I N S T R U C T I O N M A N U A L

Similar documents
OVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)

OVAL GEAR Medium capacity positive displacement Mechanical flowmeters. Model: ½ (15m m)

OVAL GEAR. Medium Capacity Positive Displacement Mechanical Flowmeters. Models: 1 (D-150), 1½ (D-250), 2 (D-450) & 2" (D-580)

OVAL GEAR. Medium capacity positive displacement Pulse flowmeters I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L 3 (080), 3 (080E), 4 (100), & 4 (100E)

I N S T R U C T I O N M A N U A L

OVAL GEAR Medium capacity positive displacement flowmeter

OVAL GEAR Medium capacity positive displacement flowmeters

OVAL GEAR Medium capacity positive displacement pulse flowmeter. Size : ½ ( 015mm)

I N S T R U C T I O N M A N U A L

MULTIPULSE PISTON POSITIVE DISPLACEMENT FLOWMETER

POSITIVE DISPLACEMENT FLOWMETER I N S T R U C T I O N M A N U A L

MULTIPULSE PISTON POSITIVE DISPLACEMENT FLOWMETER

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Positive displacement flowmeter for continuous flow measurement

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

POSITIVE DISPLACEMENT FLOWMETER

Operating Instructions for Oval Wheel Flowmeter. Model: DOE

Positive Displacement Flowmeters GM020 series instruction manual

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

POSITIVE DISPLACEMENT FLOWMETERS

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

Positive displacement flowmeter

MODEL 1100 TURBINE FLOW METER

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

macnaught flow measurement

Positive Displacement Flowmeters GM515 series instruction manual

Positive Displacement Flowmeters GM007 series instruction manual

The experts in fluid technology

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

Discussed in this chapter are

MODEL 900 IMPELLER-TYPE FLOW METER

Technical Data. Series Oval Flowmeter. Model 9400

Positive displacement batch controller

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models:

Ph: (07) Fax: (07) Pump Manual

Inline Ultrasonic Flowmeter

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

INSTRUCTION MANUAL MN7 series

Positive Displacement Flowmeters GM020 series instruction manual

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

macnaught flow measurement

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS

The experts in fluid technology

MODEL 200 MULTI-JET FLOW METER

High Turn Down Valve Model SF10000HTD Operations and Maintenance Manual. P.O. BOX 1728 Woodinville, WA USA FAX 425.

OM004, OM006 & OM008 Oval Gear Meter

Medium and high pressure pumps

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

Installation & Operation Manual

QUALITY INDUSTRIAL FLOWMETERS

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

HG 20F-012E-01 OIL CONTROL GUN

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

High Accuracy Mechanical Fuel meter FM-100

Purging Air From Divider Block Lubrication Systems

Valve Accessories NEW! Wanner Engineering Inc

LM-200 MECHANICAL LUBE METER Owner s Manual

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

QM Series Positive Displacement Fuel Meter

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

NECO Pumping Systems

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

macnaught flow measurement

TABLE OF CONTENTS GENERAL INFORMATION

MULTIPULSE SAP SUPER ACID PROOF POSITIVE DISPLACEMENT FLOWMETER

Lease Automatic Custody Transfer

POSITIVE DISPLACEMENT FLOWMETERS

Model 1100 Turbine Flow Meter

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

Installation Operation Maintenance ADDENDUM

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

Model DS1000/DT20 System

INSTALLATION AND OPERATION

APT14 Automatic Pump Trap Installation and Maintenance Instructions

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

FLOWMETER (SMALL CAPACITY) METER SIZE 80, 81

The experts in fluid handling

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1

Pulsation Dampeners NEW! Wanner Engineering Inc

MODEL 200 MULTI-JET FLOW METER

Transcription:

I N S T R U C T I O N M A N U A L Oval Gear Positive Displacement Mechanical Flowmeters Models: 3 (080), 3 (080E), 4 (100), 4 (100E) NSW TEL: (02) 9939 0711 FAX: (02) 9939 0411 QLD/PNG TEL: (07) 3204 9166 FAX: (07) 3204 1224 VIC/TAS TEL: (03) 8787 8288 FAX: (03) 8787 8266 WA TEL: (08) 9209 30665 FAX: (08) 9209 3933 SA/NT TEL: (08) 8241 7111 FAX: (08) 8241 7011 Visit our website at www.alemlube.com.au or www.alemlube.co.nz NZ TEL: (09) 447 1007 FAX: (09) 447 1008

2 Each meter has been calibrated on mineral oil and will contain a small amount of oil residue. The oil used is Castrol Diesel Calibration Fluid 4113 (product code 055830).

Index / contents 3 1.0 General Page 1.1 Overview 4 1.2 Operating principal 5 1.3 Specifications 6 2.0 Installation 2.1 Mechanical installation 7 2.1.1 Orientation 7 2.1.2 Flow conditioning & locations 8 3.0 Commissioning 9 4.0 Maintenance 9 5.0 Fault Finding 5.1 Fault finding 10 5.2 Trouble shooting 11

4 General 1.1 Overview The Oval Gear meter is a precise positive displacement flowmeter incorporating a pair of oval geared rotors, which is capable of measuring a broad range of clean liquids. Aluminium meters are suitable for fuels, fuel oils & lubricating liquids. This series of 3" (80mm) and 4" (100mm) flowmeters are available with the 4 digit mechanical registers, or with the optional V series 5 digit mechanical register. The V series register can also be used for mechanical batching applications when used in conjunction with the optional preset batcher and mechanically operated shut-off valve. These mechanical flowmeters can also be used in conjunction with an optional Air Eliminator Strainer (AES) which can be close coupled to the flowmeter.

Operating principal 5 1.2 Operating Principle The Oval gear are positive displacement flowmeters where the passage of liquid causes two oval geared rotors to rotate within a precision measuring chamber and with each rotation a fixed volume of liquid is displaced passing through the meter. The motion of the rotors is transmitted to the mechanical register totaliser via an interfacing reduction gear train & dynamic seal assembly. The benefits of this technology allow precise flow measurement and dispensing of most clean liquids irrespective of their conductivity, with other liquid characteristics having nil or minimal effect on meter performance. This metering technology does not require flow profile conditioning as required with alternative flow technologies making the installation relatively compact and low cost. OPERATION : Liquid travels around the crescent shaped chambers created by the rotational movement of the rotors liquid exits the measuring chamber flow liquid entering measuring chamber liquid in transit

6 Specifications 1.3 Specifications Model prefix : 080 080E 100 100E Nominal size ( inches ) 80mm ( 3" ) 80mm ( 3" ) 100mm ( 4" ) 100mm ( 4" ) * Flow range ( litres / min ) 35 ~ 750 50 ~ 1000 75 ~ 1500 150 ~ 2500 Accuracy @ 3cp ± 1% of reading with standard register & ± 0.5% of reading with V-series register Repeatability typically ± 0.03% Temperature range -20ºC ~ + 80ºC Maximum pressure (threaded meters) bar ( PSI ) Displays aluminium (AM-Series) 12 (175) 12 (175) 10 (145) 10 (145) Enviromental Protection Recommended filtering Preset batching option (VP, VZ) IP65 (V Series Registers = IP53/54) 350 micron ( 40 mesh ) minimum accumulative & resettable totals 1 & 2 stage mechanical batch control 4 digit reset mechanical totaliser 99999L 5 digit reset mechanical totaliser (V Series) 999999L Accumulative totaliser capacities 8 digit * Maximum flow on fuels may be increased by 10% for intermittent periods of refuelling. * Maximum flow is to be reduced as viscosity increases, max. pressure drop 100Kpa (15 psi)

2.0 Installation Installation 7 2.1 Mechanical Installation Prior to installing the meter check : # The fluid is compatible with the meter materials of construction using appropriate information such as fluid compatibility charts and site experience. # Application and process conditions are compatible with the meter specifications. Minimum and maximum flows are within the meter specified range including any in-situ cleaning processes. When metering viscous liquids the maximum allowable flow may need to be reduced to ensure the pressure drop across the meter does not exceed 100 kpa (1 Barg, 15 PSIG). # Process temperature and pressure does not exceed meter ratings. # The meter is not exposed to process temperatures and pressures that will cause the liquid medium to gasify (flash) within the meter. 2.1.1 Orientation The flowmeter MUST be mounted so that the rotor shafts are in a horizontal plane. This is achieved by mounting the meter so that the mechanical display is facing the user in a horizontal direction, it should never point towards the sky or towards the ground. If installed incorrectly the weight of the rotors will bear down on the lower end of the measuring chamber. C O R R E C T O R I E N T A T I O N Liquid can flow into the meter from either a horizontal or vertical direction. For vertical flow installations the most common orientation is for the liquid to rise through the meter (i.e. travel from bottom to top) to assist in air or entrained gas elimination. Be sure to observe flow direction (inlet & outlet markings). Each meter is supplied from the factory with the totaliser orientated to suit horizontal pipe runs, should the installation have a vertical pipe run the totaliser may be rotated 90º or 180º to change direction of flow direction, this is done by removing front & rear bezel screws, the counted wheel assembly can then be removed to access & remove the 4 housing screws then rotate the housing to the desired position, there will be a degree of resistance as you rotate the housing as it contains a large O-ring seal. Pay particular attention to the positioning of the following bevel, this must engage the drive bevel gear, when in position hold a screw driver blade against the reset knob seal as you rotate the reset knob to flair the seal into the counter bore position. Replace the register bezel and caps screws.

8 Installation 2.1.2 Flow Conditioning and Locations Strainer : It is recommended to INSTALL a 40mesh (350 micron) strainer immediately upstream of (prior to) the meter. Strainers are available from the factory. Flow conditioning : The flowmeter does not require any flow conditioning, therefore straight pipe runs before or after the meter are not required. If required, the pipe size about the meter can be altered to suit the installation. Locations : The flowmeter is preferred to be fitted upstream of any flow control and/or shut off valve, this prevents free discharge from the meter and minimizes the risk of drainage and air entrapment which can result in erroneous readings or damage the meter on start up. Process or safety critical meters should be installed in a by-pass section of pipe with isolation valves to enable the meter to be isolated and serviced as required. A by-pass installation also allows purging of the system during commissioning (see Commissioning).The meter must be appropriately rated and is typically located downstream (on the discharge side) of the pump. If mounted outdoors ensure a suitable watertight gland or plug is used to seal any open electrical entries. In humid environments take precautions to avoid condensation build up within the electrical and/or instrument enclosure. It is good wiring practice for conduits to be connected from the bottom of an entry port, in this way condensation will gravitate away from any terminal housing. Fluid state : Fluid entering the meter must remain a liquid state at all times so take necessary precautions to protect the meter by avoiding any factors that may result in solidification or gelling of the metered medium. If meters are to be trace heated or jacketed in any way the maximum temperature rating of the meter must not be exceeded. Size the meter to avoid gasification of volatiles (flashing) within the liquid due to the pressure drop experienced within the system or within the meter. Hydraulic shock : If pressure surges or hydraulic shock of any kind is possible, the system upstream of the meter must be fitted with a surge suppressor or pressure relief valve to protect the meter from damage. High frequency flow pulsations can damage the meter. Such pulsations can be caused by the injection profile in diesel engines. Most pulsations are removed with the installation of a suitable pulsation dampener.

Commissioning & Maintenance 9 3.0 Commissioning Once the meter has been mechanically installed the meter is ready for commissioning. The meter must NOT be run until the pipework is flushed of foreign matter, more often than not foreign matter is present after pipework fabrication or modification, weld slag, grinding dust, sealing tape & compound &/or surface rust are most common offenders. Flushing can be undertaken by utilizing a by-pass or removing the meter from the pipework. isolation valve flowmeter isolation valve strainer by-pass valve Open downstream valve last After flushing or following long periods of shutdown the meter must be purged of air/vapour. This can be achieved by allowing the liquid to flow through the meter at a slow rate until all air/vapour is displaced. Never run the meter above its maximum flow or exceed 100kpa (1 bar, 15psi) pressure drop across the meter. Now the meter is ready for its operation to be confirmed by ensuring correct indication or operation at the receiving instrument(s). Refer if necessary to fault finding section of this manual. 4.0 Maintenance Adhering to the installation instructions in this manual should ensure your meter provides the required operational performance. These are mechanical meters and a periodic inspection regime will maximize the operational availability of the meter. The frequency of inspection depends on the application factors including liquid lubricity and abrasiveness and operational factors such as flowrate and temperature. BEFORE removing meter for maintenance ensure the following : Associated alarm(s) or control output(s) are isolated so not to affect the process. Liquid supply to the meter is closed off. The meter is depressurized and liquid drained from the meter.

10 Fault Finding 5.1 Fault Finding Meters have two distinct sections: the mechanical wetted section housing the rotors and reduction gear assembly & the mechanical dry section from the register base (6) out. The aim of fault finding is to trace the source of the fault to one of these two sections. Wet section Dry section Below are basic fault finding steps. Also refer to Trouble Shooting Guide on following page. Step 1 - Check application, installation and set up. Refer to Mechanical Installation section for installation and application factors that may effect the meter operation including pulsation and air entrainment or incorrect meter selection including incorrect flow rate, temperature and pressure or materials compatibility. Step 2 - Check for blockages. The most common cause of fault/unsatisfactory meter operation, particularly for new or altered installations, is due to blockage within the system or meter caused by foreign particles such as weld slag, sealing tape or compound, rust, etc. Step 3 - Ensure flow is present. No flow or lower than normal minimum flow may be attributed to a blocked strainer, jammed or damaged rotors within the flowmeter, malfunctioning pump, closed valves or low liquid level in feeder tank. Step 4 - Ensure oval gears within meter are rotating. If the register is not totalizing first that the rotors are rotating by holding a screw driver blade to the meter body and pressing the handle hard against the ear lobe. If necessary test the meter with the flow turned off and turned on to familiarize yourself with the audible rotation signature. If the rotors are rotating then the problem will most probably be somewhere within the reduction gear assembly or totaliser assembly.

Trouble shooting 11 5.2 TROUBLE SHOOTING Symptom Meter readings are high Meter readings are low Register not Possible cause Solution 1. Entrained air or gas 1. Remov e source of air or gas entrapment 2. Install an upstream air eliminator 2. Pulsating flow 1. Increase back pressure on pump from reciprocating sty le pump 2. Install a fast response one w ay check v alv e 3. Install a surge arrestor betw een pump & meter 4. Re-calibrate meter in situ to compensate for pulsations 5. Change pump sty le to smooth deliv ery ty pe pump 1. Damaged or 1. Hav e meter inspected and repaired w orn rotors 2. Damaged or 1. Hav e meter inspected and repaired w orn measuring chamber 1. Rotors fouled 1. Check for obstruction due to foreign particles 2. Hav e meter inspected and repaired totalising 2. Gear train 1. Hav e meter inspected and repaired jammed

Each meter has been calibrated on mineral oil and will contain a small amount of oil residue. The oil used is Castrol Diesel Calibration Fluid 4113 (product code 055830). Alemlube 080~100E Mechanical Oct 2012 NSW TEL: (02) 9939 0711 FAX: (02) 9939 0411 QLD/PNG TEL: (07) 3204 9166 FAX: (07) 3204 1224 VIC/TAS TEL: (03) 8787 8288 FAX: (03) 8787 8266 WA TEL: (08) 9209 30665 FAX: (08) 9209 3933 Visit our website at www.alemlube.com.au or www.alemlube.co.nz SA/NT TEL: (08) 8241 7111 FAX: (08) 8241 7011 NZ TEL: (09) 447 1007 FAX: (09) 447 1008