Stress/Strain Apparatus AP-8214

Similar documents
Rotary Motion Sensor

ROTARY MOTION SENSOR FOR ULI

COMPUTER-BASED THERMAL EXPANSION APPARATUS

Physics Labs with Computers, Vol. 1 P29: Electrostatic Charge A

Driven Damped Harmonic Oscillations

Instruction Manual A * * High School Physics Structures Set ME-7000

APHY 112 EXPERIMENT 1: ELECTROSTATIC CHARGE

Driven Damped Harmonic Oscillations

University of TN Chattanooga Physics 1040L 8/28/2012

Faraday's Law of Induction

Heat Engines Lab 12 SAFETY

Dynamics Cart Accessory Track Set (1.2m version)

Activity P58: Magnetic Field of a Solenoid (Magnetic Field Sensor, Power Amplifier)

Evaluation copy. The Magnetic Field in a Slinky. computer OBJECTIVES MATERIALS INITIAL SETUP

Dynamics Cart Accessory Track Set (2.2m version)

The Magnetic Field. Magnetic fields generated by current-carrying wires

CURRENT BALANCE CAUTION

The Magnetic Field in a Slinky

Lab 4 Heat Engine. Objective The objective of this lab is to build a heat engine, to operate it, and to measure its efficiency.

Motions and Forces Propeller

User Manual. Aarhus University School of Engineering. Windtunnel Balance

Voltage and Current in Simple Circuits (Voltage Sensor, Current Sensor)

The Magnetic Field in a Coil. Evaluation copy. Figure 1. square or circular frame Vernier computer interface momentary-contact switch

PHYS 2212L - Principles of Physics Laboratory II

o applied to the motor., 0, and Vo

Concepts of One Dimensional Kinematics Activity Purpose

Faraday's Law of Induction

Impulse, Momentum, and Energy Procedure

G.U.N.T. Gerätebau GmbH

Newton s 2 nd Law Activity

Introduction. Figure 1: Labeled picture of the Instron 3367 load frame.

Lab #3 - Slider-Crank Lab

AR2000 Rheometer: Instructions

Momentum, Energy and Collisions

Air Fuel Ratio Module and AFR-4 Pump Assembly Installation and User Guide.

Figure 1: (a) cables with alligator clips and (b) cables with banana plugs.

Re-Energy.ca - Solar Electricity - Build Your Own Solar Car

Theory of Machines II EngM323 Laboratory User's manual Version I

Lab 4 Constant Acceleration by Drew Von Maluski

Newton s First Law. Evaluation copy. Vernier data-collection interface

Control Gate Valve with stepper motor actuator

Throttle Quadrant Operating Manual English Version

Data Sheet. Motorized Test Stand w/pc Control ESM303H. Standard Features. Page 1 of 5

ME scope Application Note 24 Choosing Reference DOFs for a Modal Test

Micro Tensile Tester User Manual

Radiant High Voltage. Displacement Measurement Fixture. Construction. Introduction. Figure 1

Bench Top Tube Bender

Using Advanced Limit Line Features

Data Sheet. Motorized Test Stand w/pc Control ESM303

Exercise 2-1. The Separately-Excited DC Motor N S EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Simplified equivalent circuit of a dc motor

Vernier Rotary Motion Sensor

Lab 2 Electrical Measurements and Ohm s Law

Rheometer Calibration Fixture Instruction Manual Model 280 & 286

EL Beam Sensors Standard & SC Versions

Bruce s Science workbench

Resistivity. Equipment

Dynojet Research, Inc. All Rights Reserved. Air Fuel Ratio Module Installation and User Guide.

Chapter 7. Magnetic Fields. 7.1 Purpose. 7.2 Introduction

VW Arc-Weldable Strain Gauge

When you finish the running, power off the receiver BEFORE turning off the transmitter.

Bistable Rotary Solenoid

L-16 Crank-Up Lift Instruction & Operation Manual 2012

Moments. It doesn t fall because of the presence of a counter balance weight on the right-hand side. The boom is therefore balanced.

Conductor Strength Tests on ACCR 1622TW T13 Pecos Conductor

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine


Vernier Dynamics Cart and Track System (Order Code DTS)

Transmission Error in Screw Compressor Rotors

Visualizing Rod Design and Diagnostics

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

Bag 1. Bag 1. Center Pivot. Center Pivot

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Self-Adjusting Clutch (SAC) Technology Special tools / User instructions

2 Dynamics Track User s Guide: 06/10/2014

Wind Tunnel User Guide V0814

Operating Efficiency of Crankshaft Drive Pumps

Electrostatic Charging

401B/1KDB CoolRite/FreezeRite Installation Manual I003

Making Instructions Version 2.1 for Windows

OPERATION AND MAINTENANCE

Installation Instructions Table of Contents

Customer Name. Instruction for Operation. Single Head Sleever

Application of ABAQUS to Analyzing Shrink Fitting Process of Semi Built-up Type Marine Engine Crankshaft

Written By: David Hodson

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439

34.5 Electric Current: Ohm s Law OHM, OHM ON THE RANGE. Purpose. Required Equipment and Supplies. Discussion. Procedure

Experiment 6: Induction

FlowScanner 6000 SGIM-1 and SGIM-2 Strain Gauge Interfaces

JK 1.5 Spring Lift Part #

Mettler Analytical Balance AE240 Dual Range Balance

ATS-9600/9700 TABBER/LABELER

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

Rimac Spring Tester Retro-Fit Kit

Safety Considerations

HOME OF PRIMO BELT DRIVES QUALITY & PERFORMANCE SINCE 1973 BRUTE FORCE TM. Belt Drive INSTALLATION INSTRUCTIONS

DRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual

ATS-9600/9700 TABBER/LABELER

2017 MATE ROV COMPETITION: NAVIGATOR CLASS PREVIEW MISSION

CPi. CoiL PACK IGNiTioN FOR AViATiON. For 4,6 and 8 cylinder 4 stroke applications. Please read the entire manual before beginning installation.

The Effect of Wheel Loading on a Railway Bridge: A Case Study on Minnamurra Railway Bridge

Transcription:

Instruction Manual 012-09424B Stress/Strain Apparatus AP-8214 C D E F G B ( 7) H A I Included Equipment Part Number A. Stress/Strain Apparatus AP-8214 B. Test Coupons, 10 pieces each sample (sample containers labeled with thickness in inches) cold-rolled steel annealed steel aluminum polyethylene terepthalate plastic polycarbonate brass (thick) brass (thin) AP-8217 C. Storage Box 650-061 D. Attachment for force sensor 003-07916 E. Thumbscrews for Rotary Motion Sensor, 2 pieces 617-031 F. Tee handle 726-049 G. 3/8 inch socket 726-050 H. Calibration bar 648-07650 I. Experiment set-up CD-ROM 013-08999 800-772-8700 www.pasco.com

Stress/Strain Apparatus Introduction Additional Equipment Required for Use with ScienceWorkshop Sensors ScienceWorkshop Interface (500, 700, or 750) DataStudio 1 Economy Force Sensor Rotary Motion Sensor Additional Equipment Required for Use with PASPORT Sensors PASPORT Interface 2 DataStudio 1 Force Sensor Rotary Motion Sensor Part Number CI-6400, CI-6450 or similar See PASCO catalog or www.pasco.com CI-6746 CI-6538 Part Number See PASCO catalog or www.pasco.com See PASCO catalog or www.pasco.com PS-2104 PS-2120 1 DataStudio 1.8 or later recommended. Visit www.pasco.com to download the latest version. DataStudio Lite, the free version, is sufficient for use with the included experiment set-up files. 2 Apparatus requires a single multi-port interface such as Xplorer GLX (PS-2002) or PowerLink (PS-2001), or two single-port interfaces such as USB Link (PS-2100) or Xplorer (PS-2000). Introduction The PASCO AP-8214 Stress/Strain Apparatus illustrates the relationship between stress and strain for various materials. The apparatus stretches a test coupon (and in some cases breaks it) while measuring the amount of stretch and force experienced by the test coupon. Software is used to generate a plot of stress versus strain. The Stress/Strain Apparatus requires a ScienceWorkshop or PASPORT interface, DataStudio software, a Rotary Motion Sensor (RMS), and a Force Sensor. Included with the apparatus are test coupons of various materials and thicknesses, a tee handle with socket for mounting the test coupons, and a bar for calibrating the apparatus. This manual includes instructions for calibration and data collection using the DataStudio set-up files on the CD-ROM. As an alternative to this manual, the CD-ROM also include a DataStudio workbook designed for use without the printed instructions. Open Elasticity SW.ds (for ScienceWorkshop) or Elasticity PS.ds (for PASPORT) and follow the on-screen instructions. 2

Model No. AP-8214 Equipment Set-up 10 11 2 3 4 1 6 7 9 9 1. Rotary Motion Sensor (RMS) 2. Force Sensor 3. Force Sensor attachment 4. setscrew 5. Stress Strain platform 6. 3-step pulley 7. belt 5 8. groove 9. coupon clamps 10. lever arm 11. thumbscrew 8 Figure 1: Equipment Set-up Equipment Set-up 1. Attach the RMS to the apparatus platform. a. Remove the rod clamp from the RMS. b. Place the three-step pulley onto the shaft of the RMS with the largest pulley out. The three-step pulley should be on the clockwise positive side of the RMS as illustrated (Figure 2). c. Place the RMS on the platform as illustrated (Figure 1). Use the two thumbscrews to fasten the RMS to the platform from beneath. d. Seat the belt on the middle step of the three-step pulley and the groove on the crankshaft. 2. Attach the Force Sensor to the apparatus platform. ScienceWorkshop a. Remove the hook from the Force Sensor and replace it with the force sensor attachment. b. Place the Force Sensor on the apparatus platform by inserting the post through the support rod mount of the Force Sensor. c. Insert the long thumbscrew supplied with the Force Sensor through the hole on the Force Sensor marked Cart and screw it into the tapped hole in the apparatus platform. d. Tighten the setscrew in the support rod mount of the Force Sensor. 3. Clamp down the apparatus (optional). Use a large C-clamp to clamp the Apparatus Platform to the edge of your bench or table. One side of the platform has three feet. In order to avoid bending the platform, position the clamp directly over the center foot. PASPORT Figure 2: Three-step pulley on the clockwise positive side of RMS 3

Stress/Strain Apparatus Apparatus Calibration 4. Plug the sensors into the interface. ScienceWorkshop interface: Connect the Force Sensor to Channel A. Connect the yellow plug of the RMS to Channel 1 and the black plug to Channel 2. PASPORT interface: Connect the Force and Motion sensors to a multi-port interface or two single-port interfaces. 5. Prepare DataStudio. Start DataStudio and open the activity file Stress Strain SW.ds (for ScienceWorkshop) or Stress Strain PS.ds (for PASPORT) located on the included CD-ROM. Apparatus Calibration During the experiment, as you turn the crank, force will be applied to the test coupon causing it to stretch. However, this force will also cause the apparatus platform and the Force Sensor to bend. The displacement registered by the RMS will be the combination of the coupon stretching and the rest of the apparatus bending. Regardless of how much the coupon stretches, the deformation of the rest of the apparatus is constant for a given force. You can measure this deformation directly by using the calibration bar (which does not stretch significantly) in place of a coupon. In the resulting Displacement versus Force graph, the displacement is due only to bending of the apparatus. Later, you will subtract this calibration plot from a similar plot made with a coupon, in which the displacement results from both bending of the apparatus and stretching of the coupon. The difference will be a plot in which the displacement is due only to stretching of the coupon. Follow these steps to acquire calibration data: 1. Install the Calibration Bar. a. Remove the nuts and clips from the apparatus platform (Figure 3). b. Turn the crank to adjust the position of the bolts and slip the bolts through the holes in the calibration bar. Do not replace the nuts when using the calibration bar. 2. Place the lever arm in the starting position. Turn the crank counter-clockwise and pull the lever arm away from the Force Sensor (Figure 4). 3. Plot Position versus Force. a. Press the Tare or Zero button on the Force Sensor. b. Click the Start button. c. Turn the crank clockwise. Starting just before the lever arm comes into contact with the Force Sensor, turn the crank very slowly. DataStudio will start recording when the force applied to the coupon reaches 2.5 N, or 1% of maximum (as shown in the % Max Force digits display). d. Continue to turn the crank until the force reaches 100% of maximum. At this point, DataStudio will stop recording automatically. e. Change the name of the data run containing the calibration data to Cal.* * To rename a data run, click the run name (e.g. Run #1 ) where it appears in the Data List. Wait about 1 second then click it again. Enter the new name. A dialog box will appear. Select Yes. (If a window titled Data Properties appears, you didn't wait long enough after the first click; close that window and try again.) 4

Model No. AP-8214 DataStudio Set-up Figure 3: Calibration Bar Set-up Figure 4: Start Position DataStudio Set-up 1. Prepare the calculation for Calibrated Position. In the Calculator window, define the variables for the Calibrated Displacement(F) calculation: a. Drag Displacement(t) vs Coupon Force(t) (mm) to Please define variable Displacement. (Figure 5) b. Drag Cal to Please define variable Cal. (DataStudio will display a warning box stating that a single run is selected. Click the Yes button in that box.) Figure 5: Define Variables in Calculator 5

Stress/Strain Apparatus Data collection 2. Prepare the calculation for Stress. In the Calculator window, select the defined function Stress(F) = Force/Area. In the Variables section, enter the cross-sectional Area of the coupon in square millimeters. 3. Prepare the calculation for Strain. In the Calculator window, select the defined function Strain(F) = Displacement/Length. In the Variables section, enter the Length of the narrow part of the coupon in millimeters. 4. Close the Calculator window. You now have a the characteristic baseline curve for your particular apparatus. You can save the file and use it as the starting point for future experiments instead of repeating the calibration. Data collection 1. Mount a coupon. a. Remove the calibration bar and restore the clips and nuts. b. Place one end of the coupon under one of the clips. c. Adjust the crank so that the opposite end of the coupon can slip easily under the other clip (Figure 6). d. Tighten both nuts with the tee handle with socket. With no force applied to the coupon, as little twist as possible should be visible in the coupon. The clips should hold the coupon tightly enough that it will not slip when force is applied. However, over-tightening the nuts will damage the bolts. If in doubt, err on the side of under-tightening. Figure 6: Coupon Installed 2. Place the lever arm in the starting position. Turn the crank counter-clockwise and pull the lever arm away from the Force Sensor (Figure 4). 3. Collect Data. a. Press the Tare or Zero button on the Force Sensor. b. Click the Start button. c. Turn the crank clockwise. Starting just before the lever arm comes into contact with the Force sensor, turn the crank very slowly.* * When you observe on the Stress versus Strain plot that the material has been stretched beyond the elastic region, you can begin to turn the crank faster. 6

Model No. AP-8214 Data Analysis d. When you have finished collecting data, click Stop. (If you reach the maximum force, DataStudio will stop automatically.) If the coupon breaks, it should break in the middle. If the coupon breaks near the end, it was probably twisted slightly when you mounted it, resulting in a point of higher stress where it broke. 4. Rename the data run to identify the coupon. Use the same method you used to rename the calibration data. Data Analysis On the Stress versus Strain graph, you can identify features such as the elastic region, the plastic region, the yield point, and the break point. To calculate Young's modulus, drag the mouse to select a data region covering the linear, lower left-hand part of the graph. (You may find that the very first part of the plot is not linear. This nonlinearity is likely due to the straightening of bends and twists in the coupon as force is first applied. Do not include this region in your selection.) Click the Fit button to apply a linear curve fit to the selected data. The slope of the line is Young's modulus in units of MPa (or MN/m2 or N/mm2). Notes on the DataStudio Setup File For comparison of different materials, you can collect additional data runs with other coupons. Note that the Stress calculation applies only to coupons of the thickness that you entered in the Calculator window. It is easiest to compare coupons of the same thickness. However, to simultaneously display stress versus strain plots for coupons of different thicknesses, you must create a separate Stress calculation for each thickness. Copy the existing Stress calculation exactly (including the calculation properties), but give it a unique name (indicating the thickness for which it is designed) and enter the applicable cross-section area for the Area constant. When you create a new Stress calculation, note that there are two different calculations for Coupon Force- Coupon Force(F) and Coupon Force(t). Always use Coupon Force(F). The (F) identifies data as a function of Force, and (t) as a function of time. DataStudio records data as a function of time, but this experiment requires data to be recast as a function of Force. Whenever you create a new calculation or graph, be certain to use only data that is a function of Force. When you add a new Stress calculation to the graph, it will initially appear with time on the horizontal axis. Click the word time and select Strain instead. 7

Stress/Strain Apparatus Sample Data Sample Data Sample 1: displacement vs. force - brass.003 and.005 Sample 2: stress vs. strain - aluminum.003. Units of slope are MPa Technical Support For assistance with any PASCO product, contact PASCO at: Address: Phone: PASCO scientific 10101 Foothills Blvd. Roseville, CA 95747-7100 916-786-3800 (worldwide) 800-772-8700 (U.S) Fax: (916) 786-3292 Web: www.pasco.com Email: techsupp@pasco.com Limited Warranty For a description of the product warranty, see the PASCO catalog. Copyright The PASCO scientific 012-09424B Stress/Strain Apparatus Instruction Manual is copyrighted with all rights reserved. Permission is granted to non-profit educational institutions for reproduction of any part of this manual, providing the reproductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under any other circumstances, without the written consent of PASCO scientific, is prohibited. Trademarks PASCO, PASCO scientific, DataStudio, PASPORT, and ScienceWorkshop are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of, their respective owners. For more information visit www.pasco.com/legal. 8