HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

Similar documents
HI Ethylene Glycol Refractometer INSTRUCTION MANUAL

Bante220 Portable ph Meter Instruction Manual

PHscan30S Pocket ph Meter Instruction Manual

ORPscan20 Pocket ORP Tester Instruction Manual

PH20 Value ph Tester Instruction Manual

PH60 Series Premium ph Testers

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Large Display ph Pens , , Instruction Manual

ECscan20 Pocket Conductivity Tester Instruction Manual

SoilStik ph Meter PRODUCT MANUAL. Item # 2105

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

TRACER. POCKETESTER ä ORP CODE 1742

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

EC1 Pocket Conductivity Tester Instruction Manual

Salt 1 Pocket Salinity Tester Instruction Manual

Tracer ORP PockeTester TM Code 1742

PHscan10S Pocket ph Tester Instruction Manual

DT304. Digital Temperature Logger INSTRUCTION MANUAL

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

EC20 Pocket Conductivity Tester Instruction Manual

Care and use guide. Contents. page

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

HI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI HI HI

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

Model P772 Conductivity Meter. User Manual

TDSscan10M Pocket TDS Tester Instruction Manual

User Manual Pocket Pro, Pro + ph

HI 96707C Nitrite Low Range ISM

MODEL IQ150 ph Meter Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE

OPERATION MANUAL PEN TYPE. Model: 8690 DESIGN PATENTED: US D S

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

INSTRUCTION MANUAL HI 921 AUTOSAMPLER

Visit us at

Visit us at

STARTER 2000 Bench ph Meter Instruction Manual

Megohmmeter Test Probe

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Single-Input Thermocouple. Thermometers Type J, K, T

HI Free Chlorine Meter

Temp-14 Single Input Thermistor Thermometer

Instruction Manual. Single-Input Thermistor Thermometer (Model )

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

COM-100 EC / TDS / TEMPERATURE METER

User Guide. Model Insulation Tester / Megohmmeter. Introduction

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Instruction Manual PORTABLE ph METER D-71

Digital Formaldehyde Meter

Thermocouple Thermometer Models

Model 2053 Conductivity Meter Instruction Manual

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Digital Thermometers Instruction Manual MODELS 868 and 869

OPERATING INSTRUCTIONS

Instruction Manual Portamess 911 Cond

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

User's Guide. CO 2 Meter. Model CO250

User s Guide HH42A. Thermometer. Shop online at omega.com sm HH42A. For latest product manuals:

BBT-205. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Agitadores magnéticos Capacidad estándar HI-304N-1 HANNA manual ingles

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Model Battery Powered Milliohm Meter

Marin Control Digital

RAPID OIL TEST GAUGE

Contents. English 1. French 40. Spanish 81

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Instruction Manual. ph Meter D-51

TACH-10 Contact / Non-Contact Tachometer

MoistureMatch A next generation grain tester

Care and use guide. Contents. page

SIGNET 2750 ph/orp Sensor ENGLISH

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

SIGNET 3719 ph/orp Wet-Tap

Barnant Company (Type J) (Type K) (Type T)

Thermistor Thermometer MODEL NO

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

SAM990DW DIGITAL PSYCHROMETER GENERAL TOOLS & INSTRUMENTS USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Signet 3719 ph/orp Wet-Tap

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

i n s t r u c t i o n m a n u a l

GHMsilverline Handheld Instruments

ELECTRICAL. Moisture Meter User Guide

STP116 STP188. Tyre Pressure Monitoring System. User manual

Electrostatic Fieldmeter

Care and use guide Guía de uso y cuidado Guide d utilisation et d entretien.

OPERATING INSTRUCTIONS

Water Level Meter + Temperature

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

SPC Series. Digital Scale. Operation Manual

Bio Lion Table Top Centrifuge XC-H165

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

DigiTemp. Digital Thermometer

! Warning, refer to accompanying documents.

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

Dawson DDM190D. Digital Multimeter User s Manual

Transcription:

HI99181 Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using this meter. This manual will provide you with the necessary information for correct use of this meter, as well as a precise idea of its versatility. If you need additional technical information, do not hesitate to e mail us at tech@hannainst.com or view our worldwide contact list at www.hannainst.com. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA.

Table of Contents... 3 Preliminary Examination... 4 General Description and Intended Use... 5 Main Features... 6 Specifications... 7 Display Description... 8 Operational Guide... 8 Meter Setup... 14 Battery Replacement... 15 Accessories... 16 Electrode Maintenance... 17 Certification... 18 Recommendations for Users... 19 Warranty... 19 TABLE OF CONTENTS 3

4 PRELIMINARY EXAMINATION Remove the meter from the packing material and examine it carefully to make sure that no damage has occurred during shipment. If noticeable damage is evident, contact your local Hanna Instruments Office. Each meter is supplied complete with: HI14143/50 ph/temperature probe with flat tip, 50 mm-long body, DIN connector and 1m (3.3 ) cable ph 4.01 & 7.01 Buffer sachets HI700620 Cleaning and disinfection solution for skin residual (1 sachet) HI700621 Cleaning solution for skin grease and sebum (1 sachet) 100 ml beaker (1 pcs.) Alkaline batteries: 1.5V AAA (3 pcs.) Rugged carrying case Calibration certificate of meter Calibration certificate of probe Instruction manual Note: Save all packing material until you are sure that the meter functions correctly. All defective items must be returned in the original packing together with the supplied accessories.

HI99181 is a light weight, portable, ph and temperature meter supplied with a specially designed ph electrode intended for the direct determination of ph on skin and scalp. Researchers monitoring the compatibility between skin and cosmetics or pharmaceuticals use ph as essential marker of compatibility. The skin mantle has an acidic ph, ranging from ph 4 to 6. The acidic ph is a deterrent toward harmful microbes, pollution, and toxins. Age, genetics, sweat, and moisture can alter the ph of skin. Products are constantly created to restore the ph balance of skin and a reliable ph measurement of skin provides the scientific metrics. The HI99181 portable ph meter together with a HI14143/50 combination ph electrode (when immersed in a drop of water on the skin surface), can determine the ph of the skin with high accuracy and repeatability. The HI99181 features two button operation and is simple to use. The HI99181 has a waterproof and compact casing, large dual-line display, and automatic ph calibration at one or two points. The HI14143/50 offers numerous features that improve ph testing for skin measurements. The flat tip of the HI14143/50 provides optimal contact between the sample and the sensor. The HI14143/50 features low resistance ph glass that responds quickly to the sample. It also has an open junction design and utilizes a non-flowing gelled reference electrolyte so there is no variability in flow rate affecting the measurement. Both the ph sensing surface and reference junction come into intimate contact with the skin and equilibrate quickly and reproducibly. It also has a lower profile for easier handling compared to laboratory sensors; the glass body is just 50 mm in length. The HI14143/50 ph electrode has a built-in temperature sensor for temperature compensated ph and temperature readings and contains an integral ph sensor preamplifier to provide stable measurements in electrically noisy environments. GENERAL DESCRIPTION and INTENDED USE 5

MAIN FEATURES Main features: Simultaneous ph and temperature measurements on a large dual-line LCD display Automatic ph calibration at one or two points within two memorized buffer sets (standard or NIST) Selectable temperature unit ( C or F) Electrode condition indicator mv of ph measurement for electrode check HI14143/50 dedicated ph with integral temperature sensor Probe quick connect system Battery life indication and low battery detection Keystroke confirmation tone Auto-off function Waterproof casing IP67 6

Range* Resolution Accuracy @ 20 C / 68 F Temperature compensation ph Calibration Probe (included) Battery type / life Auto-Off Environment -2.00 to 16.00 ph / -2.0 to 16.0 ph ±825 mv (ph-mv) -5.0 to 105.0 C/23.0 to 221.0 F 0.01 ph / 0.1 ph 1 mv 0.1 C/0.1 F ±0.02 ph / ±0.1 ph ±1 mv (ph-mv) ±0.5 C up to 60 C; ±1.0 C outside ±1.0 F up to 140 F; ±2.0 F outside Automatic -5.0 to 105.0 C/23.0 to 221.0 F Automatic, 1 or 2 point selectable buffer set Standard: 4.01; 7.01; 10.01 or NIST: 4.01; 6.86; 9.18 HI14143/50 preamplified ph and temperature probe with flat tip 50 mm-long body, DIN connector and 1 m (3.3 ) cable 1.5V AAA (3 pcs.) approx. 1400 hours of continuous use user selectable: after 8 min, 60 min or disabled 0 to 50 C (32 to 122 F) RH max. 100% Meter Dimensions 154 x 63 x 30 mm (6.1 x 2.5 x 1.2 ) SPECIFICATIONS Meter Mass (with batteries) 196 g (6.91 oz.) Case Ingress Protection Rating IP67 * the HI14143/50 is limited to be used from 0 to 12 ph and from 0 to 50 C temperature (32 to 122 F). 7

DISPLAY DESCRIPTION 1 Automatic Temperature Compensation indicator 2 Stability indicator 3 Battery percentage 4 Electrode condition indicator 5 Low battery indicator 6 Measurement unit 7 Primary LCD 8 Temperature unit 9 Secondary LCD 10 Meter modes indicator 11 ph calibration buffer(s) used OPERATIONAL GUIDE Each meter is supplied with batteries. Before using the meter for the first time, open the battery compartment and insert batteries, observing the polarity (see Battery Replacement ). TO CONNECT THE ELECTRODE With the meter turned off, connect the HI14143/50 probe to the DIN socket on the bottom of the meter by aligning the pins and pushing in the plug firmly. Remove the protective cap from the probe before taking any measurements. 8

TO TURN THE METER ON To turn the meter ON, press the button on the front of the meter. If it does not turn on, make sure that the batteries are properly installed in their place. The meter is provided with an active acoustic signal when a key is pressed. At start-up the meter displays all LCD segments for a few seconds, followed by the percentage indication of the remaining battery life, the meter enters the normal measurement mode. OPERATIONAL GUIDE LCD check up Electrode check Battery life Measurement mode Note: The meter detects the presence and the type of the probe at its input. - If the probe is not connected the message NO PROBE appears alternatively on the secondary LCD with --- blinking on the first LCD line. - If the probe is not compatible WRONG PROBE message appears alternatively on the secondary LCD with --- blinking on the first LCD line. - If the readings are out of range, the nearest range limits are displayed blinking (E.g. -2.00 ph -5.0 C). TO SELECT THE MEASUREMENT RANGE While in measurement mode, press the SET button to select ph or ph-mv measurement on the first LCD line. 9

OPERATIONAL GUIDE TO FREEZE THE MEASUREMENT VALUES While in measurement mode, press and hold the SET button until HOLD appears on the secondary LCD. The HOLD remains for 1 second and reading of ph, mv and temperature will be frozen on the LCD with H blinking. Press any button to resume active measurements. TO ENTER CALIBRATION MODE Press and hold the button until POWER and tag is replaced by STD and tag. Release the button. TO ENTER SETUP MODE Press and hold button until STD and tag is replaced by SETUP and tag. Release the button. TO TURN THE METER OFF While in measurement mode, press the button. POWER and tag will appear. Release the button. ph MEASUREMENT & CALIBRATION Make sure the meter has been calibrated before use. If the probe is dry, soak it in HI70300 storage solution for 30 minutes to reactivate it. If fouled, clean the electrode by soaking in cleaning solution for 20 minutes, then rinse the tip and soak in storage solution at least 30 minutes before use. Rinse the electrode off well and shake off excess droplets. Recalibrate before using. Submerge the probe in the sample to be tested while stirring it gently. Wait until the tag on the LCD disappears. The LCD displays the ph value (automatically compensated for temperature) on the primary LCD, while the secondary LCD displays the sample temperature. 10

If measurements are taken in different samples successively, rinse the probe tip thoroughly to eliminate crosscontamination. For better accuracy, frequent calibration of the ph sensor with the meter is recommended. In addition, the meter must be recalibrated whenever: a) The ph electrode is replaced. b) After testing aggressive chemicals. c) Where high accuracy is required. d) At least once a month. e) After cleaning the sensor. The probe tip should be rinsed with purified water (reverse osmosis, distilled, or deionized) before and after placing in any solution (buffer, storage, or sample). ph calibration Enter calibration mode while in ph measurement mode. Place the sensor into the first calibration buffer. If performing a two-point calibration, use ph 7.01 (ph 6.86 for NIST) buffer first. The meter will enter the calibration mode, displaying ph 7.01 USE and tag blinking (or ph 6.86 USE for NIST). Follow directions for single and two-point calibration below: Single-point calibration 1. Place the probe in any buffer from the selected buffer set. The meter will automatically recognize the buffer value. 2. If the buffer is not recognized or the calibration offset is out of the accepted range ---- WRONG is displayed. 3. If the buffer is recognized REC is displayed then WAIT until the calibration is accepted. If using ph 7.01 (or ph 6.86 for NIST), after acceptance of the buffer press any key to exit. The SAVE message is displayed and the meter returns to ph measurement mode. If using ph 4.01 or 10.01 (or ph 9.18 for NIST) buffer the SAVE message is displayed and meter returns to ph measurement mode. OPERATIONAL GUIDE 11

OPERATIONAL GUIDE Two-point calibration Proceed with steps 1 through 3 under single point calibration using 7.01 (ph 6.86 for NIST) ph buffer first. Then follow steps below: The ph 4.01 USE message is then displayed. Place the probe in the second calibration buffer (ph 4.01 or 10.01, or, if using NIST, ph 4.01 or 9.18). When the second buffer is accepted, the LCD will display SAVE for 1 second and the meter will return to the normal measurement mode. If the buffer is not recognized or the slope is out of accepted range --- WRONG is displayed. Change the buffer, clean the electrode or press any key to exit calibration. It is always recommended to carry out a two-point calibration for better accuracy. When the calibration procedure is completed, the tag is turned on together with the calibrated points. To exit calibration and reset default values After entering the calibration mode and before the first point is accepted, it is possible to quit the procedure and return to the last calibration data by pressing the button. The LCD displays ESC for 1 second and the meter returns to normal mode. To reset the default values and clear a previous calibration, press the SET button after entering the calibration mode and before the first point is accepted. The LCD displays CLEAR for 1 second, the meter resets to the default calibration and the tag with the calibrated points on the LCD disappears. 12

ELECTRODE CONDITION The display is provided with a probe icon (unless the feature is disabled from setup) which indicates the electrode status after calibration. The condition remains active for 12 hours (unless the batteries are removed). The electrode condition is evaluated only if the current calibration has two points. 5 bars: excellent condition 4 bars: very good condition 3 bars: good condition 2 bars: fair condition 1 bar: poor condition 1 bar blinking: very poor condition With 1 bar it is recommended to clean the electrode and recalibrate. If there is still only 1 bar or 1 bar blinking replace the probe. Sensor Check Setting the meter to ph-mv range the user can check the sensor status at any time. The offset value is the reading in ph 7.01 buffer (@ 25 C/77 F). If this reading is outside the range ±30 mv, the electrode is considered very poor. The slope value of the sensor is the difference between readings in ph 7.01 and in ph 4.01 buffers. When the slope reaches the value of about 150 mv, the electrode is considered very poor. When poor or very poor, it is recommended to replace it with a new one. Note: To ensure reliable readings, the electrode must be cleaned with cleaning solution and then hydrated in storage solution for a minimum of 30 minutes before calibrating the probe. OPERATIONAL GUIDE 13

METER SETUP Setup mode allows the selection of the Temperature unit, Auto-off, Beep, the type of ph buffer set, the Resolution and Information. To enter Setup mode press and hold button until STD and tag is replaced by SETUP and tag. Release the button. TEMP is displayed on the secondary LCD with the current temperature unit (E.g. TEMP C ), for C/ F selection, use the SET button. After the temperature unit has been selected, press to confirm and to enter the A-OFF selection. Use the SET button, to cycle through the auto-off choices: 8 minutes ( 8, default value), 60 minutes ( 60 ) or disabled ( --- ). Press to confirm and to enter the BEEP selection. To switch ON or OFF the beep tone, press the SET button; press to confirm and to enter the calibration buffer selection ph 7.01 BUFF. To change the type of calibration buffer set, the meter will show the current buffer set: ph 7.01 BUFF (for standard buffer set: 4.01/7.01/ 10.01) or ph 6.86 BUFF (for NIST buffer set: 4.01/6.86/ 9.18). Change the set with the SET button. Press to confirm and to enter ph resolution selection RESOL. To change the ph measurement resolution between 0.1 and 0.01 use the SET button; then press to confirm and to enter electrode calibration information INFO selection. 14

To switch ON or OFF the electrode condition indicator on the LCD, press the SET button; press to exit setup options; Change the set with the SET button, then press to confirm and to return to normal mode. METER SETUP BATTERY REPLACEMENT When the remaining battery life is less than 10% the battery tag blinks on the display to warn the user. Battery Error Prevention System (BEPS) If the battery is too weak ( 0% ) the display shows batt, DEAD for few seconds then the meter power off. Immediately replace the batteries with new ones. The batteries are accessed by opening the battery cover on the back of the instrument. Remove protective boot if present. BATTERY REPLACEMENT 15

ACCESSORIES BATTERY REPLACEMENT Replace the three 1.5V AAA alkaline batteries located in the battery compartment, observing the indicated polarity. Replace the battery cover making sure that the gasket is in place. HI14143/50 HI7004L HI7006L HI7007L HI7009L HI7010L HI70300L HI7061L HI70620L HI70621L HI710029 HI76405 HI77400P Preamplified ph/temperature probe with flat tip 50 mm-long body, DIN connector and 1 m (3.3 ) cable ph 4.01 buffer solution, 500 ml ph 6.86 buffer solution, 500 ml ph 7.01 buffer solution, 500 ml ph 9.18 buffer solution, 500 ml ph 10.01 buffer solution, 500 ml ph electrode storage solution, 500 ml ph electrode cleaning solution, 500 ml Cleaning and disinfection solution for skin residual, 500 ml Cleaning solution for skin grease and sebum, 500 ml Silicon rubber boot blue color Electrode holder Calibration kit (ph 4 & 7, 20 ml, 5 pcs. each) 16

Code and serial number on the other side ACCESSORIES Temperature sensor junction reference ph sensor Quick connector with Rubber protection, and 1 meter cable PREPARATION Remove the protective cap. DO NOT BE ALARMED IF ANY SALT DEPOSITS ARE PRESENT. Rinse with water. Shake the electrode down as you would do with a clinical thermometer to eliminate any air bubbles inside the glass. If the glass and/or junction are dry, soak the electrode in HI70300 Storage Solution for a minimum of 30 minutes. Rinse with water. Calibrate before using. STORAGE To ensure a quick response, the glass and the junction should be kept moist and not allowed to dry. Replace protective cap with a few drops of HI70300 Storage Solution. Follow PREPARATION above before taking measurements. Note: NEVER STORE THE ELECTRODE IN DISTILLED WATER. ELECTRODE MAINTENANCE 17

CERTIFICATION ELECTRODE MAINTENANCE PERIODIC MAINTENANCE Inspect the electrode for any scratches or cracks. If any present, replace the electrode. Rinse off any salt deposits with water. Follow the STORAGE procedure above. CLEANING PROCEDURE Soak in Hanna HI7061 general cleaning solution, HI700620 cleaning and disinfection solution for skin residual or HI700621 cleaning solution for skin grease and sebum for 20 minutes. Rinse with water. IMPORTANT: After performing any of the cleaning procedures rinse the electrode thoroughly with distilled water. Soak the electrode in HI70300 Storage Solution for a minimum of 30 minutes. Rinse with water. Calibrate before using. TROUBLESHOOTING ph Meter: Follow the meter s operating and calibration procedures. Electrode: Evaluate your electrode performance based on the SENSOR CHECK procedure on page 13. All Hanna Instruments conform to the CE European Directives. RoHS compliant Disposal of Electrical & Electronic Equipment. The product should not be treated as household waste. Instead hand it over to the appropriate collection point for the recycling of electrical and electronic equipment which will conserve natural resources. Disposal of waste batteries. This product contains batteries, do not dispose of them with other household waste. Hand them over to the appropriate collection point for recycling. Ensuring proper product and battery disposal prevents potential negative consequences for the environment and human health. For more information, contact your city, your local household waste disposal service, the place of purchase or go to www.hannainst.com. MAN99181 05/18 18

Recommendations for Users Before using this product, make sure it is entirely suitable for your specific application and for the environment in which it is used. Any variation introduced by the user to the supplied equipment may degrade the meters performance. For yours and the meter s safety do not use or store the meter in hazardous environments. Warranty HI99181 is warranted for two years against defects in workmanship and materials when used for its intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna Instruments Office. If under warranty, report the model number, date of purchase, serial number (see engraved in the back of the meter) and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the meter is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization number from the Technical Service department and then send it with shipping costs prepaid. When shipping any meter, make sure it is properly packed for complete protection. Hanna Instruments reserves the right to modify the design, construction or appearance of its products without advance notice. 19

World Headquarters Hanna Instruments Inc. Highland Industrial Park 584 Park East Drive Woonsocket, RI 02895 USA www.hannainst.com Local Office Hanna Instruments Inc. 270 George Washington Highway Smithfield, RI 02917 Phone: 800.426.6287 Fax: 401.765.7575 e-mail: tech@hannainst.com MAN99181 Printed in ROMANIA