355-01 If you use the GEM-VM50 or other screw terminal cable breakout device, be sure to properly enclose all exposed conductors to avoid contamination and to reduce the risk of electrostatic discharge. Limit switches and other I/O must utilize high quality shielded cabling (85% braid coverage minimum), which must be RF earth bonded as shown above. Panel Mounting the Gemini Drive The mounting panel must be properly earthed and paint must be removed from drive Gemini CE cables maintain proper RF bonding with the drive when you insert them in the correct location and tighten the headshell jackscrews. You must fasten the motor shield (braid) to the bottom of the drive, using the included saddle clamp. (GV6-H20n/H40n: R-Clamp on front of drive). The shield must not make contact with other conductors, as this will cause common mode drive generated PWM current to flow where not expected. If you use the GEM-VM50 or other screw terminal cable breakout device, be sure to properly enclose all exposed conductors to avoid contamination and to reduce the risk of electrostatic discharge. Limit switches and other I/O must utilize high quality shielded cabling (85% braid coverage minimum), which must be RF earth bonded as shown in the 360 Bonding Techniques drawing. Appendix C Regulatory Compliance: UL and CE 85

System Installation If you mount the Gemini drive in an enclosure, terminate cable braids (screens) at the entrance of the enclosure. However, the motor braid must be returned to the drive s saddle clamp (GV6-H20n/H40n: R-Clamp on front of driven), not any other location. The next figures show typical EMC installations. Gemini Drive Mount to earthed metal panel. Remove paint from flange and I/O Limits Bond braid to earthed panel. Use R-clamp or bulkhead clamshell clamp. (See 360 bonding drawing.) HPC RS-232/485 +24VDC Power Supply VDC+ VDC Twisted at 3 twists minimum per inch (25 mm) GEM-VM50 Breakout Module (enclosure mounted, or not accessible to user) Drive I/O N or L2/N VAC L1 Earth Varistor (3 places) Remove paint from flange and Saddle clamp braid; make loop as short as possible Feedback EMC Installation GV6-L3n; GV6-U3n/6n/12n 86 Gemini GV6 Hardware Installation Guide

GV6-H20n Drive Mount to earthed metal panel. Remove paint from flange and I/O Limits Bond braid to earthed panel. Use R-clamp or bulkhead clamshell clamp. (See 360 bonding drawing.) HPC RS-232/485 VAC L3 L2 L1 +24VDC Power Supply VDC+ VDC Twisted at 3 twists minimum per inch (25 mm) R clamp braid to heatsink; make loop as short as possible DRIVE I/O MOTOR FEEDBACK Ferrite absorber Drive I/O GEM-VM50 Breakout Module (enclosure mounted, or not accessible to user) Earth Feedback Varistor (3 places; for single phase, see previous drawing) Ferrite absorber detail Wrap wires through ferrite two times. Protective earth GV6- H20n Saddle clamp to bottom for mechanical strain relief, if desired Remove paint from flange and EMC Installation GV6-H20n Appendix C Regulatory Compliance: UL and CE 87

RS-232/485 GV6-H40n Drive Mount to earthed metal panel. Remove paint from flange and I/O Limits Bond braid to earthed panel. Use R-clamp or bulkhead clamshell clamp. (See 360 bonding drawing.) HPC +24VDC Power Supply VDC+ VDC Twisted at 3 twists minimum per inch (25 mm) Ferrite absorber Drive I/O GEM-VM50 Breakout Module (enclosure mounted, or not accessible to user) VAC L3 R clamp braid to drive; make loop as short as possible Feedback L2 L1 Earth Varistor (3 places) Wrap wires through ferrite two times. Protective earth Ferrite absorber detail GV6- H40n Remove paint from flange and EMC Installation GV6-H40n 88 Gemini GV6 Hardware Installation Guide