G96 Series BASOTROL Dual Operator Valve

Similar documents
G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

BGD278 Series BASOTROL CE Approved Gas Valve

BGD258 Series BASOTROL CE Approved Class A Gas Valve

H15 Series BASO Automatic Shutoff Pilot Gas Valve

H15 Series BASO Automatic Shutoff Pilot Gas Valve

Y75 Series Sensing Probes

Y75 and D Series Sensing Probes

J Series Pilot Burners/Y90 Series Inlet Fittings

B21 Series BASOTROL Gas Valve

G76x Direct Spark Ignition Controls

G72x Series Direct Spark Ignition Controls

BG1600M Intermittent Pilot Ignition Control

G600 Series Replacement Intermittent Pilot Ignition Controls

G861 Series Integrated Function. Direct Spark Ignition Control

GEMINI GAS CONTROL PRODUCT INFORMATION

Electrically Operated. Gas Valves. Thermocouple Operated. Gas Valves Accessories Ignition Control Modules Pilot Burners PRODUCT CATALOG 2017

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

Q35 Series Automatic Vent Damper System

GV30 / GV30A SERIES GAS COMBINATION CONTROL SYSTEMS FOR COMMERCIAL COOKING APPLIANCES.

Series 20 Installation Instructions

36H Gas Control Product Information

CATALOG. 2 nd Edition

P70, P72 and P170 Series Controls for High Pressure Applications

BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

P66 Series Electronic Fan Speed Controls

Eclipse RatioAir Burners

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

P70, P72, and P170 Controls for Low Pressure Applications

Service and installation must be performed by a trained/experienced service technician.

Series Y63, Y64, Y65, Y66, and Y69 Transformers

36C and 36D Gas Control Product Information

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

AV-8020 Series Floating Control Actuated Valve

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc.

E Series CE Approved Intermittent Pilot Ignition Control

Eclipse RatioAir Burners

VA-8020 Floating Valve Actuator

VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators

P70, P72, and P170 Series Controls for High Pressure Applications

Service and installation must be performed by a trained/experienced service technician.

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

Power Flame Incorporated

V5197A Firing Rate Gas Valve

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

Rheem Classic Plus Series Downflow Gas Furnace

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

SD-1250 and SD-1600 Series Smoke Dampers

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

System 350 P352AB Electronic Pressure Control Series

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Rheem Classic Series Upflow/Horizontal Gas Furnace

Electro- Hydraulic Actuator Gas Valves GH-5000

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

2-Way/2 Position Valves

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Rheem Classic Series Upflow/Horizontal Gas Furnace

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

INSTALLATION INSTRUCTIONS FOR PCBM-36C CONVERSION KIT From Natural Gas to Propane/LP Gas

F61 Series Standard Flow Switches

Data /1/07 Eclipse RatioAir Burners Model RA0040

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

Cooling Capacity CFM in. w.c. (125 Pa)

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

Natural Gas Reference Guide

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces

Series 44 Installation Instructions

Table of Contents GF801U Series

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

10 S e r i e s PRESSURE SWITCH. features

f i r e - p a r t s. c o m

Rheem Value Series Downflow Gas Furnace

F261 Series Fluid Flow Switches

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Flare Valves 1/2 inch 2-Way and 3-Way

Electrical Specifications 24 VAC 60 Hz, 110/120, 220/240 VAC 50/60 Hz 12, 24, 36 VDC 11W Continuous 30W Intermittent

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION

Rheem Classic Series Downflow Gas Furnace

A25 Series Warm Air Control with Manual Reset

B42 Series Regulator Residential Regulator

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

S21 Series. - 1" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

Transcription:

Product Bulletin Issue Date March 5, 2013 G96 Series BASOTROL Dual Operator Valve The G96 Series BASOTROL valves are combination, dual operator, automatic valves available with or without a pressure regulator. Typical applications include central heating units, unit heaters, rooftop units, make up air heaters, and similar applications. Figure 1: G96 Dual Operator Gas Valve Features and Benefits Bipolar Magnetic Operator Top or Bottom Regulation Adjustment Compact Design Selectable Pilot Tap Positions Numerous Magnetic Operator Cover Styles Available Optional Valve-Mounted Ignition (BGQ) Provides dependable operation and long life Provides application flexibility Permits installation in dimensionally restricted applications Provides application flexibility Allows various mounting options and connection choices to best suit your requirements Lowers assembly costs and simplifies wiring 2013 BASO Gas Products 1 Code No. BASO-PB-G96, Rev. C www.baso.com

Product Overview Application The G96 Valves are suitable for use with natural gas or Liquefied Petroleum (LP) gas at pressures up to 0.5 psi (35 mbar [3.5 kpa]). The G96 valves with a silicone diaphragm are suitable for operation over a temperature range of -40 to 175ºF (-40 to 79ºC). Valves with a nitrile diaphragm are suitable for operation over a temperature range of -20 to 175ºF (-29 to 79ºC). Note: This valve should be used only in applications that are within the limitations and provisions of the applicable American National and/or Underwriters Laboratories standards. Description The G96 valve is equipped with two BASOTROL bipolar magnetic operators. Bipolar construction reduces the possibility of the valve sticking in the open position from residual magnetism or from mechanical interference. A leak limit orifice is supplied as standard on valves with a regulator stack. Valves can be constructed in one of the following two constructions. Indirect Burner Ignition The indirect burner ignition construction offers redundant main gas shutoff as the pilot and main gas operators are in series. This construction is for use with intermittent pilot ignition systems. Direct Burner Ignition The direct burner ignition construction offers redundant automatic main gas shutoff. Both valves are energized and de-energized simultaneously. This construction is for use with direct spark or hot surface ignition systems. Valve Constructions The G96 series is available with 1/2 x 1/2 in. or 1/2 x 3/4 in. body connections with 25, 120, or 240 VAC 2-wire magnetic operators. Refer to the Ordering Information section for more information. Additionally, the G96 series is available with other optional configurations. Pressure Connections The G96 valve is available with 1/8-27 NPT pressure taps when required. Contact BASO Gas Products for details and ordering. Magnetic Operator Cover Styles An aluminum magnetic operator cover with conduit hub and 30 in. (762 mm), 18 American Wire Gauge (AWG) stranded lead wires are supplied as standard on all line voltage models. The leads and hub position may be located at the top, over the inlet, on the right side, or on the left side of the valve. Lead wires with 1/4 in. (6.35 mm) quick-connect terminals are also available. The Underwriters Laboratories (UL), Inc. Listed steel operator cover is available with a top conduit hub only. A plastic magnetic operator cover with 1/4 in. (6.35 mm) quick-connect male terminals is supplied as standard on all low-voltage models. However, an aluminum or steel operator cover with conduit hub is available. Contact BASO Gas Products for details and ordering of magnetic operator cover style and wiring requirements. /Pilot Tap Options The G96 is designed for various configurations. The top adjust or bottom adjust regulator, and right- or left-hand pilot tap options take advantage of space access limitations. Mounting The G96 valves may be mounted on a horizontal manifold with the magnetic operators pointed up (vertical) or in a position not exceeding 90º from vertical. The G96 also may be mounted on a vertical manifold in any position around its axis. 90º 90º Horizontal mounting limited to 90º from upright. Vertical mounting may be 360º around its axis with the gas flow either up or down, but always in the direction of the arrow. Figure 2: Mounting Positions 2 G96 Series BASOTROL Dual Operator Valve Product Bulletin

Magnetic Operators Burner Manual Shutoff Valve Intermittent Pilot Ignition Control Direct Spark Ignition Control Pilot Valve Main Valve Common Connection Connection Connection Main Valve Connection Common Connection Figure 3: Typical G96 Installation and Wiring Dimensions D Inlet B No Top Adjust C C C Outlet F F E A Top Adjust or No Figure 4: Dimensions Table 1: Dimensions Series A B C D E F Number in. mm in. mm in. mm in. mm in. mm in. mm G96 without a G96 with Top Adjust G96 with 4.23 107 2.44 62 1.28 33 0.41 10 1.33 34 1.33 34 4.23 107 2.44 62 1.66 42 0.41 10 1.33 34 2.10 53 4.23 107 2.44 62 2.48 63 0.41 10 1.33 34 1.33 34 G96 Series BASOTROL Dual Operator Valve Product Bulletin 3

Range of Regulation Table 2: Range of Regulation Inlet/Outlet Q MINIMUM Q MAXIMUM in. NPT cf/h m 3 /h cf/h m 3 /h 1/2 x 1/2 20 0.57 200 5.7 1/2 x 3/4 20 0.57 250 7.1 Note: 1 m 3 /h = 10.67 kw (cf/h - 1,000 Btu/hr) natural gas at 0.64 specific gravity. For LP flow rates, see Figure 5. Ordering Information G 9 6 _ - Customer-specific Requirements C = H = K = Q = Type Top Adjust: 3 to 6 in. W.C. (7.5 to 15 mbar [0.75 to 1.5 kpa]) Top Adjust: 6 to 12 in. W.C. (15 to 30 mbar [1.5 to 3.0 kpa]) : 3 to 6 in. W.C. (7.5 to 15 mbar [0.75 to 1.5 kpa]) : 8 to 12 in. W.C. (20 to 30 mbar [2.0 to 3.0 kpa]) None Gas Flow B = G = Voltage 120V, 60 Hz 240V, 60 Hz 25V, 60 Hz H = J = *S = Natural Gas Capacity @ 1 in. W.C. (2.5 mbar [0.25 kpa]) Pressure Drop Btu/hr kw *Not CSA Recognized Inlet/Outlet 1/2 x 1/2 in. NPT 1/2 x 1/2 in. NPT 1/2 x 3/4 in. NPT 1/2 x 1/2 Rp The presence of a particular construction in this information does not guarantee its availability. Consult BASO Gas Products for available constructions. Figure 5: Ordering Matrix 4 G96 Series BASOTROL Dual Operator Valve Product Bulletin

Technical Specifications Product Rated Inlet Pressure Permissible Ambient (Surface) Temperature Available Magnetic Operator Cover Styles Electrical Rating Adjustment Range Inlet Pipe Size Outlet Pipe Size Pilot Outlet Wiring Connections Types of Gas G96 Series BASOTROL Dual Operator Valve 0.5 psi (35 mbar [3.5 kpa]) -20 to 175 F (-29 to 79 C) nitrile diaphragm -40 to 175 F (-40 to 79 C) silicone diaphragm Aluminum side conduit hub Aluminum top conduit hub Aluminum top without conduit hub Aluminum side outlet with eyelet Steel top conduit hub Plastic with 1/4 in. (6.35 mm) male quick-connect terminals 25 VAC, 60 Hz, 0.3 ampere draw for each operator 120 VAC, 60 Hz, 0.05 ampere draw for each operator 240 VAC, 60 Hz, 0.03 ampere draw for each operator s: Top Adjust s: 1/2 in. NPT 1/2 or 3/4 in. NPT 1/8 in. NPT, 1/4 in. cc also available 3 to 6 in. W.C. (7.5 to 15 mbar [0.75 to 1.5 kpa]) 8 to 12 in. W.C. (20 to 30 mbar [2.0 to 3.0 kpa]) 3 to 6 in. W.C. (7.5 to 15 mbar [0.75 to 1.5 kpa]) 6 to 12 in. W.C. (15 to 30 mbar [1.5 to 3.0 kpa]) 1/4 in. (6.35 mm) male quick-connect or 30 in. (762 mm) lead wires (other lengths are optional) Natural or Liquefied Petroleum (LP) Accessories Conversion Kits Natural Gas to LP Gas: Packaging Bulk Pack Quantity Bulk Pack Weight LP Gas to Natural Gas: Non-Regulation: Top Adjust Top Adjust Top or Bulk pack supplied to original equipment manufacturer (individual pack optional). 32 per carton (G96HGA and G96JGA bulk pack quantity is 20 per carton) 49 lb (22 kg) per carton (G96HGA and G96JGA weight is 30 lb [14 kg] per carton) Y71GF-4 Y71GF-3 Y71QH-2 Y71QH-3 Y71AA-5 Agency Listings CSA Certificate Number 229521-16041 (excludes G96SHA) Australian Gas Association Certificate Number 3495 (top adjust models only [excludes G96HAC and G96HBA]) AGA Adjustable, Class 2, Grade 20; Automatic Class 3 Specifications Standards ANSI Z21.21, CSA 6.5 ANSI Z21.78, CSA 6.20 AS 4624 Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or misuse of its products. Refer to the G96 Series BASOTROL Dual Operator Valve Installation Instructions (BASO-INS-G96) for necessary information on the installation, use, and servicing of this product. 1007 South 12th Street PO Box 170 Watertown, WI 53094 www.baso.com 1-877-227-6427 (1-877-BASOGAS) Printed in U.S.A. G96 Series BASOTROL Dual Operator Valve Product Bulletin 5